OPS-SAT photodiodes: real signals and expert annotations
================================================================================

This example reads the original telemetry from the **OPSSAT-AD v2** release,
using the public ``orbitalpv`` API. It contains 303,493 measurements in 2,123
segments from nine channels: three magnetometers and six photodiodes.
The photodiode channels add measured illumination/attitude-related context to
OrbitalPV; they are not solar-panel electrical power measurements.

Source and interpretation
-------------------------

* Ruszczak et al. (2025), *The OPS-SAT benchmark for detecting anomalies in
  satellite telemetry*, https://doi.org/10.1038/s41597-025-05035-3.
* Original measurement CSV, version v2 (CC BY 4.0):
  https://doi.org/10.5281/zenodo.15108715.
* We use ``segments.csv``, not the separate derived-feature table
  ``dataset.csv``. No synthetic measurements are added.

The CSV supplies UTC timestamps and values but no engineering-unit field.
Values therefore stay in their published scale, labeled **source units**.
Photodiode channel names ending in ``THETA`` are preserved; we do not infer
irradiance, electrical current, power, or a calibrated angle unit from them.

The source is a curated selection of nominal and anomalous segments, not a
continuous mission log. We preserve its segment boundaries, missing periods,
and original training/test split. The expert labels describe this benchmark;
the example does not make a new anomaly diagnosis or estimate fleet failure
rates.
"""

from __future__ import annotations

from pathlib import Path
from tempfile import gettempdir

import matplotlib.pyplot as plt
import numpy as np

import orbitalpv as opv

# %% Step 1 — Retrieve and verify the original measurements
#
# The connector downloads the pinned 19 MB CSV once, checks its SHA-256 hash,
# and keeps a provenance sidecar. A subsequent run reuses the verified cache.
# It returns all published measurements; filtering can also be requested with
# ``channels=["CADC0892"]`` and ``split="test"``.

cache = Path(gettempdir()) / "orbitalpv-real-data"
with opv.OpsSatADConnector() as connector:
    telemetry = connector.download_frame(cache / "opssat_segments_v2.csv")

segments = telemetry.drop_duplicates("segment")
print(f"Measurements: {len(telemetry):,}")
print(f"Source segments: {len(segments):,}")
print(f"Channels: {telemetry['channel'].nunique()}")
print(f"UTC coverage: {telemetry['timestamp'].min()} to {telemetry['timestamp'].max()}")
print(f"Source: {telemetry.attrs['source_doi']} ({telemetry.attrs['license']})")
print(f"Complete-release checksum verified: {telemetry.attrs['matches_complete_release']}")

counts = telemetry.groupby(["channel", "sensor_type"], sort=True).size()
fig, ax = plt.subplots(figsize=(10, 4.5))
ax.bar(
    counts.index.get_level_values("channel"),
    counts.to_numpy(),
    color=["#167d8d" if kind == "photodiode" else "#7a8795" for _, kind in counts.index],
)
ax.set(
    title="Step 1 — Actual OPS-SAT measurement coverage",
    xlabel="Source channel",
    ylabel="Measurements",
)
ax.tick_params(axis="x", rotation=35)
ax.grid(axis="y", alpha=0.25)
fig.tight_layout()
plt.show()

# %% Step 2 — Inspect all six native photodiode signals
#
# These plots use every available photodiode measurement on its original UTC
# timestamp. Points leave unobserved periods blank; no line or interpolation
# bridges separate telemetry segments. Each channel retains its source value
# scale, so the y-axis is deliberately not labeled in watts or amperes.

photodiodes = telemetry[telemetry["sensor_type"].eq("photodiode")].copy()
print(f"Photodiode measurements: {len(photodiodes):,}")
fig, axes = plt.subplots(3, 2, figsize=(12, 9), sharex=True, sharey=True)
for ax, (channel, samples) in zip(
    axes.flat, photodiodes.groupby("channel", sort=True), strict=True
):
    ax.plot(samples["timestamp"], samples["value"], ".", markersize=1.5, alpha=0.5, color="#167d8d")
    ax.set_title(f"{channel} · {samples['channel_name'].iloc[0]}", fontsize=10)
    ax.set_ylabel("Source value [unit unspecified]")
    ax.grid(alpha=0.2)
for ax in axes[-1]:
    ax.set_xlabel("Source UTC time")
    ax.tick_params(axis="x", rotation=25)
fig.suptitle("Step 2 — All published photodiode samples; gaps remain visible")
fig.tight_layout()
plt.show()

