Note
Go to the end to download the full example code.
Wind: historical coverage, capacity boundaries and exact turbine specifications#
Rebuild the connected catalogue offline. Historical WRI coverage is not a current operating census. Capacity charts exclude parent totals and unresolved scopes and keep lifecycle states separate. Manufacturer specifications and calculated curves are not independently validated field performance. See the interactive wind viewer for field-level evidence.
import json
from pathlib import Path
from tempfile import TemporaryDirectory
import matplotlib.pyplot as plt
import pandas as pd
import pyarrow.parquet as pq
from energy_analysis.wind_database import compatible_curves, specific_power_w_m2
from energy_data_retrieval.wind_catalogue import build_parquet, capacity_summary
ROOT = next(p for p in (Path.cwd(), *Path.cwd().parents) if (p / "catalogues/wind").is_dir())
# Detailed provenance remains in canonical records, Parquet and the shared
# viewer. These plots do not need duplicate copies of those large JSON columns.
PROVENANCE = {"evidence_json", "field_sources_json"}
with TemporaryDirectory() as folder:
snapshot = Path(folder) / "wind"
manifest = build_parquet(ROOT / "catalogues/wind", snapshot)
columns = [
name
for name in pq.read_schema(snapshot / "projects.parquet").names
if name not in PROVENANCE
]
projects = pd.read_parquet(snapshot / "projects.parquet", columns=columns)
equipment = pd.read_parquet(snapshot / "equipment.parquet", columns=columns)
rows = []
for path in sorted((ROOT / "catalogues/wind/records").rglob("*.jsonl")):
with path.open() as stream:
for line in stream:
if not line.strip():
continue
row = json.loads(line)
rows.append({key: value for key, value in row.items() if key not in PROVENANCE})
rows.sort(key=lambda row: row["record_id"])
print("Input fingerprint:", manifest["input_sha256"])
print("Country-level coverage (includes historical and aggregate records):")
print(projects.groupby(["country_code", "aggregation_role"]).size().unstack(fill_value=0))
print("Technology coverage:", projects.technology.value_counts().to_dict())
print("Dated lifecycle versus aggregation scope (known status does not resolve overlap):")
print(projects.groupby(["status", "aggregation_role"]).size().unstack(fill_value=0))
print("Equipment categories (components are not turbines):")
print(equipment.groupby(["manufacturer", "equipment_category"]).size())
# Explicit blade configurations preserve root geometry independently of rotors.
print("Blade table configurations: length/root pitch-circle in m; certification is an OEM claim")
for component in rows:
blade = json.loads(component.get("extensions_json") or "{}")
if "blade_table_observations" in blade:
print(
component["model"],
component["variant"],
component["blade_length_m"],
blade["root_pitch_circle_diameter_m"],
blade["certification_claim"],
"Exact turbine application unknown; no rotor diameter inferred",
)
# Reported proposal MW stays independent of count times unit rating.
print("Fleet rating arithmetic checks; no installed MW or aggregation eligibility inferred")
for row in rows:
check = json.loads(row.get("extensions_json") or "{}").get("fleet_rating_check")
if check:
print(row["name"], check, row["aggregation_role"])
# Proposal revisions and derating retain their own dates and quantity boundaries.
print("Dated proposal boundaries: reported MW, derating and mandatory removals")
for row in rows:
proposal = json.loads(row.get("extensions_json") or "{}").get("dated_proposal_observation")
if proposal:
print(
row["name"],
proposal["publication_date"],
"planned MW:",
row.get("planned_capacity_mw"),
"rating check MW:",
proposal.get("arithmetic_check_mw"),
"required removals:",
proposal.get("required_turbine_removals"),
"aggregation:",
row["aggregation_role"],
)
print("None means unknown; original mixed-fleet designs are not revised layouts.")
# The NEM survey keeps mixed states and shared hybrid limits out of scalar totals.
print("AEMO wind-only survey sites: unknown geometry and excluded capacity scopes")
for row in rows:
ext = json.loads(row.get("extensions_json") or "{}")
if "capacity_by_aemo_status" in ext:
print(row["name"], ext["capacity_by_aemo_status"], row["aggregation_role"])
# Registry unit evidence does not resolve farm boundaries or missing farm MW.
eia_projects = [
row
for row in rows
if row["entity_type"] == "projects"
and json.loads(row.get("extensions_json") or "{}").get("eia_annual_wind_partitions")
]
print(
"EIA evidence: project counts, not capacity totals",
{
"projects": len(eia_projects),
"unresolved_scope": sum(row["aggregation_role"] == "unresolved" for row in eia_projects),
"unknown_installed_mw": sum(
row.get("installed_capacity_mw") is None for row in eia_projects
),
},
)
print("Published turbine power ratings require their measurement conditions")
print(
equipment.loc[
equipment.sources.apply(lambda v: "pnnl_small_wind_july2026" in v),
["model", "rated_power_kw", "rated_power_conditions", "rotor_diameter_m"],
]
)
# Published rotor geometry is independent of the digits in an OEM model name.
print("Goldwind complete named columns: geometry, power conditions and offered hubs")
print(
equipment.loc[
equipment.manufacturer.eq("Goldwind"),
[
"model",
"rated_power_kw",
"rotor_diameter_m",
"swept_area_m2",
"rated_power_conditions",
"hub_height_options_json",
],
].to_string(index=False)
)
print("Hub options do not create model variants; no common-condition power curves inferred.")
# Announced modes and tower approvals remain dated options on the existing model.
print("Dated OEM product updates: modes and approval timing, not installed variants")
for row in rows:
for update in json.loads(row.get("extensions_json") or "{}").get("oem_product_updates", []):
print(row["name"], update["published_at"], update["operating_modes"])
print(update["tower_configurations"], update["conditions"])
# Retrospective prototype and production facts retain dates and exact model links.
print("OEM historical observations: not current configuration or fleet retirement")
for row in rows:
for observation in json.loads(row.get("extensions_json") or "{}").get(
"oem_historical_observations", []
):
print(row["model"], observation["published_at"], observation["boundary"])
print(observation["facts"])
# Reference yields are hypothetical five-year energy, never farm generation.
reference_counts = {}
reference_unknown_rotor = 0
reference_corrections = 0
for row in rows:
for observation in json.loads(row.get("extensions_json") or "{}").get(
"reference_yield_observations", []
):
for entry in observation["rows"]:
reference_unknown_rotor += entry.get("rotor_diameter_m") is None
reference_corrections += entry.get("corrected_at") is not None
key = (observation["reference_site"], entry.get("withdrawn", False))
reference_counts[key] = reference_counts.get(key, 0) + 1
print("FGW observation counts by reference site and withdrawn status:")
print(dict(sorted(reference_counts.items())))
print("Reference observations with unknown rotor diameter:", reference_unknown_rotor)
print("Dated reference-yield corrections, not commissioning:", reference_corrections)
print("Reference yields retain five-year kWh, hub/power settings and source notes.")
print(
"Density, operating mode and gross/net boundary are unknown; no CF or performance comparison."
)
# Dated issuer listings retain expired and unknown status; options are not variants.
certification_status = {}
for row in rows:
for observation in json.loads(row.get("extensions_json") or "{}").get(
"certification_register_observations", []
):
status = observation.get("registry_status", "unspecified")
certification_status[status] = certification_status.get(status, 0) + 1
print(
"Certification registry observations by stated status:",
dict(sorted(certification_status.items())),
)
print("Unspecified status does not establish current validity; listed date is not commissioning.")
# Annual EIA unit states do not reconcile whole-farm repowering or hybrid scope.
print("EIA 2025 dated unit evidence: farm status/capacity exclusions remain unchanged")
for row in rows:
for partition in json.loads(row.get("extensions_json") or "{}").get(
"eia_annual_wind_partitions", []
):
states = [unit["status_code"] for unit in partition["units"]]
print(
row["name"],
partition["plant_code"],
partition["year"],
states,
row["status"],
row["aggregation_role"],
)
print("Predominant models and representative heights are partial inventories, not exact fleets.")
# Compare observation counts within reporting years, never sum MW across years.
eia_years = {}
for row in rows:
for partition in json.loads(row.get("extensions_json") or "{}").get(
"eia_annual_wind_partitions", []
):
counts = eia_years.setdefault(partition["year"], {})
for unit in partition["units"]:
state = unit["status_code"]
counts[state] = counts.get(state, 0) + 1
print("Dated EIA generator observations by reporting year:", dict(sorted(eia_years.items())))
# Environmental declarations use modeled sites, not independently observed farms.
print("EPD lifetime scenarios: separate model, location, exposure and net-to-grid boundary")
for row in rows:
declarations = json.loads(row.get("extensions_json") or "{}").get(
"environmental_product_declarations", []
)
for declaration in declarations:
for scenario in declaration["scenarios"]:
print(
row["model"],
scenario["location"],
scenario["reference_service_life_years"],
"years",
scenario["value"],
scenario["unit"],
scenario["kind"],
scenario["boundary"],
declaration["source_id"],
)
print("No scenario total, capacity factor, operating project or comparable curve is inferred.")
# Procedural decisions can concern solar or auxiliary equipment, not the wind farm.
print("BOE decision scope: wind lifecycle and capacity boundaries remain separate")
for row in rows:
procedure = json.loads(row.get("extensions_json") or "{}").get("boe_procedure")
if procedure:
print(
row["name"],
"decision target",
procedure["decision_target"],
"decision date",
procedure["decision_date"],
"wind status",
row["status"],
"status date",
row["status_as_of"],
"installed MW",
row.get("installed_capacity_mw"),
"planned MW",
row.get("planned_capacity_mw"),
"aggregation",
row["aggregation_role"],
"quarantined fields",
sorted(json.loads(row.get("conflicts_json") or "{}")),
)
# Follow only disclosed applications; component power is not turbine power.
by_id = {row["record_id"]: row for row in rows}
print("Explicit component applications and their conditions (not deployed fleets):")
for row in rows:
for link in json.loads(row.get("compatibility_json") or "[]"):
print(row["name"], "→", by_id[link["equipment_record_id"]]["name"], link["conditions"])
# Regional regulatory entries retain raw certificate dates and restrictions.
# Inclusion is not a current certificate or permission-to-operate conclusion.
print("India ALMM observations: dated listing, not verified current eligibility")
for row in rows:
almm = json.loads(row.get("extensions_json") or "{}").get("mnre_almm_india")
if almm:
for entry in almm["rows"]:
print(
row["model"],
"entry",
entry["row"],
"listed kW",
entry["ratings_kw"],
"hub options m",
entry["hub_heights_m"],
"certificate date as printed",
entry["certificate_validity_raw"],
"outstanding issue",
entry["outstanding_issue"],
"restriction",
entry["remarks"],
)
# French registry EICs describe network installations. A dated operating state
# and two reported ratings do not establish non-overlapping whole-farm scope.
french_registry = projects.loc[
projects.external_ids_json.fillna("").str.contains('"odre_eic"', regex=False)
]
if not french_registry.empty:
print("French network installations: dated capacity observations, excluded from totals")
print(
french_registry[
[
"name",
"region",
"status_as_of",
"installed_capacity_mw",
"export_capacity_mw",
"aggregation_role",
]
].to_string(index=False)
)
print("No surveyed coordinates inferred from French administrative geography.")
Input fingerprint: 803e59cfba7c6828ebbf4266a8ac8900bf1d7aa0078b771b8a68dbae8b6567f1
Country-level coverage (includes historical and aggregate records):
aggregation_role aggregate child independent unresolved
country_code
ARG 0 0 0 12
ATA 0 0 0 1
AUS 0 0 1 263
AUT 0 0 0 4
BEL 0 0 0 12
... ... ... ... ...
URY 0 0 0 39
USA 0 0 1 1255
UZB 0 0 0 1
VNM 0 0 0 5
ZAF 0 0 0 26
[64 rows x 4 columns]
Technology coverage: {'unknown': 4739, 'onshore': 3625, 'offshore_unspecified': 101, 'fixed_bottom_offshore': 20, 'floating_offshore': 5}
Dated lifecycle versus aggregation scope (known status does not resolve overlap):
aggregation_role aggregate child independent unresolved
status
announced 0 0 1 212
cancelled 0 0 0 754
commissioning 0 0 0 4
decommissioned 0 0 0 78
operational 1 2 11 882
partially_operational 0 0 1 0
permitted 0 0 0 43
under_construction 0 0 0 2
unknown 0 0 0 6499
Equipment categories (components are not turbines):
manufacturer equipment_category
ABB control 4
converter 36
lcl_filter 3
Acciona S.A. wind_turbine 1
Acciona Windpower wind_turbine 8
..
Windey wind_turbine 69
Winergy gearbox 2
Xi’an Chen’an Electric generator 1
ZF Wind Power gearbox 1
ebm-papst cooling_fan 1
Length: 87, dtype: int64
Blade table configurations: length/root pitch-circle in m; certification is an OEM claim
4.XMW-82 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m 82 2.8 鉴衡 Exact turbine application unknown; no rotor diameter inferred
4.XMW-76 Published OEM blade table 2022-03-03; wind class SC; root pitch-circle 2.8 m 76 2.8 鉴衡 Exact turbine application unknown; no rotor diameter inferred
3.XMW-76 Published OEM blade table 2022-03-03; wind class SC; root pitch-circle 2.8 m 76 2.8 鉴衡 Exact turbine application unknown; no rotor diameter inferred
2.XMW-64.5 Published OEM blade table 2021-07-22; wind class S; root pitch-circle 2.3 m 64.5 2.3 DNV.GL Exact turbine application unknown; no rotor diameter inferred
4.XMW-86 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m 86 2.8 鉴衡 Exact turbine application unknown; no rotor diameter inferred
4.XMW-80.5 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m 80.5 2.8 鉴衡 Exact turbine application unknown; no rotor diameter inferred
4.XMW-78 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m 78 2.8 鉴衡 Exact turbine application unknown; no rotor diameter inferred
2.0MW-59.5 Published OEM blade table 2021-07-22; wind class S; root pitch-circle 2.3 m 59.5 2.3 DNV.GL Exact turbine application unknown; no rotor diameter inferred
5.XMW-91 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 3.2 m 91 3.2 鉴衡 Exact turbine application unknown; no rotor diameter inferred
6.XMW-91 Published OEM blade table 2022-03-03; wind class SB; root pitch-circle 3.2 m 91 3.2 鉴衡 Exact turbine application unknown; no rotor diameter inferred
3.XMW-71.5 Published OEM blade table 2022-03-03; wind class SC; root pitch-circle 2.8 m 71.5 2.8 鉴衡 Exact turbine application unknown; no rotor diameter inferred
3.XMW-78 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m 78 2.8 鉴衡 Exact turbine application unknown; no rotor diameter inferred
3.XMW-80.5 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m 80.5 2.8 -鉴衡 Exact turbine application unknown; no rotor diameter inferred
4.XMW-72.5 Published OEM blade table 2022-03-03; wind class S; root pitch-circle 3.2 m 72.5 3.2 GL Exact turbine application unknown; no rotor diameter inferred
2.XMW-64.0 Published OEM blade table 2021-07-22; wind class S; root pitch-circle 2.3 m 64 2.3 鉴衡 Exact turbine application unknown; no rotor diameter inferred
4.XMW-84 Published OEM blade table 2022-03-03; wind class SC; root pitch-circle 2.8 m 84 2.8 None Exact turbine application unknown; no rotor diameter inferred
2.XMW-71.5 Published OEM blade table 2021-07-22; wind class S; root pitch-circle 2.8 m 71.5 2.8 鉴衡 Exact turbine application unknown; no rotor diameter inferred
3.XMW-82 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m 82 2.8 鉴衡 Exact turbine application unknown; no rotor diameter inferred
3.XMW-76 Published OEM blade table 2022-03-03; wind class SB; root pitch-circle 2.5 m 76 2.5 DNV.GL Exact turbine application unknown; no rotor diameter inferred
Fleet rating arithmetic checks; no installed MW or aggregation eligibility inferred
Desma {'calculated_mw': 27.12, 'difference_mw': 0.0, 'locator': 'BOE121 pp65785–65796; Segundo, wind characteristics and evacuation infrastructure', 'method': '6 times4.52MW authorized rating; arithmetic check, not reported capacity replacement', 'reported_mw': 27.12, 'source_id': 'BOE-A-2025-9955'} unresolved
Paucali {'calculated_mw': 63.0, 'difference_mw': 0.0, 'locator': 'Descripción de las Instalaciones; GREEN CAPITAL DEVELOPMENT XXXVII S.L.U.; PE Paucali and budget paragraphs', 'method': 'count times proposed unit rating; not a replacement for reported project MW', 'reported_mw': 63.0, 'source_id': 'BOE-B-2026-23315'} unresolved
Céfiro {'calculated_mw': 110.925, 'difference_mw': 0.025, 'locator': 'Descripción de las Instalaciones; GREEN CAPITAL DEVELOPMENT XLI S.L.U.; PE Céfiro and budget paragraphs', 'method': 'count times proposed unit rating; not a replacement for reported project MW', 'reported_mw': 110.9, 'source_id': 'BOE-B-2026-23315'} unresolved
Waad Al-Shamal {'calculated_mw': 515.9, 'difference_mw': 15.9, 'locator': 'PDFpage4 design table; page3 introduction for Al Ghat / page4 introduction for Waad', 'method': 'NTS design count times7.7MW compared with NTS table MW; not installed/export capacity', 'reported_mw': 500.0, 'source_id': 'axia-waad-nts-doc02'} unresolved
Arlo {'calculated_mw': 65.25, 'difference_mw': 0.0, 'locator': 'Descripción de las Instalaciones; GREEN CAPITAL DEVELOPMENT XXXVIII S.L.U.; PE Arlo and budget paragraphs', 'method': 'count times proposed unit rating; not a replacement for reported project MW', 'reported_mw': 65.25, 'source_id': 'BOE-B-2026-23315'} unresolved
Armus {'calculated_mw': 35.0, 'locator': 'Características generales / Hibridación parque eólico Armus', 'method': '5 proposed units times7MW; arithmetic only', 'reported_mw': 35.0, 'source_id': 'BOE-B-2026-15548'} unresolved
Al-Ghat {'calculated_mw': 616.0, 'difference_mw': 16.0, 'locator': 'PDFpage4 design table; page3 introduction for Al Ghat / page4 introduction for Waad', 'method': 'NTS design count times7.7MW compared with NTS table MW; not installed/export capacity', 'reported_mw': 600.0, 'source_id': 'axia-alghat-nts-doc03'} unresolved
Dated proposal boundaries: reported MW, derating and mandatory removals
Satarrubla 2026-04-04 planned MW: None rating check MW: None required removals: None aggregation: unresolved
El Cerrate 2026-04-04 planned MW: None rating check MW: None required removals: None aggregation: unresolved
Abalar 2026-04-02 planned MW: None rating check MW: None required removals: ['ABA-03', 'ABA-04', 'ABA-06', 'ABA-09', 'ABA-10'] aggregation: unresolved
Satola 2026-04-04 planned MW: None rating check MW: None required removals: None aggregation: unresolved
Elawan Manzanares Híbrido 2026-04-01 planned MW: 36 rating check MW: 36 required removals: None aggregation: unresolved
None means unknown; original mixed-fleet designs are not revised layouts.
AEMO wind-only survey sites: unknown geometry and excluded capacity scopes
Ulladulla Offshore Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 2000, 'turbine_count': None}} unresolved
Goyder South Wind Farm 1B {'In Service': {'nameplate_mw_ac': 203.5, 'turbine_count': 37}} unresolved
Wombelano Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 23.4, 'turbine_count': 3}} unresolved
Forsayth Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 165, 'turbine_count': 30}} unresolved
Maroona Wind Farm {'In Service': {'nameplate_mw_ac': 6.9, 'turbine_count': 2}} unresolved
Dundonnell Wind Farm {'In Service': {'nameplate_mw_ac': 336.0, 'turbine_count': 80}} unresolved
Bendemeer Renewable Energy Hub - Wind {'Publicly Announced': {'nameplate_mw_ac': 379.8, 'turbine_count': 60}} unresolved
Specimen Hill Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 336, 'turbine_count': 56}} unresolved
Burrendong Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 434, 'turbine_count': 70}} unresolved
Uungula Wind Farm {'Committed': {'nameplate_mw_ac': 414, 'turbine_count': 69}} unresolved
Blue Mackerel North Off Shore Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 1819, 'turbine_count': None}} unresolved
Dugald River Wind Faarm {'Publicly Announced': {'nameplate_mw_ac': 144, 'turbine_count': None}} unresolved
Mount Emerald {'In Service': {'nameplate_mw_ac': 180.73, 'turbine_count': 53}} unresolved
Goyder South Wind Farm 1A {'In Service': {'nameplate_mw_ac': 209, 'turbine_count': 38}} unresolved
Barn Hill {'Publicly Announced': {'nameplate_mw_ac': 186, 'turbine_count': 62}} unresolved
Dinawan Energy Hub {'Publicly Announced': {'nameplate_mw_ac': 756.0, 'turbine_count': 105}} unresolved
Jackson North Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 613.8, 'turbine_count': 99}} unresolved
Lotus Creek Wind Farm {'Committed': {'nameplate_mw_ac': 285.2, 'turbine_count': 46}} unresolved
Hornsdale Wind Farm Stage 3 {'In Service': {'nameplate_mw_ac': 112, 'turbine_count': 35}} unresolved
Stony Creek Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 400, 'turbine_count': None}} unresolved
Bulgana Green Power Hub - Wind Farm {'In Service': {'nameplate_mw_ac': 200.75, 'turbine_count': 55}} unresolved
Kariboe Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 1020, 'turbine_count': 170}} unresolved
Gemfields Integrated Facility - Wind And Solar {'Publicly Announced': {'nameplate_mw_ac': 1200, 'turbine_count': None}} unresolved
Connors River Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 800, 'turbine_count': None}} unresolved
Dulacca Wind Farm {'In Service': {'nameplate_mw_ac': 172.86, 'turbine_count': 43}} unresolved
Southern Winds Offshore Wind {'Publicly Announced': {'nameplate_mw_ac': 1155, 'turbine_count': 77}} unresolved
Carmodys Hill Wind Farm {'Committed': {'nameplate_mw_ac': 256.2, 'turbine_count': 42}} unresolved
Bungaban Wind Farm {'Anticipated': {'nameplate_mw_ac': 1155, 'turbine_count': 165}} unresolved
Stockyard Hill Wind Farm {'In Service': {'nameplate_mw_ac': 527.56, 'turbine_count': 149}} unresolved
Cherry Tree Wind Farm {'In Service': {'nameplate_mw_ac': 57.6, 'turbine_count': 16}} unresolved
Conargo Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 129.6, 'turbine_count': 18}} unresolved
Mallee Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 547.2, 'turbine_count': 76}} unresolved
Bowmans Creek Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 346.64, 'turbine_count': 56}} unresolved
Forest Wind {'Publicly Announced': {'nameplate_mw_ac': 1200, 'turbine_count': None}} unresolved
Coppabella Hybrid Generator {'Anticipated': {'nameplate_mw_ac': 289.8, 'turbine_count': 69}} unresolved
Piambong Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 583.2, 'turbine_count': 81}} unresolved
Argoon Wind Farm (RES Group) - KCI {'Publicly Announced': {'nameplate_mw_ac': 763.2, 'turbine_count': 106}} unresolved
Cattle Hill Wind Farm {'In Service': {'nameplate_mw_ac': 144, 'turbine_count': 45}} unresolved
Valley of the Winds {'Anticipated': {'nameplate_mw_ac': 944, 'turbine_count': 118}} unresolved
Wallaby Creek Wind Farm {'Anticipated': {'nameplate_mw_ac': 216.6, 'turbine_count': 38}} unresolved
Bookham WF and BESS {'Publicly Announced': {'nameplate_mw_ac': 480, 'turbine_count': 60}} unresolved
Golden Plains Wind Farm East {'In Service': {'nameplate_mw_ac': 756.4, 'turbine_count': 122}} unresolved
Junction Rivers Wind And BESS {'Publicly Announced': {'nameplate_mw_ac': 595.2, 'turbine_count': 96}} unresolved
Mt Challenger Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 216, 'turbine_count': 30}} unresolved
Marmadua Wind Farm (KCI) {'Publicly Announced': {'nameplate_mw_ac': 950, 'turbine_count': None}} unresolved
Western Tables Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 1000, 'turbine_count': None}} unresolved
Mortlake South Wind Farm {'In Service': {'nameplate_mw_ac': 157.5, 'turbine_count': 35}} unresolved
Boort Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 1000, 'turbine_count': 125}} unresolved
Millmerran Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 252, 'turbine_count': 42}} unresolved
Meering West Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 1500, 'turbine_count': 200}} unresolved
Strathbogie Ranges Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 800, 'turbine_count': 100}} unresolved
Bellbay Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 190.4, 'turbine_count': 28}} unresolved
Kaban Wind Farm {'In Service': {'nameplate_mw_ac': 156.8, 'turbine_count': 28}} unresolved
Kerrs Creek Wind Farm {'Anticipated': {'nameplate_mw_ac': 396, 'turbine_count': 55}} unresolved
Mt Fox Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 291.4, 'turbine_count': 47}} unresolved
Koorakee Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 300, 'turbine_count': 50}} unresolved
Silverton Wind Farm {'In Service': {'nameplate_mw_ac': 198.94, 'turbine_count': 58}} unresolved
Euston Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 330, 'turbine_count': None}} unresolved
Ferguson Wind Farm {'In Service': {'nameplate_mw_ac': 12, 'turbine_count': 3}} unresolved
Ilford Green Energy Hub {'Publicly Announced': {'nameplate_mw_ac': 322, 'turbine_count': 46}} unresolved
Karma Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 966, 'turbine_count': None}} unresolved
Hellyer Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 155, 'turbine_count': 25}} unresolved
Skye Ridge Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 750.2, 'turbine_count': 121}} unresolved
Clarke Creek Wind Farm {'In Commissioning': {'nameplate_mw_ac': 450.0, 'turbine_count': 100}} unresolved
Kentbruck Green Power Hub {'Publicly Announced': {'nameplate_mw_ac': 676.8, 'turbine_count': 94}} unresolved
Elderbury Creek Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 122.4, 'turbine_count': 18}} unresolved
Ruby Hills North Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 248, 'turbine_count': 40}} unresolved
Burrenbring Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 360, 'turbine_count': 72}} unresolved
Middle Creek Renewable Energy Hub - Wind {'Publicly Announced': {'nameplate_mw_ac': 750, 'turbine_count': None}} unresolved
Magnetite Energy Hub {'Publicly Announced': {'nameplate_mw_ac': 504, 'turbine_count': 70}} unresolved
Coonooer Bridge Wind Farm {'In Service': {'nameplate_mw_ac': 19.8, 'turbine_count': 6}} unresolved
Jeremiah Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 288, 'turbine_count': 48}} unresolved
Timboon West Wind Farm {'In Service': {'nameplate_mw_ac': 7.2, 'turbine_count': 2}} unresolved
Salt Creek Wind Farm {'In Service': {'nameplate_mw_ac': 54, 'turbine_count': 15}} unresolved
Watta Wella Power Station {'Publicly Announced': {'nameplate_mw_ac': 306, 'turbine_count': 45}} unresolved
Mount Lambie Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 144, 'turbine_count': 20}} unresolved
Bald Hills Wind Farm {'In Service': {'nameplate_mw_ac': 106.6, 'turbine_count': 52}} unresolved
Liverpool Range Wind Farm {'Anticipated': {'nameplate_mw_ac': 1245.6, 'turbine_count': 173}} unresolved
Star of the South Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 2205, 'turbine_count': 147}} unresolved
Springlands Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 798.6, 'turbine_count': 121}} unresolved
Whaleback Ridge Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 288, 'turbine_count': 40}} unresolved
Warracknabeal Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 1576.8, 'turbine_count': 219}} unresolved
Thunderbolt Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 210, 'turbine_count': 28}} unresolved
Devlins Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 662.7, 'turbine_count': 94}} unresolved
Eastern Rise Offshore Wind {'Publicly Announced': {'nameplate_mw_ac': 1725, 'turbine_count': 115}} unresolved
Gawara Baya Wind And BESS {'Committed': {'nameplate_mw_ac': 408, 'turbine_count': 68}} unresolved
Pottinger Energy Park - Wind - KCI {'Publicly Announced': {'nameplate_mw_ac': 1300, 'turbine_count': 250}} unresolved
Wambo Wind Farm 1 {'Committed': {'nameplate_mw_ac': 248, 'turbine_count': None}, 'In Commissioning': {'nameplate_mw_ac': 252, 'turbine_count': None}} unresolved
Central Para Wind Farm (KCI) {'Publicly Announced': {'nameplate_mw_ac': 399, 'turbine_count': 57}} unresolved
Willogoleche Wind Farm {'In Service': {'nameplate_mw_ac': 122.56, 'turbine_count': 32}} unresolved
High Sea Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 1281, 'turbine_count': 61}} unresolved
Callide Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 421.6, 'turbine_count': 68}} unresolved
Boulder Creek Wind Farm {'Committed': {'nameplate_mw_ac': 221.16, 'turbine_count': 38}} unresolved
Koyuga Nanneella Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 234, 'turbine_count': 30}} unresolved
Great Eastern Offshore Wind - KCI {'Publicly Announced': {'nameplate_mw_ac': 2508, 'turbine_count': None}} unresolved
Yendon Wind Farm {'In Service': {'nameplate_mw_ac': 144.4, 'turbine_count': 38}} unresolved
Spinifex Offshore Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 1206, 'turbine_count': 67}} unresolved
Burroway Energy Hub {'Publicly Announced': {'nameplate_mw_ac': 241.8, 'turbine_count': 52}} unresolved
Bottle Tree Energy Park {'Publicly Announced': {'nameplate_mw_ac': 360, 'turbine_count': 50}} unresolved
Diapur Wind Farm {'In Service': {'nameplate_mw_ac': 8, 'turbine_count': 2}} unresolved
Nemaroo Bimbi Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 800, 'turbine_count': None}} unresolved
Eden Offshore Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 2000, 'turbine_count': None}} unresolved
Palmer Wind Farm {'Anticipated': {'nameplate_mw_ac': 274, 'turbine_count': 40}} unresolved
Coopers Gap Wind Farm {'In Service': {'nameplate_mw_ac': 452.89, 'turbine_count': 123}} unresolved
Goyder North Wind Farm {'Anticipated': {'nameplate_mw_ac': 645.6, 'turbine_count': 98}} unresolved
Spicers Creek Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 702, 'turbine_count': 117}} unresolved
Pikedale Wind Farm (KCI) {'Publicly Announced': {'nameplate_mw_ac': 1500, 'turbine_count': 250}} unresolved
Milpulling Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 432, 'turbine_count': 54}} unresolved
Gippsland Dawn Offshore Wind Project {'Publicly Announced': {'nameplate_mw_ac': 2100, 'turbine_count': 140}} unresolved
Tarong West Wind Farm (Ironleaf) {'Anticipated': {'nameplate_mw_ac': 436.5, 'turbine_count': 97}} unresolved
Winterbourne Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 731.6, 'turbine_count': 118}} unresolved
Bullawah Wind Farm – Stage 1 {'Publicly Announced': {'nameplate_mw_ac': 312, 'turbine_count': 52}} unresolved
Bogandilla Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 663, 'turbine_count': 85}} unresolved
Alberton Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 122.4, 'turbine_count': 34}} unresolved
Paling Yards Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 286.7, 'turbine_count': 47}} unresolved
Port Augusta Renewable Energy Park - Wind {'In Service': {'nameplate_mw_ac': 201, 'turbine_count': 50}} unresolved
Hawkesdale Wind Farm {'In Service': {'nameplate_mw_ac': 96.6, 'turbine_count': 23}} unresolved
Illawarra Offshore Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 2000, 'turbine_count': None}} unresolved
Bass Offshore Wind Energy Project {'Publicly Announced': {'nameplate_mw_ac': 500, 'turbine_count': None}} unresolved
Chepstowe Wind Farm - VIC {'In Service': {'nameplate_mw_ac': 6.15, 'turbine_count': 3}} unresolved
Willatook {'Publicly Announced': {'nameplate_mw_ac': 374.4, 'turbine_count': 52}} unresolved
North East Wind - KCI {'Publicly Announced': {'nameplate_mw_ac': 1288.8, 'turbine_count': 179}} unresolved
Theodore Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 1054.0, 'turbine_count': 170}} unresolved
Bendenine {'Publicly Announced': {'nameplate_mw_ac': 576, 'turbine_count': 80}} unresolved
Herries Range Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 897.6, 'turbine_count': 132}} unresolved
Collector {'In Service': {'nameplate_mw_ac': 226.8, 'turbine_count': 54}} unresolved
White Rock Wind Farm - Stage 1 {'In Service': {'nameplate_mw_ac': 175, 'turbine_count': 70}} unresolved
Golden Plains Wind Farm West {'In Commissioning': {'nameplate_mw_ac': 557, 'turbine_count': 93}} unresolved
Rye Park Wind Farm {'In Service': {'nameplate_mw_ac': 396, 'turbine_count': 66}} unresolved
Kennedy Energy Park {'In Service': {'nameplate_mw_ac': 43.2, 'turbine_count': 12}} unresolved
Bunkers Hill Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 499.2, 'turbine_count': 64}} unresolved
Nonowie Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 1008, 'turbine_count': 126}} unresolved
Nyaninyuk Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 302.1, 'turbine_count': 53}} unresolved
Moreton Hill Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 387.6, 'turbine_count': 57}} unresolved
Boomber Green Energy Hub {'Publicly Announced': {'nameplate_mw_ac': 1185.6, 'turbine_count': 152}} unresolved
Woolsthorpe Wind Farm {'Anticipated': {'nameplate_mw_ac': 72, 'turbine_count': 12}} unresolved
Harrami Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 799.2, 'turbine_count': 111}} unresolved
Yawong Wind Farm {'In Service': {'nameplate_mw_ac': 7.2, 'turbine_count': 2}} unresolved
Delburn Wind Farm {'Committed*': {'nameplate_mw_ac': 204.6, 'turbine_count': 33}} unresolved
Ryan Corner Wind Farm {'In Service': {'nameplate_mw_ac': 218.4, 'turbine_count': 52}} unresolved
Crudine Ridge Wind Farm {'In Service': {'nameplate_mw_ac': 141.71, 'turbine_count': 37}} unresolved
Tall Tree Wind Farm and BESS {'Publicly Announced': {'nameplate_mw_ac': 342, 'turbine_count': 60}} unresolved
Aquila Wind {'Publicly Announced': {'nameplate_mw_ac': 201.6, 'turbine_count': 28}} unresolved
Bashan 1 Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 460.2, 'turbine_count': 59}} unresolved
South Pacific Offshore Wind Project {'Publicly Announced': {'nameplate_mw_ac': 1601.25, 'turbine_count': 105}} unresolved
Lake Victoria Energy Park - KCI {'Publicly Announced': {'nameplate_mw_ac': 1087.5, 'turbine_count': 145}} unresolved
Cattle Creek Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 850.0, 'turbine_count': 125}} unresolved
Tchelery Wind Farm and BESS {'Publicly Announced': {'nameplate_mw_ac': 403.2, 'turbine_count': 56}} unresolved
Hexham {'Publicly Announced': {'nameplate_mw_ac': 624, 'turbine_count': 80}} unresolved
Granville Harbour Wind Farm {'In Service': {'nameplate_mw_ac': 111.6, 'turbine_count': 31}} unresolved
Goombi Renewable Energy Hub {'Publicly Announced': {'nameplate_mw_ac': 663.4, 'turbine_count': 107}} unresolved
Greater Southern Offshore Wind - KCI {'Publicly Announced': {'nameplate_mw_ac': 1500, 'turbine_count': None}} unresolved
Triabunna Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 23.4, 'turbine_count': 3}} unresolved
Gol Gol Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 499.66, 'turbine_count': 83}} unresolved
Hornsdale Wind Farm Stage 2 {'In Service': {'nameplate_mw_ac': 102.4, 'turbine_count': 32}} unresolved
Hornsdale Wind Farm Stage 1 {'In Service': {'nameplate_mw_ac': 102.4, 'turbine_count': 32}} unresolved
George Town Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 232, 'turbine_count': None}} unresolved
Novocastrian Offshore Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 2000, 'turbine_count': None}} unresolved
Cellars Hill Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 400, 'turbine_count': 50}} unresolved
Ben Bullen Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 460.8, 'turbine_count': 64}} unresolved
Whyte Yarcowie {'Publicly Announced': {'nameplate_mw_ac': 288.6, 'turbine_count': 37}} unresolved
Inverleigh Wind Farm {'Anticipated': {'nameplate_mw_ac': 91.5, 'turbine_count': 15}} unresolved
St Patricks Plains Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 291.4, 'turbine_count': 47}} unresolved
Hunter Central Coast Offshore Energy (Wind) {'Publicly Announced': {'nameplate_mw_ac': 1400, 'turbine_count': None}} unresolved
Robbins Island Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 928.8, 'turbine_count': 129}} unresolved
Normanville Energy Park {'Publicly Announced': {'nameplate_mw_ac': 122.4, 'turbine_count': 17}} unresolved
Hollow Tree Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 421.2, 'turbine_count': 54}} unresolved
Banana Range Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 296.4, 'turbine_count': 38}} unresolved
Elaine Wind Farm {'In Service': {'nameplate_mw_ac': 83.6, 'turbine_count': 22}} unresolved
Guildford Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 525.6, 'turbine_count': 73}} unresolved
Coleraine Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 1000, 'turbine_count': None}} unresolved
Wimmera Plains Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 312, 'turbine_count': 52}} unresolved
Dawson Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 560, 'turbine_count': None}} unresolved
Mount Hopeful Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 370, 'turbine_count': 50}} unresolved
Western Plains Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 50.4, 'turbine_count': 12}} unresolved
Hills of Gold Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 420, 'turbine_count': 70}} unresolved
Darlington Wind Farm - GPG {'Publicly Announced': {'nameplate_mw_ac': 309.6, 'turbine_count': 43}} unresolved
Collinsville Green Energy Hub {'Publicly Announced': {'nameplate_mw_ac': 2839.2, 'turbine_count': 364}} unresolved
Bullawah Wind Farm Stage 2 {'Publicly Announced': {'nameplate_mw_ac': 276, 'turbine_count': 46}} unresolved
Orsted Gippsland 01 Windfarm {'Publicly Announced': {'nameplate_mw_ac': 2820.48, 'turbine_count': 192}} unresolved
Upper Hunter Energy Park - Wind {'Anticipated': {'nameplate_mw_ac': 75.6, 'turbine_count': 18}} unresolved
Port Latta Wind Farm {'Anticipated': {'nameplate_mw_ac': 21, 'turbine_count': 5}} unresolved
White Rock Wind Farm - Stage 2 {'Publicly Announced': {'nameplate_mw_ac': 211.5, 'turbine_count': 47}} unresolved
Yanco Delta Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 1497.6, 'turbine_count': 208}} unresolved
Tara Wind Farm - KCI {'Publicly Announced': {'nameplate_mw_ac': 1800, 'turbine_count': None}} unresolved
Northern Tablelands Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 504, 'turbine_count': 63}} unresolved
Kings Plain Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 399.61, 'turbine_count': 89}} unresolved
Conroys Gap WF - KCI {'Publicly Announced': {'nameplate_mw_ac': 30, 'turbine_count': 15}} unresolved
Rifle Butts Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 40, 'turbine_count': None}} unresolved
The Plains {'Publicly Announced': {'nameplate_mw_ac': 1224, 'turbine_count': 180}} unresolved
Hughes Gap WF - KCI {'Publicly Announced': {'nameplate_mw_ac': 300, 'turbine_count': None}} unresolved
Berrybank Wind Farm {'In Service': {'nameplate_mw_ac': 289.8, 'turbine_count': 69}} unresolved
Coonerang Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 264, 'turbine_count': 33}} unresolved
Captains Mountain Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 217, 'turbine_count': 35}} unresolved
Flyers Creek Wind Farm {'In Service': {'nameplate_mw_ac': 145.54, 'turbine_count': 38}} unresolved
Derwent Valley Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 150, 'turbine_count': None}} unresolved
Mount Fyans Wind Farm {'Publicly Announced': {'nameplate_mw_ac': 550.8, 'turbine_count': 81}} unresolved
Moah Creek Wind Farm {'Anticipated': {'nameplate_mw_ac': 360, 'turbine_count': 60}} unresolved
EIA evidence: project counts, not capacity totals {'projects': 1182, 'unresolved_scope': 1182, 'unknown_installed_mw': 1182}
Published turbine power ratings require their measurement conditions
model ... rotor_diameter_m
23 SD6 ... 5.6
25 DS3000 ... NaN
123 Skystream 3.7 ... NaN
151 SkyWind NG ... NaN
171 KW30 ... NaN
268 Excel 15 ... 9.6
395 KW20 ... NaN
448 Kestrel e400nb ... NaN
545 EOX S-16 ... NaN
[9 rows x 4 columns]
Goldwind complete named columns: geometry, power conditions and offered hubs
model rated_power_kw rotor_diameter_m swept_area_m2 rated_power_conditions hub_height_options_json
GWH182-6.0MW 6000.0 183.5 26446.0 OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
GWH182-7.2MW 7200.0 183.5 NaN OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
GW 87/1500 1500.0 87.0 NaN OEM nominal model rating; density/mode unspecified, not independently validated performance None
GW 82/1500 1500.0 82.0 NaN OEM nominal model rating; density/mode unspecified, not independently validated performance None
GWH175-7.8MW 7800.0 175.0 24053.0 OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[105]}
GWH170-7.2MW 7200.0 170.0 22698.0 OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[105]}
GW155-4.5MW 4500.0 155.0 18869.0 OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[95,110,140]}
GWH182-7.5MW 7500.0 183.5 NaN OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
GW 70/1500 1500.0 70.0 NaN OEM nominal model rating; density/mode unspecified, not independently validated performance None
GWH182-5.3MW 5300.0 183.5 NaN OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
GW165-5.6MW 5600.0 165.8 21590.0 OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
GW165-6.0MW 6000.0 165.8 21590.0 OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
GW136-4.2MW 4200.0 136.0 14527.0 OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[100]}
GW 77/1500 1500.0 77.0 NaN OEM nominal model rating; density/mode unspecified, not independently validated performance None
GWH204-10.5MW 10500.0 204.0 32685.0 OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[120]}
GWH182-6.2MW 6200.0 183.5 NaN OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
GW136-4.8MW 4800.0 136.0 14527.0 OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[100]}
GW 121/2500 2500.0 121.0 NaN OEM nominal model rating; density/mode unspecified; not independently validated performance None
GW 100/2500 2500.0 100.0 NaN OEM nominal model rating; density/mode unspecified; not independently validated performance None
GW165-5.2MW 5200.0 165.8 21590.0 OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
GW 109/2500 2500.0 109.0 NaN OEM nominal model rating; density/mode unspecified; not independently validated performance None
GWH182-8.0MW 8000.0 183.5 26446.0 OEM table rated power; air density and operating-mode test conditions unspecified. Not a comparable power curve. {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
Hub options do not create model variants; no common-condition power curves inferred.
Dated OEM product updates: modes and approval timing, not installed variants
Nordex N175/6.X 2026-04-22 [{'conditions': 'New nominal mode announced for N175/6.X; site-specific conditions and curve/density not published here', 'normalization': 'MW x 1000 = kW', 'original_unit': 'MW', 'original_value': 7.3, 'rated_power_kw': 7300}]
[{'deliveries': 'possible second half of 2026; not evidence of delivery', 'hub_height_m': 162.5, 'region': 'Germany', 'status': 'under development as reported 2026-04-22', 'technology': 'concrete-steel hybrid', 'type_approval': 'scheduled Q2 2026; completion not established by this source'}, {'certificate_id': None, 'certifier': 'TUV SUED', 'guidelines': 'DIBt', 'hub_height_m': 179, 'status': 'manufacturer reports type approval received', 'supplier': 'Max Boegl', 'technology': 'hybrid concrete', 'type_approval_date': '2026-04-21'}] Dated OEM specification announcement, not independently validated performance. Tower choices remain nested; unnamed tower configurations are not separate exact models. No Cartesian mode/tower variants, no curve or unchanged sound-power scalar inferred.
OEM historical observations: not current configuration or fleet retirement
AW82/1500 2025-06-12 Dated production status; any prototype facts apply only to identified prototype, not all installed turbines
{'production_status_observation': 'discontinued', 'status_as_of': '2025-06-12', 'status_scope': 'Article explicitly says all former AW turbines; not operating-fleet status or service availability'}
N117/3000 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'article_model_label': 'N117/3000', 'generation': 'Delta', 'hub_access': 'Weather-protected direct access', 'nacelle': 'Redesigned for more space and maintenance access', 'platform_introduced_year': 2013}
N90/2500 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'article_model_label': 'N90/2500', 'design': 'modular', 'generation': 'Gamma', 'hub_access': 'rear entry', 'internal_gantry_component_limit_kg': 1000, 'service_boundary': 'Weather-protected servicing without opening nacelle roof; not total nacelle lifting capacity'}
N80/2500 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'date_comparison': 'History table Year2000 retained separately; launch and table year are not treated as identical milestones', 'generation': 'Alpha', 'launch_year': 1999, 'power_control': 'pitch'}
AW125/3000 2025-06-12 Dated production status; any prototype facts apply only to identified prototype, not all installed turbines
{'production_status_observation': 'discontinued', 'status_as_of': '2025-06-12', 'status_scope': 'Article explicitly says all former AW turbines; not operating-fleet status or service availability'}
N149/4.X 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'launch_year': 2017, 'option_scope': 'At launch; no fixed selected operating mode or Cartesian variants', 'original_model_label': 'N149/4.5', 'site_specific_power_options_mw': {'maximum': 4.5, 'minimum': 4}, 'subsequent_model_label': 'N149/4.X'}
N131/3000 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'article_model_label': 'N131/3000', 'generation': 'Delta', 'hub_access': 'Weather-protected direct access', 'nacelle': 'Redesigned for more space and maintenance access', 'platform_introduced_year': 2013}
N100 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'article_model_label': 'N100/2500', 'design': 'modular', 'generation': 'Gamma', 'hub_access': 'rear entry', 'internal_gantry_component_limit_kg': 1000, 'service_boundary': 'Weather-protected servicing without opening nacelle roof; not total nacelle lifting capacity'}
N52 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'article_model_label': 'N52/1000', 'braking': 'blade tips released and twisted for overspeed protection', 'control': 'aerodynamic stall', 'drivetrain': 'geared generator directly connected to grid', 'power_converter': False, 'speed_control': 'fixed speed'}
N163/6.X 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'introduced_year': 2021, 'mode_scope': 'No exact upper bound or selected mode inferred', 'nominal_output_mw': {'maximum': None, 'minimum': 6, 'upper_bound_text': 'nearly7MW'}}
AW77/1500 2025-06-12 Dated production status; any prototype facts apply only to identified prototype, not all installed turbines
{'production_status_observation': 'discontinued', 'status_as_of': '2025-06-12', 'status_scope': 'Article explicitly says all former AW turbines; not operating-fleet status or service availability'}
S46 2025-06-12 750kW variant mentioned in retrospective article; not every S46 configuration
{'observed_power_kw': 750, 'power_control': 'pitch', 'version_scope': '750kW units only;600/750kW history-table range remains unresolved'}
AW116/3000 2025-06-12 Dated production status; any prototype facts apply only to identified prototype, not all installed turbines
{'production_status_observation': 'discontinued', 'status_as_of': '2025-06-12', 'status_scope': 'Article explicitly says all former AW turbines; not operating-fleet status or service availability'}
N52 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'article_model_label': 'N52/800', 'braking': 'blade tips released and twisted for overspeed protection', 'control': 'aerodynamic stall', 'drivetrain': 'geared generator directly connected to grid', 'power_converter': False, 'speed_control': 'fixed speed'}
S70 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'brand': 'Südwind', 'licensed_production': True, 'observed_power_mw': 1.5, 'power_control': 'pitch'}
N155 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'blade_girders_scope': 'Explicit exception to later carbon-fibre-girder adoption; alternative material unspecified', 'production_status_observation': 'discontinued', 'status_as_of': '2025-06-12'}
AW109/3000 2025-06-12 Dated production status; any prototype facts apply only to identified prototype, not all installed turbines
{'production_status_observation': 'discontinued', 'status_as_of': '2025-06-12', 'status_scope': 'Article explicitly says all former AW turbines; not operating-fleet status or service availability'}
AW140/3000 2025-06-12 Dated production status; any prototype facts apply only to identified prototype, not all installed turbines
{'production_status_observation': 'discontinued', 'status_as_of': '2025-06-12', 'status_scope': 'Article explicitly says all former AW turbines; not operating-fleet status or service availability'}
S77 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'brand': 'Südwind', 'licensed_production': True, 'observed_power_mw': 1.5, 'power_control': 'pitch'}
N60 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'article_model_label': 'N60/1300', 'braking': 'blade tips released and twisted for overspeed protection', 'control': 'aerodynamic stall', 'drivetrain': 'geared generator directly connected to grid', 'power_converter': False, 'speed_control': 'fixed speed'}
AW132/3000 2025-06-12 Dated production status; any prototype facts apply only to identified prototype, not all installed turbines
{'production_status_observation': 'discontinued', 'status_as_of': '2025-06-12', 'status_scope': 'Article explicitly says all former AW turbines; not operating-fleet status or service availability'}
N43 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'article_model_label': 'N43/600', 'braking': 'blade tips released and twisted for overspeed protection', 'control': 'aerodynamic stall', 'drivetrain': 'geared generator directly connected to grid', 'manufacturing_observation': {'basis': 'OEM reports co-production', 'country': 'China', 'period': 'late1990s'}, 'power_converter': False, 'speed_control': 'fixed speed'}
AW70/1300 2025-06-12 Dated production status; any prototype facts apply only to identified prototype, not all installed turbines
{'production_status_observation': 'discontinued', 'prototype': {'design_outcome': 'prototype concept abandoned; later2002pre-series not assigned to this exact configuration', 'pitch': 'hydraulic motors and hydraulic accumulators'}, 'status_as_of': '2025-06-12', 'status_scope': 'Article explicitly says all former AW turbines; not operating-fleet status or service availability'}
N62 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'article_model_label': 'N62/1300', 'braking': 'blade tips released and twisted for overspeed protection', 'control': 'aerodynamic stall', 'drivetrain': 'geared generator directly connected to grid', 'power_converter': False, 'speed_control': 'fixed speed'}
N163/5.X 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'mode_scope': 'OEM retrospective settings upper bound; no selected mode or environmental conditions', 'power_settings_upper_mw': 5.7, 'prior_table_observation': 'History table reports only5MW range; dated article supplies an upper setting, not a selected rated-power scalar'}
AW100/3000 2025-06-12 Dated production status; any prototype facts apply only to identified prototype, not all installed turbines
{'production_status_observation': 'discontinued', 'status_as_of': '2025-06-12', 'status_scope': 'Article explicitly says all former AW turbines; not operating-fleet status or service availability'}
N175/6.X 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'blade_construction': 'single piece', 'blade_length_m': 85.7, 'conflicting_hub_range': {'decision': 'Retain both dated/range observations; revision and rounding unresolved; no scalar overwrite', 'other_maximum_m': 199, 'other_source_id': 'nordex_history_2025path_20261105'}, 'first_installations_Germany_year': 2024, 'hub_height_range_m': {'maximum': 200, 'minimum': 112}, 'introduced_year': 2022, 'reported_reached_hub_height_m': 179, 'reported_reached_hub_height_year': 2025}
AW70/1500 2025-06-12 Dated production status; any prototype facts apply only to identified prototype, not all installed turbines
{'production_status_observation': 'discontinued', 'status_as_of': '2025-06-12', 'status_scope': 'Article explicitly says all former AW turbines; not operating-fleet status or service availability'}
N100 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'article_model_label': 'N100/3300', 'generation': 'Delta', 'hub_access': 'Weather-protected direct access', 'nacelle': 'Redesigned for more space and maintenance access', 'platform_introduced_year': 2013}
AW60/1300 2025-06-12 Dated production status; any prototype facts apply only to identified prototype, not all installed turbines
{'production_status_observation': 'discontinued', 'prototype': {'blade_length_m': 29, 'generator': 'doubly-fed induction', 'installed_month': '2000-08', 'output_voltage_class': 'medium voltage; exact kV unknown', 'pitch': 'three hydraulic cylinders', 'speed_control': 'variable speed'}, 'status_as_of': '2025-06-12', 'status_scope': 'Article explicitly says all former AW turbines; not operating-fleet status or service availability'}
N117 2025-06-12 Historical model design; installed revision, options and current eligibility unknown
{'article_model_label': 'N117/2400', 'blade_girders': 'carbon fibre', 'design': 'modular', 'generation': 'Gamma', 'hub_access': 'rear entry', 'internal_gantry_component_limit_kg': 1000, 'introduced_year': 2011, 'service_boundary': 'Weather-protected servicing without opening nacelle roof; not total nacelle lifting capacity'}
FGW observation counts by reference site and withdrawn status:
{('EEG2014-old', False): 204, ('EEG2017-new', False): 170, ('EEG2017-new', True): 9}
Reference observations with unknown rotor diameter: 146
Dated reference-yield corrections, not commissioning: 3
Reference yields retain five-year kWh, hub/power settings and source notes.
Density, operating mode and gross/net boundary are unknown; no CF or performance comparison.
Certification registry observations by stated status: {'expired': 4, 'unspecified': 20}
Unspecified status does not establish current validity; listed date is not commissioning.
