NIST: import measured photovoltaic testbed exports
==================================================

The `NIST PV portal <https://pvdata.nist.gov/>`_ provides measured data from
ground-mounted, rooftop and canopy arrays in Gaithersburg, Maryland. This example
documents and executes the **native export import** workflow. Its default figure
is a field guide, with no invented or downloaded generation observations.

Download a one-minute CSV through the portal, then run::

    NIST_PV_CSV=/path/to/export.csv NIST_PV_ARRAY=ground \
      uv run python examples/connectors/plot_generation_nist.py

The connector accepts ordinary CSV and Campbell TOA5 headers, preserves original
columns and records the file's SHA-256. Portal accounts or transient download
tokens are not stored in the project. The script is included in the
:download:`generation example bundle <generation_examples.zip>`.
"""

# %%
# 1. Select the published AC power channel and time convention
# ------------------------------------------------------------
# The `NIST data paper <https://doi.org/10.6028/jres.122.040>`_ specifies Eastern
# **Standard** Time throughout the year, with no daylight-saving shift.
# ``InvPAC_kW_Avg`` is one-minute average inverter AC power in kW; the unsuffixed
# ``InvPAC_kW`` is a one-second instantaneous channel. Accumulated ``InvEtot_kWh``
# readings are a different physical quantity and are never treated as power.

import os
from pathlib import Path

import matplotlib.pyplot as plt

from energy_data_retrieval.sources.nist import NISTClient

export_path = os.environ.get("NIST_PV_CSV")
array = os.environ.get("NIST_PV_ARRAY", "ground")

# %%
# 2. Import real observations when a local provider export is supplied
# --------------------------------------------------------------------
# ``NAN`` readings remain missing. Negative/anomalous measurements remain as
# reported. The parser verifies kW and Avg metadata in TOA5 files and refuses
# conflicting duplicate timestamps. No interval-edge convention is invented.

if export_path:
    result = NISTClient().read_export(Path(export_path), array=array)
    frame = result.frame
    fig, ax = plt.subplots(figsize=(10, 4), layout="constrained")
    ax.plot(frame.timestamp, frame.value, color="#176e76", linewidth=0.9)
    ax.set(
        title=f"NIST {array}: imported measured one-minute AC power",
        ylabel="AC power [kW]",
        xlabel="UTC (source clock is fixed EST)",
    )
    print("Imported observations:", len(frame), "Input SHA-256:", frame.attrs["input_sha256"])
else:
    fig, ax = plt.subplots(figsize=(10, 4.5), layout="constrained")
    ax.axis("off")
    rows = [
        ["Download", "Choose Ground, Roof or Canopy in the NIST PV portal"],
        ["Power", "One-minute: InvPAC_kW_Avg [kW]"],
        ["Clock", "Fixed Eastern Standard Time = UTC-05:00"],
        ["Import", "NISTClient().read_export(path, array='ground')"],
        ["Provenance", "Original fields, input filename and SHA-256 retained"],
    ]
    table = ax.table(cellText=rows, colWidths=[0.18, 0.82], cellLoc="left", loc="center")
    table.auto_set_font_size(False)
    table.set_fontsize(10)
    table.scale(1, 2.1)
    ax.set_title("NIST PV: offline export guide — no measurements bundled", pad=20)
    print("Set NIST_PV_CSV to a real provider export to produce a measured power plot.")
plt.show()

# %%
# 3. Distinguish higher-frequency data and multiple channels
# ----------------------------------------------------------
# For one-second exports, explicitly select ``power_column='InvPAC_kW'`` and
# ``resolution='one-second'``. Meter power ``PwrMtrP_kW_Avg`` is also supported.
# A selected inverter/meter channel is not automatically the sum of every
# inverter in an array. Check the downloaded table and NIST instrument metadata.