energy_methods.pv_news_claims#

Audit aggregate PV news claims against explicit physical and accounting baselines.

News release claims are inputs, not observed generation or verified emissions.

class energy_methods.pv_news_claims.PVClaimAudit(equivalent_generation_mwh, dc_equivalent_full_load_hours, dc_equivalent_capacity_factor, co2_floor_kg_per_kwh, grid_average_tonnes_co2e)[source]#

Bases: object

Derived energy and carbon quantities, with the distinct boundaries retained.

co2_floor_kg_per_kwh is a lower bound on the CO2 displacement factor implied by the release’s avoided-CO2 claim, not a grid observation. grid_average_tonnes_co2e is an illustrative location-average accounting benchmark and is NOT a statement of avoided emissions or consequential impact.

Parameters:
  • equivalent_generation_mwh (float)

  • dc_equivalent_full_load_hours (float)

  • dc_equivalent_capacity_factor (float)

  • co2_floor_kg_per_kwh (float)

  • grid_average_tonnes_co2e (float)

equivalent_generation_mwh: float#
dc_equivalent_full_load_hours: float#
dc_equivalent_capacity_factor: float#
co2_floor_kg_per_kwh: float#
grid_average_tonnes_co2e: float#
energy_methods.pv_news_claims.audit_pv_news_claims(*, capacity_mwp, homes_equivalent, annual_household_kwh, avoided_co2_floor_tonnes, grid_average_kgco2e_per_kwh, hours_per_year=8760.0)[source]#

Infer energy-equivalence and emissions-intensity bounds from a PV news release.

Parameters:
  • capacity_mwp (float) – Published DC peak capacity in MWp; not an AC export rating.

  • homes_equivalent (float) – Published approximate annual number of households supplied (not metered).

  • annual_household_kwh (float) – Explicit household electricity-consumption benchmark (kWh/home/year).

  • avoided_co2_floor_tonnes (float) – Lower bound for developer’s claimed annual avoided tonnes of CO2.

  • grid_average_kgco2e_per_kwh (float) – Independent average grid emission-factor reference (kg CO2e/kWh).

  • hours_per_year (float) – Calendar hours in the reference year; default is a non-leap 365-day year.

Return type:

PVClaimAudit

Notes

This is an algebraic screening tool, not a PV yield, marginal-emissions, additionality or lifecycle-assessment model. Numerical results are conditional on the representative household demand assumed by the caller. The distinct CO2 and CO2e boundaries must NOT be silently compared as equivalent.