EIA 2025 dated unit evidence: farm status/capacity exclusions remain unchanged
Storm Lake 1 54793 2025 ['OP', 'OP', 'OP'] unknown unresolved
Four Corners Windfarm LLC 56969 2025 ['OP'] unknown unresolved
Windcurrent Farms LLC 56205 2025 ['OP'] unknown unresolved
Eolos Wind Energy Research Field Station 57880 2025 ['OP'] unknown unresolved
Blue Summit III Wind 62566 2025 ['OP'] unknown unresolved
WED NK Green 59295 2025 ['OP'] unknown unresolved
Goldthwaite Wind Energy Facility 58321 2025 ['OP'] unknown unresolved
Roosevelt County 58771 2025 ['OP'] unknown unresolved
Palouse 57530 2025 ['OP'] unknown unresolved
Prairie Rose Wind Farm 57644 2025 ['OP'] unknown unresolved
Elkhorn Valley Wind Farm 56623 2025 ['OP'] unknown unresolved
Bluestem 60256 2025 ['OP'] unknown unresolved
Fey Windfarm LLC 56204 2025 ['OP'] unknown unresolved
Antrim Wind 59953 2025 ['OP'] unknown unresolved
Bingham Wind 57531 2025 ['OP'] unknown unresolved
Spruce Mountain WInd 58026 2025 ['OP'] unknown unresolved
Whirlpool Corporation - Ottawa Wind Farm 61004 2025 ['OP'] unknown unresolved
Meridian Wind Park 65328 2025 ['OP'] unknown unresolved
Bishop Hill III 61787 2025 ['OP'] unknown unresolved
G McNeilus Wind Farm Dodge Center 56054 2025 ['OP', 'OP', 'OP'] unknown unresolved
TPW Petersburg 57755 2025 ['OP'] unknown unresolved
Golden Valley Wind Park LLC 56435 2025 ['OP'] unknown unresolved
TG Windfarm LLC 56199 2025 ['OP'] unknown unresolved
NBC Field's Point Wind Farm 59692 2025 ['OP'] unknown unresolved
NWP Indian Mesa Wind Farm 55747 2025 ['OP'] unknown unresolved
Trinity Hills 57520 2025 ['OP'] unknown unresolved
Notus Wind 1 57414 2025 ['OP'] unknown unresolved
Diablo Winds LLC 56271 2025 ['OP'] unknown unresolved
Foundation Scheid Vineyards 61067 2025 ['OP'] unknown unresolved
Hatchet Ridge Wind Project 56654 2025 ['OP'] unknown unresolved
Meadow Creek Project Company 58106 2025 ['OP'] unknown unresolved
Pioneer Prairie Wind Farm 56797 2025 ['OP'] unknown unresolved
Star Point Wind Project LLC 57096 2025 ['OP'] unknown unresolved
Cooper Farms VW Project 57570 2025 ['OP'] unknown unresolved
Rock Falls Wind Farm LLC 61261 2025 ['OP'] unknown unresolved
Elm Creek Wind LLC 56793 2025 ['OP'] unknown unresolved
Chamberlain Wind Project 7974 2025 ['RE', 'RE'] unknown unresolved
Bison 2 Wind Energy Center 57800 2025 ['OP'] unknown unresolved
Plymouth Wind 64688 2025 ['OP'] unknown unresolved
Quilt Block Wind Farm LLC 57116 2025 ['OP'] unknown unresolved
Optimum Wind 3 LLC 59227 2025 ['OP'] unknown unresolved
Mesteno 62258 2025 ['OP'] unknown unresolved
Ida Grove II 62795 2025 ['OP'] unknown unresolved
Dempsey Ridge Wind Farm 56665 2025 ['CN'] unknown unresolved
Dempsey Ridge Wind Farm 56665 2025 ['OP'] unknown unresolved
Upland Prairie 61564 2025 ['OP'] unknown unresolved
Ocotillo Express LLC 57514 2025 ['OP'] unknown unresolved
Ford County Wind Farm LLC 65350 2025 ['OP'] unknown unresolved
El Cabo Wind 58098 2025 ['OP'] unknown unresolved
Palo Alto Wind Farm 63053 2025 ['OP', 'OP'] unknown unresolved
Minco Wind II LLC 57956 2025 ['OP'] unknown unresolved
Granite Reliable Power 58004 2025 ['OP'] unknown unresolved
Boswell Wind 65403 2025 ['OP'] unknown unresolved
Fenner Wind 55790 2025 ['OP'] unknown unresolved
Ashtabula Wind Energy Center 57032 2025 ['OP'] unknown unresolved
Soliloquoy Ridge LLC 55570 2025 ['OP'] unknown unresolved
Bennett Creek Windfarm LLC - Mountain Home 56637 2025 ['OP'] unknown unresolved
Pioneer Hutt Wind Energy 66531 2025 ['OP'] unknown unresolved
Altech III 50485 2025 ['RE', 'RE'] unknown unresolved
San Gorgonio Farms Wind Farm 50281 2025 ['OP'] unknown unresolved
Blue Creek Wind Project 57449 2025 ['OP'] unknown unresolved
WCROC Wind Farm 57823 2025 ['OP'] unknown unresolved
Juniper Canyon I Wind Project 57320 2025 ['OP'] unknown unresolved
Pillar Mountain Wind Project Microgrid 57187 2025 ['OP', 'OP'] unknown unresolved
UL Advanced Wind Turbine Test Facility 61589 2025 ['OP', 'OP'] unknown unresolved
White Oak Energy LLC 57342 2025 ['OP'] unknown unresolved
Hilltop Power 61788 2025 ['OP'] unknown unresolved
Oklahoma Wind Energy Center 56094 2025 ['OP', 'OP'] unknown unresolved
Twin Buttes Wind Project 56460 2025 ['OP'] unknown unresolved
Skookumchuck Wind Facility 63205 2025 ['OP'] unknown unresolved
Golden West Power Partners LLC 59974 2025 ['OP'] unknown unresolved
Smoky Hills Wind Project Phase II 56985 2025 ['OP'] unknown unresolved
Seven Mile Hill 56843 2025 ['OP', 'OP'] unknown unresolved
Gratiot County Wind LLC 58677 2025 ['OP'] unknown unresolved
Javelina Wind Energy LLC 60104 2025 ['OP'] unknown unresolved
Danielson Wind Farms LLC 57396 2025 ['OP'] unknown unresolved
Crescent Ridge 56297 2025 ['OP'] unknown unresolved
Sterling I Wind Farm 60991 2025 ['OP'] unknown unresolved
FPL Energy Crystal Lake Wind LLC 56923 2025 ['OP'] unknown unresolved
Roseman 62130 2025 ['OP'] unknown unresolved
Filet Wind (5) LLC 56561 2025 ['OP'] unknown unresolved
Santa Rita Wind Energy 60987 2025 ['OP'] unknown unresolved
Venus Wind 3 LLC 59230 2025 ['OP'] unknown unresolved
Paulding Wind Farm III 60470 2025 ['OP'] unknown unresolved
Green River Wind Farm 60471 2025 ['OP'] unknown unresolved
Oak Glen Wind Farm 57432 2025 ['OP'] unknown unresolved
Creston Ridge II LLC 61668 2025 ['OP', 'OP', 'OP'] unknown unresolved
Foundation California Training Facility 61442 2025 ['OP'] unknown unresolved
Future Generation Wind 59622 2025 ['OP'] unknown unresolved
Hawi Wind Farm 56447 2025 ['OP'] unknown unresolved
Lorenzo Wind 59244 2025 ['OP'] unknown unresolved
FPL Energy Story Wind LLC 56924 2025 ['OP'] unknown unresolved
Wolf Wind Enterprises LLC 56589 2025 ['OP'] unknown unresolved
Woodward Mountain I 55796 2025 ['OP'] unknown unresolved
Lakefield Wind Project LLC 57374 2025 ['OP'] unknown unresolved
Southern Hills Wind Farm 63640 2025 ['OP'] unknown unresolved
Windthorst-2 59238 2025 ['OP'] unknown unresolved
Contrail Wind Farm 63639 2025 ['OP'] unknown unresolved
Yahoo Creek 57126 2025 ['OP'] unknown unresolved
Grand Ridge Wind Energy Center 56941 2025 ['OP', 'OP', 'OP', 'OP'] unknown unresolved
Stetson Wind II 56991 2025 ['OP'] unknown unresolved
Pegasus Wind 61916 2025 ['OP', 'OP'] unknown unresolved
Edom Hills Project 1 LLC 50553 2025 ['RE'] unknown unresolved
Edom Hills Project 1 LLC 50553 2025 ['OP'] unknown unresolved
Westridge Windfarm LLC 56203 2025 ['OP'] unknown unresolved
Coyote Wind LLC 63655 2025 ['OP'] unknown unresolved
FPL Energy Illinois Wind LLC Hybrid 57325 2025 ['OP'] unknown unresolved
Sawtooth Wind Project 57749 2025 ['OP'] unknown unresolved
LafargeHolcim - Paulding Wind Project 62752 2025 ['OP', 'OP', 'OP'] unknown unresolved
Sendero 59654 2025 ['OP'] unknown unresolved
Victory Garden Phase IV LLC 52160 2025 ['RE'] unknown unresolved
Ralls Wind Farm 57474 2025 ['OP'] unknown unresolved
Mainline Windfarm 57429 2025 ['OP'] unknown unresolved
Post Wind Farm LP 56457 2025 ['OP'] unknown unresolved
Meyersdale Windpower LLC 56052 2025 ['OP'] unknown unresolved
Carroll Area Wind Farm 59071 2025 ['OP'] unknown unresolved
Langford Wind Power 57153 2025 ['OP'] unknown unresolved
Noble Ridge LLC 55782 2025 ['RE'] unknown unresolved
Anacacho Wind Farm LLC 58000 2025 ['OP'] unknown unresolved
Pheasant Run Wind LLC 58580 2025 ['OP'] unknown unresolved
Intrepid 56251 2025 ['OP', 'OP'] unknown unresolved
Leaning Juniper Wind Power II 57333 2025 ['OP'] unknown unresolved
South Chestnut LLC 56796 2025 ['OP'] unknown unresolved
Shane's Wind Machine 56577 2025 ['OP'] unknown unresolved
Sunflower Wind Project 60088 2025 ['OP'] unknown unresolved
Cotton Plains Wind Farm 60210 2025 ['OP'] unknown unresolved
Cedar Ridge 56347 2025 ['OP'] unknown unresolved
Niyol Wind, LLC 65059 2025 ['OP'] unknown unresolved
Anchor Wind LLC 58044 2025 ['RE'] unknown unresolved
Ribeye Wind (11) LLC 56835 2025 ['OP'] unknown unresolved
Coram Energy LLC (ECT) 54298 2025 ['RE'] unknown unresolved
Coram Energy LLC (ECT) 54298 2025 ['OP'] unknown unresolved
St. Olaf Wind Turbine 58995 2025 ['OP'] unknown unresolved
Sagebrush Power Partners 56858 2025 ['OP'] unknown unresolved
Marengo Wind Plant 56466 2025 ['OP', 'OP'] unknown unresolved
FPL Energy Crystal Lake Wind II LLC 56925 2025 ['OP'] unknown unresolved
Glass Sands Wind Facility 64750 2025 ['OP'] unknown unresolved
New Frontier Wind 59903 2025 ['OP'] unknown unresolved
Combine Hills I 56195 2025 ['OP'] unknown unresolved
Taconite Ridge 1 Wind Energy Center 56630 2025 ['OP'] unknown unresolved
San Roman Wind I LLC 59712 2025 ['OP'] unknown unresolved
High Lonesome Mesa LLC 56945 2025 ['OP'] unknown unresolved
Meadow Lake Wind Farm V LLC 57628 2025 ['OP'] unknown unresolved
Green Pastures Wind I 59732 2025 ['OP'] unknown unresolved
Big Sky Wind LLC 57135 2025 ['OP'] unknown unresolved
Hopkins Ridge Wind 56255 2025 ['OP', 'OP'] unknown unresolved
Spinning Spur Wind II 58774 2025 ['OP'] unknown unresolved
B&K Energy Systems LLC 56210 2025 ['OP'] unknown unresolved
25 Mile Creek 65511 2025 ['OP'] unknown unresolved
Flat Top Wind I 61212 2025 ['OP'] unknown unresolved
Michigan Wind 2 56659 2025 ['OP'] unknown unresolved
Scurry County Wind LP 56506 2025 ['OP'] unknown unresolved
Ninnescah Wind Energy LLC 60620 2025 ['OP'] unknown unresolved
High Trail Wind Farm LLC 56338 2025 ['OP'] unknown unresolved
Brady Wind Energy Center 60355 2025 ['OP'] unknown unresolved
Beech Ridge Energy LLC 57151 2025 ['OP'] unknown unresolved
Minco Wind I LLC 57590 2025 ['OP'] unknown unresolved
Harvest 2 57888 2025 ['OP'] unknown unresolved
Thunder Spirit Wind LLC 58965 2025 ['OP', 'OP'] unknown unresolved
Elbow Creek Wind Project LLC 56783 2025 ['OP'] unknown unresolved
Perrin Ranch Wind LLC 58155 2025 ['OP'] unknown unresolved
Meadow Lake Wind Farm VI LLC 61756 2025 ['OP'] unknown unresolved
Ashtabula Wind II LLC 57121 2025 ['OP'] unknown unresolved
O'Brien Wind 60326 2025 ['CN', 'CN', 'CN'] unknown unresolved
O'Brien Wind 60326 2025 ['OP', 'OP', 'OP'] unknown unresolved
Happy Jack Windpower Project 56960 2025 ['OP'] unknown unresolved
Stephens Ranch Wind Energy LLC 57983 2025 ['OP', 'OP'] unknown unresolved
Scurry County Wind II 56775 2025 ['OP'] unknown unresolved
Cedar Creek Wind 56371 2025 ['OP', 'OP'] unknown unresolved
Bearkat 59972 2025 ['CN'] unknown unresolved
Bearkat 59972 2025 ['OP'] unknown unresolved
Shiloh I Wind Project 56362 2025 ['OP'] unknown unresolved
High Prairie Wind Farm 62563 2025 ['OP'] unknown unresolved
Drift Sand Wind Project LLC 59065 2025 ['OP'] unknown unresolved
Persimmon Creek Wind Farm 1 LLC 61876 2025 ['OP'] unknown unresolved
Linden Wind Energy Project 57635 2025 ['OP'] unknown unresolved
Milner Dam Wind Park LLC 56437 2025 ['OP'] unknown unresolved
Pine Tree Wind Power Project 56433 2025 ['OP'] unknown unresolved
Hardin Hilltop Wind LLC 56860 2025 ['OP'] unknown unresolved
Anderson Wind II 58940 2025 ['OP'] unknown unresolved
CED Centerville Wind 64178 2025 ['OP'] unknown unresolved
Prairie Star Wind Farm 56494 2025 ['OP'] unknown unresolved
Echo Wind Park 58121 2025 ['OP', 'OP', 'OP'] unknown unresolved
Dry Lake Wind LLC 57098 2025 ['OP'] unknown unresolved
Seiling Wind I 59311 2025 ['OP'] unknown unresolved
Fort Hays State University Wind Farm 61540 2025 ['OP', 'OP'] unknown unresolved
Nobles Wind Project 57047 2025 ['OP'] unknown unresolved
Llano Estacado Wind Ranch 55579 2025 ['OP'] unknown unresolved
LE Wind Turbine 1 57613 2025 ['OP'] unknown unresolved
Sholes Wind Energy Center 61889 2025 ['OP'] unknown unresolved
Emmons-Logan Wind LLC 62380 2025 ['OP'] unknown unresolved
Eurus Combine Hills Turbine Ranch 2 57137 2025 ['OP'] unknown unresolved
Stoney Corners Wind Farm 57131 2025 ['OP'] unknown unresolved
Pakini Nui Wind Farm 56378 2025 ['OP'] unknown unresolved
Copenhagen Wind Farm 58979 2025 ['OP'] unknown unresolved
Wolverine Creek 56301 2025 ['OP'] unknown unresolved
Panther Creek Wind Farm Three 56979 2025 ['OP'] unknown unresolved
Green Acres Breeze LLC 56590 2025 ['OP'] unknown unresolved
Caddo Wind 64047 2025 ['OP'] unknown unresolved
Wind GEM 60541 2025 ['OP'] unknown unresolved
Blue Sky Green Field Wind Project 56391 2025 ['OP'] unknown unresolved
Mesalands Comm College Wind Turbine 57106 2025 ['OP'] unknown unresolved
Horseshoe Bend Wind Park 56591 2025 ['OP'] unknown unresolved
K-Brink Windfarm LLC 56206 2025 ['OP'] unknown unresolved
Bison 3 Wind Energy Center 57801 2025 ['OP'] unknown unresolved
Cimarron Windpower II 57663 2025 ['OP'] unknown unresolved
Langdon Wind Energy Center 57033 2025 ['OP'] unknown unresolved
Eastridge Wind Project 56543 2025 ['OP'] unknown unresolved
Inadale Wind Farm LLC Hybrid 56984 2025 ['OP'] unknown unresolved
Glaciers Edge Wind Project 62035 2025 ['OP'] unknown unresolved
Salmon Falls Wind Park 56441 2025 ['OP'] unknown unresolved
Musselshell Wind Project 57963 2025 ['OP'] unknown unresolved
EcoGrove Wind LLC 56805 2025 ['OP'] unknown unresolved
Kingman Wind 60639 2025 ['OP', 'OP'] unknown unresolved
Morning Light Wind Farm 57875 2025 ['OP'] unknown unresolved
Sunset Breeze LLC 56586 2025 ['OP'] unknown unresolved
Flat Ridge Wind Farm 56819 2025 ['OP'] unknown unresolved
Trimont Area Wind Farm 56296 2025 ['OP'] unknown unresolved
Pilot Hill Wind Farm 58898 2025 ['OP'] unknown unresolved
Prairie Wind Farm 60873 2025 ['OP'] unknown unresolved
Spearville 3 LLC 57975 2025 ['OP'] unknown unresolved
Terra-Gen 251 Wind LLC 52161 2025 ['RE'] unknown unresolved
Klondike Windpower II 56359 2025 ['OP'] unknown unresolved
Blackstone Wind Farm LLC 57110 2025 ['OP'] unknown unresolved
Sweetwater Wind 5 56372 2025 ['OP'] unknown unresolved
Flat Iron Wind (7) LLC 56839 2025 ['OP'] unknown unresolved
Twin Lake Hills LLC 55568 2025 ['OP'] unknown unresolved
Spring Canyon 56320 2025 ['OP'] unknown unresolved
Goodwell Wind Project LLC 58998 2025 ['OP'] unknown unresolved
Wind Colebrook South 60700 2025 ['OP'] unknown unresolved
BMP Wind (TX) 62809 2025 ['OP'] unknown unresolved
Blooming Grove Wind Energy Center 63988 2025 ['OP'] unknown unresolved
Marshall Wind 4 LLC 56826 2025 ['OP'] unknown unresolved
Fairhaven Wind 59725 2025 ['OP'] unknown unresolved
Lost Creek Wind Energy Facility 57189 2025 ['OP'] unknown unresolved
Buffalo Gap 2 Wind Farm 56484 2025 ['OP'] unknown unresolved
Iowa Distributed Wind Generation Project 7966 2025 ['OP'] unknown unresolved
Horse Butte Wind I LLC 57890 2025 ['OP'] unknown unresolved
North English 62133 2025 ['OP', 'OP'] unknown unresolved
Lookout Windpower LLC 56700 2025 ['OP'] unknown unresolved
Red Mesa Wind LLC 57357 2025 ['OP'] unknown unresolved
Pioneer Trail Wind Farm LLC 57675 2025 ['OP'] unknown unresolved
UMM Wind Turbine 57732 2025 ['OP'] unknown unresolved
Lane City Wind 67443 2025 ['OP'] unknown unresolved
Cisco 63431 2025 ['OP'] unknown unresolved
Elk City LLC 57346 2025 ['OP', 'OP'] unknown unresolved
MinnDakota Wind LLC 56459 2025 ['OP'] unknown unresolved
Sage Draw Wind 62620 2025 ['OP'] unknown unresolved
Buffalo Ridge I LLC 56792 2025 ['OP'] unknown unresolved
Pacific Canyon Windfarm LLC 56972 2025 ['OP'] unknown unresolved
Rocky Ridge Wind Project 58078 2025 ['OP'] unknown unresolved
Big Blue 57289 2025 ['OP'] unknown unresolved
Jett Creek Windfarm (Burnt River) 59490 2025 ['OP'] unknown unresolved
Minonk Wind Farm 57284 2025 ['OP'] unknown unresolved
Turkey Track Wind Energy LLC 56774 2025 ['OP'] unknown unresolved
Oak Tree Energy 59435 2025 ['OP'] unknown unresolved
Bayonne MUA- Leitner-Poma Wind Turbine 59797 2025 ['OS'] unknown unresolved
Cedar Creek II 57210 2025 ['OP'] unknown unresolved
Camp Reed 57125 2025 ['OP'] unknown unresolved
Whirlpool Corporation - Marion Wind Farm 61005 2025 ['OP', 'OP', 'OP'] unknown unresolved
Orient Wind Farm 61077 2025 ['OP', 'OP'] unknown unresolved
Prairie Breeze II 60262 2025 ['OP'] unknown unresolved
Pattern Gulf Wind 56661 2025 ['OP'] unknown unresolved
Tyler Bluff Wind Project LLC 60502 2025 ['OP'] unknown unresolved
Foundation Superior Farms 58104 2025 ['OP'] unknown unresolved
Hubbard Wind 65048 2025 ['OP'] unknown unresolved
Equity Industrial Turbines 60865 2025 ['OP'] unknown unresolved
Minwind 56002 2025 ['OP'] unknown unresolved
Pantex 58404 2025 ['OP'] unknown unresolved
Foundation Cemex Madison 58112 2025 ['OP'] unknown unresolved
Mars Hill Wind Farm Project 56448 2025 ['OP'] unknown unresolved
Ridgewind 57386 2025 ['OP'] unknown unresolved
Mammoth Plains 59284 2025 ['OP'] unknown unresolved
Salt Fork Wind Project LLC 60657 2025 ['OP'] unknown unresolved
Briscoe Wind Farm 59734 2025 ['OP'] unknown unresolved
NedPower Mount Storm 56495 2025 ['OP', 'OP'] unknown unresolved
Com Adam 1WF-1 58887 2025 ['OS', 'OP'] unknown unresolved
Spinning Spur Wind LLC 57973 2025 ['OP'] unknown unresolved
Roscoe Wind Farm LLC 56593 2025 ['OP'] unknown unresolved
Alta Wind Energy Center V 57294 2025 ['OP'] unknown unresolved
Teichert Materials-Teichert Vernalis 57594 2025 ['OP'] unknown unresolved
Euclid Farm Stamco N-54 59024 2025 ['OP'] unknown unresolved
Greenback Energy 56413 2025 ['OP'] unknown unresolved
Keenan II Renewable Energy Co LLC 57358 2025 ['OP'] unknown unresolved
Lake Winds Energy Park 57984 2025 ['OP'] unknown unresolved
WED Plainfield LLC 62109 2025 ['OP'] unknown unresolved
Brown County Wind Turbine 57767 2025 ['OA'] unknown unresolved
Brisket Wind (8) LLC 56838 2025 ['OP'] unknown unresolved
Cape Cod Air Force Station - 6 SWS 58661 2025 ['OP', 'OP'] unknown unresolved
Wildorado Wind LLC 56432 2025 ['OP'] unknown unresolved
Fairfield Wind 58966 2025 ['OP'] unknown unresolved
Harbec Energy 62736 2025 ['RE', 'RE'] unknown unresolved
Broadview Energy JN LLC 60145 2025 ['OP'] unknown unresolved
WED Shun II LLC 62111 2025 ['OP'] unknown unresolved
Panther Creek Wind Farm II 56921 2025 ['OP'] unknown unresolved
Red Pine Wind Project 61357 2025 ['OP'] unknown unresolved
Moraine Sands Wind Power 66093 2025 ['OP'] unknown unresolved
Foard City Wind 61402 2025 ['OP'] unknown unresolved
Goat Wind LP 56754 2025 ['OP', 'OP'] unknown unresolved
Diamond Spring, LLC 63327 2025 ['OP'] unknown unresolved
Blue Breezes II LLC 56581 2025 ['OP'] unknown unresolved
Old Settler Wind 60366 2025 ['OP'] unknown unresolved
Milo Wind Project LLC 59838 2025 ['OP'] unknown unresolved
Rollins Wind Project 56990 2025 ['OP'] unknown unresolved
Block Island Wind Farm 58035 2025 ['OP'] unknown unresolved
Charlestown Wind Turbine 58065 2025 ['OP'] unknown unresolved
Tule Wind LLC 57913 2025 ['OP'] unknown unresolved
Hog Creek Wind Project 61330 2025 ['OP'] unknown unresolved
Blue Canyon Windpower VI LLC 57616 2025 ['OP'] unknown unresolved
Luther College Wind Project 58407 2025 ['OP'] unknown unresolved
Route 66 Wind Plant 58681 2025 ['OP'] unknown unresolved
Springview 7771 2025 ['RE', 'RE'] unknown unresolved
Springview 7771 2025 ['OP', 'OP'] unknown unresolved
Solomon Forks Wind Project LLC 61984 2025 ['OP'] unknown unresolved
Zephyr Wind 60128 2025 ['OP', 'OP', 'OP'] unknown unresolved
Limestone Wind Project 65306 2025 ['OP'] unknown unresolved
Bull Creek Wind 56956 2025 ['OP'] unknown unresolved
Allegheny Ridge Wind Farm 56451 2025 ['OP'] unknown unresolved
Porterhouse Wind (4) LLC 56560 2025 ['OP'] unknown unresolved
Story City Wind Project 58927 2025 ['OP'] unknown unresolved
Terra-Gen VG Wind LLC 56570 2025 ['OP'] unknown unresolved
Laurel Wind Farm 57500 2025 ['OP'] unknown unresolved
Beebe 1A 58020 2025 ['OP'] unknown unresolved
Chestnut Flats Wind Farm 57268 2025 ['OP'] unknown unresolved
Golden Hills North Wind Energy Center 61222 2025 ['OP'] unknown unresolved
Jumbo Hill Wind Project 62630 2025 ['OP'] unknown unresolved
Iron Star Wind Project 64003 2025 ['OP'] unknown unresolved
Helzel & Schwarzhoff 86 56275 2025 ['OP'] unknown unresolved
TX Hereford Wind 58773 2025 ['OP'] unknown unresolved
Cimarron Wind Energy LLC 57762 2025 ['OP'] unknown unresolved
Voyager Wind IV 61584 2025 ['OP'] unknown unresolved
NaturEner Glacier Wind Energy 1 57049 2025 ['OP'] unknown unresolved
Shamrock Wind 66540 2025 ['OP'] unknown unresolved
GE - Tehachapi 57566 2025 ['RE', 'RE', 'RE', 'RE'] unknown unresolved
Creston Ridge Wind Farm 60932 2025 ['OP'] unknown unresolved
Klondike Windpower III 56468 2025 ['OP', 'OP'] unknown unresolved
Garnet Wind Energy Center 57302 2025 ['OP'] unknown unresolved
Western Plains Wind Farm 60689 2025 ['OP'] unknown unresolved
Greenfield Wind - MT 60486 2025 ['OP'] unknown unresolved
Spearville 56351 2025 ['OP', 'OP'] unknown unresolved
Beethoven Wind 59187 2025 ['OP'] unknown unresolved
Grant County Wind LLC 57274 2025 ['OP'] unknown unresolved
Pinyon Pine II 57837 2025 ['OP'] unknown unresolved
Ivester Wind Farm 61911 2025 ['OP'] unknown unresolved
Rattlesnake Den 59943 2025 ['OP'] unknown unresolved
Crossroads Wind Farm 57332 2025 ['OP'] unknown unresolved
White Cloud Wind Project, LLC 62624 2025 ['OP'] unknown unresolved
Mesquite Wind Power LLC 56395 2025 ['OP'] unknown unresolved
NaturEner Rim Rock Energy 57995 2025 ['OP'] unknown unresolved
TX Jumbo Road Wind 59621 2025 ['OP'] unknown unresolved
Post Oak Wind LLC 56483 2025 ['OP'] unknown unresolved
Georgia Mountain Community Wind Farm 58238 2025 ['OP'] unknown unresolved
Pilgrim Stage Wind Park 56440 2025 ['OP'] unknown unresolved
Cactus Flats Wind Energy Project 61001 2025 ['OP'] unknown unresolved
Crossing Trails Wind Power Project LLC. 62489 2025 ['OP'] unknown unresolved
Laredo Ridge Wind LLC 57262 2025 ['OP'] unknown unresolved
Chanarambie Power Partners LLC 56142 2025 ['RE'] unknown unresolved
Sweetland Wind Farm, LLC 66496 2025 ['OP'] unknown unresolved
Ranchero Wind Farm LLC 62259 2025 ['OP'] unknown unresolved
Heritage Garden Wind Farm I LLC 58103 2025 ['OP'] unknown unresolved
Fenton Wind Farm 56617 2025 ['OP'] unknown unresolved
Passadumkeag Windpark LLC 59222 2025 ['OP'] unknown unresolved
WED Plainfield III LLC 62108 2025 ['OP'] unknown unresolved
Big Horn Wind II 57319 2025 ['OP'] unknown unresolved
Rising Tree Wind Farm II 59235 2025 ['OP'] unknown unresolved
Solano Wind 7526 2025 ['RE', 'CN'] unknown unresolved
Solano Wind 7526 2025 ['OP', 'OP', 'OP', 'OP'] unknown unresolved
Mehoopany Wind Energy LLC 57769 2025 ['OP'] unknown unresolved
Hoopeston Wind LLC 59021 2025 ['OP'] unknown unresolved
WED Coventry 3 59305 2025 ['OP'] unknown unresolved
Beaver Ridge Wind 57130 2025 ['OP'] unknown unresolved
Mower County Wind Energy Center 56424 2025 ['OP'] unknown unresolved
Tsar Nicholas LLC 55561 2025 ['OP'] unknown unresolved
Polk County Renewables LLC 62333 2025 ['OP'] unknown unresolved
Sleeping Bear LLC 56621 2025 ['OP'] unknown unresolved
Marble River Wind Farm 56857 2025 ['OP'] unknown unresolved
Taloga Wind LLC 57261 2025 ['OP'] unknown unresolved
Elm Creek Wind II LLC 57649 2025 ['OP'] unknown unresolved
Montezuma Wind II 57701 2025 ['OP'] unknown unresolved
Walnut Ridge Wind Farm 58694 2025 ['OP'] unknown unresolved
Golden Spread Panhandle Wnd Rch 57866 2025 ['OP'] unknown unresolved
Cashton Greens Wind Farm 57968 2025 ['OP'] unknown unresolved
Caprock Wind Farm 56293 2025 ['OP', 'OP'] unknown unresolved
GL Wind 57813 2025 ['OP', 'OP'] unknown unresolved
Meadow Lake Wind Farm LLC 57109 2025 ['OP'] unknown unresolved
Lundgren Wind Project 58884 2025 ['OP'] unknown unresolved
Spring Valley Wind Project 57192 2025 ['OP'] unknown unresolved
T-Bone Wind (10) LLC 56836 2025 ['OP'] unknown unresolved
G Flow Wind LLC 56588 2025 ['OP'] unknown unresolved
Moraine Wind LLC 56174 2025 ['OP'] unknown unresolved
Lakota Wind Wind Farm 57251 2025 ['OP'] unknown unresolved
Iowa Lakes Community College Wind Farm 57257 2025 ['OP'] unknown unresolved
Agassiz Beach LLC 55576 2025 ['OP'] unknown unresolved
Kings Point Wind Energy Center 62475 2025 ['OP'] unknown unresolved
Jiminy Peak Wind QF 62570 2025 ['OP'] unknown unresolved
Gratiot Wind Park 57421 2025 ['OP'] unknown unresolved
REG Juhl Glenville Wind, LLC 64130 2025 ['OP'] unknown unresolved
CG Windfarm LLC 56200 2025 ['OP'] unknown unresolved
Voyager Wind II 61582 2025 ['OP'] unknown unresolved
Wake Wind Energy Center 58766 2025 ['CN', 'CN'] unknown unresolved
Wake Wind Energy Center 58766 2025 ['OP'] unknown unresolved
Hackberry Wind Farm 56823 2025 ['OP'] unknown unresolved
FPL Energy Oliver Wind II LLC 56573 2025 ['OP'] unknown unresolved
Willow Spring Windfarm (Burnt River) 59494 2025 ['OP'] unknown unresolved
Two Ponds Windfarm 57444 2025 ['OP'] unknown unresolved
Voyager Wind III 61583 2025 ['OP'] unknown unresolved
Foundation Cemex BMQ 58102 2025 ['OP', 'OP'] unknown unresolved
Wessington Springs 56650 2025 ['OP'] unknown unresolved
Windom Wind Project 56544 2025 ['OP'] unknown unresolved
Macksburg Wind Project 58885 2025 ['OP'] unknown unresolved
Jericho Power 59070 2025 ['OP'] unknown unresolved
Border Winds Wind Farm 59200 2025 ['OP'] unknown unresolved
Lost Lakes Wind Farm LLC 57111 2025 ['OP'] unknown unresolved
Inertia Wind Project 65546 2025 ['OP'] unknown unresolved
Great Western Wind Energy LLC 60574 2025 ['OP'] unknown unresolved
Vantage Wind Energy LLC 57188 2025 ['OP'] unknown unresolved
Montgomery Ranch Wind Farm, LLC 67095 2025 ['OP'] unknown unresolved
WED Shun I LLC 62110 2025 ['OP'] unknown unresolved
Elk Wind Farm 57417 2025 ['OP'] unknown unresolved
Garden Wind LLC 57469 2025 ['OP'] unknown unresolved
Lincoln Heights I 63432 2025 ['OP'] unknown unresolved
Cimarron Bend Wind Project II LLC 60688 2025 ['OP'] unknown unresolved
High Sheldon Wind Farm 56953 2025 ['OP'] unknown unresolved
Foote Creek III 55609 2025 ['RE'] unknown unresolved
Blue Canyon Windpower V LLC 57108 2025 ['OP'] unknown unresolved
Forward Windpower LLC 56699 2025 ['OP'] unknown unresolved
Northern Lights Wind LLC 56411 2025 ['OP'] unknown unresolved
FPL Energy North Dakota Wind I/II 56099 2025 ['OP'] unknown unresolved
Longhorn Wind 58772 2025 ['OP'] unknown unresolved
Galactic Wind 62161 2025 ['OP'] unknown unresolved
Rio Bravo Windpower LLC 61865 2025 ['OP'] unknown unresolved
Dutch Wind Energy 57301 2025 ['RE'] unknown unresolved
Perennial Windfarm 61677 2025 ['OP', 'OP', 'OP'] unknown unresolved
Osage Wind LLC 58683 2025 ['OP'] unknown unresolved
FPL Energy Burleigh County Wind 56357 2025 ['OP', 'OP'] unknown unresolved
Condon Windpower LLC 55739 2025 ['OP', 'OP'] unknown unresolved
San Gorgonio Westwinds II LLC 50690 2025 ['OP'] unknown unresolved
Stoneray Power Partners LLC 62269 2025 ['OP'] unknown unresolved
Oak Creek Energy Systems I 50754 2025 ['OP', 'OP', 'OP', 'OP'] unknown unresolved
Marshall Wind 1 LLC 56840 2025 ['OP'] unknown unresolved
Voyager Wind I 60594 2025 ['OP'] unknown unresolved
Camp Grove Wind Farm 56640 2025 ['OP'] unknown unresolved
Tuscola Bay Wind 58351 2025 ['OP'] unknown unresolved
Sigel Wind Park 57851 2025 ['OP'] unknown unresolved
Vansycle 55125 2025 ['OP'] unknown unresolved
Oakfield Wind Project 57002 2025 ['OP'] unknown unresolved
Cohocton Wind Project 56634 2025 ['OP'] unknown unresolved
Limon Wind I 58126 2025 ['OP'] unknown unresolved
Champepaden Wind Power 55980 2025 ['RE'] unknown unresolved
Lamar Plant 508 2025 ['OP', 'OP'] unknown unresolved
Tuana Gulch Wind Park 56443 2025 ['OP'] unknown unresolved
Foundation RRM 58113 2025 ['OP', 'OP'] unknown unresolved
Seven Cowboy Wind Project, LLC 65971 2025 ['OP'] unknown unresolved
Kawailoa Wind 57529 2025 ['OP'] unknown unresolved
Grant Wind LLC 60013 2025 ['OP'] unknown unresolved
Whirlwind Energy Center 56673 2025 ['OP'] unknown unresolved
Casper Wind Farm 57093 2025 ['OP'] unknown unresolved
Tofteland Windfarm LLC 56202 2025 ['OP'] unknown unresolved
Elkhorn Ridge Wind LLC 56947 2025 ['OP'] unknown unresolved
California Ridge Wind Energy LLC 58008 2025 ['OP'] unknown unresolved
Willow Springs Wind Farm 60901 2025 ['OP'] unknown unresolved
Broken Bow Wind II LLC 58981 2025 ['OP'] unknown unresolved
Rush Springs Wind 60592 2025 ['OP'] unknown unresolved
Foundation ST 57626 2025 ['OP'] unknown unresolved
Strauss Wind Farm 62113 2025 ['OP'] unknown unresolved
Spring Canyon Expansion Wind Energy Ctr 58769 2025 ['OP', 'OP'] unknown unresolved
Buffalo Mountain 7927 2025 ['RE', 'RE', 'RE'] unknown unresolved
Golden Hills Wind 60049 2025 ['OP'] unknown unresolved
Kit Carson Windpower 57244 2025 ['OP'] unknown unresolved
Seiling Wind II 59312 2025 ['OP'] unknown unresolved
Jack River LLC 55565 2025 ['OP'] unknown unresolved
Campbell Hill Windpower 57090 2025 ['OP'] unknown unresolved
Crofton Bluffs Wind LLC 57278 2025 ['OP'] unknown unresolved
Sun River LLC 55562 2025 ['OP'] unknown unresolved
Findlay Wind Farm 60015 2025 ['OP'] unknown unresolved
Prescott Wind Farm 66952 2025 ['OP'] unknown unresolved
Minden Wind Park 57852 2025 ['OP'] unknown unresolved
Langdon Renewables LLC 56605 2025 ['OP'] unknown unresolved
Tehachapi Wind Resource I 10191 2025 ['CN'] unknown unresolved
Tehachapi Wind Resource I 10191 2025 ['OP'] unknown unresolved
WED Shun III LLC 62112 2025 ['OP'] unknown unresolved
Pleasant Hill Wind Energy Project 59417 2025 ['OP'] unknown unresolved
Sagamore Wind 63578 2025 ['OP'] unknown unresolved
Hoosier Wind Project LLC 56878 2025 ['OP'] unknown unresolved
Courtenay Wind Farm 58658 2025 ['OP'] unknown unresolved
Shiloh III Wind Project LLC 57586 2025 ['OP'] unknown unresolved
Carroll Wind Farm 56809 2025 ['OP'] unknown unresolved
Jericho Rise Wind Farm LLC 59629 2025 ['OP'] unknown unresolved
Milford Wind Corridor I LLC 57079 2025 ['OP'] unknown unresolved
Oregon Trail Wind Park 56439 2025 ['OP'] unknown unresolved
La Casa Wind 66919 2025 ['OP'] unknown unresolved
FPL Energy Vansycle LLC (OR) 55989 2025 ['OP'] unknown unresolved
Alexander Wind Farm LLC 58666 2025 ['OP'] unknown unresolved
Hawkeye Wind Farm 57832 2025 ['OP'] unknown unresolved
Valley View Transmission LLC 57434 2025 ['OP'] unknown unresolved
Difwind Farms Ltd I 54681 2025 ['RE'] unknown unresolved
Wolf Ridge Wind 58080 2025 ['OP'] unknown unresolved
Coastal Energy Project 57756 2025 ['OP'] unknown unresolved
Majestic II Wind 58363 2025 ['OP'] unknown unresolved
Redwood Falls Wind 56414 2025 ['OP', 'OP'] unknown unresolved
Junction Hilltop Wind Farm 58444 2025 ['OP'] unknown unresolved
Mountain View III 56112 2025 ['OP'] unknown unresolved
Sheffield Wind 57080 2025 ['OP'] unknown unresolved
High Mesa 58019 2025 ['OP'] unknown unresolved
Tuana Springs 57136 2025 ['OP'] unknown unresolved
Hawkeye Power Partners LLC 55816 2025 ['OP'] unknown unresolved
Gray County Wind Energy 55734 2025 ['OP'] unknown unresolved
Hidalgo Wind Farm LLC 57617 2025 ['OP'] unknown unresolved
Eight Point Wind 66052 2025 ['OP'] unknown unresolved
Moorhead Wind Turbine 7855 2025 ['OP', 'OP'] unknown unresolved
Carousel Wind Farm LLC 59975 2025 ['OP'] unknown unresolved
Vienna Wind Farm 57874 2025 ['OP', 'OP'] unknown unresolved
Grady Wind Energy Center LLC 60317 2025 ['OP'] unknown unresolved
Armadillo Flats Wind Project LLC 61926 2025 ['OP'] unknown unresolved
Turtle Creek Wind Farm LLC 61638 2025 ['OP'] unknown unresolved
Heartland Divide Wind Project LLC 61609 2025 ['OP'] unknown unresolved
Searsburg Wind Turbine 7381 2025 ['OP'] unknown unresolved
Springfield Wind 67160 2025 ['OP'] unknown unresolved
Cow Branch 56536 2025 ['OP'] unknown unresolved
Little Elk Wind Project LLC 58999 2025 ['OP'] unknown unresolved
Cirrus Wind 1 LLC 58162 2025 ['OP'] unknown unresolved
Howard Wind Farm 57867 2025 ['OP', 'OP'] unknown unresolved
Pine River Wind Park 61106 2025 ['OP'] unknown unresolved
Tuscola Wind II LLC 58587 2025 ['OP'] unknown unresolved
Bronco Plains Wind, LLC 63803 2025 ['OP'] unknown unresolved
Wethersfield Wind Farm 55368 2025 ['RE'] unknown unresolved
DL Windy Acres LLC 56207 2025 ['OP'] unknown unresolved
Wilton Wind II LLC 57120 2025 ['OP'] unknown unresolved
Salt Valley Wind Plant 7965 2025 ['RE', 'RE'] unknown unresolved
Hart Wind 67763 2025 ['OP'] unknown unresolved
Stony Creek Wind Farm LLC 56980 2025 ['OP'] unknown unresolved
Huerfano River Wind 58548 2025 ['OP', 'OP', 'OP', 'OP'] unknown unresolved
Montague Wind Power Facility LLC 58099 2025 ['OP'] unknown unresolved
Wheat Field Wind Power Project 56854 2025 ['OP'] unknown unresolved
Ward Butte Windfarm LLC 56975 2025 ['OP'] unknown unresolved
Burley Butte Windpark 56434 2025 ['OP'] unknown unresolved
CED Mason City Wind 63521 2025 ['OP'] unknown unresolved
Colorado Highlands Wind 57174 2025 ['CN'] unknown unresolved
Colorado Highlands Wind 57174 2025 ['OP', 'OP'] unknown unresolved
Rush Creek Wind 60619 2025 ['OP'] unknown unresolved
Anticline Wind 67193 2025 ['OP'] unknown unresolved
Aviator Wind 63209 2025 ['OP'] unknown unresolved
Spanish Fork Wind Park 2 LLC 56751 2025 ['OP'] unknown unresolved
Lempster Wind LLC 56399 2025 ['OP'] unknown unresolved
Ashtabula Wind III LLC 57387 2025 ['OP'] unknown unresolved
Sand Ranch Windfarm LLC 56973 2025 ['OP'] unknown unresolved
EDF Renewable Windfarm V Inc 54453 2025 ['OP'] unknown unresolved
Autumn Hills LLC 55566 2025 ['OP'] unknown unresolved
Rising Tree Wind Farm III 59236 2025 ['OP'] unknown unresolved
Settlers Trail Wind Farm LLC 57493 2025 ['OP'] unknown unresolved
Silver Sage Windpower 57091 2025 ['OP'] unknown unresolved
Glacier Sands Wind Power, LLC 64381 2025 ['OP'] unknown unresolved
Buffalo Ridge II LLC 57424 2025 ['OP'] unknown unresolved
Whitewater Hill Wind Partners 56012 2025 ['OP'] unknown unresolved
Hancock County Wind Energy Center 56010 2025 ['OP'] unknown unresolved
Freeborn Wind Farm 64623 2025 ['OP'] unknown unresolved
Spartan Hills LLC 55569 2025 ['OP'] unknown unresolved
San Juan Mesa Wind Project LLC 56304 2025 ['OP'] unknown unresolved
Jessica Mills LLC 55564 2025 ['OP'] unknown unresolved
Karen Avenue Wind Farm 10718 2025 ['OP'] unknown unresolved
Senate Wind LLC 57981 2025 ['OP'] unknown unresolved
McKinley Wind Park 57853 2025 ['OP'] unknown unresolved
Foundation CDCR LAC 61066 2025 ['OP'] unknown unresolved
Steel Winds Wind Farm 56575 2025 ['OP'] unknown unresolved
Flat Ridge Wind Energy LLC 56879 2025 ['OP'] unknown unresolved
Cedro Hill Wind LLC 57260 2025 ['OP', 'OP'] unknown unresolved
Lime Wind 57803 2025 ['OP'] unknown unresolved
Michelangelo Wind 1 LLC 59231 2025 ['OP'] unknown unresolved
Marshall Wind 3 LLC 56825 2025 ['OP'] unknown unresolved
Horizon Hill Wind Project 64339 2025 ['OP'] unknown unresolved
Ruthton Ridge LLC 55571 2025 ['OP'] unknown unresolved
Live Oak Wind Project 61782 2025 ['OP'] unknown unresolved
Waymart Wind 56001 2025 ['OP'] unknown unresolved
South Hurlburt Wind LLC 57549 2025 ['OP'] unknown unresolved
Fluvanna 59245 2025 ['OP'] unknown unresolved
Pyron Wind Farm LLC Hybrid 56981 2025 ['OP'] unknown unresolved
Northwest Ohio Wind 59296 2025 ['CN'] unknown unresolved
Northwest Ohio Wind 59296 2025 ['OP'] unknown unresolved
Prairie Breeze III 60314 2025 ['OP'] unknown unresolved
Minot Wind Project 55995 2025 ['RE'] unknown unresolved
Minot Wind Project 55995 2025 ['OP'] unknown unresolved
Alta Wind Energy Center II 57291 2025 ['OP'] unknown unresolved
Barton Windpower LLC 56765 2025 ['OP', 'OP'] unknown unresolved
Arlington Wind Power Project 56855 2025 ['OP'] unknown unresolved
Poseidon Wind LLC 57379 2025 ['OP'] unknown unresolved
Windy Flats Wind Project 57159 2025 ['OP'] unknown unresolved
Grant Plains Wind LLC 60545 2025 ['OP'] unknown unresolved
Lacy Creek Wind Energy Center 65162 2025 ['OP'] unknown unresolved
Rising Tree Wind Farm 57621 2025 ['OP'] unknown unresolved
DeWind Frisco 57517 2025 ['RE'] unknown unresolved
Community Wind North LLC 57385 2025 ['OP'] unknown unresolved
New Harvest Wind Project LLC 57609 2025 ['OP'] unknown unresolved
Northern Iowa Windpower II 56383 2025 ['OP'] unknown unresolved
Seneca Nation Cattaraugus Wind Turbine 61734 2025 ['OP'] unknown unresolved
Odell Wind Farm 58657 2025 ['OP'] unknown unresolved
Dept of Corrections NCCI Wind 58992 2025 ['OP', 'OP'] unknown unresolved
KODE Novus II 57889 2025 ['RE'] unknown unresolved
Victory Garden (Tehachapi) 50532 2025 ['OP', 'OP'] unknown unresolved
Osceola Windpower II 56913 2025 ['OP'] unknown unresolved
FPL Energy Vansycle LLC (WA) 55560 2025 ['OP'] unknown unresolved
Greensburg 57118 2025 ['OP'] unknown unresolved
Ridgetop 54931 2025 ['OP'] unknown unresolved
Jordan Creek Wind Farm, LLC 63389 2025 ['OP'] unknown unresolved
Bishop Hill Energy LLC 57463 2025 ['OP'] unknown unresolved
Big Level Wind 60551 2025 ['OP'] unknown unresolved
Downeast Wind 68185 2025 ['OP'] unknown unresolved
Lockett Windfarm 62356 2025 ['OP'] unknown unresolved
Horse Creek Wind Farm 60339 2025 ['OP'] unknown unresolved
Big Horn Wind Project 56361 2025 ['OP'] unknown unresolved
Windland 50386 2025 ['RE'] unknown unresolved
Somerset Windpower LLC 55803 2025 ['OP'] unknown unresolved
San Gorgonio Windplant WPP1993 54454 2025 ['RE'] unknown unresolved
San Gorgonio Windplant WPP1993 54454 2025 ['OP'] unknown unresolved
Heartland Farms 66192 2025 ['OP'] unknown unresolved
Sunray Wind I 57326 2025 ['OP'] unknown unresolved
Bluegrass Ridge 56555 2025 ['OP'] unknown unresolved
Redbed Plains Wind Farm 61221 2025 ['OP'] unknown unresolved
Fowler Ridge IV Wind Farm LLC 59547 2025 ['OP'] unknown unresolved
Adair Wind Farm 56810 2025 ['OP'] unknown unresolved
Rock River I LLC 55740 2025 ['RE'] unknown unresolved
Ainsworth Wind 56162 2025 ['OP'] unknown unresolved
Campbell County Wind Farm 59655 2025 ['OP'] unknown unresolved
Fire Island Wind 58425 2025 ['OP'] unknown unresolved
Brady II Wind Energy Center 60354 2025 ['OP'] unknown unresolved
Rolling Thunder Wind Farm Hybrid 57045 2025 ['OP'] unknown unresolved
Lake Benton I 55208 2025 ['OP'] unknown unresolved
WED Portsmouth One LLC 61002 2025 ['OP'] unknown unresolved
Lake Benton II 55265 2025 ['OP'] unknown unresolved
Woodstock Windfarm 55342 2025 ['OP'] unknown unresolved
Threemile Canyon 56933 2025 ['OP'] unknown unresolved
Rockland Wind Farm 57766 2025 ['OP'] unknown unresolved
Sapphire Sky Wind Energy LLC 65316 2025 ['OP'] unknown unresolved
Armenia Mountain Wind Farm 57044 2025 ['OP'] unknown unresolved
Stetson Wind I 56989 2025 ['OP'] unknown unresolved
Buena Vista Energy LLC 56446 2025 ['OP'] unknown unresolved
Hope Creek LLC 55572 2025 ['OP'] unknown unresolved
Traverse Wind Project, LLC 63479 2025 ['OP'] unknown unresolved
Brookfield Tehachapi 1 57962 2025 ['OP'] unknown unresolved
Judith Gap Wind Energy Center 56377 2025 ['OP'] unknown unresolved
Big Spring Wind Power Facility 54979 2025 ['OP'] unknown unresolved
Valfilm Wind Project 61356 2025 ['OP', 'OP'] unknown unresolved
Whispering Willow Wind Farm - East 56355 2025 ['OP'] unknown unresolved
Red Cloud Wind LLC 63981 2025 ['OP'] unknown unresolved
Alta Wind Energy Center I 57282 2025 ['OP'] unknown unresolved
WED Coventry 4 59306 2025 ['OP'] unknown unresolved
S&P Windfarm LLC 56208 2025 ['OP'] unknown unresolved
Harvest Wind Project 57152 2025 ['OP'] unknown unresolved
Kimball Wind 56106 2025 ['RE'] unknown unresolved
Kimball Wind 56106 2025 ['OP'] unknown unresolved
Century 56252 2025 ['OP', 'OP', 'OP'] unknown unresolved
FPL Energy Ashtabula Wind LLC 56919 2025 ['OP'] unknown unresolved
Laurel Hill Wind 57744 2025 ['OP'] unknown unresolved
Crossover Wind 67959 2025 ['OP'] unknown unresolved
Willow Creek Energy Center 56952 2025 ['OP'] unknown unresolved
Buffalo Center Wind LLC 58038 2025 ['OP'] unknown unresolved
Javelina Wind Energy II LLC 60645 2025 ['OP'] unknown unresolved
Peyton Creek Wind Farm LLC 62417 2025 ['OP'] unknown unresolved
Optimum Wind 4 LLC 59226 2025 ['OP'] unknown unresolved
Pioneer Wind Park LLC 60259 2025 ['OP'] unknown unresolved
Michelangelo Wind 3 LLC 59053 2025 ['OP'] unknown unresolved
CCC Hastings Wind Turbine 60931 2025 ['OP'] unknown unresolved
WED Coventry 6 59314 2025 ['OP', 'OP', 'OP'] unknown unresolved
Broken Bow Wind LLC 57593 2025 ['OP'] unknown unresolved
Gopher Creek Wind Farm 61417 2025 ['OP'] unknown unresolved
Cameron Ridge LLC 10586 2025 ['OP'] unknown unresolved
Ocotillo Windpower 56959 2025 ['OP'] unknown unresolved
Foundation Cemex River Plant 58101 2025 ['OP', 'OP'] unknown unresolved
Iowa Lakes Superior Wind Farm 57252 2025 ['OP'] unknown unresolved
Buffalo Bear LLC 56946 2025 ['OP'] unknown unresolved
Record Hill Wind 57568 2025 ['OP'] unknown unresolved
New England Wind LLC 57380 2025 ['OP'] unknown unresolved
Nine Canyon 7936 2025 ['OP'] unknown unresolved
Balko Wind LLC 58900 2025 ['OP'] unknown unresolved
High Banks Wind 66156 2025 ['OP'] unknown unresolved
Mustang Hills LLC 57833 2025 ['OP'] unknown unresolved
Pattern Panhandle Wind LLC 58242 2025 ['OP'] unknown unresolved
Greenfield Wind 58458 2025 ['OP'] unknown unresolved
Marsh Hill Wind Farm 58768 2025 ['OP'] unknown unresolved
Luverne Wind Energy Center 57031 2025 ['OP'] unknown unresolved
Bowman Wind 68182 2025 ['OP'] unknown unresolved
Goshen Phase II 57211 2025 ['OP'] unknown unresolved
Benton County Wind Farm 56679 2025 ['OP'] unknown unresolved
Eclipse Wind Farm 57873 2025 ['OP'] unknown unresolved
Ensign Wind LLC 58137 2025 ['OP'] unknown unresolved
Cedar Bluff Wind LLC 60069 2025 ['OP'] unknown unresolved
Highland Wind Project (IA) 58883 2025 ['OP', 'OP', 'OP', 'OP', 'OP', 'OP', 'OP'] unknown unresolved
Velva Windfarm LLC 56670 2025 ['OP'] unknown unresolved
Birch 62172 2025 ['OP'] unknown unresolved
Mountaineer Wind Energy Center 55986 2025 ['OP'] unknown unresolved
Cassia Gulch 56935 2025 ['OP'] unknown unresolved
Traer Wind Project 58932 2025 ['OP'] unknown unresolved
Bennington Wind 63384 2025 ['OP'] unknown unresolved
Jersey-Atlantic Wind Farm 56300 2025 ['OP'] unknown unresolved
Meadow Ridge 58459 2025 ['OP'] unknown unresolved
Miami Wind Energy Center 58765 2025 ['OP'] unknown unresolved
Bison I Wind Energy Center 57038 2025 ['OP', 'OP'] unknown unresolved
Top of Iowa Windfarm III 56386 2025 ['OP'] unknown unresolved
Criterion 57300 2025 ['OP'] unknown unresolved
WED Coventry 2 59302 2025 ['OP', 'OP', 'OP'] unknown unresolved
Cross Winds Energy Park 58830 2025 ['OP', 'OP', 'OP'] unknown unresolved
Western Trail Wind, LLC 64149 2025 ['OP'] unknown unresolved
Diamond Willow Wind Facility 56782 2025 ['OP'] unknown unresolved
Raymond Wind Farm, LLC 62909 2025 ['OP'] unknown unresolved
Baldwin Wind LLC 57347 2025 ['OP'] unknown unresolved
Lakota Ridge LLC 55353 2025 ['OP'] unknown unresolved
Crane Creek Wind Energy Center 56831 2025 ['OP'] unknown unresolved
Deerfield Wind Energy LLC 60883 2025 ['OP', 'OP', 'OP'] unknown unresolved
Dillon Wind LLC 56791 2025 ['OP'] unknown unresolved
Colorado Green Holdings LLC 56173 2025 ['OP'] unknown unresolved
English Farms 61565 2025 ['OP'] unknown unresolved
Winona County Wind LLC 57547 2025 ['OS'] unknown unresolved
Mendota Hills LLC 56160 2025 ['OP'] unknown unresolved
Dutch Hill Wind Project 56633 2025 ['OP'] unknown unresolved
Crosswind Energy Project 56859 2025 ['OP'] unknown unresolved
Wapsipinicon Wind Project 56876 2025 ['OP'] unknown unresolved
Wellsburg Wind Project 58886 2025 ['OP'] unknown unresolved
Northern Colorado Wind LLC 57290 2025 ['OP', 'OP'] unknown unresolved
Isabella Wind Park 63601 2025 ['OP'] unknown unresolved
Cumberland Rose 58456 2025 ['OP'] unknown unresolved
Shirley Wind 57553 2025 ['OP'] unknown unresolved
Minco Wind III LLC 58203 2025 ['OP'] unknown unresolved
Hale Community Wind Farm 59247 2025 ['CN'] unknown unresolved
Hale Community Wind Farm 59247 2025 ['OP'] unknown unresolved
High Plains 57040 2025 ['OP'] unknown unresolved
Wildcat Creek Wind Farm LLC 62715 2025 ['OP'] unknown unresolved
Chapman Ranch Wind I 59193 2025 ['OP'] unknown unresolved
Highland North Wind Farm 57991 2025 ['OP'] unknown unresolved
Seward Wind Farm 61056 2025 ['OP'] unknown unresolved
Golden Plains 62081 2025 ['OP'] unknown unresolved
Alta Wind VIII 57835 2025 ['OP'] unknown unresolved
Benson Creek Windfarm (Burnt River) 59491 2025 ['OP'] unknown unresolved
Osborn Wind Energy 60672 2025 ['OP'] unknown unresolved
FPL Energy Oliver Wind I LLC 56392 2025 ['OP'] unknown unresolved
Tahoka Wind 61921 2025 ['OP'] unknown unresolved
Ridgetop Energy LLC 10597 2025 ['OP'] unknown unresolved
Sweetwater Wind 3 LLC 56311 2025 ['OP'] unknown unresolved
Top Hat Wind 69225 2025 ['OP'] unknown unresolved
Sky Volt 58460 2025 ['OP'] unknown unresolved
Maverick Creek Wind 62853 2025 ['OP'] unknown unresolved
Montfort Wind Energy Center 55742 2025 ['OP'] unknown unresolved
Auwahi Wind Energy Hybrid 57996 2025 ['OP'] unknown unresolved
Wild Horse 56322 2025 ['OP', 'OP'] unknown unresolved
TPC Windfarms LLC 54647 2025 ['OP'] unknown unresolved
Little Pringle II Wind Farm 57264 2025 ['RE'] unknown unresolved
Waverly Wind Farm LLC 57614 2025 ['OP'] unknown unresolved
Cedar Hills Wind Farm 57171 2025 ['OP'] unknown unresolved
Jeffers Wind 20 LLC 56750 2025 ['OP'] unknown unresolved
Glacier Hills 57199 2025 ['OP'] unknown unresolved
Hull Wind II 56800 2025 ['RE'] unknown unresolved
Heartland Community College 59776 2025 ['OP'] unknown unresolved
Great Plains Windpark LLC 56905 2025 ['OP'] unknown unresolved
Grand Meadow 56994 2025 ['OP'] unknown unresolved
ZCO 56276 2025 ['OP'] unknown unresolved
Taylor Farms 59330 2025 ['OP'] unknown unresolved
Papalote Creek I LLC 56983 2025 ['OP'] unknown unresolved
Providence Heights Wind LLC 56622 2025 ['OP'] unknown unresolved
Arbuckle Mountain Wind Farm LLC 59234 2025 ['OP'] unknown unresolved
Windwalkers LLC 58071 2025 ['OP'] unknown unresolved
Kas Brothers Windfarm 55809 2025 ['OP'] unknown unresolved
Green Pastures Wind II 59733 2025 ['OP'] unknown unresolved
Peak View Wind Farm 60143 2025 ['OP'] unknown unresolved
Berkshire Wind Power Project 57721 2025 ['OP', 'OP', 'OP'] unknown unresolved
Chisholm View Wind Project 58041 2025 ['OP', 'OP'] unknown unresolved
Fowler Ridge Wind Farm LLC 56777 2025 ['OP', 'OP', 'OP', 'OP', 'OP'] unknown unresolved
Tenderloin Wind (6) LLC 56562 2025 ['OP'] unknown unresolved
Vasco Winds 57700 2025 ['OP'] unknown unresolved
RP Wind 58630 2025 ['OP'] unknown unresolved
NextEra-Blackwell Wind LLC 58209 2025 ['OP'] unknown unresolved
Shaokatan Hills LLC 55354 2025 ['OP'] unknown unresolved
Wind Park Bear Creek 56299 2025 ['OP'] unknown unresolved
Arbor Hill Wind Farm 62132 2025 ['OP', 'OP'] unknown unresolved
Oregon Trail Windfarm LLC 56971 2025 ['OP'] unknown unresolved
Foote Creek IV 55610 2025 ['RE'] unknown unresolved
Tatanka Wind Power LLC 56669 2025 ['OP'] unknown unresolved
Elk River Wind 56303 2025 ['OP'] unknown unresolved
Roth Rock North Wind Farm LLC 57240 2025 ['OP'] unknown unresolved
Pebble Springs Wind LLC 56789 2025 ['OP'] unknown unresolved
Diamond Trail Wind Farm 63641 2025 ['OP'] unknown unresolved
Bright Stalk Wind Farm I 57623 2025 ['OP'] unknown unresolved
Ridge Crest Wind Partners 55741 2025 ['RE'] unknown unresolved
Foote Creek II 55608 2025 ['RE'] unknown unresolved
Timbermill Wind, LLC 67910 2025 ['OP'] unknown unresolved
Marshall Wind Farm 59084 2025 ['OP'] unknown unresolved
Wildcat Wind 57887 2025 ['OP'] unknown unresolved
New Creek Wind 60132 2025 ['OP'] unknown unresolved
Franklin County Wind Farm 57844 2025 ['OP'] unknown unresolved
Camelot Wind LLC 58958 2025 ['OP'] unknown unresolved
Lower Snake River Wind Energy Project 57195 2025 ['OP'] unknown unresolved
Bethel Wind Farm LLC 60414 2025 ['OP'] unknown unresolved
Broadview Energy KW LLC 60152 2025 ['OP'] unknown unresolved
South Plains Wind Phase I 59384 2025 ['OP'] unknown unresolved
Wagner Wind LLC 58233 2025 ['OP'] unknown unresolved
Odin Wind Farm LLC 56755 2025 ['OP'] unknown unresolved
Allendorf 56215 2025 ['OS', 'OS', 'OS', 'OS'] unknown unresolved
Busch Ranch II Wind Farm 62445 2025 ['OP'] unknown unresolved
Carstensen Wind 56410 2025 ['OP'] unknown unresolved
Desert Sky 55992 2025 ['OP'] unknown unresolved
Stanton Wind Energy LLC 56644 2025 ['OP'] unknown unresolved
Beaver Creek Wind 61079 2025 ['OP', 'OP'] unknown unresolved
Mountain Wind Power II LLC 56753 2025 ['OP'] unknown unresolved
Steele Flats Wind Project LLC 58594 2025 ['OP'] unknown unresolved
Castle Gap Wind 65790 2025 ['OP'] unknown unresolved
Forest Creek Wind Farm LLC 56394 2025 ['OP'] unknown unresolved
Leonardo Wind 1 LLC 59228 2025 ['OP'] unknown unresolved
Fairbanks Wind Park 62815 2025 ['OP'] unknown unresolved
Ipswich Wind Turbine 57855 2025 ['OP'] unknown unresolved
Rosewater Wind Farm 62891 2025 ['OP'] unknown unresolved
Medicine Bow 692 2025 ['RE', 'RE', 'CN', 'CN', 'RE', 'RE'] unknown unresolved
Wind Turbine 7886 2025 ['OP'] unknown unresolved
Cameron Wind 1 LLC 59118 2025 ['OP'] unknown unresolved
Shiloh IV Wind Project LLC 57725 2025 ['OP'] unknown unresolved
Patton Wind Farm 57999 2025 ['OP'] unknown unresolved
Alta Wind XI 58395 2025 ['OP'] unknown unresolved
Pattern Panhandle Wind 2 LLC 58720 2025 ['OP'] unknown unresolved
Black Oak Wind Farm 58692 2025 ['OP'] unknown unresolved
Papalote Creek II LLC 57212 2025 ['OP'] unknown unresolved
North Sky River Energy LLC 58154 2025 ['OP'] unknown unresolved
Torrecillas Wind Energy LLC 61969 2025 ['OP'] unknown unresolved
Dans Mountain 67962 2025 ['OP'] unknown unresolved
Champion Wind Farm LLC 56592 2025 ['OP'] unknown unresolved
Maverick Wind Project, LLC 63494 2025 ['OP'] unknown unresolved
Canadian Breaks LLC 63030 2025 ['OP'] unknown unresolved
Fourmile Ridge 58904 2025 ['OP'] unknown unresolved
Stahl Wind Energy 56409 2025 ['OP'] unknown unresolved
Kibby Wind Facility 56829 2025 ['OP', 'OP'] unknown unresolved
Buffalo Mountain Energy Center 56493 2025 ['RE'] unknown unresolved
Coyote Ridge 61047 2025 ['OP'] unknown unresolved
Headwaters Wind Farm LLC 58416 2025 ['OP'] unknown unresolved
Rocksprings 60217 2025 ['OP'] unknown unresolved
Fox Island Wind LLC 57354 2025 ['OP'] unknown unresolved
Casselman Wind Power Project 56369 2025 ['OP'] unknown unresolved
Kingdom Community Wind 57979 2025 ['OP'] unknown unresolved
OU Spirit Wind Farm 57286 2025 ['OP'] unknown unresolved
Neosho Ridge Wind Energy Center 62481 2025 ['OP'] unknown unresolved
South Fork Wind Farm 58691 2025 ['OP'] unknown unresolved
Harvest 56635 2025 ['OP'] unknown unresolved
Astra Wind Farm 60856 2025 ['OP'] unknown unresolved
Prairie Hill Wind Project 63100 2025 ['OP'] unknown unresolved
Bull Hill Wind Project 57083 2025 ['OP'] unknown unresolved
Loess Hills 56538 2025 ['OP'] unknown unresolved
Big Turtle Wind Farm LLC 58891 2025 ['OP'] unknown unresolved
Prevailing Wind Park 62247 2025 ['OP'] unknown unresolved
WED Coventry 5 59313 2025 ['OP'] unknown unresolved
Wildcat Ranch Wind Project 61674 2025 ['OP'] unknown unresolved
Marshall Wind 5 LLC 56827 2025 ['OP'] unknown unresolved
Horse Hollow Wind Energy Center 56291 2025 ['OP', 'OP', 'OP'] unknown unresolved
Aurora Wind Project 63258 2025 ['OP'] unknown unresolved
Dermott Wind 60902 2025 ['OP'] unknown unresolved
Buffalo Dunes Wind Project 58474 2025 ['OP'] unknown unresolved
Wagon Wheel Wind 69224 2025 ['OP'] unknown unresolved
Bisson Windfarm LLC 56201 2025 ['OP'] unknown unresolved
Ryegrass Windfarm 57427 2025 ['OP'] unknown unresolved
Michelangelo Wind 4 LLC 59232 2025 ['OP'] unknown unresolved
Two Dot Wind Broadview East LLC 64332 2025 ['OP'] unknown unresolved
Casa Mesa Wind Energy Center Hybrid 61925 2025 ['OP'] unknown unresolved
Spion Kop Wind Farm 58218 2025 ['OP'] unknown unresolved
Lakeswind Power Partners 58836 2025 ['OP'] unknown unresolved
Cuming County Renewables LLC 63393 2025 ['OP'] unknown unresolved
Minnesota Breeze LLC 56587 2025 ['OP'] unknown unresolved
Marshall Wind 6 LLC 56828 2025 ['OP'] unknown unresolved
Tehachapi Wind Resource II 54909 2025 ['OP', 'OP', 'OP'] unknown unresolved
Stella Wind Farm 59063 2025 ['OP'] unknown unresolved
Caney River Wind Project 57858 2025 ['OP'] unknown unresolved
Welcome Wind Turbine 57248 2025 ['OA'] unknown unresolved
Palo Duro Wind 59475 2025 ['OP'] unknown unresolved
Gunsight Mountain Wind Energy LLC 56776 2025 ['OP'] unknown unresolved
Coram Energy LLC 54299 2025 ['RE'] unknown unresolved
Coram Energy LLC 54299 2025 ['OP'] unknown unresolved
Diversion Wind Energy LLC 67601 2025 ['OP', 'OP'] unknown unresolved
Buffalo Gap 3 Wind Farm 56638 2025 ['OP'] unknown unresolved
Princeton Wind Farm 7501 2025 ['RE'] unknown unresolved
Princeton Wind Farm 7501 2025 ['OP'] unknown unresolved
Dinosaur Point 10005 2025 ['OS'] unknown unresolved
Pomeroy Wind Farm 56501 2025 ['OP', 'OP', 'OP', 'OP'] unknown unresolved
Electra Wind Farm 60338 2025 ['OP'] unknown unresolved
Flat Ridge 2 Wind Energy LLC 57787 2025 ['OP'] unknown unresolved
WED Coventry 1 59301 2025 ['OP'] unknown unresolved
Foundation Wal-Mart Red Bluff 58105 2025 ['OP'] unknown unresolved
Twin Ridges Wind Farm 57998 2025 ['OP'] unknown unresolved
Groton Wind LLC 58141 2025 ['OP'] unknown unresolved
Haystack Wind Project, LLC 64139 2025 ['OP'] unknown unresolved
Prospector Windfarm (Burnt River) 59493 2025 ['OP'] unknown unresolved
Notrees Windpower Hybrid 56961 2025 ['OP', 'OP'] unknown unresolved
Arkwright Summit Wind Farm LLC 61673 2025 ['OP'] unknown unresolved
Wildhorse Mountain Wind Facility 61866 2025 ['OP'] unknown unresolved
Babbitt Ranch Energy Center 66110 2025 ['OP'] unknown unresolved
Whirlpool Corp-Greenville Wind Farm 61660 2025 ['OP', 'OP', 'OP'] unknown unresolved
Pinyon Pine I 57834 2025 ['OP'] unknown unresolved
Mountain Home 56636 2025 ['OP'] unknown unresolved
Cabazon Wind Partners 56011 2025 ['OP'] unknown unresolved
Crescent Wind Park 63686 2025 ['OP'] unknown unresolved
Cassia Wind 56934 2025 ['OP'] unknown unresolved
Boeve Windfarm LLC 56209 2025 ['OP'] unknown unresolved
Windstar 1 57774 2025 ['OP'] unknown unresolved
Blue Canyon Windpower II 56335 2025 ['OP'] unknown unresolved
El Algodon Alto Wind Farm, LLC 64591 2025 ['OP'] unknown unresolved
Ironwood Wind 57639 2025 ['OP'] unknown unresolved
Chickasaw Wind Farm 66668 2025 ['OP'] unknown unresolved
Wolverine 57631 2025 ['OP'] unknown unresolved
Forward Wind Energy Center 56942 2025 ['OP', 'OP'] unknown unresolved
Agriwind 56408 2025 ['OP'] unknown unresolved
Rippey Wind Farm 57830 2025 ['OP'] unknown unresolved
Minco Wind IV LLC 61836 2025 ['OP'] unknown unresolved
Lindahl Wind Project LLC 59684 2025 ['OP'] unknown unresolved
Brazos Wind Farm 56111 2025 ['OP'] unknown unresolved
McFadden Ridge 57039 2025 ['OP'] unknown unresolved
Peetz Table Wind Energy 56563 2025 ['OP'] unknown unresolved
Kahuku Wind Power LLC 57087 2025 ['OP'] unknown unresolved
Hardscrabble Wind Power LLC 57287 2025 ['OP'] unknown unresolved
Sweetwater Wind 4 LLC 56337 2025 ['OP'] unknown unresolved
Buffalo Gap Wind Farm 56240 2025 ['OP'] unknown unresolved
Blue Breezes LLC 56580 2025 ['OP'] unknown unresolved
Horseshoe Bend Wind LLC 57550 2025 ['OP'] unknown unresolved
Power County Wind Park South 57760 2025 ['OP'] unknown unresolved
Alta Wind Energy Center IV 57293 2025 ['OP'] unknown unresolved
Canton Mountain Wind 58620 2025 ['OP'] unknown unresolved
GE-Lubbock 62642 2025 ['OP', 'OP', 'OP'] unknown unresolved
Milford Wind Corridor Stage II LLC 57107 2025 ['OP'] unknown unresolved
Pleasant Valley Wind Farm 59201 2025 ['OP'] unknown unresolved
Four Mile Canyon Windfarm LLC 56970 2025 ['OP'] unknown unresolved
Cheyenne Ridge Wind Farm 62952 2025 ['OP'] unknown unresolved
August Wind Farm 61644 2025 ['OP'] unknown unresolved
Michigan Wind 1 56416 2025 ['OP'] unknown unresolved
Coram Tehachapi 54750 2025 ['OP'] unknown unresolved
Sherbino II 57415 2025 ['OP'] unknown unresolved
Chopin Wind LLC 59076 2025 ['OP'] unknown unresolved
Limon III Wind LLC 59083 2025 ['OP'] unknown unresolved
Bruennings Breeze Wind Farm 59066 2025 ['OP'] unknown unresolved
Buckeye Wind Energy Center 58767 2025 ['CN', 'CN'] unknown unresolved
Buckeye Wind Energy Center 58767 2025 ['OP'] unknown unresolved
Brookfield 58719 2025 ['OP'] unknown unresolved
Sweetwater Wind 2 LLC 56212 2025 ['OP'] unknown unresolved
Wiota 58461 2025 ['OP'] unknown unresolved
Whitetail 58021 2025 ['OP'] unknown unresolved
Locust Ridge II LLC 56770 2025 ['OP'] unknown unresolved
Oliver Wind III LLC 60905 2025 ['OP'] unknown unresolved
Majestic 1 Wind Farm 56648 2025 ['OP'] unknown unresolved
Kay Wind LLC 59460 2025 ['OP'] unknown unresolved
WED Green Hill LLC 62106 2025 ['OP'] unknown unresolved
South Trent Wind Farm 56649 2025 ['OP'] unknown unresolved
Little Pringle I Wind Farm 57263 2025 ['RE'] unknown unresolved
Tri-Tip Wind (9) LLC 56837 2025 ['OP'] unknown unresolved
Blackstone Wind Farm II LLC 57113 2025 ['OP'] unknown unresolved
Sandy Ridge Wind Farm 57285 2025 ['OP'] unknown unresolved
Fair Wind 59147 2025 ['OP'] unknown unresolved
Santa Rita East 62038 2025 ['OP'] unknown unresolved
Prosperity Wind 68193 2025 ['OP'] unknown unresolved
Oasis Wind 56302 2025 ['OP'] unknown unresolved
Shooting Star 58018 2025 ['OP'] unknown unresolved
Winters Spawn LLC 55567 2025 ['OP'] unknown unresolved
Mountain Wind Power LLC 56752 2025 ['OP'] unknown unresolved
Breckinridge Wind Project LLC 58994 2025 ['OP'] unknown unresolved
Post Rock Wind Power Project LLC 57678 2025 ['OP'] unknown unresolved
Slate Creek Wind Project LLC 59837 2025 ['OP'] unknown unresolved
Aragonne Wind LLC 56336 2025 ['OP', 'OP'] unknown unresolved
Gratiot Farms Wind Project 63687 2025 ['OP'] unknown unresolved
Charles City Wind Farm 56677 2025 ['OP'] unknown unresolved
Locust Ridge 56470 2025 ['OP'] unknown unresolved
Mill Run Windpower LLC 55805 2025 ['OP'] unknown unresolved
Biglow Canyon Wind Farm 56485 2025 ['OP', 'OP', 'OP'] unknown unresolved
Soldier Creek Wind 64309 2025 ['OP'] unknown unresolved
Rolling Hills 56842 2025 ['OP'] unknown unresolved
Goodnoe Hills 56666 2025 ['OP'] unknown unresolved
TransAlta Wyoming Wind 56093 2025 ['OP'] unknown unresolved
Madison Windpower LLC 55769 2025 ['OP'] unknown unresolved
Fossil Gulch 56308 2025 ['OP'] unknown unresolved
Victory Wind Farm 56379 2025 ['OP'] unknown unresolved
Los Vientos Wind 1A 57751 2025 ['OP'] unknown unresolved
Plum Creek Wind Project (NE) 62711 2025 ['OP'] unknown unresolved
Laurel Mountain Hybrid 57447 2025 ['OP'] unknown unresolved
Frontier Windpower 60218 2025 ['OP'] unknown unresolved
Alta Wind X 58394 2025 ['OP'] unknown unresolved
Valentine Wind LLC 59736 2025 ['OP'] unknown unresolved
Crocker Wind Farm 60505 2025 ['OP'] unknown unresolved
Cold Springs Windfarm 57431 2025 ['OP'] unknown unresolved
Top of the World Windpower Project 57327 2025 ['OP'] unknown unresolved
Reloj del Sol Wind Farm 62207 2025 ['OP'] unknown unresolved
Harpster Wind 60126 2025 ['OP'] unknown unresolved
Borderlands Wind, LLC 64638 2025 ['OP'] unknown unresolved
Loraine Windpark Project LLC 57303 2025 ['OP', 'OP'] unknown unresolved
Optimum Wind 5 LLC 59223 2025 ['OP'] unknown unresolved
Wagon Trail LLC 56974 2025 ['OP'] unknown unresolved
Panorama Wind, LLC 64872 2025 ['OP'] unknown unresolved
Difwind Farms Ltd VI 54686 2025 ['OP'] unknown unresolved
Foundation SaIinas Valley State Prison 61444 2025 ['OP'] unknown unresolved
Kirkwood Wind Turbine 59735 2025 ['RE'] unknown unresolved
Panther Creek Wind Farm I 56920 2025 ['OP'] unknown unresolved
Difwind Farms Ltd II 54682 2025 ['RE'] unknown unresolved
Rolling Hills Wind Farm 57501 2025 ['OP'] unknown unresolved
Priddy Wind Project 64165 2025 ['OP'] unknown unresolved
Durbin Creek Windfarm (Burnt River) 59492 2025 ['OP'] unknown unresolved
Pike County Wind Power 56376 2025 ['RE'] unknown unresolved
Foundation Mann Packing 61443 2025 ['OP'] unknown unresolved
Helena Wind 63738 2025 ['OP'] unknown unresolved
Osceola Windpower LLC 56645 2025 ['OP'] unknown unresolved
Roeder Family Wind Farm LLC 58089 2025 ['OP'] unknown unresolved
Mt Wachusett Community College 58025 2025 ['OP', 'OP'] unknown unresolved
Roth Rock Wind Farm LLC 57239 2025 ['OP'] unknown unresolved
Centennial Wind Farm 56380 2025 ['OP'] unknown unresolved
Anderson Wind I 58939 2025 ['OP'] unknown unresolved
Flat Water Wind Farm LLC 57283 2025 ['CN'] unknown unresolved
Flat Water Wind Farm LLC 57283 2025 ['OP'] unknown unresolved
Moulton Wind Power 55981 2025 ['RE'] unknown unresolved
Jayhawk Wind Energy Center 65129 2025 ['OP'] unknown unresolved
Manzana Wind LLC 57484 2025 ['OP'] unknown unresolved
Vansycle II Wind Energy Center 58324 2025 ['OP'] unknown unresolved
Farmers City Wind LLC 56767 2025 ['OP'] unknown unresolved
Tucannon River Wind Farm 58571 2025 ['OP'] unknown unresolved
Kingman 1 57775 2025 ['OP'] unknown unresolved
Dakota Range Wind 68318 2025 ['OP'] unknown unresolved
Viking Wind Partners 56153 2025 ['RE'] unknown unresolved
Adams Wind Generations LLC 57375 2025 ['OP'] unknown unresolved
Hammett Hill Windfarm 57428 2025 ['OP'] unknown unresolved
Rock County Wind Fuel, LLC 63460 2025 ['OP'] unknown unresolved
Shady Oaks Wind Farm 57964 2025 ['OP'] unknown unresolved
High Winds LLC 56075 2025 ['OP', 'OP'] unknown unresolved
Difwind Farms Ltd V 54685 2025 ['RE'] unknown unresolved
Foundation IE 57792 2025 ['OP'] unknown unresolved
Origin Wind 58938 2025 ['OP'] unknown unresolved
Logan Wind Energy 56613 2025 ['OP'] unknown unresolved
Macho Springs Power I 57947 2025 ['OP'] unknown unresolved
Holiday Hill Community Wind 62897 2025 ['OP'] unknown unresolved
Foote Creek I 55607 2025 ['RE'] unknown unresolved
Duran Mesa LLC 64065 2025 ['OP'] unknown unresolved
Pacific Wind LLC 57757 2025 ['OP'] unknown unresolved
Power County Wind Park North 57761 2025 ['OP'] unknown unresolved
Meadow Lake Wind Farm III LLC 57115 2025 ['OP'] unknown unresolved
Triple H Wind Project 63103 2025 ['OP'] unknown unresolved
Deuel Harvest Wind Energy LLC 62943 2025 ['OP'] unknown unresolved
Stony Creek Wind Farm NY 58088 2025 ['OP'] unknown unresolved
Gordon Butte Wind LLC 57748 2025 ['OP', 'OP', 'OP', 'OP'] unknown unresolved
King Mountain Wind Ranch 1 55581 2025 ['OP'] unknown unresolved
Julia Hills LLC 55563 2025 ['OP'] unknown unresolved
Atchison County Wind 63574 2025 ['OP'] unknown unresolved
Fontanelle 58457 2025 ['OP'] unknown unresolved
WED Plainfield II LLC 62107 2025 ['OP'] unknown unresolved
KODE Novus I 57516 2025 ['RE'] unknown unresolved
Rail Splitter Wind Farm 56856 2025 ['OP'] unknown unresolved
Glenrock 56841 2025 ['OP', 'OP'] unknown unresolved
Los Vientos V Wind Power 60059 2025 ['OP'] unknown unresolved
Los Vientos Windpower III 59320 2025 ['OP'] unknown unresolved
Hadley Ridge LLC 55573 2025 ['OP'] unknown unresolved
North Hurlburt Wind LLC 57526 2025 ['OP'] unknown unresolved
Golden Acorn Casino 59328 2025 ['OP'] unknown unresolved
Payne's Ferry 57124 2025 ['OP'] unknown unresolved
Town of Otis Wind Energy Project 61775 2025 ['OP'] unknown unresolved
Swauk Wind LLC 58441 2025 ['OP'] unknown unresolved
Cottonwood Wind Energy Center 61407 2025 ['OP'] unknown unresolved
Woodward Mountain II 55795 2025 ['OP'] unknown unresolved
Anheuser-Busch #2 59331 2025 ['OP'] unknown unresolved
Alta Wind Energy Center III 57292 2025 ['OP'] unknown unresolved
Mesquite Creek Wind 59332 2025 ['OP'] unknown unresolved
Sundance Wind Project, LLC 63489 2025 ['OP'] unknown unresolved
Blue Canyon Windpower 56081 2025 ['OP'] unknown unresolved
Flying Cloud Power Partners LLC 56172 2025 ['OP'] unknown unresolved
Pinnacle Wind Force LLC 57595 2025 ['OP'] unknown unresolved
Community Wind South 58045 2025 ['OP'] unknown unresolved
New Mexico Wind Energy Center 56097 2025 ['OP'] unknown unresolved
Conception 56537 2025 ['OP'] unknown unresolved
Leaning Juniper 56360 2025 ['OP'] unknown unresolved
Dunlap 57299 2025 ['OP'] unknown unresolved
Munnsville Wind Farm LLC 56594 2025 ['OP'] unknown unresolved
Central Plains Wind Farm 56818 2025 ['OP'] unknown unresolved
Saratoga Wind Farm 61070 2025 ['OP'] unknown unresolved
Hay Canyon Wind Power LLC 56790 2025 ['OP'] unknown unresolved
Ringer Hill Wind Farm LLC 60329 2025 ['OP'] unknown unresolved
PaTu Wind Farm LLC 57578 2025 ['OP'] unknown unresolved
Uilk Wind LLC 57351 2025 ['OP', 'OP', 'OP'] unknown unresolved
Bent Tree Wind Farm Phase 1 57198 2025 ['OP'] unknown unresolved
Mariah del Norte 59005 2025 ['OP'] unknown unresolved
Beebe 1B 58908 2025 ['OP'] unknown unresolved
Wildcat Wind Farm I LLC 57862 2025 ['OP'] unknown unresolved
Pisgah Mountain Wind 60404 2025 ['OP'] unknown unresolved
Deerfield Wind LLC 61039 2025 ['OP'] unknown unresolved
PPL Frey Farm Landfill Wind 57182 2025 ['OP'] unknown unresolved
Spinning Spur Wind III 58775 2025 ['OP'] unknown unresolved
Desert Meadow Windfarm 57430 2025 ['OP'] unknown unresolved
Prairie Switch Wind LLC 66123 2025 ['OP'] unknown unresolved
Butter Creek Power LLC 56967 2025 ['OP'] unknown unresolved
Delta Wind Farm 58511 2025 ['OP', 'OP', 'OP'] unknown unresolved
Glen Ullin Energy Center 62938 2025 ['OP'] unknown unresolved
Los Vientos Windpower IV 59321 2025 ['OP'] unknown unresolved
Kelly Creek Wind Project 60587 2025 ['OP'] unknown unresolved
University of Delaware Wind Turbine 57176 2025 ['OP'] unknown unresolved
Whitney Hill Wind Power LLC 62606 2025 ['OP'] unknown unresolved
Young Wind 65763 2025 ['OP'] unknown unresolved
Los Vientos Wind 1B 57752 2025 ['OP'] unknown unresolved
Twin Buttes II Wind 61040 2025 ['OP'] unknown unresolved
Radfords Run Wind Farm 59061 2025 ['OP'] unknown unresolved
Meadow Lake Wind Farm IV 57177 2025 ['OP'] unknown unresolved
Canadian Hills Wind 57987 2025 ['OP'] unknown unresolved
Mountain View IV 57459 2025 ['OP'] unknown unresolved
Rugby Wind Power Project 57097 2025 ['OP'] unknown unresolved
Shiloh Wind Project 2 LLC 56874 2025 ['OP'] unknown unresolved
Hancock Wind Plant 58686 2025 ['OP'] unknown unresolved
Appaloosa Run Wind 65335 2025 ['OP'] unknown unresolved
Two Dot Wind Farm 59003 2025 ['OP'] unknown unresolved
Marshall Wind 2 LLC 56824 2025 ['OP'] unknown unresolved
Bobcat Bluff Wind Project LLC 57974 2025 ['OP'] unknown unresolved
Kingfisher Wind LLC 58902 2025 ['OP'] unknown unresolved
Martin Marietta Wind Project 66261 2025 ['OP', 'OP', 'OP'] unknown unresolved
Brule County Wind 61746 2025 ['OP'] unknown unresolved
Oso Grande Wind Farm 63502 2025 ['OP', 'OP'] unknown unresolved
Big Top LLC 56968 2025 ['OP'] unknown unresolved
Rock Creek Wind Project 60655 2025 ['OP'] unknown unresolved
Green Energy Machine 60911 2025 ['OP'] unknown unresolved
Scituate Wind 59724 2025 ['OP'] unknown unresolved
Seymour Hills Wind Project LLC 62227 2025 ['OP'] unknown unresolved
Grande Prairie Wind Farm 58695 2025 ['OP'] unknown unresolved
GSG LLC 56450 2025 ['OP'] unknown unresolved
Sweetwater Wind 1 LLC 56211 2025 ['OP'] unknown unresolved
Lake Region Community Hybrid LLC 62442 2025 ['OP'] unknown unresolved
Eva Creek Wind 57935 2025 ['OP'] unknown unresolved
Old Trail Wind Farm 56614 2025 ['OP'] unknown unresolved
White Creek Wind Farm 56487 2025 ['OP'] unknown unresolved
Kaheawa Pastures Wind Farm Hybrid 56449 2025 ['OP'] unknown unresolved
Palmer's Creek Wind Farm LLC 62291 2025 ['OP'] unknown unresolved
Adams Wind 59637 2025 ['OP', 'OP', 'OP', 'OP'] unknown unresolved
Pratt Wind LLC 61957 2025 ['OP'] unknown unresolved
Florence Hills LLC 55574 2025 ['OP'] unknown unresolved
Haviland Plastic Products 58220 2025 ['OP', 'OP', 'OP'] unknown unresolved
Winnebago Wind Power Project 56764 2025 ['OP'] unknown unresolved
White Mesa Wind 64710 2025 ['OP'] unknown unresolved
Bison 4 Wind Energy Center 58872 2025 ['OP'] unknown unresolved
Bulldog 57632 2025 ['OP'] unknown unresolved
Capricorn Ridge Wind LLC 56763 2025 ['OP', 'OP', 'OP', 'OP'] unknown unresolved
Ida Grove Wind 60342 2025 ['CN', 'CN'] unknown unresolved
Ida Grove Wind 60342 2025 ['OP', 'OP', 'OP', 'OP'] unknown unresolved
Cloud County Wind Farm 56784 2025 ['OP', 'OP'] unknown unresolved
Adams Wind Farm 56307 2025 ['OP', 'OP'] unknown unresolved
Cedar Point Wind 57315 2025 ['OP'] unknown unresolved
Paulding Wind Farm II 57620 2025 ['OP'] unknown unresolved
Foundation AB 57791 2025 ['OP'] unknown unresolved
Kumeyaay Wind 56295 2025 ['OP'] unknown unresolved
Rattlesnake Power LLC 60743 2025 ['OP'] unknown unresolved
Prairie Breeze 58322 2025 ['OP'] unknown unresolved
Midway Wind LLC 61776 2025 ['OP'] unknown unresolved
Foundation NWNA 58114 2025 ['OP', 'OP', 'OP'] unknown unresolved
Butler Ridge 56647 2025 ['OP'] unknown unresolved
Steel Winds II 57078 2025 ['OP'] unknown unresolved
Red Hills Wind Project LLC 56804 2025 ['OP'] unknown unresolved
Langdon Wind II LLC 56912 2025 ['OP'] unknown unresolved
Bishop Hill II Wind Farm 58111 2025 ['OP'] unknown unresolved
Sand Bluff Wind Farm 56479 2025 ['OP'] unknown unresolved
South Plains II 60087 2025 ['OP'] unknown unresolved
Prairie Winds SD1 56608 2025 ['OP', 'OP', 'OP'] unknown unresolved
Crystal Lake 3 LLC 57468 2025 ['OP'] unknown unresolved
Optimum Wind 6 LLC 59224 2025 ['OP'] unknown unresolved
FPL Energy Montezuma Winds LLC 57201 2025 ['OP'] unknown unresolved
Maple Ridge Wind Farm 56290 2025 ['OP', 'OP', 'OP', 'OP'] unknown unresolved
South Dakota Wind Energy Cente 56092 2025 ['OP'] unknown unresolved
Optimum Wind 7 LLC 59225 2025 ['OP'] unknown unresolved
Big Timber Wind Farm 61155 2025 ['OP'] unknown unresolved
McAdoo Wind Energy LLC 56773 2025 ['OP'] unknown unresolved
Limon Wind II 58127 2025 ['OP'] unknown unresolved
Blue Cloud Wind Energy LLC 60270 2025 ['OP'] unknown unresolved
Silver Star I Wind Power Project 56771 2025 ['OP'] unknown unresolved
Bluff Point Wind Facility 61303 2025 ['OP'] unknown unresolved
Apple Blossom Wind Farm 58690 2025 ['OP'] unknown unresolved
Shenandoah Hills Wind Farm 68872 2025 ['OP'] unknown unresolved
Latigo Wind Park 59965 2025 ['OP'] unknown unresolved
Saddleback Ridge Wind Farm 58608 2025 ['OP', 'OP'] unknown unresolved
MA Military Reservation Wind Project 57253 2025 ['OP', 'OP', 'OP'] unknown unresolved
Colbeck's Corner LLC 59068 2025 ['OP'] unknown unresolved
Stillwater Wind LLC 61858 2025 ['OP'] unknown unresolved
East Winds Project 50820 2025 ['OP'] unknown unresolved
Storm Lake II 55287 2025 ['OP'] unknown unresolved
Smoky Hills Wind Project Phase I 56488 2025 ['OP'] unknown unresolved
Lincoln Heights II 63433 2025 ['OP'] unknown unresolved
Fairmont Wind 56415 2025 ['OP', 'OP', 'OP', 'OP'] unknown unresolved
Weatherford Wind Energy Center 56273 2025 ['OP', 'OP'] unknown unresolved
Thousand Springs Wind Park 56442 2025 ['OP'] unknown unresolved
Magic Valley Wind Farm I LLC 57802 2025 ['OP'] unknown unresolved
Walnut Wind Farm 56811 2025 ['OP'] unknown unresolved
Meadow Lake Wind Farm II LLC 57112 2025 ['OP'] unknown unresolved
Prairie Queen Wind Farm 62488 2025 ['OP'] unknown unresolved
NLMU Wind 58414 2025 ['OP'] unknown unresolved
Upstream Wind Energy LLC 61784 2025 ['OP'] unknown unresolved
Streator Cayuga Ridge South 57094 2025 ['OP'] unknown unresolved
Crowned Ridge Wind Energy Center 60503 2025 ['OP'] unknown unresolved
Keechi Wind 58838 2025 ['OP'] unknown unresolved
Prairie Winds ND1 56607 2025 ['OP'] unknown unresolved
Pocahontas Prairie Wind Farm 57976 2025 ['OP'] unknown unresolved
City of Soledad Water Reclamation 59329 2025 ['OP'] unknown unresolved
Musselshell Wind Project Two LLC 57965 2025 ['OP'] unknown unresolved
TB Flats 62516 2025 ['OP'] unknown unresolved
Callahan Divide Wind Energy Center 56270 2025 ['OP'] unknown unresolved
Grandview Wind Farm LLC 58596 2025 ['OP'] unknown unresolved
NaturEner Glacier Wind Energy 2 57050 2025 ['OP'] unknown unresolved
Vestas Towers America Inc. 57643 2025 ['CN'] unknown unresolved
Vestas Towers America Inc. 57643 2025 ['OP'] unknown unresolved
North Allegheny Windpower Project 56651 2025 ['OP'] unknown unresolved
Logans Gap Wind LLC 59442 2025 ['OP'] unknown unresolved
Desert Wind Farm LLC 59968 2025 ['OP'] unknown unresolved
Moraine II Wind LLC 56794 2025 ['OP'] unknown unresolved
Kaheawa Wind Power II LLC 57082 2025 ['OP'] unknown unresolved
Klondike Wind Power 55871 2025 ['OP'] unknown unresolved
Lucky Wind 56412 2025 ['OP'] unknown unresolved
Great Pathfinder Wind 65715 2025 ['OP'] unknown unresolved
Bowling Green Wind 56226 2025 ['RE', 'RE', 'RE', 'RE'] unknown unresolved
Cimarron Bend Wind Project I LLC 60687 2025 ['OP'] unknown unresolved
Day County Wind LLC 57194 2025 ['OP'] unknown unresolved
Waverly Community Wind Project 57214 2025 ['OP', 'OP', 'OP'] unknown unresolved
Predominant models and representative heights are partial inventories, not exact fleets.
Dated EIA generator observations by reporting year: {2025: {'OP': 1300, 'RE': 62, 'CN': 20, 'OS': 8, 'OA': 2}}
EPD lifetime scenarios: separate model, location, exposure and net-to-grid boundary
GWH182-7.2MW Exemplary Ras Ghareb City, Egypt scenario 25 years 852570.86 MWh modeled one turbine; net electricity delivered to grid goldwind_epditaly0508
GWH175-7.8MW Exemplary Miombo,Tanzania scenario 20 years 820705.92 MWh modeled one turbine; net electricity delivered to grid goldwind_epditaly0852
GWH175-7.8MW Exemplary Miombo,Tanzania scenario 25 years 1025882.4 MWh modeled one turbine; net electricity delivered to grid goldwind_epditaly0852
GWH170-7.2MW Exemplary Miombo,Tanzania scenario 20 years 774216.96 MWh modeled one turbine; net electricity delivered to grid goldwind_epditaly0852
GWH170-7.2MW Exemplary Miombo,Tanzania scenario 25 years 967771.2 MWh modeled one turbine; net electricity delivered to grid goldwind_epditaly0852
GWH182-7.5MW Exemplary Ras Ghareb City, Egypt scenario 25 years 876662.4 MWh modeled one turbine; net electricity delivered to grid goldwind_epditaly0508
GWH182-5.3MW Exemplary Ras Ghareb City, Egypt scenario 25 years 728448.76 MWh modeled one turbine; net electricity delivered to grid goldwind_epditaly0508
GWH182-6.2MW Exemplary Ras Ghareb City, Egypt scenario 25 years 797814.25 MWh modeled one turbine; net electricity delivered to grid goldwind_epditaly0508
GWH182-8.0MW Exemplary Miombo,Tanzania scenario 20 years 820874.88 MWh modeled one turbine; net electricity delivered to grid goldwind_epditaly0852
GWH182-8.0MW Exemplary Miombo,Tanzania scenario 25 years 1026093.6 MWh modeled one turbine; net electricity delivered to grid goldwind_epditaly0852
No scenario total, capacity factor, operating project or comparable curve is inferred.
BOE decision scope: wind lifecycle and capacity boundaries remain separate
Herrera de los Navarros decision target solar decision date 2026-10-19 wind status unknown status date 2026-10-19 installed MW 35.0 planned MW None aggregation unresolved quarantined fields []
Pinta y Guindalera decision target auxiliary decision date 2026-10-18 wind status permitted status date 2024-01-17 installed MW None planned MW 103.5 aggregation unresolved quarantined fields []
Valiente II decision target wind decision date 2026-10-01 wind status permitted status date 2024-07-05 installed MW None planned MW 88.4 aggregation unresolved quarantined fields []
Torre Madrina extension decision target wind decision date 2026-10-02 wind status announced status date 2026-10-02 installed MW None planned MW 11 aggregation unresolved quarantined fields []
Coll del Moro extension decision target wind decision date 2026-10-02 wind status announced status date 2026-10-02 installed MW None planned MW 11 aggregation unresolved quarantined fields []
Nordés decision target wind decision date 2026-09-25 wind status cancelled status date 2026-09-25 installed MW None planned MW 67.2 aggregation unresolved quarantined fields []
Valentina wind hybrid decision target wind decision date 2026-10-02 wind status cancelled status date 2026-10-02 installed MW None planned MW 90 aggregation unresolved quarantined fields []
Taraguilla decision target wind decision date 2026-07-01 wind status cancelled status date 2026-07-01 installed MW None planned MW 62.7 aggregation unresolved quarantined fields ['connection_voltage_kv', 'substation']
Ferromolín decision target wind decision date 2026-09-21 wind status announced status date 2026-09-21 installed MW None planned MW 27 aggregation unresolved quarantined fields []
Las Quinientas wind module decision target wind decision date 2026-10-22 wind status announced status date 2026-10-22 installed MW None planned MW 33.0 aggregation unresolved quarantined fields ['rotor_diameter_m']
Explicit component applications and their conditions (not deployed fleets):
ABB ACS880-77LC-2503A/2328A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
ABB ACS800-67LC-2035/1125-7 → ABB ACS800-104LC-0705-7+E205 Documented internal assembly relation only; no turbine compatibility inferred
ABB ACS800-67LC-2035/1125-7 → ABB ACS800-104LC-0705-7+E205 Documented internal assembly relation only; no turbine compatibility inferred
Vertiv Tech (Mianyang) WF1000-06L0270-CPN-A → Suzlon S144-3.0 / 3.15 MW Only S144-3.0 / 3.15 MW configurations in TC-240121 Rev.2, issued 2024-05-06. Certificate requires maintenance and approved design/quality changes; no current eligibility or deployed-fleet claim.
Bonfiglioli LCVT008 → Bonfiglioli ACU 210-11 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT008 → Bonfiglioli ACU 410-15 (frame 2) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV400A-690 → Bonfiglioli ACU 610-51 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV400A-690 → Bonfiglioli ACU 610-53 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV400A-690 → Bonfiglioli ACU 610-55 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV400A-690 → Bonfiglioli ACU 610-57 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV400A-690 → Bonfiglioli ACU 610-59 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV400A-690 → Bonfiglioli ACU 610-61 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVS006 → Bonfiglioli ACU 210-01 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVS006 → Bonfiglioli ACU 210-03 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVS006 → Bonfiglioli ACU 210-05 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT350AL-525 → Bonfiglioli ACU 510-55 (frame 8) Component pairing only; no wind turbine compatibility
Flender PDFJ 2776 → Venwind Refex Power GWH182-5.3 Only the exact turbine configuration named by this disclosure; listed alternatives are not universal deployed compatibility
Bonfiglioli LCVS008 → Bonfiglioli ACU 210-07 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli BR 4000/16 → Bonfiglioli ACU 410-27 (frame 5) Quantity 1; duty cycle 22% at drive rated power; not turbine compatibility
Bonfiglioli BR 4000/16 → Bonfiglioli ACU 410-29 (frame 5) Quantity 1; duty cycle 18% at drive rated power; not turbine compatibility
Bonfiglioli BR 4000/16 → Bonfiglioli ACU 410-31 (frame 5) Quantity 1; duty cycle 13% at drive rated power; not turbine compatibility
ABB ACS880-87LC-4000A/3800A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
ABB ACS880-87LC-8000A/7600A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
Bonfiglioli LCVT200AL-690 → Bonfiglioli ACU 610-53 (frame 8) Component pairing only; no wind turbine compatibility
ABB ACS880-87LC-5006A/4656A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
Bonfiglioli BR 432/37 → Bonfiglioli ACU 210-11 (frame 1) Quantity 1; duty cycle 29% at drive rated power; not turbine compatibility
Bonfiglioli BR 432/37 → Bonfiglioli ACU 210-13 (frame 2) Quantity 1; duty cycle 20% at drive rated power; not turbine compatibility
Bonfiglioli BR 432/37 → Bonfiglioli ACU 210-15 (frame 2) Quantity 1; duty cycle 14% at drive rated power; not turbine compatibility
Bonfiglioli LCVT160 → Bonfiglioli ACU 410-43 (frame 7) Component pairing only; no wind turbine compatibility
Bonfiglioli BR 1333/12 → Bonfiglioli ACU 210-21 (frame 4) Quantity 1; duty cycle 18% at drive rated power; not turbine compatibility
Bonfiglioli BR 1333/12 → Bonfiglioli ACU 210-22 (frame 4) Quantity 1; duty cycle 14% at drive rated power; not turbine compatibility
Senvion Wind Technology SE 63.7 → Senvion Wind Technology 3.1M130 Explicit Senvion 3.1M130 component disclosure; listed alternatives are not a claim about every deployed turbine
Bonfiglioli BR 2000/32 → Bonfiglioli ACU 410-23 (frame 4) Quantity 1; duty cycle 18% at drive rated power; not turbine compatibility
Bonfiglioli BR 2000/32 → Bonfiglioli ACU 410-25 (frame 4) Quantity 1; duty cycle 13% at drive rated power; not turbine compatibility
Bonfiglioli HLD 110-500/130 → Bonfiglioli ACU 410-37 (frame 6) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/130 → Bonfiglioli ACU 410-39 (frame 6) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT250 → Bonfiglioli ACU 410-49 (frame 7) Component pairing only; no wind turbine compatibility
ABB ACS800-67-0480/0580-7 → ABB ACS800-104-0580-7 Documented internal assembly relation only; no turbine compatibility inferred
ABB ACS800-67-0480/0580-7 → ABB ACS800-104-0580-7 Documented internal assembly relation only; no turbine compatibility inferred
Bonfiglioli LCVT210 → Bonfiglioli ACU 410-47 (frame 7) Component pairing only; no wind turbine compatibility
Jiangsu Delijia Drive Technology WE7000G-01 → Venwind Refex Power GWH182-5.3 Only the exact turbine configuration named by this disclosure; listed alternatives are not universal deployed compatibility
Bonfiglioli BR 667/24 → Bonfiglioli ACU 210-18 (frame 3) Quantity 1; duty cycle 17% at drive rated power; not turbine compatibility
Bonfiglioli BR 667/24 → Bonfiglioli ACU 210-19 (frame 3) Quantity 1; duty cycle 12% at drive rated power; not turbine compatibility
Suzlon SB70 (SB70S1) → Suzlon S144-3.0 / 3.15 MW Only S144-3.0 / 3.15 MW configurations in TC-240121 Rev.2, issued 2024-05-06. Certificate requires maintenance and approved design/quality changes; no current eligibility or deployed-fleet claim.
Bonfiglioli LCVT215AL-525 → Bonfiglioli ACU 510-51 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT280AL-525 → Bonfiglioli ACU 510-53 (frame 8) Component pairing only; no wind turbine compatibility
ABB ACS800-67-0480/1160-7 → ABB ACS800-104-0580-7 Documented internal assembly relation only; no turbine compatibility inferred
ABB ACS800-67-0480/1160-7 → ABB ACS800-104-1160-7 Documented internal assembly relation only; no turbine compatibility inferred
Bonfiglioli LCVT015 → Bonfiglioli ACU 210-15 (frame 2) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT015 → Bonfiglioli ACU 410-19 (frame 3) Component pairing only; no wind turbine compatibility
Bonfiglioli BR 8000/7 → Bonfiglioli ACU 410-33 (frame 6) Quantity 1; duty cycle 22% at drive rated power; not turbine compatibility
Bonfiglioli BR 8000/7 → Bonfiglioli ACU 410-35 (frame 6) Quantity 1; duty cycle 18% at drive rated power; not turbine compatibility
Bonfiglioli BR 8000/7 → Bonfiglioli ACU 410-37 (frame 6) Quantity 1; duty cycle 15% at drive rated power; not turbine compatibility
Bonfiglioli BR 8000/7 → Bonfiglioli ACU 410-39 (frame 6) Quantity 1; duty cycle 12% at drive rated power; not turbine compatibility
Bonfiglioli BR 8000/7 → Bonfiglioli ACU 410-43 (frame 7) Quantity 1; duty cycle 11% at drive rated power; not turbine compatibility
Bonfiglioli BR 8000/7 → Bonfiglioli ACU 410-45 (frame 7) Quantity 1; duty cycle 9% at drive rated power; not turbine compatibility
Bonfiglioli BR 8000/7 → Bonfiglioli ACU 410-47 (frame 7) Quantity 2; duty cycle 15% at drive rated power; not turbine compatibility
Bonfiglioli BR 8000/7 → Bonfiglioli ACU 410-49 (frame 7) Quantity 2; duty cycle 12% at drive rated power; not turbine compatibility
Eickhoff Wind Power EBN-5715 → Adani New Industries MWL-160-5.2MW Explicit MWL160-5.2MW component disclosure; listed alternatives are not a claim about every deployed turbine
Eickhoff Wind Power EBN-5715 → Adani New Industries MWL-160-5.2MW HYT-140 m Explicit MWL-160-5.2MW HYT-140m component disclosure; listed alternatives are not a claim about every deployed turbine
Bonfiglioli LCVT018 → Bonfiglioli ACU 210-18 (frame 3) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT018 → Bonfiglioli ACU 410-21 (frame 3) Component pairing only; no wind turbine compatibility
Senvion Wind Technology ReT78.5 → Senvion Wind Technology 4.2M160 Only the exact turbine configuration named by this disclosure; listed alternatives are not universal deployed compatibility
Bonfiglioli LCVT034 → Bonfiglioli ACU 210-21 (frame 4) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT034 → Bonfiglioli ACU 210-22 (frame 4) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT034 → Bonfiglioli ACU 410-25 (frame 4) Component pairing only; no wind turbine compatibility
Bonfiglioli BR 160/100 → Bonfiglioli ACU 210-01 (frame 1) Quantity 1; duty cycle 64% at drive rated power; not turbine compatibility
Bonfiglioli BR 160/100 → Bonfiglioli ACU 210-03 (frame 1) Quantity 1; duty cycle 43% at drive rated power; not turbine compatibility
Bonfiglioli BR 160/100 → Bonfiglioli ACU 210-05 (frame 1) Quantity 1; duty cycle 29% at drive rated power; not turbine compatibility
Bonfiglioli BR 160/100 → Bonfiglioli ACU 210-07 (frame 1) Quantity 1; duty cycle 21% at drive rated power; not turbine compatibility
Bonfiglioli BR 160/100 → Bonfiglioli ACU 210-09 (frame 1) Quantity 1; duty cycle 15% at drive rated power; not turbine compatibility
Siemens India 1LG8 456-4 → Pioneer Wincon Energy Systems 750/57 PW28 IIIA Only the exact configuration in this manufacturer disclosure; Pioneer750/57 limited to90m hub; no deployed fleet or other mode inference
ABB ACS880-87LC-4000A/4134A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
Bonfiglioli LCVT160AL-690 → Bonfiglioli ACU 610-51 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli BR 1330/48 → Bonfiglioli ACU 410-19 (frame 3) Quantity 1; duty cycle 24% at drive rated power; not turbine compatibility
Bonfiglioli BR 1330/48 → Bonfiglioli ACU 410-21 (frame 3) Quantity 1; duty cycle 18% at drive rated power; not turbine compatibility
Bonfiglioli BR 1330/48 → Bonfiglioli ACU 410-22 (frame 3) Quantity 1; duty cycle 14% at drive rated power; not turbine compatibility
Bonfiglioli HLD 110-500/180 → Bonfiglioli ACU 410-43 (frame 7) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/180 → Bonfiglioli ACU 410-45 (frame 7) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT025 → Bonfiglioli ACU 210-19 (frame 3) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT025 → Bonfiglioli ACU 410-22 (frame 3) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/100 → Bonfiglioli ACU 410-33 (frame 6) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/100 → Bonfiglioli ACU 410-35 (frame 6) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/16 → Bonfiglioli ACU 210-13 (frame 2) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/16 → Bonfiglioli ACU 210-15 (frame 2) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/16 → Bonfiglioli ACU 410-18 (frame 2) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/16 → Bonfiglioli ACU 410-19 (frame 3) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/16 → Bonfiglioli ACU 410-21 (frame 3) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV018B → Bonfiglioli ACU 410-19 (frame 3) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV018B → Bonfiglioli ACU 410-21 (frame 3) Component pairing only; no wind turbine compatibility
Envision Energy India EN76.5AV2 → Envision Energy India EN-156/3.3 Explicit EN-156/3.3 (LM76.5 P and EN 76.5 A V2) component disclosure; listed alternatives are not a claim about every deployed turbine
Bonfiglioli LCVT180 → Bonfiglioli ACU 410-45 (frame 7) Component pairing only; no wind turbine compatibility
NGC SMG282CDT175-0136 → Adani New Industries WD164-3300 Explicit WD164-3300 component disclosure; listed alternatives are not a claim about every deployed turbine
Bonfiglioli LCVT410AL-690 → Bonfiglioli ACU 610-61 (frame 8) Component pairing only; no wind turbine compatibility
ABB ACS880-77LC-3372A/3136A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
Flender PDAJ3738 → Adani New Industries MWL-160-5.2MW Explicit MWL160-5.2MW component disclosure; listed alternatives are not a claim about every deployed turbine
Bergey Windpower Company Excel 15 → Bergey Windpower Company Powersync 25 EXCEL15 with Powersync25 grid intertie inverter; no other inverter compatibility inferred
Dalian Huarui Special Transmission Equipment CWTG3300/145-110-50 → Inox Wind DF/3000/145 Explicit INOX DF/3000/145 3.0 MW Power Booster Mode 3.3 MW component disclosure; listed alternatives are not a claim about every deployed turbine
LM Wind Power LM75.7 P2 Gen B → GE Vernova 3.8 MW-154m · standard documented model Explicit GE 3.8-154 component disclosure; listed alternatives are not a claim about every deployed turbine
Bonfiglioli LCVT320AL-690 → Bonfiglioli ACU 610-57 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV401A → Bonfiglioli ACU 410-51 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV401A → Bonfiglioli ACU 410-53 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV401A → Bonfiglioli ACU 410-55 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV401A → Bonfiglioli ACU 510-51 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV401A → Bonfiglioli ACU 510-53 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV401A → Bonfiglioli ACU 510-55 (frame 8) Component pairing only; no wind turbine compatibility
Flender JFWA-500SS-04A → Senvion Wind Technology 3.1M130 Explicit Senvion 3.1M130 component disclosure; listed alternatives are not a claim about every deployed turbine
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 210-01 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 210-03 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 210-05 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 210-07 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 210-09 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 210-11 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 410-01 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 410-03 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 410-05 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 410-07 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 410-09 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 410-11 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 410-13 (frame 2) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/8 → Bonfiglioli ACU 410-15 (frame 2) Component pairing only; no wind turbine compatibility
ABB ACS800-67LC-1375/1125-7 → ABB ACS800-104LC-0705-7+E205 Documented internal assembly relation only; no turbine compatibility inferred
ABB ACS800-67LC-1375/1125-7 → ABB ACS800-104LC-0705-7+E205 Documented internal assembly relation only; no turbine compatibility inferred
Inox Wind SR71-V2 with T-Bolts → Inox Wind DF/3000/145 Explicit INOX DF/3000/145 application only at hub heights100m and122.5m; not extended to140m
Bonfiglioli LCVT550AL-525 → Bonfiglioli ACU 410-57 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT550AL-525 → Bonfiglioli ACU 510-61 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli BR 471/136 → Bonfiglioli ACU 410-12 (frame 1) Quantity 1; duty cycle 25% at drive rated power; not turbine compatibility
Bonfiglioli BR 471/136 → Bonfiglioli ACU 410-13 (frame 2) Quantity 1; duty cycle 21% at drive rated power; not turbine compatibility
Bonfiglioli BR 471/136 → Bonfiglioli ACU 410-15 (frame 2) Quantity 1; duty cycle 16% at drive rated power; not turbine compatibility
Bonfiglioli LCVT135 → Bonfiglioli ACU 410-39 (frame 6) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT440AL-525 → Bonfiglioli ACU 410-55 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT440AL-525 → Bonfiglioli ACU 510-57 (frame 8) Component pairing only; no wind turbine compatibility
Suzhou Hopewind Electric HWDFM0693150 → Suzlon S144-3.0 / 3.15 MW Only S144-3.0 / 3.15 MW configurations in TC-240121 Rev.2, issued 2024-05-06. Certificate requires maintenance and approved design/quality changes; no current eligibility or deployed-fleet claim.
Delijia Transmission Technology (Jiangsu) WE4500S-01 → Sany Wind Energy India SI-16840 Only the exact turbine configuration named by this disclosure; listed alternatives are not universal deployed compatibility
ABB ACS880-87LC-8000A/8268A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
Siemens Gamesa B81 · standard documented model → Siemens Gamesa SG 8.0-167 DD · APAC 60 Hz announced 2018 Explicit SG 8.0-167 APAC announcement; no inferred other-model compatibility
Adani New Industries MWL78.6 → Adani New Industries MWL-160-5.2MW Explicit MWL160-5.2MW component disclosure; listed alternatives are not a claim about every deployed turbine
Adani New Industries MWL78.6 → Adani New Industries MWL-160-5.2MW HYT-140 m Explicit MWL-160-5.2MW HYT-140m component disclosure; listed alternatives are not a claim about every deployed turbine
Envision Energy EN89 VL → Envision Energy India EN-182-5.0 - 50 Hz Explicit EN-182/5.0 IEC S 50Hz component disclosure; listed alternatives are not a claim about every deployed turbine
ABB ACS880-77LC-1686A/1568A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
Bonfiglioli HLD 110-500/42 → Bonfiglioli ACU 210-22 (frame 4) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/42 → Bonfiglioli ACU 410-27 (frame 5) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT690AL-400 → Bonfiglioli ACU 410-59 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT690AL-400 → Bonfiglioli ACU 410-61 (frame 8) Component pairing only; no wind turbine compatibility
ABB ACS880-77LC-5006A/4656A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
ABB NEXA-21 extension unit → ABB NETA-21 remote monitoring tool Optional extension for NETA-21 only; no direct turbine or converter compatibility inferred. Wind context is the documented NETA-21 monitoring application.
Inox Wind WBSR146-3.0 → Inox Wind DF/3000/145 Explicit INOX DF/3000/145 application only at hub heights122.5m and140m; not extended to100m
Bonfiglioli LCVS015 → Bonfiglioli ACU 210-11 (frame 1) Component pairing only; no wind turbine compatibility
Sinomatech Wind Power Blade SI90.2 → Venwind Refex Power GWH182-5.3 Only the exact turbine configuration named by this disclosure; listed alternatives are not universal deployed compatibility
Bonfiglioli HLD 110-500/75 → Bonfiglioli ACU 410-31 (frame 5) Component pairing only; no wind turbine compatibility
Bergey Windpower Company Powersync 25 → Bergey Windpower Company Excel 15 Explicit EXCEL15 grid-intertie application; turbine itself not utility-interconnection protective equipment
Bonfiglioli LCVT250AL-690 → Bonfiglioli ACU 610-55 (frame 8) Component pairing only; no wind turbine compatibility
ABB ACS880-77LC-1720A/1600A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
ABB ACS880-87LC-6604A/6144A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
Bonfiglioli LCVT090 → Bonfiglioli ACU 410-35 (frame 6) Component pairing only; no wind turbine compatibility
LM Wind Power LM76.5P → Envision Energy India EN-156/3.3 Explicit EN-156/3.3 (LM76.5 P and EN 76.5 A V2) component disclosure; listed alternatives are not a claim about every deployed turbine
Bonfiglioli LCVT010 → Bonfiglioli ACU 210-13 (frame 2) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT010 → Bonfiglioli ACU 410-18 (frame 2) Component pairing only; no wind turbine compatibility
NGC CMG425AFF74-0212 → Venwind Refex Power GWH182-5.3 Only the exact turbine configuration named by this disclosure; listed alternatives are not universal deployed compatibility
Bonfiglioli FTV630A → Bonfiglioli ACU 410-57 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV630A → Bonfiglioli ACU 410-59 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV630A → Bonfiglioli ACU 410-61 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV630A → Bonfiglioli ACU 510-57 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV630A → Bonfiglioli ACU 510-59 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV630A → Bonfiglioli ACU 510-61 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVS010 → Bonfiglioli ACU 210-09 (frame 1) Component pairing only; no wind turbine compatibility
Envision Energy WE7200Y → Envision Energy India EN-182-5.0 - 50 Hz Explicit EN-182/5.0 IEC S 50Hz component disclosure; listed alternatives are not a claim about every deployed turbine
Sinoma Wind Power Blade YD80.5 → Adani New Industries WD164-3300 Explicit WD164-3300 component disclosure; listed alternatives are not a claim about every deployed turbine
ABB ACS800-67LC-1595/0865-7 → ABB ACS800-104LC-0555-7+E205 Documented internal assembly relation only; no turbine compatibility inferred
ABB ACS800-67LC-1595/0865-7 → ABB ACS800-104LC-0555-7+E205 Documented internal assembly relation only; no turbine compatibility inferred
LM Wind Power LM78.3P (Gen C) → Adani New Industries MWL-160-5.2MW Explicit MWL160-5.2MW component disclosure; listed alternatives are not a claim about every deployed turbine
Pioneer Wincon Energy Systems HT24 → Pioneer Wincon Energy Systems 750/49 HT24 IIIA 750/49:IIIA HH61.1/75.3m or IIIB HH61.5/75.0m only
Pioneer Wincon Energy Systems HT24 → Pioneer Wincon Energy Systems 750/49 HT24 IIIB 750/49:IIIA HH61.1/75.3m or IIIB HH61.5/75.0m only
Envision Energy WE3600Y → Envision Energy India EN-156/3.3 Explicit EN-156/3.3 (LM76.5 P and EN 76.5 A V2) component disclosure; listed alternatives are not a claim about every deployed turbine
Bonfiglioli LCVT470AL-525 → Bonfiglioli ACU 510-59 (frame 8) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV040B → Bonfiglioli ACU 410-23 (frame 4) Component pairing only; no wind turbine compatibility
Bonfiglioli FTV040B → Bonfiglioli ACU 410-25 (frame 4) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT060 → Bonfiglioli ACU 410-29 (frame 5) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT060 → Bonfiglioli ACU 410-31 (frame 5) Component pairing only; no wind turbine compatibility
Bonfiglioli BR 213/300 → Bonfiglioli ACU 410-01 (frame 1) Quantity 1; duty cycle 85% at drive rated power; not turbine compatibility
Bonfiglioli BR 213/300 → Bonfiglioli ACU 410-03 (frame 1) Quantity 1; duty cycle 57% at drive rated power; not turbine compatibility
Bonfiglioli BR 213/300 → Bonfiglioli ACU 410-05 (frame 1) Quantity 1; duty cycle 39% at drive rated power; not turbine compatibility
Bonfiglioli BR 213/300 → Bonfiglioli ACU 410-07 (frame 1) Quantity 1; duty cycle 28% at drive rated power; not turbine compatibility
Bonfiglioli BR 213/300 → Bonfiglioli ACU 410-09 (frame 1) Quantity 1; duty cycle 19% at drive rated power; not turbine compatibility
Bonfiglioli BR 213/300 → Bonfiglioli ACU 410-11 (frame 1) Quantity 1; duty cycle 14% at drive rated power; not turbine compatibility
NGC SMG282ADT113-0209 → Suzlon S144-3.0 / 3.15 MW Only S144-3.0 / 3.15 MW configurations in TC-240121 Rev.2, issued 2024-05-06. Certificate requires maintenance and approved design/quality changes; no current eligibility or deployed-fleet claim.
ABB ACS800-67LC-1375/0575-7 → ABB ACS800-104LC-0705-7+E205 Documented internal assembly relation only; no turbine compatibility inferred
ABB ACS800-67LC-1375/0575-7 → ABB ACS800-104LC-0705-7+E205 Documented internal assembly relation only; no turbine compatibility inferred
Bonfiglioli HLD 110-500/250 → Bonfiglioli ACU 410-47 (frame 7) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/250 → Bonfiglioli ACU 410-49 (frame 7) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT115 → Bonfiglioli ACU 410-37 (frame 6) Component pairing only; no wind turbine compatibility
ELIN Motoren MRM-063 Z06 → Inox Wind DF/3000/145 Explicit INOX DF/3000/145 3.0 MW Power Booster Mode 3.3 MW component disclosure; listed alternatives are not a claim about every deployed turbine
ABB ACS880-87LC-3302A/3072A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
Jiangsu Delijia Drive Technology WE7000G → Venwind Refex Power GWH182-5.3 Only the exact turbine configuration named by this disclosure; listed alternatives are not universal deployed compatibility
Xi’an Chen’an Electric YD3600FDJ-3 → Adani New Industries WD147-3000 Explicit WD147-3000 component disclosure; listed alternatives are not a claim about every deployed turbine
Hunan Xiangtan Electric Power YD3600FDJ-A (YJ339B) → Adani New Industries WD164-3300 Explicit WD164-3300 component disclosure; listed alternatives are not a claim about every deployed turbine
Bonfiglioli LCVT004 → Bonfiglioli ACU 210-01 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT004 → Bonfiglioli ACU 210-03 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT004 → Bonfiglioli ACU 210-05 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT004 → Bonfiglioli ACU 210-07 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT004 → Bonfiglioli ACU 410-01 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT004 → Bonfiglioli ACU 410-03 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT004 → Bonfiglioli ACU 410-05 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT004 → Bonfiglioli ACU 410-07 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT004 → Bonfiglioli ACU 410-09 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT004 → Bonfiglioli ACU 410-11 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT004 → Bonfiglioli ACU 410-12 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT360AL-690 → Bonfiglioli ACU 610-59 (frame 8) Component pairing only; no wind turbine compatibility
ABB ACS880-87LC-1686A/1568A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
Dalian Huarui Special Transmission Equipment CWTG750P/57-67-50 → Pioneer Wincon Energy Systems 750/57 PW28 IIIA Only the exact configuration in this manufacturer disclosure; Pioneer750/57 limited to90m hub; no deployed fleet or other mode inference
Bonfiglioli HLD 110-500/30 → Bonfiglioli ACU 210-18 (frame 3) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/30 → Bonfiglioli ACU 210-19 (frame 3) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/30 → Bonfiglioli ACU 210-21 (frame 4) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/30 → Bonfiglioli ACU 410-22 (frame 3) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/30 → Bonfiglioli ACU 410-23 (frame 4) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/30 → Bonfiglioli ACU 410-25 (frame 4) Component pairing only; no wind turbine compatibility
SANY (Shaoshan) Wind Power Equipment FB82036 → Sany Wind Energy India SI-16840 Only the exact turbine configuration named by this disclosure; listed alternatives are not universal deployed compatibility
Bonfiglioli BR 696/92 → Bonfiglioli ACU 410-18 (frame 2) Quantity 1; duty cycle 17% at drive rated power; not turbine compatibility
Tianjin CRRC Wind Turbine Blade Engineering TMT71.5E → Adani New Industries WD147-3000 Explicit WD147-3000 component disclosure; listed alternatives are not a claim about every deployed turbine
NGC SMG322BDT177-0181 → Sany Wind Energy India SI-16840 Only the exact turbine configuration named by this disclosure; listed alternatives are not universal deployed compatibility
Bonfiglioli LCVS018 → Bonfiglioli ACU 210-13 (frame 2) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT075 → Bonfiglioli ACU 410-33 (frame 6) Component pairing only; no wind turbine compatibility
ABB ACS800-67LC-1075/0575-7 → ABB ACS800-104LC-0705-7+E205 Documented internal assembly relation only; no turbine compatibility inferred
ABB ACS800-67LC-1075/0575-7 → ABB ACS800-104LC-0705-7+E205 Documented internal assembly relation only; no turbine compatibility inferred
Nanjing Turbine & Electric Machinery Changfeng New Energy GWH V12-TFY → Venwind Refex Power GWH182-5.3 Only the exact turbine configuration named by this disclosure; listed alternatives are not universal deployed compatibility
ABB ACS880-77LC-860A/800A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
Bonfiglioli LCVT006 → Bonfiglioli ACU 210-09 (frame 1) Component pairing only; no wind turbine compatibility
Bonfiglioli LCVT006 → Bonfiglioli ACU 410-13 (frame 2) Component pairing only; no wind turbine compatibility
Bonfiglioli HLD 110-500/55 → Bonfiglioli ACU 410-29 (frame 5) Component pairing only; no wind turbine compatibility
CG Power and Industrial Solutions SG055D06 → Suzlon S144-3.0 / 3.15 MW Only S144-3.0 / 3.15 MW configurations in TC-240121 Rev.2, issued 2024-05-06. Certificate requires maintenance and approved design/quality changes; no current eligibility or deployed-fleet claim.
ABB ACS880-87LC-2503A/2328A-7 → ABB NETA-21 remote monitoring tool Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration.
NGC CMG262ADT159-0035 → Adani New Industries WD147-3000 Explicit WD147-3000 component disclosure; listed alternatives are not a claim about every deployed turbine
Pioneer Wincon Energy Systems PW28 → Pioneer Wincon Energy Systems 750/57 PW28 IIIA 750/57 IIIA HH75.0/90.0m only
ZF Wind Power EF0953A → Suzlon S144-3.0 / 3.15 MW S144-3.0/3.15MW,3000/3150kW listed turbine rating only; no inferred3.3MW mode compatibility
Bonfiglioli LCVT050 → Bonfiglioli ACU 410-27 (frame 5) Component pairing only; no wind turbine compatibility
Beijing Sany Smart Electrical Machine YSK37-04 → Sany Wind Energy India SI-16840 Only the exact turbine configuration named by this disclosure; listed alternatives are not universal deployed compatibility
ABB ACS800-67-0480/0770-7 → ABB ACS800-104-0580-7 Documented internal assembly relation only; no turbine compatibility inferred
ABB ACS800-67-0480/0770-7 → ABB ACS800-104-0770-7 Documented internal assembly relation only; no turbine compatibility inferred
India ALMM observations: dated listing, not verified current eligibility
PowerWind 56 entry 28 listed kW [900] hub options m [71] certificate date as printed 3/7/2029 outstanding issue False restriction None
SIVA 250/50 entry 18 listed kW [250] hub options m [50] certificate date as printed 21/07/2026 outstanding issue False restriction None
750/49 HT24 IIIB entry 22 listed kW [750] hub options m [61.5, 75] certificate date as printed 5/12/2028 outstanding issue False restriction None
SI-16840 entry 25 listed kW [4000] hub options m [139] certificate date as printed 12/10/2028 outstanding issue False restriction None
WD164-3300 entry 3 listed kW [3300] hub options m [139.73] certificate date as printed 22/09/2029 outstanding issue False restriction None
S144-3.0 / 3.15 MW entry 9 listed kW [3000, 3150] hub options m [105, 130, 140, 160] certificate date as printed 26/03/2029 outstanding issue False restriction None
MWL-160-5.2MW HYT-140 m entry 4 listed kW [5200] hub options m [140] certificate date as printed 3/4/2029 outstanding issue False restriction None
MWL-160-5.2MW entry 1 listed kW [5200] hub options m [120] certificate date as printed 15/10/2026 outstanding issue False restriction Component-certificate expiry limits type-certificate validity to 15 October 2026.
S133 2.6 MW/2.8 MW/3.0 MW entry 10 listed kW [2600, 2800, 3000] hub options m [105, 140, 160] certificate date as printed 27/02/2027 outstanding issue False restriction None
2.3M130/2.7MW entry 15 listed kW [2700] hub options m [120, 130, 140] certificate date as printed 2/12/2026 outstanding issue False restriction Ria Blades serials RB002–RB031 are included for historical continuity only; no current/future-use approval implied.
GE 2.7-132 entry 30 listed kW [2730] hub options m [130, 94] certificate date as printed 10/8/2028 outstanding issue False restriction Valid enlistment statement restricted to units manufactured before5 March2026; 2730kW table rating retained despite2.7MW model label.
S120 DFIG 2.1 MW (50 Hz) entry 8 listed kW [2100] hub options m [81, 90, 105, 120, 140] certificate date as printed 4/1/2027 outstanding issue True restriction 2250kW enhanced performance mode is excluded from this list. Altitude maximum1000m. Pondicherry hub/nacelle assembly facility is excluded. Outstanding issue marked Yes.
GWL 225 entry 27 listed kW [225] hub options m [48.7] certificate date as printed 26/7/2026 outstanding issue False restriction None
AGW 147/4.2 entry 26 listed kW [4200] hub options m [120] certificate date as printed 1/11/2028 outstanding issue False restriction None
DF/2000/113 entry 12 listed kW [2000] hub options m [92] certificate date as printed 12/2/2027 outstanding issue False restriction None
EN-182-5.0 - 50 Hz entry 6 listed kW [5000] hub options m [130, 140] certificate date as printed 22/01/2030 outstanding issue False restriction 5250kW boost is excluded from ALMM consideration. Component certificate limits validity to 22 January 2030.
4.2M160 entry 17 listed kW [4200] hub options m [140] certificate date as printed 1/15/2031 outstanding issue False restriction Printed type-certificate expiry1/15/2031 is limited by gearbox CWTG4200/160-128-50 component expiry25 March2030; maker not inferred.
750/49 HT24 IIIA entry 21 listed kW [750] hub options m [61.1, 75.3] certificate date as printed 6/3/2029 outstanding issue False restriction None
WD147-3000 entry 2 listed kW [3000] hub options m [100] certificate date as printed 19/12/2028 outstanding issue False restriction None
GWH182-5.3 entry 29 listed kW [5300] hub options m [110, 130] certificate date as printed 12/21/2028 outstanding issue False restriction Gearbox types WE7000G and WE7000G-01 component expiry27 February2028 limits validity despite later type-certificate date; component manufacturer not inferred.
2.3M120 entry 14 listed kW [2300] hub options m [120] certificate date as printed 26/07/2027 outstanding issue False restriction None
3.1M130 entry 16 listed kW [3100] hub options m [130, 140] certificate date as printed 24/11/2027 outstanding issue False restriction Component-certificate expiry limits validity to24 November2027.
SIVA 225/40 entry 19 listed kW [225] hub options m [50] certificate date as printed 27/10/2026 outstanding issue False restriction Reported hub height is50m despite model suffix40. Preserve reported geometry, do not infer40m.
EN-156/3.3 entry 5 listed kW [3300] hub options m [120, 123, 140, 143] certificate date as printed 5/7/2029 outstanding issue False restriction Type-certificate column says 5/7/2029, but the remark limits validity to component expiry 25 May 2027. Site altitude maximum 2000m.
V155-3.6 MW entry 11 listed kW [3600] hub options m [102.5, 105, 118, 120, 136, 137] certificate date as printed 1/12/2027 outstanding issue False restriction None
750/57 PW28 IIIA entry 23 listed kW [750] hub options m [75] certificate date as printed 4/11/2029 outstanding issue False restriction None
750/57 PW28 IIIA entry 24 listed kW [750] hub options m [90] certificate date as printed 30/07/2030 outstanding issue False restriction None
3.8 MW-154m entry 7 listed kW [3800] hub options m [135.5] certificate date as printed 12/3/2026 outstanding issue True restriction Outstanding issue marked Yes; printed type-certificate expiry precedes list date. No current eligibility claimed. Indian hub135.5m retained as regional observation beside existing OEM135m option; equivalence unresolved.
DF/3000/145 entry 13 listed kW [3000] hub options m [100, 122.5, 140] certificate date as printed 2/18/2030 outstanding issue False restriction 3300kW power-boost mode documented in addition to3000kW rating.
French network installations: dated capacity observations, excluded from totals
name region status_as_of installed_capacity_mw export_capacity_mw aggregation_role
FERME EOLIENNE D AVESSAC Pays de la Loire 2026-08-31 10.19000 10.190 unresolved
FERME EOLIENNE DU HAUT VIGNOBLE Pays de la Loire 2026-08-31 13.56000 13.200 unresolved
EE BRAY - Normandie 2026-08-31 12.30000 12.300 unresolved
BORALEX LES COTEAUX DU BLAISERON Grand Est 2026-08-31 12.80000 12.800 unresolved
PARC EOLIEN DU CATESIS Hauts-de-France 2026-08-31 10.00000 10.000 unresolved
PARC DU FIEF SAUVIN Pays de la Loire 2026-08-31 14.40000 13.200 unresolved
EOLIENNE CARRE SENART Île-de-France 2026-08-31 0.13200 0.132 unresolved
PARC EOLIEN DES AVALOIRS Pays de la Loire 2026-08-31 9.00000 9.000 unresolved
PARC EOLIEN DU BOIS RICART Hauts-de-France 2026-08-31 13.80000 13.800 unresolved
PARC EOLIEN D AMOURES BOUISSAC Occitanie 2026-08-31 14.10000 14.100 unresolved
AILES DES CRETES C2 HEBERGEUR Grand Est 2026-08-31 2.40000 1.600 unresolved
PARC EOLIEN DES COMBONNANTS Nouvelle-Aquitaine 2026-08-31 12.00000 12.000 unresolved
PARC EOLIEN GUERHARO Bretagne 2026-08-31 4.80000 4.800 unresolved
SRD - EOLIENNES DES TERRES ROUGES Nouvelle-Aquitaine 2026-08-31 15.00000 15.000 unresolved
EOL-PLENITUDE Normandie 2026-08-31 10.25000 10.250 unresolved
PARC EOLIEN DES SAULES sitedeprod Hauts-de-France 2026-08-31 20.00000 16.800 unresolved
ENERGIE EOLIENNE LUSANGER Pays de la Loire 2026-08-31 8.00000 8.000 unresolved
Eoliennes des Pivoines Bourgogne-Franche-Comté 2026-08-31 14.85000 13.200 unresolved
BESSIERES-VIDAL Occitanie 2026-08-31 0.90000 0.900 unresolved
PARC EOLIEN DES ROSSIGNOLS Hauts-de-France 2026-08-31 6.24000 6.000 unresolved
MONTREUIL EN CAUX Normandie 2026-08-31 14.40000 13.125 unresolved
EOLIENNES DU CHAMP CHARDON Hauts-de-France 2026-08-31 10.25000 10.250 unresolved
PARC EOLIEN DES CHAUMES CARREES Nouvelle-Aquitaine 2026-08-31 11.34000 11.340 unresolved
SAS PARC ÉOLIEN DU BEAUJOLAIS VERT Auvergne-Rhône-Alpes 2026-08-31 12.00000 12.000 unresolved
CENTRALE EOLIENNE DES BEAUX MONTS Bourgogne-Franche-Comté 2026-08-31 8.80000 8.800 unresolved
PARC EOLIEN ROCHER BRETON Bretagne 2026-08-31 9.20000 9.200 unresolved
ARMAILLE Pays de la Loire 2026-08-31 9.57000 9.570 unresolved
PE D AMFREVILLE LES CHAMPS Normandie 2026-08-31 6.78000 6.600 unresolved
PARC EOLIEN LES TAMBOURS Hauts-de-France 2026-08-31 8.35000 8.350 unresolved
FERME EOLIENNE LAUNSTROFF Grand Est 2026-08-31 10.00000 10.000 unresolved
FERME EOLIENNE DES DEUX MOULINS Hauts-de-France 2026-08-31 11.75000 11.750 unresolved
PARC DES VENTS DES NOËS Auvergne-Rhône-Alpes 2026-08-31 17.00000 17.000 unresolved
PARC EOLIEN LES BALLENDAUX Normandie 2026-08-31 10.00000 10.000 unresolved
PARC EOLIEN D AULNOIS Grand Est 2026-08-31 9.60000 9.600 unresolved
EOLIENNES COURCOME Nouvelle-Aquitaine 2026-08-31 15.00000 15.000 unresolved
ENERGIES DES MONTS BERGERONS Hauts-de-France 2026-08-31 10.00000 10.000 unresolved
PARC EOLIEN D ESCARDES Grand Est 2026-08-31 12.00000 12.000 unresolved
PARC EOLIEN DU TELEGRAPHE Bourgogne-Franche-Comté 2026-08-31 15.20000 14.400 unresolved
PARC EOLIEN DU LOUVENG Hauts-de-France 2026-08-31 11.30000 11.000 unresolved
EOLIENNES DES LUPINS Hauts-de-France 2026-08-31 13.80000 12.000 unresolved
CENTRALE EOLIENNE LES HAUTS CHEMINS Grand Est 2026-08-31 15.00000 14.000 unresolved
FERME EOLIENNE DU CAGNEUX Hauts-de-France 2026-08-31 11.75000 11.750 unresolved
PARC EOLIEN D'ANDILLY LES MARAIS Nouvelle-Aquitaine 2026-08-31 16.80000 16.800 unresolved
PARC EOLIEN DU BOIS DU GOULET Normandie 2026-08-31 10.00000 10.000 unresolved
TRIBALLAT NOYAL Bretagne 2026-08-31 0.80000 0.800 unresolved
PARC EOLIEN DES 3 COMMUNES Hauts-de-France 2026-08-31 9.20112 9.200 unresolved
SOPRELTA Bourgogne-Franche-Comté 2026-08-31 6.00000 6.000 unresolved
EOLIENNES DU TREFLE Hauts-de-France 2026-08-31 10.80000 10.800 unresolved
PARC EOLIEN D APREMONT Auvergne-Rhône-Alpes 2026-08-31 11.75000 11.750 unresolved
TRAMOMARINA Grand Est 2026-08-31 10.25000 10.250 unresolved
INNOVENT LEFAUX Hauts-de-France 2026-08-31 0.90000 0.900 unresolved
SEPE LES CHAMPS TROUVES Nouvelle-Aquitaine 2026-08-31 6.60000 6.600 unresolved
EOLIENNES DU MONT D'HIETTE Hauts-de-France 2026-08-31 15.30000 11.960 unresolved
PARC EOLIEN DES MARNIERES site Hauts-de-France 2026-08-31 6.78000 6.600 unresolved
CENTRALE EOLIENNE DU PAYS CHAUMONTAIS Grand Est 2026-08-31 14.40000 14.400 unresolved
PARC EOLIEN D'HAUCOURT_PM Normandie 2026-08-31 8.00000 7.200 unresolved
EOLIENNES SASSEVILLE ET DROSAY Normandie 2026-08-31 15.00000 15.000 unresolved
CENTRALE EOLIENNE DES SOUTETS Occitanie 2026-08-31 13.80000 13.800 unresolved
ECHAUFFOUR ENERGIES Normandie 2026-08-31 10.00000 10.000 unresolved
PARC EOLIEN D AZERABLES Nouvelle-Aquitaine 2026-08-31 13.20000 12.000 unresolved
PARC EOLIEN DES HERBES SAUVAGES Nouvelle-Aquitaine 2026-08-31 12.20000 12.000 unresolved
PARC EOLIEN LES CAVES SAS Pays de la Loire 2026-08-31 11.50000 11.500 unresolved
FERME EOLIENNE TILLIERES Pays de la Loire 2026-08-31 9.20000 9.200 unresolved
PARC EOLIEN D ALLAINVILLE AUX BOIS Île-de-France 2026-08-31 17.00000 17.000 unresolved
PARCS EOLIENS DES TERRES BLANCHES Grand Est 2026-08-31 4.25000 4.250 unresolved
BOUSSAY ENERGIES Pays de la Loire 2026-08-31 7.20000 7.200 unresolved
VENTS DES CHAMPS Hauts-de-France 2026-08-31 8.80000 8.800 unresolved
TREFFENDEL LANDELLES Bretagne 2026-08-31 8.32000 8.200 unresolved
FERME EOLIENNE DU HAUT SEGREEN Pays de la Loire 2026-08-31 6.24000 6.000 unresolved
SARL DEBAENE Hauts-de-France 2026-08-31 0.40000 0.400 unresolved
FOYE ENERGIES Nouvelle-Aquitaine 2026-08-31 10.25000 10.250 unresolved
VENDEE EOLIEN Pays de la Loire 2026-08-31 8.00000 8.000 unresolved
PARC EOLIEN ANGRIE Pays de la Loire 2026-08-31 11.00000 11.000 unresolved
REE SARL Nouvelle-Aquitaine 2026-08-31 8.00000 8.000 unresolved
CPENR LES CHAMPARTS Centre-Val de Loire 2026-08-31 12.00000 12.000 unresolved
PARC EOLIEN HAIMPS ET MASSAC - PRODUCTION MORALE Nouvelle-Aquitaine 2026-08-31 8.80000 8.800 unresolved
PARC EOLIEN SIOULET CHAVANON SUD Auvergne-Rhône-Alpes 2026-08-31 4.80000 4.800 unresolved
EOLIENNE POUTAS Normandie 2026-08-31 0.08800 0.088 unresolved
SEPE LES HAYETTES Hauts-de-France 2026-08-31 7.05000 7.050 unresolved
ENERGIE RENOUVELABLE DU LANGUEDOC Occitanie 2026-08-31 16.10000 16.100 unresolved
EOLIENNE DDIS60 SITE D ONNAING Hauts-de-France 2026-08-31 0.80000 0.800 unresolved
PARC EOLIEN BOIS D ANCHAT Centre-Val de Loire 2026-08-31 10.00000 10.000 unresolved
EE NOYAL-SiteProductionMorale Bretagne 2026-08-31 7.00000 7.000 unresolved
LHI SOLARWIND WP SARTHE 2569-PRODUCTION MORALE Pays de la Loire 2026-08-31 9.00000 9.000 unresolved
PARC EOLIEN CUQ SERVIES Occitanie 2026-08-31 12.00000 12.000 unresolved
SAS ENERGIE BOULE BLEUE Hauts-de-France 2026-08-31 14.10000 14.100 unresolved
EOLIENNES DU SOISSONNAIS Hauts-de-France 2026-08-31 12.00000 12.000 unresolved
FERME EOLIENNE DU CONFOLENTAIS SNC Nouvelle-Aquitaine 2026-08-31 12.22800 12.228 unresolved
WPD Hauts-de-France 2026-08-31 11.75000 11.750 unresolved
AVESNES ET BOSC-HYONS Normandie 2026-08-31 15.20000 12.000 unresolved
TIERCELINE ENERGIES SARL Nouvelle-Aquitaine 2026-08-31 10.25000 10.250 unresolved
LHI GII2 WP Plesidy 2496 SAS Bretagne 2026-08-31 11.00000 11.000 unresolved
Trois Cantons Enr Bourgogne-Franche-Comté 2026-08-31 9.00000 9.000 unresolved
FERME EOLIENNE MACHAULT Grand Est 2026-08-31 16.95000 16.950 unresolved
THIMERT Centre-Val de Loire 2026-08-31 2.00000 2.000 unresolved
CEMAZ Hauts-de-France 2026-08-31 12.80000 12.800 unresolved
PARC EOLIEN DU MONT MOYEN Hauts-de-France 2026-08-31 14.10000 14.100 unresolved
PARC EOLIEN LES TRENTES Hauts-de-France 2026-08-31 10.40000 10.000 unresolved
FERME EOLIENNE COTEAUX Pays de la Loire 2026-08-31 13.80168 13.800 unresolved
FERME ÉOLIENNE D'YROUERRE Bourgogne-Franche-Comté 2026-08-31 12.00000 12.000 unresolved
PARC EOLIEN D'ALLENAY Hauts-de-France 2026-08-31 8.80000 8.800 unresolved
BEAUCE ORATORIENNE Centre-Val de Loire 2026-08-31 8.80000 8.800 unresolved
CELAN Nouvelle-Aquitaine 2026-08-31 12.00000 12.000 unresolved
PARC EOLIEN D YPREVILLE Normandie 2026-08-31 12.48000 12.000 unresolved
PARC EOLIEN DES MONTS Normandie 2026-08-31 8.00000 8.000 unresolved
AILES DES CRETES B1 HEBERGE Grand Est 2026-08-31 0.80000 0.800 unresolved
SEPE LES GARACHES Hauts-de-France 2026-08-31 15.60000 15.600 unresolved
INNOVENT BOISBERGUES Hauts-de-France 2026-08-31 3.00200 3.000 unresolved
SAS ISAC-WATTS Pays de la Loire 2026-08-31 8.63200 8.200 unresolved
PARC EOLIEN D ORMOY Centre-Val de Loire 2026-08-31 6.90000 6.000 unresolved
PARC EOLIEN DU BLANC MONT Hauts-de-France 2026-08-31 13.80000 13.800 unresolved
PARC EOLIEN - LES BUISSONS SUD Grand Est 2026-08-31 7.20000 7.200 unresolved
CEPE DU BLAISERON SARL Grand Est 2026-08-31 12.00000 12.000 unresolved
TEILLAY ENERGIES Bretagne 2026-08-31 8.00000 8.000 unresolved
ENERGIES DES LONGS CHAMPS Normandie 2026-08-31 11.50000 11.500 unresolved
Parc éolien des Blanches Fosses Hauts-de-France 2026-08-31 11.00000 11.000 unresolved
PARC EOLIEN DU HOUSSA Bretagne 2026-08-31 8.00000 8.000 unresolved
PARC EOLIEN DU MERCORBON - PRODUCTION MORALE Pays de la Loire 2026-08-31 9.60000 9.600 unresolved
PARC EOLIEN VILLACERF Grand Est 2026-08-31 10.00000 10.000 unresolved
EOLIENNES DES TROIS PLAINES Normandie 2026-08-31 10.40000 10.000 unresolved
PARC EOLIEN DES MOULINS Hauts-de-France 2026-08-31 10.00000 10.000 unresolved
VALLE MADAME Hauts-de-France 2026-08-31 11.50000 11.500 unresolved
CHAMPS PERDUS Hauts-de-France 2026-08-31 12.80000 12.000 unresolved
ENERGIE DU TOUVENT Pays de la Loire 2026-08-31 7.05000 7.050 unresolved
CEFOR Nouvelle-Aquitaine 2026-08-31 12.00000 10.200 unresolved
ENERGIE DU PARTAGE Grand Est 2026-08-31 15.00000 15.000 unresolved
AERODIS HERBITZHEIM Grand Est 2026-08-31 10.40000 10.000 unresolved
SEPE BOIS DES CORPS Grand Est 2026-08-31 4.00000 4.000 unresolved
Parc eolien d ENVRONVILLE Normandie 2026-08-31 8.80000 8.800 unresolved
No surveyed coordinates inferred from French administrative geography.