# %% Step 3 — Compare provider-labeled segments within one channel
#
# We select the longest nominal and longest anomalous segment of CADC0892,
# making the choice reproducible. Each panel shows a separate segment against
# its actual elapsed seconds; a scatter plot keeps missing samples visible.
#
# Use the **numeric ``anomaly`` column** for the expert label. The source v2
# text column ``label`` says ``"anomaly"`` for nominal rows too. OrbitalPV
# preserves that field for provenance but does not use it for classification.

channel_samples = photodiodes[photodiodes["channel"].eq("CADC0892")]
sizes = channel_samples.groupby(["anomaly", "segment"]).size()
fig, axes = plt.subplots(1, 2, figsize=(12, 4.3), sharey=True)
for annotation, ax in enumerate(axes):
    segment_id = int(sizes.loc[annotation].idxmax())
    samples = channel_samples[channel_samples["segment"].eq(segment_id)].sort_values("timestamp")
    elapsed = (samples["timestamp"] - samples["timestamp"].iloc[0]).dt.total_seconds()
    color = "#ba4a40" if annotation else "#167d8d"
    label = "Anomalous" if annotation else "Nominal"
    ax.plot(elapsed, samples["value"], ".", markersize=3, color=color)
    ax.set(
        title=f"{label} source annotation · segment {segment_id}",
        xlabel="Elapsed seconds within this segment",
        ylabel="I_PD5_THETA [source unit unspecified]",
    )
    ax.grid(alpha=0.2)
    print(
        f"{label}: segment {segment_id}, {len(samples)} measurements, starts {samples['timestamp'].iloc[0]}"
    )
fig.suptitle("Step 3 — Published expert labels, not a new model diagnosis")
fig.tight_layout()
plt.show()

# %% Step 4 — Retain the benchmark labels and its fixed split
#
# Count **segments**, not individual samples, when summarizing the expert
# annotations. Segment lengths vary. The curated anomaly prevalence is not a
# mission-wide anomaly or failure rate. The original train/test assignment is
# kept intact and must not be confused with a chronological holdout.

photodiode_segments = photodiodes.drop_duplicates("segment")
by_channel = (
    photodiode_segments.groupby(["channel", "anomaly"])
    .size()
    .unstack(fill_value=0)
    .reindex(columns=[0, 1], fill_value=0)
)
by_split = (
    segments.assign(split=np.where(segments["train"].eq(1), "Training", "Test"))
    .groupby(["split", "anomaly"])
    .size()
    .unstack(fill_value=0)
    .reindex(index=["Training", "Test"], columns=[0, 1], fill_value=0)
)
fig, axes = plt.subplots(1, 2, figsize=(12, 4.5))
for ax, summary, title in zip(
    axes,
    [by_channel, by_split],
    ["Photodiode source segments", "All channels: published benchmark split"],
    strict=True,
):
    summary.rename(columns={0: "Nominal", 1: "Anomalous"}).plot.bar(
        ax=ax,
        stacked=True,
        color=["#167d8d", "#ba4a40"],
        rot=30,
    )
    ax.set(title=title, xlabel="", ylabel="Source segments")
    ax.grid(axis="y", alpha=0.25)
fig.suptitle("Step 4 — Curated labels and source split remain unchanged")
fig.tight_layout()
plt.show()

print("\nPublished segment split (numeric anomaly annotation):")
print(by_split.rename(columns={0: "nominal", 1: "anomalous"}).to_string())

# These measured signals can support studies of telemetry quality, sensor
# behavior, and illumination-related operating conditions. Calculating PV
# output would additionally require validated sensor calibration, geometry,
# panel electrical measurements, and a suitable PV model.