energy_analysis.pv_lifetime.study#

2025 field evidence and 2026 methods for a reproducible 50-year PV study.

energy_analysis.pv_lifetime.study.provenance()[source]#

Source identities, licenses, hashes and unresolved version differences.

Return type:

dict

energy_analysis.pv_lifetime.study.module_evidence()[source]#

All 32 archived module records, retaining exclusions and missing ratings.

Normalization is measured STC Pmax / workbook nameplate Pmax, not a measured before/after degradation ratio. Exposure uses the workbook’s own dates.

Return type:

DataFrame

energy_analysis.pv_lifetime.study.system_evidence()[source]#

Archived system PLRs and reported CIs, kept separate from module power.

Return type:

DataFrame

energy_analysis.pv_lifetime.study.field_anchors()[source]#

Group medians for the 14 rated field samples with >=30 documented years.

Return type:

DataFrame

energy_analysis.pv_lifetime.study.field_projections()[source]#

One-point, nameplate-anchored scenarios, starting at each measured age.

Linear: d=(1-Pa)/a, P(t)=Pa-d*(t-a). Exponential: k=-log(Pa)/a, P(t)=Pa*exp(-k*(t-a)). These average-to-date slopes do not estimate a measured instantaneous rate, and are not fits to longitudinal module data.

Return type:

DataFrame

energy_analysis.pv_lifetime.study.shape_scenarios()[source]#

Five hypothetical curves all passing through 90% at 30 years.

Return type:

DataFrame

energy_analysis.pv_lifetime.study.stress_scenarios()[source]#

Equivalent-time and independent-mode example; all parameters hypothetical.

Background exp(-0.001*t) times sigmoid corrosion with B=4. The corrosion rate is chosen to make combined power 0.9 at year 30. Multipliers change the rate, not temperature itself; they are not a climate forecast.

Return type:

DataFrame

energy_analysis.pv_lifetime.study.horizon_summary(curves)[source]#

30/40/50-year power and horizon-censored 80% crossing for scenario curves.

Parameters:

curves (DataFrame)

Return type:

DataFrame

energy_analysis.pv_lifetime.study.plot_measurements()[source]#

All rated field samples, including poorer outcomes and shorter exposures.

Return type:

Figure

energy_analysis.pv_lifetime.study.plot_system_rates()[source]#

System PLR evidence is not used as a module degradation coefficient.

Return type:

Figure

energy_analysis.pv_lifetime.study.plot_field_projections()[source]#

Constant-rate projections anchored at measured group medians.

Return type:

Figure

energy_analysis.pv_lifetime.study.plot_shape_scenarios()[source]#

One 30-year point cannot identify a 50-year degradation trajectory.

Return type:

Figure

energy_analysis.pv_lifetime.study.plot_stress_scenarios()[source]#

Variable stress preserves damage through equivalent-time updates.

Return type:

Figure

energy_analysis.pv_lifetime.study.plot_rate_thresholds()[source]#

Transparent linear-rate sensitivity in the requested 30-50-year window.

Return type:

Figure

energy_analysis.pv_lifetime.study.run_study(output)[source]#

Write six PNGs, a six-page PDF, seven CSVs and a provenance manifest.

Parameters:

output (Path)

Return type:

dict

energy_analysis.pv_lifetime.study.main()[source]#
Return type:

int