energy_methods.pvcz#
Karin, Jones and Jain (2019) PVCZ thresholds and Arrhenius stress.
Table I: ten temperature zones by five specific-humidity zones. This is a stressor classification, not a predicted degradation rate or lifetime.
- energy_methods.pvcz.equivalent_temperature(temperature_c, *, activation_energy_ev=1.1, duration_hours=1.0)[source]#
Arrhenius-equivalent °C over the last axis, weighted by interval duration.
Supply module temperatures including nights. Any missing interval makes its result missing; there is no gap filling. A time series with explicit missing rows is required to represent gaps. Duration cannot reveal omitted rows.
- Parameters:
temperature_c (Buffer | _SupportsArray[dtype[Any]] | _NestedSequence[_SupportsArray[dtype[Any]]] | complex | bytes | str | _NestedSequence[complex | bytes | str])
activation_energy_ev (float)
duration_hours (Buffer | _SupportsArray[dtype[Any]] | _NestedSequence[_SupportsArray[dtype[Any]]] | complex | bytes | str | _NestedSequence[complex | bytes | str])
- Return type:
ndarray[tuple[Any, …], dtype[float64]]
- energy_methods.pvcz.classify_pvcz(equivalent_temperature_c, specific_humidity_g_kg, *, provenance)[source]#
Apply fixed published boundaries; equality enters the warmer/wetter class.
Humidity is specific humidity (g/kg), never relative humidity (%). Positive IDs are the upstream zero-based PVCZ ID + 1, leaving zero for missing inputs. Use the reference 1.1 eV equivalent temperature for the published scheme.
- Parameters:
equivalent_temperature_c (Buffer | _SupportsArray[dtype[Any]] | _NestedSequence[_SupportsArray[dtype[Any]]] | complex | bytes | str | _NestedSequence[complex | bytes | str])
specific_humidity_g_kg (Buffer | _SupportsArray[dtype[Any]] | _NestedSequence[_SupportsArray[dtype[Any]]] | complex | bytes | str | _NestedSequence[complex | bytes | str])
provenance (ClimateProvenance)
- Return type: