energy_methods.wind_shared_outage#

Finite-fleet wind outage exposure with independent and shared-event scenarios.

This is a transparent, single-period probability mixture, NOT an inferred blade failure rate, a causal diagnosis, or a field-calibrated availability prediction.

Background: Mosleh et al. (1998), NUREG/CR-5485, guidelines for evaluating common-cause failures in probabilistic risk assessment. This illustrative mixture is NOT an implementation of a calibrated NRC alpha/beta-factor model.

class energy_methods.wind_shared_outage.WindOutageExposure(turbine_count, rated_power_mw, capacity_factor, window_hours, probability_by_unavailable)[source]#

Bases: object

Scenario distribution for unavailable turbines in ONE assessment period.

Probabilities, p95/p99, and energy are conditional on stated hypothetical inputs. The MWh values assume each unavailable turbine misses the whole stated window at one constant counterfactual capacity factor.

Parameters:
  • turbine_count (int)

  • rated_power_mw (float)

  • capacity_factor (float)

  • window_hours (float)

  • probability_by_unavailable (tuple[float, ...])

turbine_count: int#
rated_power_mw: float#
capacity_factor: float#
window_hours: float#
probability_by_unavailable: tuple[float, ...]#
at_least(unavailable_turbines)[source]#

P(K >= threshold), including the threshold (K=unavailable units).

Parameters:

unavailable_turbines (int)

Return type:

float

unavailable_quantile(quantile)[source]#

Left-continuous discrete quantile of turbine unavailability.

Parameters:

quantile (float)

Return type:

int

property expected_unavailable: float#

Mean number of simultaneously unavailable turbines.

property per_turbine_exposure_mwh: float#

Synthetic full-window energy exposure if one turbine is unavailable.

property expected_exposure_mwh: float#

Illustrative expected MWh at risk, NOT observed curtailed generation.

exposure_quantile_mwh(quantile)[source]#

Illustrative MWh-at-risk quantile under full-window unavailability.

Parameters:

quantile (float)

Return type:

float

energy_methods.wind_shared_outage.screen_wind_shared_outage(*, turbine_count, rated_power_mw, independent_probability, shared_event_probability=0.0, shared_affected_turbines=0, capacity_factor=0.45, window_hours=24.0)[source]#

Mixture of independent turbine unavailability and a shared outage.

Model: with probability q a shared event removes exactly m distinct units; each of the remaining n-m units independently fails with probability p. Without a shared event all n units independently fail with probability p. Thus P(K=k)=(1-q)Bin(n,p)[k] + q Bin(n-m,p)[k-m].

p and q are assessment-window scenario probabilities, not event rates, not estimated from the He Dreiht blade incident. All units are identical; failures and shutdowns last the full assumed window. This is not a turbine structural-integrity model, a reliability certification, or a safety plan.

Parameters:
  • turbine_count (int)

  • rated_power_mw (float)

  • independent_probability (float)

  • shared_event_probability (float)

  • shared_affected_turbines (int)

  • capacity_factor (float)

  • window_hours (float)

Return type:

WindOutageExposure