Laboratory BMP screening#
Screen laboratory biochemical methane potential on a VS-fed basis.
Unlike DigestionProcess, this interface does not require or infer VS destruction. The realization fraction is an explicit scale-up assumption, not a kinetic model.
- class x2power.methods.bmp.BMPProcess(volatile_solids_fraction_dry, methane_potential_nm3_per_kg_vs_fed, realization_fraction, methane_fraction=0.6, capture_fraction=0.98, methane_lhv_kwh_per_nm3=9.94)[source]#
Dry normal methane potential per kg VS FED, before collection losses.
Potential is a laboratory value at 0 C and 101325 Pa. Realization scales the potential before methane capture and CHP availability are applied separately. No transient digestion, nutrient adequacy or mono-digestion stability is solved.
- Parameters:
volatile_solids_fraction_dry (float)
methane_potential_nm3_per_kg_vs_fed (float)
realization_fraction (float)
methane_fraction (float)
capture_fraction (float)
methane_lhv_kwh_per_nm3 (float)
- volatile_solids_fraction_dry: float#
- methane_potential_nm3_per_kg_vs_fed: float#
- realization_fraction: float#
- methane_fraction: float = 0.6#
- capture_fraction: float = 0.98#
- methane_lhv_kwh_per_nm3: float = 9.94#
- x2power.methods.bmp.simulate_bmp_digestion(feedstock, process, generator, *, duration_h=1.0, availability=1.0, process_heat_kwh=0.0, auxiliaries=None)[source]#
Map feed and realized BMP to electricity; feed is an interval total.
Digestion is represented as an established steady process without inventories. The upstream methane supply is uniform even during a CHP outage. Unused fuel is reported, with no implicit storage, flaring or emissions treatment.
- Parameters:
feedstock (SolidFeedstock)
process (BMPProcess)
generator (Generator)
duration_h (float)
availability (float)
process_heat_kwh (float)
auxiliaries (AuxiliaryLoads | None)
- Return type: