Note
Go to the end to download the full example code.
BESS OEM products: specifications, coverage and evidence#
Build the source-backed OEM catalogue offline, query product configurations and inspect evidence completeness. This is a product research inventory, not a market share ranking, independent performance test or procurement recommendation.
Explore the same rows in the BESS OEM viewer. Exact supplier/model/variant identity is separate from mutable specifications.
from pathlib import Path
from tempfile import TemporaryDirectory
import matplotlib.pyplot as plt
import pandas as pd
from energy_analysis.pv_database import field_profile
from energy_data_retrieval.bess_oem_catalogue import build_parquet
ROOT = next(p for p in (Path.cwd(), *Path.cwd().parents) if (p / "catalogues/bess_oem").is_dir())
with TemporaryDirectory() as folder:
snapshot = Path(folder) / "bess_oem"
manifest = build_parquet(ROOT / "catalogues/bess_oem", snapshot)
systems = pd.read_parquet(snapshot / "systems.parquet")
completeness = field_profile(snapshot / "systems.parquet")
print(f"{len(systems)} records from {systems['manufacturer'].nunique()} suppliers")
print("Input fingerprint:", manifest["input_sha256"])
print("Configurations and families:")
print(systems.groupby(["manufacturer", "record_scope"]).size().unstack(fill_value=0).to_string())
1630 records from 64 suppliers
Input fingerprint: ca27d594c8359d61b419d85f8022414ba443de243b6919ebe771b506d3dd6280
Configurations and families:
record_scope configuration family
manufacturer
ATESS 50 0
AlphaESS 18 0
BSB Power 59 0
BSLBATT 54 0
BYD 28 0
BlueNova 45 0
CATL 3 1
Canadian Solar e-STORAGE 1 1
Crown Battery 31 0
Deye ESS 6 0
Discover Battery 11 0
Dyness 37 0
EFFEKTA 39 0
EPC Power 5 0
ESS Inc. 1 2
EVE Energy 1 0
Elum Energy 8 0
Envision Energy 2 0
Eos Energy Enterprises 1 0
Fluence 2 1
Fox ESS 37 0
Freedom Won 62 0
Fullriver Battery 48 0
GoodWe 22 0
HiTHIUM 3 0
Huawei 2 0
Hubble Energy 22 0
HyperStrong 2 0
INTILION 8 0
Ingeteam 21 0
Invinity Energy Systems 1 3
Jinko ESS 1 0
Kehua 38 0
LEOCH 30 0
LG Energy Solution 3 0
Megarevo 31 0
Microcare 17 0
NGK Insulators 1 0
Narada Power 30 0
Neata 110 0
Nidec Conversion 8 0
Pixii 6 0
Pylontech 45 0
REPT BATTERO 1 0
Renon Power 41 0
Ritar 78 0
Rolls Battery 92 0
Rolls-Royce Power Systems mtu 0 3
SMA Solar Technology AG 3 0
Saft 3 0
Samsung SDI 2 0
Sinexcel 33 0
Socomec 0 2
SolaX Power 23 0
Solar MD 35 0
Solis 25 0
Studer Innotec 26 0
Sungrow 22 0
TAB 108 0
TESVOLT 23 0
Tesla 2 0
Trina Storage 3 0
Victron Energy 146 0
Wärtsilä 1 0
Model strings are not specifications: the ST225kWh model has a source-reported nominal capacity of 229 kWh. Other PowerTitan variants have separate dates and regional ratings. Inspect all evidence before selecting an engineering value.
columns = [
"model",
"variant",
"energy_capacity_mwh",
"energy_basis",
"energy_boundary",
"power_capacity_mw",
"power_basis",
"apparent_power_mva",
"product_status",
]
print("Sungrow source variants:")
print(systems.loc[systems["manufacturer"].eq("Sungrow"), columns].to_string(index=False))
example = systems.loc[systems["model"].eq("ST225kWh-110kW-2h")].iloc[0]
print("Exact sources:", list(example["source_urls"]))
print("Per-field evidence:", example["field_sources_json"])
Sungrow source variants:
model variant energy_capacity_mwh energy_basis energy_boundary power_capacity_mw power_basis apparent_power_mva product_status
PowerTitan 3.0 Flex; 10ft; 2025 launch 3.4500 unspecified unspecified NaN None NaN documented
SBH100 Spanish datasheet v3.1 0.0100 usable dc 0.00704 dc NaN documented
SBR192 Spanish datasheet v13 0.0192 usable dc 0.01152 dc NaN documented
SBH250 Spanish datasheet v3.1 0.0250 usable dc 0.01760 dc NaN documented
SBR160 Spanish datasheet v13 0.0160 usable dc 0.00960 dc NaN documented
SBR224 Spanish datasheet v13 0.0224 usable dc 0.01344 dc NaN documented
SBR128 Spanish datasheet v13 0.0128 usable dc 0.00768 dc NaN documented
ST5015kWh-2500kW-2h PowerTitan 2.0; V3 5.0150 nominal dc NaN None 2.52 documented
ST6900UX-4H PowerTitan 3.0; preliminary V3 6.9040 nominal dc NaN None 1.80 preliminary
ST5015kWh-1250kW-4h PowerTitan 2.0; V3 5.0150 nominal dc NaN None 1.26 documented
SBH300 Spanish datasheet v3.1 0.0300 usable dc 0.02112 dc NaN documented
SBH150 Spanish datasheet v3.1 0.0150 usable dc 0.01056 dc NaN documented
SBH400 Spanish datasheet v3.1 0.0400 usable dc 0.02816 dc NaN documented
SBH200 Spanish datasheet v3.1 0.0200 usable dc 0.01408 dc NaN documented
PowerTitan 3.0 Plus; 30ft; 2025 launch 12.5000 unspecified unspecified NaN None NaN documented
ST255CS-2H PowerStack 255CS; IEC 0.2570 unspecified unspecified 0.12500 ac NaN documented
SBR256 Spanish datasheet v13 0.0256 usable dc 0.01536 dc NaN documented
SBR096 Spanish datasheet v13 0.0096 usable dc 0.00576 dc NaN documented
SBH350 Spanish datasheet v3.1 0.0350 usable dc 0.02464 dc NaN documented
PowerTitan 3.0 Europe; 20ft 7.14 MWh; 2026 launch 7.1400 unspecified unspecified 1.78000 ac NaN documented
ST225kWh-110kW-2h PowerStack; EUR/APAC V3 0.2290 nominal dc 0.11000 ac NaN documented
PowerTitan 3.0 Class; 20ft; 2025 launch 6.9000 unspecified unspecified NaN None NaN documented
Exact sources: ['https://uk.sungrowpower.com/upload/file/20250226/EN_DS_ST225kWh-110kW-2h_PowerStack_Datasheet.pdf']
Per-field evidence: {"ac_voltage_v":["sungrow_powerstack_225_v3"],"altitude_max_m":["sungrow_powerstack_225_v3"],"architecture":["sungrow_powerstack_225_v3"],"capacity_scope":["sungrow_powerstack_225_v3"],"cell_capacity_ah":["sungrow_powerstack_225_v3"],"chemistry":["sungrow_powerstack_225_v3"],"communication_interfaces":["sungrow_powerstack_225_v3"],"communication_protocols":["sungrow_powerstack_225_v3"],"cooling":["sungrow_powerstack_225_v3"],"dc_voltage_max_v":["sungrow_powerstack_225_v3"],"dc_voltage_min_v":["sungrow_powerstack_225_v3"],"depth_m":["sungrow_powerstack_225_v3"],"derating_notes":["sungrow_powerstack_225_v3"],"energy_basis":["sungrow_powerstack_225_v3"],"energy_boundary":["sungrow_powerstack_225_v3"],"energy_capacity_mwh":["sungrow_powerstack_225_v3"],"height_m":["sungrow_powerstack_225_v3"],"ingress_protection":["sungrow_powerstack_225_v3"],"manufacturer":["sungrow_powerstack_225_v3"],"market_scope":["sungrow_powerstack_225_v3"],"market_segment":["sungrow_powerstack_225_v3"],"model":["sungrow_powerstack_225_v3"],"name":["sungrow_powerstack_225_v3"],"operating_temperature_max_c":["sungrow_powerstack_225_v3"],"operating_temperature_min_c":["sungrow_powerstack_225_v3"],"pcs_included":["sungrow_powerstack_225_v3"],"power_basis":["sungrow_powerstack_225_v3"],"power_capacity_mw":["sungrow_powerstack_225_v3"],"power_rating_kind":["sungrow_powerstack_225_v3"],"product_status":["sungrow_powerstack_225_v3"],"record_scope":["sungrow_powerstack_225_v3"],"variant":["sungrow_powerstack_225_v3"],"weight_kg":["sungrow_powerstack_225_v3"],"width_m":["sungrow_powerstack_225_v3"]}
A reproducible screening query uses only explicitly documented configurations, nominal DC energy and LFP chemistry. A size screen is not a compatibility check.
screen = systems.loc[
systems["record_scope"].eq("configuration")
& systems["product_status"].eq("documented")
& systems["chemistry"].eq("LFP")
& systems["energy_basis"].eq("nominal")
& systems["energy_boundary"].eq("dc")
& systems["energy_capacity_mwh"].ge(5)
]
print("Documented configurations with nominal DC energy >= 5 MWh and reported LFP:")
print(screen[["manufacturer", *columns]].to_string(index=False))
Documented configurations with nominal DC energy >= 5 MWh and reported LFP:
manufacturer model variant energy_capacity_mwh energy_basis energy_boundary power_capacity_mw power_basis apparent_power_mva product_status
Nidec Conversion ACBOX V4 16 racks; 4h; July 2026 edition 6.70000 nominal dc NaN None 2.02 documented
HyperStrong HSL3C721-05015 HyperBlock III; 5 MWh AC 5.01596 nominal dc 2.5 ac NaN documented
Nidec Conversion ACBOX V3 2h configuration; 04-2025 REV-001 5.03000 nominal dc NaN None 2.47 documented
REPT BATTERO Powtrix 3.0 6.261 MWh; 2025 datasheet 6.26100 nominal dc NaN None NaN documented
Trina Storage Elementa 2 5.015 MWh DC; 2024 datasheet 5.01500 nominal dc NaN None NaN documented
Sungrow ST5015kWh-2500kW-2h PowerTitan 2.0; V3 5.01500 nominal dc NaN None 2.52 documented
HiTHIUM ∞Power 6.25 MWh 4h US; April 2026 document 6.25000 nominal dc NaN None NaN documented
HyperStrong HSL3C700-05015 HyperBlock III; 5 MWh DC 5.01596 nominal dc 2.5 dc NaN documented
Sungrow ST5015kWh-1250kW-4h PowerTitan 2.0; V3 5.01500 nominal dc NaN None 1.26 documented
Nidec Conversion ACBOX V3 4h configuration; 04-2025 REV-001 8.46600 nominal dc NaN None 2.47 documented
Nidec Conversion ACBOX V4 20 racks; 4h; July 2026 edition 8.38000 nominal dc NaN None 2.52 documented
Nidec Conversion ACBOX V4 12 racks; 4h; July 2026 edition 5.03000 nominal dc NaN None 1.50 documented
Nidec Conversion ACBOX V3 8h configuration; 04-2025 REV-001 8.46600 nominal dc NaN None 1.23 documented
Plot coverage rather than summing product capacities. Multiple generations and configurations do not represent installed systems. Families have no scalar MW/MWh.
