energy_methods.pv_news_claims#
Audit aggregate PV news claims against explicit physical and accounting baselines.
News release claims are inputs, not observed generation or verified emissions.
- class energy_methods.pv_news_claims.PVClaimAudit(equivalent_generation_mwh, dc_equivalent_full_load_hours, dc_equivalent_capacity_factor, co2_floor_kg_per_kwh, grid_average_tonnes_co2e)[source]#
Bases:
objectDerived energy and carbon quantities, with the distinct boundaries retained.
co2_floor_kg_per_kwhis a lower bound on the CO2 displacement factor implied by the release’s avoided-CO2 claim, not a grid observation.grid_average_tonnes_co2eis an illustrative location-average accounting benchmark and is NOT a statement of avoided emissions or consequential impact.- Parameters:
equivalent_generation_mwh (float)
dc_equivalent_full_load_hours (float)
dc_equivalent_capacity_factor (float)
co2_floor_kg_per_kwh (float)
grid_average_tonnes_co2e (float)
- equivalent_generation_mwh: float#
- dc_equivalent_full_load_hours: float#
- dc_equivalent_capacity_factor: float#
- co2_floor_kg_per_kwh: float#
- grid_average_tonnes_co2e: float#
- energy_methods.pv_news_claims.audit_pv_news_claims(*, capacity_mwp, homes_equivalent, annual_household_kwh, avoided_co2_floor_tonnes, grid_average_kgco2e_per_kwh, hours_per_year=8760.0)[source]#
Infer energy-equivalence and emissions-intensity bounds from a PV news release.
- Parameters:
capacity_mwp (float) – Published DC peak capacity in MWp; not an AC export rating.
homes_equivalent (float) – Published approximate annual number of households supplied (not metered).
annual_household_kwh (float) – Explicit household electricity-consumption benchmark (kWh/home/year).
avoided_co2_floor_tonnes (float) – Lower bound for developer’s claimed annual avoided tonnes of CO2.
grid_average_kgco2e_per_kwh (float) – Independent average grid emission-factor reference (kg CO2e/kWh).
hours_per_year (float) – Calendar hours in the reference year; default is a non-leap 365-day year.
- Return type:
Notes
This is an algebraic screening tool, not a PV yield, marginal-emissions, additionality or lifecycle-assessment model. Numerical results are conditional on the representative household demand assumed by the caller. The distinct CO2 and CO2e boundaries must NOT be silently compared as equivalent.