energy_methods.wildlife_curtailment#

Offline screening of wind-energy loss versus a proxy for wildlife exposure.

The proxy is bird/bat activity-index hours while the rotor would operate. It is not collision probability or avoided mortality. Within each time step, partial shutdown represents a fraction of the interval spent stopped.

class energy_methods.wildlife_curtailment.WildlifeCurtailmentScreen(baseline_energy_mwh, delivered_energy_mwh, curtailed_energy_mwh, exposure_before_index_hours, exposure_after_index_hours, proxy_reduction_fraction)[source]#

Bases: object

Energy in MWh; exposure in arbitrary activity-index hours.

Parameters:
  • baseline_energy_mwh (float)

  • delivered_energy_mwh (float)

  • curtailed_energy_mwh (float)

  • exposure_before_index_hours (float)

  • exposure_after_index_hours (float)

  • proxy_reduction_fraction (float)

baseline_energy_mwh: float#
delivered_energy_mwh: float#
curtailed_energy_mwh: float#
exposure_before_index_hours: float#
exposure_after_index_hours: float#
proxy_reduction_fraction: float#
energy_methods.wildlife_curtailment.screen_wildlife_curtailment(power_mw, activity_index, shutdown_fraction, *, timestep_hours=1.0)[source]#

Account for wind output and activity-weighted rotor-operating time.

This linear risk proxy is an illustrative screening assumption, not a validated link between radar activity and wildlife collisions. If the baseline wind power is zero, the model assumes the rotor is not operating.

Parameters:
  • power_mw (Sequence[float])

  • activity_index (Sequence[float])

  • shutdown_fraction (Sequence[float])

  • timestep_hours (float)

Return type:

WildlifeCurtailmentScreen

energy_methods.wildlife_curtailment.min_energy_loss_schedule(power_mw, activity_index, target_proxy_reduction, *, timestep_hours=1.0)[source]#

Minimize energy lost for a target activity-exposure proxy reduction.

Solves a continuous, linear fractional-knapsack problem: rank positive power/activity intervals by incremental MWh per index-hour and curtail cheapest first. Fractional interval shutdown is allowed; this does not optimize binary turbine stops or real ecological safety constraints.

Parameters:
  • power_mw (Sequence[float])

  • activity_index (Sequence[float])

  • target_proxy_reduction (float)

  • timestep_hours (float)

Return type:

tuple[float, …]