Continuous biogas plant: feed, storage and electricity#

Follow a synthetic 1 MW CHP plant from three organic feedstocks to grid export. The model carries volatile-solids and gas inventories between hourly intervals. The inputs are illustrative, not measurements or a reconstruction of a real plant.

from dataclasses import replace

from x2power import Generator
from x2power.methods.biogas_plant import (
    BiogasPlant,
    ContinuousDigester,
    DigesterFeedstock,
    PlantInterval,
    initial_plant_state,
    simulate_biogas_plant,
)
from x2power.utilities.biogas_plant import summarize_plant
from x2power.utilities.plant_plotting import plot_biogas_plant

1. Define a mixed feed of 100 tonnes per day. TS is per wet mass, VS is per TS, and methane yield is per VS destroyed. Each substrate has its own decay constant and degradable fraction; these require laboratory/operating calibration.

feedstocks = (
    DigesterFeedstock(
        "food_processing_residues", 45000, 0.22, 0.9, 0.85, 0.55, 0.12, dry_lhv_mj_per_kg=20
    ),
    DigesterFeedstock("livestock_slurry", 35000, 0.08, 0.8, 0.65, 0.45, 0.06, dry_lhv_mj_per_kg=20),
    DigesterFeedstock("organic_sludge", 20000, 0.06, 0.75, 0.65, 0.48, 0.08, dry_lhv_mj_per_kg=20),
)
plant = BiogasPlant(
    feedstocks,
    ContinuousDigester(
        3500, heat_loss_kw_per_k=0.55, minimum_hrt_days=15, maximum_olr_kg_vs_m3_day=5
    ),
    Generator(0.38, 0.45, rated_power_kw=1000),
    gas_storage_capacity_nm3=2500,
    fixed_auxiliary_power_kw=20,
    mixing_power_w_per_m3=3,
    feed_preparation_kwh_per_tonne=2,
    gas_treatment_kwh_per_nm3=0.02,
    electric_heater_efficiency=0.98,
)

2. Begin with steady-feed substrate inventories and an empty gas holder. Resolve a 12-hour CHP outage on day 6 explicitly, then stop feeds during days 11 and 12. The digesters stay warm: unmet digester heat uses an electric backup heater.

schedule = [
    PlantInterval(
        feed_multipliers=(0.0 if 240 <= hour < 288 else 1.0,) * 3,
        generator_availability=0.0 if 120 <= hour < 132 else 1.0,
        feed_temperature_c=12,
        ambient_temperature_c=10,
        site_electricity_demand_kw=150,
        site_heat_demand_kw=300,
    )
    for hour in range(30 * 24)
]
initial = initial_plant_state(plant, interval=schedule[0])
results = simulate_biogas_plant(plant, schedule, initial_state=initial)
first = results[0]
print(f"Initial HRT: {first.metrics['hydraulic_retention_days']:.1f} days")
print(f"Initial OLR: {first.metrics['organic_loading_kg_vs_m3_day']:.2f} kg VS/m³/day")
Initial HRT: 35.0 days
Initial OLR: 3.44 kg VS/m³/day

3. Read the four ledgers: captured gas/CHP/flare, electrical output, gas-holder inventory and heat. Gas keeps forming during the outage and feed interruption. A full holder sends excess gas to an ideal flare. During outages, plant net electricity is negative because auxiliary loads and backup heating continue.

figure = plot_biogas_plant(results, title="Synthetic 1 MW biogas CHP: 30-day operating profile")
X2Power simulation result

4. Compare the same feed, initial gas and schedule without a holder. Initial VS inventories stay identical. Include final gas inventory in the comparison: gas left in the holder has not yet generated electricity.

without_storage = simulate_biogas_plant(
    replace(plant, gas_storage_capacity_nm3=0), schedule, initial_state=initial
)
for label, outcome in (("2500 Nm³ holder", results), ("No holder", without_storage)):
    summary = summarize_plant(outcome)
    print(
        f"{label}: net {summary['net_electricity_kwh'] / 1000:.2f} MWh; "
        f"export {summary['grid_export_kwh'] / 1000:.2f} MWh; "
        f"flare {summary['biogas_flared_nm3']:.0f} Nm³; "
        f"final stored {summary['final_stored_biogas_nm3']:.0f} Nm³"
    )
2500 Nm³ holder: net 388.86 MWh; export 284.86 MWh; flare 779 Nm³; final stored 0 Nm³
No holder: net 383.20 MWh; export 279.19 MWh; flare 3279 Nm³; final stored 0 Nm³

5. Check the conservation residuals, then retain independent plant observations for calibration/validation. Conservation alone does not establish accuracy.

summary = summarize_plant(results)
print(f"Maximum VS residual: {summary['maximum_absolute_vs_balance_residual_kg']:.3e} kg")
print(f"Maximum gas residual: {summary['maximum_absolute_gas_balance_residual_nm3']:.3e} Nm³")
Maximum VS residual: 5.821e-11 kg
Maximum gas residual: 0.000e+00 Nm³

Total running time of the script: (0 minutes 0.381 seconds)