energy_analysis.pv_lifetime.study#
2025 field evidence and 2026 methods for a reproducible 50-year PV study.
- energy_analysis.pv_lifetime.study.provenance()[source]#
Source identities, licenses, hashes and unresolved version differences.
- Return type:
dict
- energy_analysis.pv_lifetime.study.module_evidence()[source]#
All 32 archived module records, retaining exclusions and missing ratings.
Normalization is measured STC Pmax / workbook nameplate Pmax, not a measured before/after degradation ratio. Exposure uses the workbook’s own dates.
- Return type:
DataFrame
- energy_analysis.pv_lifetime.study.system_evidence()[source]#
Archived system PLRs and reported CIs, kept separate from module power.
- Return type:
DataFrame
- energy_analysis.pv_lifetime.study.field_anchors()[source]#
Group medians for the 14 rated field samples with >=30 documented years.
- Return type:
DataFrame
- energy_analysis.pv_lifetime.study.field_projections()[source]#
One-point, nameplate-anchored scenarios, starting at each measured age.
Linear: d=(1-Pa)/a, P(t)=Pa-d*(t-a). Exponential: k=-log(Pa)/a, P(t)=Pa*exp(-k*(t-a)). These average-to-date slopes do not estimate a measured instantaneous rate, and are not fits to longitudinal module data.
- Return type:
DataFrame
- energy_analysis.pv_lifetime.study.shape_scenarios()[source]#
Five hypothetical curves all passing through 90% at 30 years.
- Return type:
DataFrame
- energy_analysis.pv_lifetime.study.stress_scenarios()[source]#
Equivalent-time and independent-mode example; all parameters hypothetical.
Background exp(-0.001*t) times sigmoid corrosion with B=4. The corrosion rate is chosen to make combined power 0.9 at year 30. Multipliers change the rate, not temperature itself; they are not a climate forecast.
- Return type:
DataFrame
- energy_analysis.pv_lifetime.study.horizon_summary(curves)[source]#
30/40/50-year power and horizon-censored 80% crossing for scenario curves.
- Parameters:
curves (DataFrame)
- Return type:
DataFrame
- energy_analysis.pv_lifetime.study.plot_measurements()[source]#
All rated field samples, including poorer outcomes and shorter exposures.
- Return type:
Figure
- energy_analysis.pv_lifetime.study.plot_system_rates()[source]#
System PLR evidence is not used as a module degradation coefficient.
- Return type:
Figure
- energy_analysis.pv_lifetime.study.plot_field_projections()[source]#
Constant-rate projections anchored at measured group medians.
- Return type:
Figure
- energy_analysis.pv_lifetime.study.plot_shape_scenarios()[source]#
One 30-year point cannot identify a 50-year degradation trajectory.
- Return type:
Figure
- energy_analysis.pv_lifetime.study.plot_stress_scenarios()[source]#
Variable stress preserves damage through equivalent-time updates.
- Return type:
Figure
- energy_analysis.pv_lifetime.study.plot_rate_thresholds()[source]#
Transparent linear-rate sensitivity in the requested 30-50-year window.
- Return type:
Figure