fields = [
"energy_capacity_mwh",
"power_capacity_mw",
"apparent_power_mva",
"chemistry",
"cooling",
"round_trip_efficiency_pct",
"cycle_life",
"warranty_years",
]
fig, axes = plt.subplots(1, 2, figsize=(14, 10), layout="constrained")
coverage = systems.groupby(["manufacturer", "record_scope"]).size().unstack(fill_value=0)
coverage = coverage.reindex(coverage.sum(axis=1).sort_values().index)
coverage.plot.barh(stacked=True, color=["#167d9a", "#d59c39"], ax=axes[0])
axes[0].set(xlabel="Catalogue records", ylabel="", title="Supplier coverage; not market share")
axes[0].legend(title="Record scope", fontsize=8)
known = systems[fields].notna().sum()
pd.DataFrame({"Reported": known, "Unknown": len(systems) - known}).plot.barh(
stacked=True, color=["#167d9a", "#dfe5e9"], ax=axes[1]
)
axes[1].set(xlabel="Records", ylabel="", title="Field coverage, including families")
fig.suptitle("BESS OEM research catalogue · product specifications with provenance")
plt.show()

RTE conditions differ between products; do not rank percentages without matching boundary, qualifier, duty cycle and auxiliary-load treatment. MVA remains separate from active MW, and family ranges are available in extensions_json.
print("RTE claims and their qualifications:")
print(
systems.loc[
systems["round_trip_efficiency_pct"].notna(),
[
"manufacturer",
"model",
"round_trip_efficiency_pct",
"efficiency_boundary",
"efficiency_qualifier",
"efficiency_conditions",
],
].to_string(index=False)
)
print("Technical-field completeness:")
print(completeness.loc[fields].to_string())
RTE claims and their qualifications:
manufacturer model round_trip_efficiency_pct efficiency_boundary efficiency_qualifier efficiency_conditions
Victron Energy Lithium NG 12.8 V/150 Ah 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
SolaX Power T-BAT HS20.0 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Victron Energy Lithium NG 12.8 V/100 Ah 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
Fox ESS ECS2900-H5 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS ECS4800-H5 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
SolaX Power T-BAT HS10.8 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Victron Energy Lithium NG 25.6 V/300 Ah 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
SolaX Power T-BAT HS15.0 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Fox ESS ECS4300H-H4 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS ECS4800-H4 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS ECS4300H-H5 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS ECS2900-H6 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS ECS4300H-H2 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
SolaX Power T-BAT HS39.6 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Tesla Megapack 92.0 system_unspecified reported Configurator does not state test conditions or auxiliary boundary.
Victron Energy Lithium Battery Smart 12.8/50 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
SolaX Power T-BAT HS36.0 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Fox ESS ECS2900-H4 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
SolaX Power T-BAT HS32.5 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Fox ESS EQ3300-L2 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Fox ESS ECS4300H-H3 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS EQ4800-L3 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Fox ESS ECS4300H-H7 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS EQ4800-L2 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Victron Energy Lithium NG 25.6 V/200 Ah 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
SolaX Power T-BAT HS27.5 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
SolaX Power T-BAT HS10.0 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Fox ESS ECS4800-H2 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS ECS4300H-H6 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS ECS2800-H7 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Victron Energy Lithium Battery Smart 12.8/330 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
Fox ESS EQ4800-L8 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Victron Energy Lithium NG 12.8 V/200 Ah 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
HiTHIUM ∞Power 95.0 unspecified minimum 0.25P charge/discharge at 25 +/-2 degC; auxiliary boundary not explicit.
Victron Energy Lithium Battery Smart 25.6/100 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
ATESS MatrixOne IC418-690 92.0 system_unspecified maximum Manufacturer maximum; AC/DC measurement endpoints, auxiliary treatment and test conditions unspecified.
