Chile curtailment and equivalent storage: reproduce the published findings
==========================================================================

Acosta et al., Journal of Energy Storage 183 (2027), 125203, online October
2026. DOI: https://doi.org/10.1016/j.est.2026.125203.

**Business question:** How large is Chile's reported curtailment exposure, and
how does the paper's equivalent-storage indicator change with duration and
daytime-only scope? Published aggregates are reproduced offline, with rounding
audits. These are not a fresh CEN download or a feasible battery design.

The paper's 18.49% divides curtailment by reported generation. We also show the
potential-energy denominator. Hourly exports can be analyzed separately using
``python -m energy_analysis.chile_curtailment --hourly-config config.json``;
see ``docs/chile-curtailment-storage.md`` for the source contract and limitations.
"""

# %%
import matplotlib.pyplot as plt

from energy_analysis.chile_curtailment import reproduce_published_tables

results = reproduce_published_tables()
assert results["audit"]["matches_expected_agreement"].all(), "Unexpected published-table agreement"
annual = results["annual"]
scenarios = results["scenarios"].iloc[0]
print(annual.to_string(index=False))
print(f"Published comparisons within tolerance: {results['audit']['within_tolerance'].sum()}/35")
print("Source discrepancy: 2024 total computes to 19.0009%, versus 18.99% in Table 3.")
print(f"2025 effective 4h indicator: {scenarios['scenario_a_mw']:.1f} MW")
print(f"Uncovered indicator after 1714 MW installed BESS: {scenarios['uncovered_a_mw']:.1f} MW")
print(
    f"Block B only: {scenarios['scenario_b_mw']:.1f} MW; "
    f"reduction: {scenarios['reduction_relative_to_a_pct']:.2f}%"
)

# %%
# Annual source figures and the two denominators must be interpreted separately.
fig, axes = plt.subplots(2, 2, figsize=(12, 8), layout="constrained")
fig.suptitle("Chile: published curtailment and effective storage screening", fontsize=15)
years = annual["year"].astype(str)
axes[0, 0].bar(years, annual["pv_curtailment_gwh"], label="Solar PV", color="#e8a225")
axes[0, 0].bar(
    years,
    annual["wind_curtailment_gwh"],
    bottom=annual["pv_curtailment_gwh"],
    label="Wind",
    color="#357f9a",
)
axes[0, 0].set(title="Published curtailed energy (Tables 2-3)", ylabel="GWh/year")
axes[0, 0].legend()
axes[0, 1].plot(
    years, annual["curtailed_over_generated_pct"], "o-", label="Curtailed / generation (paper)"
)
axes[0, 1].plot(
    years,
    annual["curtailed_over_potential_pct"],
    "s--",
    label="Curtailed / (generation + curtailed)",
)
axes[0, 1].set(title="Two explicit denominator conventions", ylabel="Percent")
axes[0, 1].legend(fontsize=8)
for year, group in results["duration"].groupby("year"):
    axes[1, 0].plot(group["duration_hours"], group["eesc_mw"], "o-", label=str(year))
axes[1, 0].set(
    title="Equation 2, Table 7", xlabel="Discharge duration (hours)", ylabel="Effective EESC (MW)"
)
axes[1, 0].legend()
axes[1, 1].bar(
    ["All hours\nScenario A", "08:00-17:59\nScenario B"],
    [scenarios["scenario_a_mw"], scenarios["scenario_b_mw"]],
    color=["#357f9a", "#5eaf8b"],
)
axes[1, 1].axhline(1714, color="#b44b42", linestyle="--", label="Reported installed BESS: 1714 MW")
axes[1, 1].set(title="2025: change in included energy, 4h indicator", ylabel="Effective EESC (MW)")
axes[1, 1].legend(fontsize=8)
plt.show()

# %%
# The sensitivity retains the paper's multiplication by DoD and efficiency.
# Lower efficiency lowers this effective indicator, not required nameplate size.
matrix = (
    results["sensitivity"]
    .query("duration_hours == 4")
    .pivot(
        index="depth_of_discharge",
        columns="round_trip_efficiency",
        values="deviation_from_baseline_pct",
    )
)
fig, ax = plt.subplots(figsize=(7, 4), layout="constrained")
heat = ax.imshow(matrix.to_numpy(), cmap="RdBu", aspect="auto", vmin=-16, vmax=16)
ax.set(
    xticks=range(len(matrix.columns)),
    xticklabels=matrix.columns,
    yticks=range(len(matrix.index)),
    yticklabels=matrix.index,
    xlabel="Round-trip efficiency",
    ylabel="Depth of discharge",
    title="Effective EESC sensitivity: deviation from DoD 0.90 / efficiency 0.95",
)
for row in range(len(matrix.index)):
    for col in range(len(matrix.columns)):
        ax.text(
            col,
            row,
            f"{matrix.iloc[row, col]:+.1f}%",
            ha="center",
            va="center",
            fontsize=9,
            color="white" if abs(matrix.iloc[row, col]) > 10 else "black",
        )
fig.colorbar(heat, ax=ax, label="Deviation (%)")
plt.show()