How much customer power can a lunar utility commit?#
Astrolab’s November 4, 2026 LUMIS announcement motivates screening continuous power-service commitments. Its ratings and endurance are design claims, not flight-verified customer delivery. Source: https://www.astrolab.space/2026/11/04/astrolab-unveils-lumis-power-and-communications-node-for-lunar-operations/
All battery sizes, housekeeping, delivery losses and illumination intervals below are assumptions. The 400-hour dark interval is a synthetic stress case, not a measured lunar site or a verified interpretation of the reserve claim.
from pathlib import Path
import matplotlib.pyplot as plt
from orbitalpv.data import load_table
from orbitalpv.physics import BatterySpec
from orbitalpv.utility import screen_power_service
directory = Path(__file__).resolve().parent if "__file__" in globals() else Path.cwd()
cases = load_table(directory / "_data/lunar_utility_cases.csv")
fig, axes = plt.subplots(1, 2, figsize=(11, 5), layout="constrained")
labels, limits = [], []
for row in cases.to_dict("records"):
battery = BatterySpec(
float(row["battery_wh"]),
initial_soc=0.9,
minimum_soc=0.2,
maximum_soc=0.95,
max_charge_w=20000,
max_discharge_w=20000,
)
result = screen_power_service(
[0, row["dark_h"] * 3600, (row["dark_h"] + row["sun_h"]) * 3600],
[0, row["pv_w"]],
50,
list(range(13)),
customer_power_w=50,
delivery_efficiency=0.9,
battery=battery,
)
feasible = result[result.repeatable_profile_feasible]
limit = int(feasible.customers.max()) if len(feasible) else 0
labels.append(row["scenario"])
limits.append(limit)
axes[1].plot(result.customers, result.unserved_bus_wh / 1000, marker=".", label=row["scenario"])
print(f"{row['scenario']}: {limit} continuous 50 W customers within candidate grid")
axes[0].bar(labels, limits, color=["#167d9a", "#e7ae4c", "#5a9461", "#9467bd"])
axes[0].set(ylabel="Admissible continuous 50 W customers", title="Modeled service commitments")
axes[0].tick_params(axis="x", labelrotation=28)
axes[1].set(
xlabel="Requested customers",
ylabel="Unserved utility-bus energy [kWh]",
title="Overcommitment exposes shortfall",
)
axes[1].legend(fontsize=8)
axes[1].grid(alpha=0.2)
plt.show()

Reference node: 2 continuous 50 W customers within candidate grid
Larger PV only: 2 continuous 50 W customers within candidate grid
Larger storage: 6 continuous 50 W customers within candidate grid
Shorter dark interval: 6 continuous 50 W customers within candidate grid
Increasing the PV rating alone cannot cover additional dark-interval energy. The method also rejects initially charged storage that fails to recharge. Demand is screened in aggregate: unmet energy is not assigned to customers or housekeeping. These are conditional capacity limits, not tariff advice, actual LUMIS specifications, guaranteed service levels or reliability estimates.
Total running time of the script: (0 minutes 0.241 seconds)