Fox ESS EQ3300-L4 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Fox ESS ECS2800-H3 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
SolaX Power T-BAT HS7.5 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
SolaX Power T-BAT HS28.8 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Victron Energy Lithium Battery Smart 12.8/100 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
Fox ESS EQ3300-L5 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Fox ESS EQ4800-L7 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Fox ESS ECS4800-H6 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS ECS4800-H7 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
SolaX Power T-BAT HS7.2 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Victron Energy Lithium NG 12.8 V/300 Ah 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
Fox ESS ECS2800-H4 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Victron Energy Lithium NG 25.6 V/100 Ah 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
SolaX Power T-BAT HS18.0 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Fox ESS EQ4800-L5 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
SolaX Power T-BAT HS14.4 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Jinko ESS SunTera G3 95.0 unspecified reported Press release does not state test boundary or duty cycle.
SolaX Power T-BAT HS46.8 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Victron Energy Lithium Battery Smart 25.6/200-a 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
SolaX Power T-BAT HS5.0 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
SolaX Power T-BAT HS21.6 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Sungrow ST255CS-2H 90.0 system_unspecified reported Product page states system RTE; detailed duty cycle not given.
SolaX Power T-BAT HS17.5 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Fox ESS ECS4800-H3 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS EQ4800-L9 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Victron Energy Lithium NG 51.2 V/100 Ah 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
Huawei LUNA2000-241-2S1 91.3 system_unspecified maximum Rated condition: on-grid, 25 degC, 400 Vac; page calls this maximum cycle efficiency.
SolaX Power T-BAT HS25.0 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Fox ESS EQ4800-L4 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Fox ESS ECS2900-H2 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS ECS2800-H2 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS ECS2800-H6 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS EQ3300-L6 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Fox ESS EQ4800-L6 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Victron Energy Lithium Battery Smart 12.8/200 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
SolaX Power T-BAT HS25.2 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Victron Energy Lithium Battery Smart 12.8/160 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
ATESS MatrixOne IC418-800 92.0 system_unspecified maximum Manufacturer maximum; AC/DC measurement endpoints, auxiliary treatment and test conditions unspecified.
Fox ESS EQ3300-L3 95.0 dc_dc minimum Manufacturer states battery-pack round-trip efficiency strictly greater than 95%; test conditions and auxiliary treatment unspecified; not AC-to-AC system efficiency.
Sungrow PowerTitan 3.0 92.0 system_unspecified reported Launch claim; detailed measurement procedure not given.
SolaX Power T-BAT HS43.2 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
SolaX Power T-BAT HS30.0 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
ATESS MatrixOne IC261-400S 92.0 system_unspecified maximum Manufacturer maximum; AC/DC measurement endpoints, auxiliary treatment and test conditions unspecified.
Fox ESS ECS2800-H5 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Fox ESS ECS2900-H7 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
SolaX Power T-BAT HS12.5 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
SolaX Power T-BAT HS32.4 95.0 dc_dc reported Battery round-trip efficiency at 0.2C and 25°C; not AC-to-AC system efficiency.
Fox ESS ECS2900-H3 95.0 dc_dc minimum Strictly greater than 95% battery-pack RTE; test conditions/auxiliary treatment unspecified; not AC system RTE.
Victron Energy Lithium Battery Smart 12.8/180 92.0 unspecified reported Battery manual claim; measurement boundary and auxiliary treatment unspecified; not AC-to-AC.
Tesla Megapack 93.7 system_unspecified reported Configurator does not state test conditions or auxiliary boundary.
Technical-field completeness:
type unit known missing coverage_pct
field
energy_capacity_mwh double MWh 620 1010 38.036810
power_capacity_mw double MW 503 1127 30.858896
apparent_power_mva double MVA 222 1408 13.619632
chemistry string 1064 566 65.276074
cooling string 552 1078 33.865031
round_trip_efficiency_pct double % 86 1544 5.276074
cycle_life double cycles 187 1443 11.472393
warranty_years double years 328 1302 20.122699
Total running time of the script: (0 minutes 0.722 seconds)