"""Screen solar-powered orbital compute against power, heat and launch limits.

This composes OrbitalPV's circular-shadow, periodic-load and battery-dispatch
models. Inputs are design assumptions, not a flight-qualified spacecraft model.
The radiator has a prescribed temperature and total emitting area, not a CAD
footprint. A fixed heat allowance reserves capacity for EPS/storage losses.
"""

from __future__ import annotations

from dataclasses import dataclass, replace
from math import ceil, floor

import numpy as np
import pandas as pd

from .orbit import circular_eclipse_duration_s, circular_orbit_period_s
from .physics import BatterySpec, dispatch_power, periodic_load_limit, radiator_feasibility


def _positive(name: str, value: float, *, zero: bool = False) -> None:
    if not np.isfinite(value) or (value < 0 if zero else value <= 0):
        raise ValueError(f"{name} must be finite and {'nonnegative' if zero else 'positive'}")


[docs] @dataclass(frozen=True) class OrbitalComputeSpec: """Explicit SI inputs; AM0 efficiency must be independently characterized. ``pv_area_m2`` is the deployed array footprint. Packing excludes inactive area; derate covers mismatch/wiring, and EPS efficiency is separate. Retention is an imposed sensitivity, not a prediction of radiation damage. ``thermal_allowance_w`` must cover converter/storage heat on this radiator; PV blanket absorption is assumed to radiate through its separate surface. """ altitude_m: float beta_angle_deg: float pv_area_m2: float efficiency_am0: float packing_fraction: float pv_temperature_c: float temperature_coefficient_per_k: float array_derate: float eps_efficiency: float retained_power_fraction: float irradiance_w_m2: float platform_load_w: float average_compute_w: float peak_compute_w: float radiator_emitting_area_m2: float radiator_temperature_k: float radiator_emissivity: float absorbed_environment_w_m2: float thermal_allowance_w: float battery: BatterySpec def __post_init__(self) -> None: for name in ( "altitude_m", "pv_area_m2", "irradiance_w_m2", "average_compute_w", "peak_compute_w", "radiator_emitting_area_m2", "radiator_temperature_k", ): _positive(name, getattr(self, name)) for name in ("platform_load_w", "absorbed_environment_w_m2", "thermal_allowance_w"): _positive(name, getattr(self, name), zero=True) for name in ( "efficiency_am0", "packing_fraction", "array_derate", "eps_efficiency", "retained_power_fraction", "radiator_emissivity", ): value = getattr(self, name) if not np.isfinite(value) or not 0 < value <= 1: raise ValueError(f"{name} must lie in (0, 1]") if not np.isfinite(self.beta_angle_deg) or abs(self.beta_angle_deg) > 90: raise ValueError("beta_angle_deg must lie in [-90, 90]") if not np.isfinite(self.pv_temperature_c) or self.pv_temperature_c <= -273.15: raise ValueError("pv_temperature_c must be finite and above absolute zero") if not np.isfinite(self.temperature_coefficient_per_k): raise ValueError("temperature_coefficient_per_k must be finite") factor = 1 + self.temperature_coefficient_per_k * (self.pv_temperature_c - 25) if factor <= 0 or self.efficiency_am0 * factor > 1: raise ValueError("temperature correction gives a nonphysical PV efficiency") if self.peak_compute_w < self.average_compute_w: raise ValueError("peak_compute_w must be at least average_compute_w")
[docs] def screen_orbital_compute(spec: OrbitalComputeSpec) -> dict[str, float | bool]: """Calculate repeatable continuous compute and necessary sizing conditions. The electrical bound includes orbit energy, SOC window and battery power limits. Heat rejection assumes all served electrical load becomes heat. Neither a nameplate compute rating nor an initially full battery creates sustainable energy. Area/storage requirements alone are not sufficient: charge/discharge ratings and thermal capacity must also pass. """ period_h = circular_orbit_period_s(spec.altitude_m) / 3600 eclipse_h = float(circular_eclipse_duration_s(spec.altitude_m, spec.beta_angle_deg)) / 3600 sunlight_h = period_h - eclipse_h temperature_factor = 1 + spec.temperature_coefficient_per_k * (spec.pv_temperature_c - 25) bus_density = ( spec.irradiance_w_m2 * spec.efficiency_am0 * spec.packing_fraction * temperature_factor * spec.array_derate * spec.eps_efficiency * spec.retained_power_fraction ) sunlit_power = bus_density * spec.pv_area_m2 # Conservative bound: EPS loss plus the larger battery conversion loss. # Charge/discharge do not occur simultaneously. Counting EPS loss during # discharge as well is conservative; curtailed generation is included. loss_bound = sunlit_power * (1 / spec.eps_efficiency - 1) + max( min(sunlit_power, spec.battery.max_charge_w) * (1 - spec.battery.charge_efficiency), min(spec.peak_compute_w + spec.platform_load_w, spec.battery.max_discharge_w) * (1 / spec.battery.discharge_efficiency - 1), ) if spec.thermal_allowance_w + 1e-8 < loss_bound: raise ValueError("thermal_allowance_w must cover the conservative EPS/battery loss bound") limits = periodic_load_limit(sunlit_power, sunlight_h, eclipse_h, battery=spec.battery) target = spec.platform_load_w + spec.average_compute_w radiator = radiator_feasibility( target + spec.thermal_allowance_w, area_m2=spec.radiator_emitting_area_m2, radiator_temperature_k=spec.radiator_temperature_k, emissivity=spec.radiator_emissivity, absorbed_environment_w_m2=spec.absorbed_environment_w_m2, ) thermal_bus_limit = max( float(radiator["available_heat_rejection_w"]) - spec.thermal_allowance_w, 0 ) total_limit = min(limits["sustainable_load_w"], thermal_bus_limit) compute_limit = min(spec.peak_compute_w, max(total_limit - spec.platform_load_w, 0)) battery = spec.battery roundtrip = battery.charge_efficiency * battery.discharge_efficiency required_sunlit = target * (1 + eclipse_h / (sunlight_h * roundtrip)) soc_window = battery.maximum_soc - battery.minimum_soc required_battery = ( target * eclipse_h / (soc_window * battery.discharge_efficiency) if eclipse_h > 0 and soc_window > 0 else (float("inf") if eclipse_h > 0 else 0.0) ) required_charge = target * eclipse_h / (sunlight_h * roundtrip) return { "orbit_period_min": period_h * 60, "eclipse_min": eclipse_h * 60, "sunlight_fraction": sunlight_h / period_h, "sunlit_bus_power_kw": sunlit_power / 1000, "eps_battery_heat_bound_kw": loss_bound / 1000, "electrical_bus_limit_kw": limits["sustainable_load_w"] / 1000, "thermal_bus_limit_kw": thermal_bus_limit / 1000, "sustainable_compute_kw": compute_limit / 1000, "average_target_feasible": bool(compute_limit >= spec.average_compute_w - 1e-8), "platform_continuous_feasible": bool(total_limit >= spec.platform_load_w), "required_pv_area_m2": required_sunlit / bus_density, "required_nominal_battery_kwh": required_battery / 1000, "required_charge_kw": required_charge / 1000, "required_discharge_kw": target / 1000 if eclipse_h > 0 else 0.0, "required_radiator_emitting_area_m2": float(radiator["required_area_m2"]), }
[docs] def simulate_orbital_compute( spec: OrbitalComputeSpec, *, cycles: int = 40, intervals_per_orbit: int = 120, peak_fraction: float = 0.2, dispatch_policy: str = "greedy", ) -> pd.DataFrame: """Dispatch orbit-repeating bursts with exactly the requested mean load. Each cycle starts in sunlight, followed by eclipse. The peak occupies the last ``peak_fraction`` of each orbit (a deliberately adverse alignment). Boundaries include shadow entry and burst start exactly, avoiding timestep aliasing. Platform demand has priority within each interval, with no lookahead reserve for future platform demand; overload can cause outages. A fixed radiator cap excludes thermal inertia, and the full trace reports SOC drift and unserved energy. Initial SOC is set to the reserve floor to avoid gifting stored energy. ``continuous_cap`` admits at most the repeatable continuous compute bound at every interval. This conservative admission policy protects platform demand under this fixed repeating geometry, provided the platform alone is feasible. It can reject useful sunlit bursts; it is not an optimal scheduler or protection against uncertain generation. ``greedy`` preserves the original unconstrained demand. Requested, admitted and rejected compute are reported separately; rejected work is not automatically rescheduled. Dispatch conservation columns refer to admitted electrical demand. """ if isinstance(cycles, bool) or not isinstance(cycles, int) or cycles < 1: raise ValueError("cycles must be a positive integer") if ( isinstance(intervals_per_orbit, bool) or not isinstance(intervals_per_orbit, int) or intervals_per_orbit < 2 ): raise ValueError("intervals_per_orbit must be an integer >= 2") if not np.isfinite(peak_fraction) or not 0 <= peak_fraction < 1: raise ValueError("peak_fraction must lie in [0, 1)") low_compute = (spec.average_compute_w - peak_fraction * spec.peak_compute_w) / ( 1 - peak_fraction ) if low_compute < 0: raise ValueError("peak_fraction makes the off-peak compute load negative") if dispatch_policy not in ("greedy", "continuous_cap"): raise ValueError("dispatch_policy must be greedy or continuous_cap") screen = screen_orbital_compute(spec) if dispatch_policy == "continuous_cap" and not screen["platform_continuous_feasible"]: raise ValueError("continuous_cap requires a continuously feasible platform") period = float(screen["orbit_period_min"]) * 60 eclipse = float(screen["eclipse_min"]) * 60 sun_end = period - eclipse peak_start = period * (1 - peak_fraction) one_cycle = np.unique( np.r_[np.linspace(0, period, intervals_per_orbit + 1), sun_end, peak_start] ) # Merge a transition that coincides with a regular edge to floating-point # precision before shifting many cycles (otherwise tiny gaps can collapse). one_cycle = one_cycle[np.r_[True, np.diff(one_cycle) > period * 1e-12]] edges = np.r_[ np.concatenate([one_cycle[:-1] + i * period for i in range(cycles)]), cycles * period ] phase = ((edges[:-1] + edges[1:]) / 2) % period generation = np.where(phase < sun_end, float(screen["sunlit_bus_power_kw"]) * 1000, 0) compute = np.where(phase >= peak_start, spec.peak_compute_w, low_compute) admitted = ( np.minimum(compute, float(screen["sustainable_compute_kw"]) * 1000) if dispatch_policy == "continuous_cap" else compute ) trace = dispatch_power( edges, generation, admitted + spec.platform_load_w, battery=replace(spec.battery, initial_soc=spec.battery.minimum_soc), maximum_served_power_w=float(screen["thermal_bus_limit_kw"]) * 1000, ) trace["cycle"] = np.floor(((edges[:-1] + edges[1:]) / 2) / period).astype(int) trace["requested_compute_w"] = compute trace["admitted_compute_w"] = admitted trace["rejected_compute_wh"] = (compute - admitted) * trace.duration_h trace["dispatch_policy"] = dispatch_policy trace["served_platform_w"] = np.minimum(trace.served_load_w, spec.platform_load_w) trace["served_compute_w"] = trace.served_load_w - trace.served_platform_w trace["unserved_compute_wh"] = (compute - trace.served_compute_w) * trace.duration_h # Conservative check: even curtailed array output is charged to EPS losses. trace["modeled_eps_battery_heat_w"] = ( generation * (1 / spec.eps_efficiency - 1) + trace.battery_loss_wh / trace.duration_h ) trace["thermal_allowance_exceeded"] = ( trace.modeled_eps_battery_heat_w > spec.thermal_allowance_w + 1e-8 ) return trace
[docs] def deployment_screen( *, manufacturing_gw_per_year: float, factory_utilization: float, manufacturing_yield: float, space_allocation_fraction: float, array_area_m2: float, packing_fraction: float, efficiency_stc: float, satellite_mass_kg: float, payload_to_target_orbit_kg: float, launches_per_year: int, continuous_compute_kw: float, compute_utilization: float = 1.0, ) -> dict[str, float | int | None]: """Annual deployment ceiling on an explicitly assumed STC factory basis. Annual GW nameplate production is NOT delivered orbital GW or compute GW. Array watts here use 1000 W/m² STC and a separately supplied efficiency. Full spacecraft mass includes PV, radiator, storage and structure. Launch throughput is mass-only: fairing volume, deployment reliability, networking, approvals, satellite factory throughput and replacements are excluded. """ for name, value in ( ("manufacturing_gw_per_year", manufacturing_gw_per_year), ("continuous_compute_kw", continuous_compute_kw), ): _positive(name, value, zero=True) for name, value in ( ("array_area_m2", array_area_m2), ("satellite_mass_kg", satellite_mass_kg), ("payload_to_target_orbit_kg", payload_to_target_orbit_kg), ): _positive(name, value) for name, value in ( ("factory_utilization", factory_utilization), ("manufacturing_yield", manufacturing_yield), ("space_allocation_fraction", space_allocation_fraction), ("compute_utilization", compute_utilization), ): if not np.isfinite(value) or not 0 <= value <= 1: raise ValueError(f"{name} must lie in [0, 1]") for name, value in (("packing_fraction", packing_fraction), ("efficiency_stc", efficiency_stc)): if not np.isfinite(value) or not 0 < value <= 1: raise ValueError(f"{name} must lie in (0, 1]") if ( isinstance(launches_per_year, bool) or not isinstance(launches_per_year, int) or launches_per_year < 0 ): raise ValueError("launches_per_year must be a nonnegative integer") array_stc_kw = array_area_m2 * packing_fraction * efficiency_stc usable_gw = ( manufacturing_gw_per_year * factory_utilization * manufacturing_yield * space_allocation_fraction ) arrays = floor(usable_gw * 1e6 / array_stc_kw) per_launch = floor(payload_to_target_orbit_kg / satellite_mass_kg) launched = min(arrays, per_launch * launches_per_year) return { "array_stc_kw": array_stc_kw, "usable_factory_gw_per_year": usable_gw, "arrays_per_year": arrays, "satellites_per_launch": per_launch, "launch_limited_satellites_per_year": per_launch * launches_per_year, "deployed_satellites_per_year": launched, "launches_to_deploy_factory_output": ceil(arrays / per_launch) if per_launch else (0 if arrays == 0 else None), "launch_payload_can_fit_one_satellite": int(per_launch > 0), "deployed_array_stc_gw_per_year": launched * array_stc_kw / 1e6, "added_continuous_compute_gw": launched * continuous_compute_kw / 1e6, "added_utilized_compute_gw": launched * continuous_compute_kw * compute_utilization / 1e6, }