energy_analysis.pv_device_reliability#
PV-specific reliability evidence and reproducible, explicitly scoped cases.
- energy_analysis.pv_device_reliability.published_rate_scenarios()[source]#
Recalculate constant-rate scenarios, excluding internally conflicting rows.
Each row is a separate benchmark; alternative sources are never pooled. Per-year values use the source’s 4015 operating hours. Probabilities are model-derived, not observed annual failure fractions or warranty estimates.
- Return type:
DataFrame
- energy_analysis.pv_device_reliability.combiner_box_case(*, boxes=500)[source]#
Illustrative CBX bill of materials using disjoint, attributed part rates.
Twenty-four string fuses, 48 lugs, one SMU and one DC switch per box. Not a reproduction of a particular OEM design, nor whole-box outage risk. No tracker/WST proxy rates or assumed repair costs are inserted.
- Parameters:
boxes (int)
- Return type:
tuple[DataFrame, dict[str, float]]
- energy_analysis.pv_device_reliability.repair_time_sensitivity()[source]#
Synthetic 10 MW fleet: restoration sensitivity, not a site forecast.
Assumed constant calendar-up-time failure rate 0.04 per unit-year, with exponential restoration. Counterfactual fleet output follows an artificial 12-hour sinusoidal day, repeated for 365 days. Identical unit availability multiplies total fleet output in expectation; no shared crews/common cause. Neither the rate, repair durations nor production profile is field evidence.
- Return type:
DataFrame
- energy_analysis.pv_device_reliability.plot_pv_reliability_evidence()[source]#
Four panels with source-specific units; no universal device ranking.
- Return type:
Figure