Geographic counts describe this catalogue. Missing status is never operational.
fig, axes = plt.subplots(2, 2, figsize=(15, 11), layout="constrained")
projects.country_code.value_counts().head(15).sort_values().plot.barh(ax=axes[0, 0])
axes[0, 0].set(title="15 most represented countries; historical baseline", xlabel="Records")
capacities = []
for field in ("installed_capacity_mw", "commissioned_capacity_mw", "planned_capacity_mw"):
summary = capacity_summary(rows, field)
print(field, summary)
for status, value in summary["by_status"].items():
capacities.append(
{
"category / dated lifecycle": f"{field.split('_')[0]} / {status}",
"Reported MW": value["reported_mw"],
}
)
pd.DataFrame(capacities).set_index("category / dated lifecycle").plot.barh(
ax=axes[0, 1], legend=False, color="#198c92"
)
axes[0, 1].set(title="Reviewed scope only; categories are not additive", xlabel="Reported MW")
equipment.manufacturer.value_counts().sort_values().plot.barh(ax=axes[1, 0], color="#ad8050")
axes[1, 0].set(title="Exact equipment configurations; not deployed market share", xlabel="Records")
fields = ["installed_capacity_mw", "planned_capacity_mw", "turbine_count", "rotor_diameter_m"]
pd.DataFrame(
{"Known": projects[fields].notna().sum(), "Unknown": projects[fields].isna().sum()}
).plot.barh(stacked=True, ax=axes[1, 1], color=["#198c92", "#dedede"])
axes[1, 1].set(title="Completeness across all project scopes", xlabel="Records")

installed_capacity_mw {'excluded': 8475, 'unknown': 3, 'by_status': {'operational': {'reported_mw': 2312.8999999999996, 'records': 12}}}
commissioned_capacity_mw {'excluded': 8475, 'unknown': 15, 'by_status': {}}
planned_capacity_mw {'excluded': 8475, 'unknown': 14, 'by_status': {'announced': {'reported_mw': 400.0, 'records': 1}}}
Scalar ratings exclude flexible ranges and unresolved values. Hub options remain one list per configuration; no artificial model expansion is performed.
fig, axes = plt.subplots(1, 2, figsize=(14, 6), layout="constrained")
comparable = equipment.loc[
equipment.equipment_category.eq("wind_turbine")
& equipment.rated_power_kw.notna()
& equipment.rotor_diameter_m.notna()
# These source ratings are power at 11 m/s, not nameplate densities.
& ~equipment.sources.apply(
lambda ids: any(
source in ids for source in ("pnnl_small_wind_july2026", "sdwind_sd12_20261104")
)
)
]
for manufacturer, group in comparable.groupby("manufacturer"):
values = [
specific_power_w_m2(p, d)
for p, d in zip(group.rated_power_kw, group.rotor_diameter_m, strict=True)
]
axes[0].scatter(group.rotor_diameter_m, values, label=manufacturer)
axes[0].set(
xlabel="Published rotor diameter (m)",
ylabel="Derived nameplate W/m²",
title="Specific power; not measured energy yield",
)
axes[0].legend(fontsize="small", ncol=2)
print("Exact model and hub-height options:")
print(
equipment[["manufacturer", "model", "variant", "hub_height_options_json"]].to_string(
index=False
)
)
offshore = projects.loc[
projects.technology.isin(["fixed_bottom_offshore", "floating_offshore"])
& projects.aggregation_role.ne("aggregate")
]
print("Offshore foundations and water-depth ranges; unknown remains unknown:")
print(
offshore[["name", "foundation_type", "water_depth_min_m", "water_depth_max_m"]].to_string(
index=False
)
)
depth = offshore.loc[offshore.water_depth_min_m.notna()]
axes[1].barh(depth.name, depth.water_depth_min_m, color="#198c92", label="Minimum reported")
axes[1].barh(
depth.name,
depth.water_depth_max_m - depth.water_depth_min_m,
left=depth.water_depth_min_m,
color="#9acdcc",
label="Reported range",
)
axes[1].set(xlabel="Water depth (m)", title="Offshore depth; only reported ranges")
axes[1].legend()
print("Published mixed-fleet models (counts can remain unknown):")
for row in rows:
if row.get("fleet_json"):
print(row["name"], json.loads(row["fleet_json"]))

Exact model and hub-height options:
manufacturer model variant hub_height_options_json
Bonfiglioli ACU 201-21 ACU201 230V class; VEC521R6 None
Bonfiglioli ACU 410-29 Frame size 5; R04_0 documented configuration None
Doosan WinDS3000/134 Onshore KS WT-1801-01-161129; 2018.01.31 onshore certification scope {"conditions":"Certificate listed hub options; not selected installation or paired power modes","heights_m":[90.0,120.0]}
Unison U57 KS WT-MLWS-2-0017; 2015.12.30 onshore certification scope None
Vestas V117-3.45 MW Power Mode FGW explicitly published configuration; hub options nested None
Bonfiglioli ACU 410-53 Frame size 7; R04_0 documented configuration None
Acciona Windpower AW82/1500 published type None
HARTING 09330006104 OEM part 09330006104; UK public specification None
ABB ACS880-77LC-2503A/2328A-7 Rev A 2018; single cabinet None
ENERCON E-103 EP2 OEM named model; optional OM02sBV retained within record None
ABB ACS800-104LC-1075-7 3AUA0000058400 Rev C None
Bonfiglioli 707 TW 700TW model; application-specific peak ratings retained together None
ABB ACS800-67LC-2035/1125-7 3AUA0000058400 Rev C None
Vertiv Tech (Mianyang) WF1000-06L0270-CPN-A Exact disclosed type; manufacturing sites and turbine applications nested None
ABB ACS800-204LC-0865-7+E205 3AUA0000058400 Rev C None
Vestas V162-6.2 MW published model {"not_all_combinations_available":true,"published_options":"119 m (IEC S/DIBt S), 125 m (IEC S), 149 m (IEC S), 166 m (IEC S/DIBt S) and 169 m (DIBt S)","unit":"m"}
Vestas V120-2.2 MW published model None
Bonfiglioli ACU 401-13 ACU401 400V class; VEC521R6 None
Bonfiglioli ACU 610-61 Frame size 8; R04_0 documented configuration None
Siemens Gamesa SG 5.0-145 2.0 {"site_specific":true,"values_m":[90,102.5,127.5]}
PowerWind PowerWind 56 India ALMM as on2026-08-20; tower/power options nested {"options_m":[71],"tower_scope":"Three-section tubular steel"}
Doosan WinDS3000/134 Offshore KS WT-1901-00-170144; 2019.02.19 offshore certification scope None
Nordex N117/3000 published type None
SD Wind Energy, Ltd. SD6 PNNL July 2026 listed model; electrical/region options unspecified {"conditions":"SDMK106 hydraulic Taperfit monopole options","heights_m":[9,15,20]}
Bonfiglioli LCVT008 R04_0 exact line-choke type None
HI-VAWT Technology Corporation / Colite Technologies DS3000 PNNL July 2026 listed model; electrical/region options unspecified None
Bonfiglioli FTV400A-690 R04_0 exact component type None
Nordex N90/2500 published type None
Bonfiglioli ACU 401-47 ACU401 400V class; VEC521R6 None
SANY Renewable Energy Co., Ltd. SI-16050 Global English technical table; region/frequency/revision unspecified None
Windey WD164-3600 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Siva Wind Turbine India SIVA 250/50 India ALMM as on2026-08-20; tower/power options nested {"options_m":[50],"tower_scope":"Four-leg lattice steel"}
Bonfiglioli LCVS006 R04_0 exact line-choke type None
Bonfiglioli ACU 410-15 Frame size 2; R04_0 documented configuration None
ABB ACS800-104LC-1595-7 3AUA0000058400 Rev C None
Pioneer Wincon Energy Systems 750/49 HT24 IIIB India ALMM as on2026-08-20; tower/power options nested {"options_m":[61.5,75],"tower_scope":"Four-leg lattice steel with tower-top adapter"}
VENSYS Energy AG VENSYS 136 3.5 MW; July 2025 technical sheet {"options":[{"height_m":81.7,"iec_class":"IEC IIIA","tower_type":"steel tube"},{"height_m":97.2,"iec_class":"IEC IIIA","tower_type":"steel tube"},{"height_m":110,"iec_class":"IEC S","tower_type":"segmented steel"},{"height_m":131.7,"iec_class":"IEC IIIA","tower_type":"hybrid concrete/steel"},{"height_m":161.2,"iec_class":"IEC IIIA","tower_type":"hybrid concrete/steel"}]}
ENERCON E-160 EP5 E3 08/2026 technical sheet; documented power and tower options retained {"height_m_by_iec_design_class":{"IEC S":[99,120,140,160,166]},"note":"Design class claim, not independently verified certification"}
Bonfiglioli LCVT350AL-525 R04_0 exact component type None
Bonfiglioli ACU 201-09 ACU201 230V class; VEC521R6 None
Sany Wind Energy India SI-16840 India ALMM as on2026-08-20; tower/power options nested {"options_m":[139],"tower_scope":"Tubular steel"}
Siemens Gamesa SG 2.6-114 standard documented model {"site_specific":true,"values_m":[93,125]}
Bonfiglioli ACU 401-22 ACU401 400V class; VEC521R6 None
Nordex N43 Mk3 FGW explicitly listed type/revision; hub options nested None
NGC SYW03 Standardized yaw drive type; options retained within model None
Vestas V236-15.0 MW published model None
Bonfiglioli ACU 410-19 Frame size 3; R04_0 documented configuration None
Siemens Gamesa SG 8.0-167 DD standard documented model None
Vestas V172-7.2 MW published model {"not_all_combinations_available":true,"published_options":"114 m (IEC S), 150 m (IEC S), 164 m (DIBt), 166 m (IEC S), 175 m (DIBt) and 199 m (DIBt)","unit":"m"}
Nordex N80/2500 published type None
Flender PDFJ 2776 Exact disclosed type; manufacturing sites and turbine applications nested None
Bonfiglioli LCVS008 R04_0 exact line-choke type None
CRRC Zhuzhou Times New Material Technology 4.XMW-82 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m None
Bonfiglioli ACU 410-33 Frame size 6; R04_0 documented configuration None
Bonfiglioli BR 4000/16 R04_0 exact braking resistor type None
ABB ACS880-87LC-4000A/3800A-7 Rev A 2018; single cabinet None
Acciona Windpower AW125/3000 published type None
Windey WD115-2000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Nexans TSLF-O 24kV 1x240A M Norwegian catalogue product ID540453318 None
ABB ACS880-87LC-8000A/7600A-7 Rev A 2018; twin cabinet None
Windey WD172-3600 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli LCVT200AL-690 R04_0 exact component type None
Adani New Industries WD164-3300 India ALMM as on2026-08-20; tower/power options nested {"options_m":[139.73],"tower_scope":"Tubular steel"}
Windey WD225-10000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Suzlon S144-3.0 / 3.15 MW India ALMM as on2026-08-20; tower/power options nested {"options_m":[105,130,140,160],"tower_scope":"105/140m tubular steel;130/140/160m hybrid lattice"}
Vestas V162-5.6 MW FGW explicitly published configuration; hub options nested None
Nexans TSLF-O 24kV 1x400A MP Norwegian catalogue product 10551185 None
ABB ACS880-87LC-5006A/4656A-7 Rev A 2018; twin cabinet None
Bonfiglioli BR 432/37 R04_0 exact braking resistor type None
Vestas V150-6.0 MW published model {"not_all_combinations_available":true,"published_options":"105 m (IEC S), 125 m (IEC S/DIBt S), 148 m (DIBt S), 155 m (IEC S) and 166 m (DIBt S)","unit":"m"}
CRRC Zhuzhou Times New Material Technology 4.XMW-76 Published OEM blade table 2022-03-03; wind class SC; root pitch-circle 2.8 m None
Goldwind GWH182-6.0MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
Vestas V90 3MW FGW explicitly published configuration; hub options nested None
Bonfiglioli ACU 210-01 Frame size 1; R04_0 documented configuration None
Bonfiglioli ACU 410-03 Frame size 1; R04_0 documented configuration None
Hyosung HS90 KS WT-MLWS-2-0001; 2014.08.25 onshore certification scope None
Adani New Industries MWL-160-5.2MW HYT-140 m India ALMM as on2026-08-20; tower/power options nested {"options_m":[140],"tower_scope":"Hybrid"}
Windey WD200-7500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Vestas V117-4.2 MW published model {"not_all_combinations_available":true,"published_options":"84 m (IEC IIA) and 91.5 m (IEC IB)","unit":"m"}
Vestas V63/1.5MW FGW explicitly published configuration; hub options nested None
Bonfiglioli LCVT160 R04_0 exact line-choke type None
Unison U136 TCS KS WT-2202-02-221035; 2022.09.29 onshore certification scope {"conditions":"Certificate listed hub options; not selected installation or paired power modes","heights_m":[117.0,125.0]}
Windey WD110-2000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Windey WD195-6600 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli BR 1333/12 R04_0 exact braking resistor type None
Senvion Wind Technology SE 63.7 Exact disclosed type; manufacturing sites and turbine applications nested None
Windey WD147-3600 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli BR 2000/32 R04_0 exact braking resistor type None
Bonfiglioli ACU 401-12 ACU401 400V class; VEC521R6 None
ebm-papst W2E143-AA09-01 10952-5-9970 ENU change260800 approved2022-07-13 None
CRRC Zhuzhou Times New Material Technology 3.XMW-76 Published OEM blade table 2022-03-03; wind class SC; root pitch-circle 2.8 m None
Nexans TSLF-O 24kV 1x50A M Norwegian catalogue product ID540453321 None
Adani New Industries MWL-160-5.2MW India ALMM as on2026-08-20; tower/power options nested {"options_m":[120],"tower_scope":"Tubular"}
Nordex N43 Mk1 FGW explicitly listed type/revision; hub options nested None
Bonfiglioli HLD 110-500/130 R04_0 exact component type None
Nordex N149/4.X published model {"not_all_combinations_available":true,"published_options":"up to 164 m, project – and sitespecific","unit":"m"}
Bonfiglioli LCVT250 R04_0 exact line-choke type None
ABB ACS800-67-0480/0580-7 3AFE68392454 Rev C None
Nexans TSLF-O 36kV 1x150A Norwegian catalogue product 10540620 None
HARTING 09330006102 OEM part 09330006102; UK public specification None
HARTING 09210153001 OEM part 09210153001; UK public specification None
VENSYS Energy AG VENSYS 62 1.5 MW; July 2025 technical sheet {"options":[{"height_m":49,"iec_class":"IEC S","tower_type":"steel tube"}]}
Nordex N131/3000 published type None
Nordex N100 printed 2500 kW version None
Bonfiglioli ACU 410-31 Frame size 5; R04_0 documented configuration None
Bonfiglioli LCVT210 R04_0 exact line-choke type None
Vestas V25 FGW explicitly published configuration; hub options nested None
SANY Renewable Energy Co., Ltd. SI-16850 Global English technical table; region/frequency/revision unspecified None
Windey WD147-3000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Goldwind GWH182-7.2MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
Windey WD156-3300 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli ACU 210-13 Frame size 2; R04_0 documented configuration None
Bonfiglioli ACU 201-18 ACU201 230V class; VEC521R6 None
Nordex N169/5.X published model {"not_all_combinations_available":true,"published_options":"111,5 m (initiales Angebot)","unit":"m"}
GE Vernova 6.1 MW-158m standard documented model {"50_Hz":[96,101,121,150,161],"60_Hz":[101,117]}
Windey WD164-4500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Jiangsu Delijia Drive Technology WE7000G-01 Exact disclosed type; manufacturing sites and turbine applications nested None
Windey WD200-5000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Siemens Gamesa SG 4.3-120 standard documented model {"site_specific":true,"values_m":[76.5,85,94]}
Vestas V20 FGW explicitly published configuration; hub options nested None
Bonfiglioli BR 667/24 R04_0 exact braking resistor type None
Nordex N52 printed 1000 kW version None
Suzlon SB70 (SB70S1) Exact disclosed type; manufacturing sites and turbine applications nested None
Wind Resource, LLC Skystream 3.7 PNNL July 2026 listed model; electrical/region options unspecified None
Siemens Gamesa SG 4.3-130 standard documented model {"site_specific":true,"values_m":[85,94,115,135]}
Suzlon S133 2.6 MW/2.8 MW/3.0 MW India ALMM as on2026-08-20; tower/power options nested {"options_m":[105,140,160],"tower_scope":"105m tubular steel;140m hybrid lattice or modular hybrid lattice;160m modular hybrid lattice"}
Bonfiglioli LCVT215AL-525 R04_0 exact component type None
Senvion Wind Technology 2.3M130/2.7MW India ALMM as on2026-08-20; tower/power options nested {"options_m":[120,130,140],"tower_scope":"Tubular steel"}
Nordex N100 / 2500 IEC3A FGW explicitly listed type/revision; hub options nested None
Bonfiglioli 710 TW 700TW model; application-specific peak ratings retained together None
Nordex N163/6.X published model {"not_all_combinations_available":true,"published_options":"up to 164m, project – and sitespecific","unit":"m"}
ABB NPBU-42 3AFE68392454 Rev C None
Nordex N90/2300 published type None
Bonfiglioli 709 TW 700TW model; application-specific peak ratings retained together None
Bonfiglioli ACU 201-13 ACU201 230V class; VEC521R6 None
Nordex N193/7.X published model {"not_all_combinations_available":true,"published_options":"up to 181 m, project and site specific tower options","unit":"m"}
Bonfiglioli ACU 510-53 Frame size 8; R04_0 documented configuration None
Bonfiglioli LCVT280AL-525 R04_0 exact component type None
Windey WD164-4200 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli ACU 610-55 Frame size 8; R04_0 documented configuration None
Vestas V150-4.0 MW, Mode 0 FGW explicitly published configuration; hub options nested None
ABB ACS800-67-0480/1160-7 3AFE68392454 Rev C None
Acciona Windpower AW77/1500 published type None
Windey WD172-4000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli ACU 210-21 Frame size 4; R04_0 documented configuration None
Goldwind GW 87/1500 Americas English1.5MW brochure; revision unspecified; options not expanded None
ABB ACS800-204LC-1125-7+E205 3AUA0000058400 Rev C None
Nexans TSLF-O 36kV 1x150A M Norwegian catalogue product ID540453314 None
Nordex N131/3300 published type None
Bonfiglioli ACU 401-23 ACU401 400V class; VEC521R6 None
Nexans TSLF-O 24kV 1x95A M Norwegian catalogue product ID540453320 None
SkyWind Energy GmbH SkyWind NG PNNL July 2026 listed model; electrical/region options unspecified None
Bonfiglioli ACU 401-03 ACU401 400V class; VEC521R6 None
Vestas V126-3.45/3.6MW HTq IEC S KS WT-1802-00-171146; 2018-07-06 listed certification scope None
ENERCON E-175 EP5 E1 08/2026 technical sheet; documented power and tower options retained {"height_m_by_iec_design_class":{"IEC IIA":[112],"IEC S":[112,132,162]},"note":"Design class claim, not independently verified certification"}
Windey WD164-5000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
ABB ACS800-104-0580-7 3AFE68392454 Rev C None
Nordex N131/3900 published model {"not_all_combinations_available":true,"published_options":"up to 134 m and project and site specific","unit":"m"}
Windey WD77-1500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Goldwind GW 82/1500 Americas English1.5MW brochure; revision unspecified; options not expanded None
Windey WD200-5500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Vestas V163-4.5 MW published model {"not_all_combinations_available":true,"published_options":"98 m (IEC S), 113 m (IEC S) and 126 m (IEC S)","unit":"m"}
Nordex S46 published type None
Nexans TSLF-O 24kV 3x1x240A MP Norwegian catalogue product 10548294 None
Bonfiglioli ACU 401-25 ACU401 400V class; VEC521R6 None
Bonfiglioli ACU 410-09 Frame size 1; R04_0 documented configuration None
Hanjin Industries HJWT-2000-R87-STV KS WT-MLWS-2-0014; 2015.07.22 onshore certification scope {"conditions":"Certificate listed hub options; not selected installation or paired power modes","heights_m":[80.0,85.0]}
Doosan WinDS3000 TC IA D91/H80 KS WT-MLWS-2-0019; 2015.12.31 offshore certification scope None
Bonfiglioli LCVT015 R04_0 exact line-choke type None
Acciona Windpower AW116/3000 published type None
Bonfiglioli ACU 210-09 Frame size 1; R04_0 documented configuration None
Kodair Wind Designs Ltd. KW30 PNNL July 2026 listed model; electrical/region options unspecified None
MHI Vestas Offshore Wind V164-8.4 MW documented configuration None
Bonfiglioli BR 8000/7 R04_0 exact braking resistor type None
Eickhoff Wind Power EBN-5715 Exact disclosed type; manufacturing sites and turbine applications nested None
Vestas V136-3.45 MW (Mode 0) FGW explicitly published configuration; hub options nested None
Bonfiglioli ACU 410-49 Frame size 7; R04_0 documented configuration None
Windey WD172-5500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Windey WD93-1500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Vestas V162-6.0 MW FGW explicitly published configuration; hub options nested None
Bonfiglioli LCVT018 R04_0 exact line-choke type None
Bonfiglioli ACU 410-23 Frame size 4; R04_0 documented configuration None
Vestas V110-2.0 MW published model None
Senvion Wind Technology ReT78.5 Exact disclosed type; manufacturing sites and turbine applications nested None
ABB ACS880-77CC-6880A/5500A-7 690 V, Rev A None
GE Vernova GE 2.7-132 India ALMM as on2026-08-20; tower/power options nested {"options_m":[94,130],"tower_scope":"Tubular steel"}
ENERCON E-138 EP3 E3 08/2026 technical sheet; documented power and tower options retained {"height_m_by_iec_design_class":{"IEC IIA":[81,90,99],"IEC IIIA":[160],"IEC S":[111,131]},"note":"Design class claim, not independently verified certification"}
NGC SPT05A Standardized pitch gearbox type; options retained within model None
Bonfiglioli ACU 401-15 ACU401 400V class; VEC521R6 None
Bonfiglioli ACU 210-22 Frame size 4; R04_0 documented configuration None
Bonfiglioli ACU 401-37 ACU401 400V class; VEC521R6 None
Vestas V47-660/200 kW documented configuration None
Bonfiglioli LCVT034 R04_0 exact line-choke type None
Bonfiglioli ACU 410-51 Frame size 7; R04_0 documented configuration None
ABB ACS800-104LC-0555-7+E205 3AUA0000058400 Rev C None
NGC SYW07 Standardized yaw drive type; options retained within model None
Bonfiglioli BR 160/100 R04_0 exact braking resistor type None
Siemens India 1LG8 456-4 Exact disclosed type; manufacturing sites and turbine applications nested None
ABB ACS880-87LC-4000A/4134A-7 Rev A 2018; single cabinet None
ABB ACS800-104LC-1375-7 3AUA0000058400 Rev C None
Windey WD131-2000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Nordex N54 Mk3 FGW explicitly listed type/revision; hub options nested None
Bonfiglioli LCVT160AL-690 R04_0 exact component type None
Bonfiglioli BR 1330/48 R04_0 exact braking resistor type None
Siemens Gamesa SG 14-222 standard documented model None
Bonfiglioli HLD 110-500/180 R04_0 exact component type None
Nordex N90 / 2500 HS FGW explicitly listed type/revision; hub options nested None
Suzlon S120 DFIG 2.1 MW (50 Hz) India ALMM as on2026-08-20; tower/power options nested {"options_m":[81,90,105,120,140],"tower_scope":"81/90/105/120m tubular steel;120/140m hybrid lattice;140m hybrid concrete"}
Nordex N43 Mk2 FGW explicitly listed type/revision; hub options nested None
Nordex N52 printed 800 kW version None
Bonfiglioli ACU 401-43 ACU401 400V class; VEC521R6 None
Bonfiglioli ACU 610-57 Frame size 8; R04_0 documented configuration None
Daewoo Shipbuilding & Marine Engineering D9.1 KS WT-MLWS-2-0009; 2014.12.23 onshore certification scope None
Bonfiglioli ACU 410-18 Frame size 2; R04_0 documented configuration None
Windey WD121-2000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Goldwind GWH175-7.8MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[105]}
Bonfiglioli LCVT025 R04_0 exact line-choke type None
NGC SYW13 Standardized yaw drive type; options retained within model None
Windey WD245-14000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli HLD 110-500/100 R04_0 exact component type None
Windey WD131-2200 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Nexans TSLF-O 36kV 1x 95A M Norwegian catalogue product ID540453316 None
Windey WD190-5000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli HLD 110-500/16 R04_0 exact component type None
VENSYS Energy AG VENSYS 126 3.8 MW; July 2025 technical sheet {"options":[{"height_m":86.9,"iec_class":"IEC IIA","tower_type":"steel tube"},{"height_m":96.9,"iec_class":"IEC IIA","tower_type":"steel tube"},{"height_m":116.9,"iec_class":"IEC S","tower_type":"segmented steel"},{"height_m":136.9,"iec_class":"IEC IIIA","tower_type":"hybrid concrete/steel"}]}
Bonfiglioli ACU 401-27 ACU401 400V class; VEC521R6 None
Bonfiglioli FTV018B R04_0 exact component type None
GE Vernova 4.2 MW-117m Official product table; 50/60 Hz hub options nested {"options":[{"frequency_hz":50,"heights_m":[95,110]},{"frequency_hz":60,"heights_m":[85,110]}]}
SANY Renewable Energy Co., Ltd. SI-230100 Global English technical table; region/frequency/revision unspecified None
Vestas V150-4.2 MW published model {"not_all_combinations_available":true,"published_options":"105 m (IEC), 123 m (DIBt), 145 m (DIBt), 155 m (IEC) and 166 m (DIBt)","unit":"m"}
ABB ACS800-104LC-0705-7+E205 3AUA0000058400 Rev C None
Windey WD200-7700 Saudi Arabia 60Hz; revision/options unspecified None
Nordex N90 / 2500 LS FGW explicitly listed type/revision; hub options nested None
Siemens Gamesa SG 8.0-167 DD APAC 60 Hz announced 2018 None
Vestas V112-3.225 MW PowerMode FGW explicitly published configuration; hub options nested None
Bonfiglioli ACU 410-55 Frame size 8; R04_0 documented configuration None
Bonfiglioli ACU 210-07 Frame size 1; R04_0 documented configuration None
Bonfiglioli ACU 401-35 ACU401 400V class; VEC521R6 None
Bonfiglioli ACU 410-11 Frame size 1; R04_0 documented configuration None
Daewoo Shipbuilding & Marine Engineering D9.1 KS WT-MLWS-2-0012; 2015.03.03 onshore certification scope None
Nordex N100 / 2500 IEC2A FGW explicitly listed type/revision; hub options nested None
Envision Energy India EN76.5AV2 Exact disclosed type; manufacturing sites and turbine applications nested None
Bonfiglioli ACU 410-45 Frame size 7; R04_0 documented configuration None
Vestas V29 FGW explicitly published configuration; hub options nested None
Siemens Gamesa SG 5.2-165 USA None
Vestas V136-4.2 MW published model {"not_all_combinations_available":true,"published_options":"105 m (IEC), 112 m (IEC/DIBt), 117 m (IEC), 149 m (DIBt) and 166 m (DIBt)","unit":"m"}
Nordex S70 published type None
Windey WD147-4500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Windey WD172-6250 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
CRRC Zhuzhou Times New Material Technology 2.XMW-64.5 Published OEM blade table 2021-07-22; wind class S; root pitch-circle 2.3 m None
ABB ALCL-15LC-7 3AUA0000058400 Rev C None
Bonfiglioli LCVT180 R04_0 exact line-choke type None
Vestas V150-4.5 MW published model {"not_all_combinations_available":true,"published_options":"90 m (IEC IIIB) and 105 m (IEC IIIB)","unit":"m"}
NGC SMG282CDT175-0136 Exact disclosed type; manufacturing sites and turbine applications nested None
HARTING 09340062601 OEM part 09340062601; UK public specification None
Vestas V117-3.3 MW FGW explicitly published configuration; hub options nested None
HARTING 09200042711 OEM part 09200042711; UK public specification None
Nexans TSLF-O 24kV 3x1x630A MP Norwegian catalogue product 10558142 None
LM Wind Power LM 47.6 P2 Exact type named in dated DNV register None
Windey WD164-4800 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli LCVT410AL-690 R04_0 exact component type None
Vestas V126-3.3 MW FGW explicitly published configuration; hub options nested None
ABB ACS880-77LC-3372A/3136A-7 Rev A 2018; twin cabinet None
Flender PDAJ3738 Exact disclosed type; manufacturing sites and turbine applications nested None
Bonfiglioli 713 TW 700TW model; application-specific peak ratings retained together None
Windey WD82-1500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Southern Wind Farms GWL 225 India ALMM as on2026-08-20; tower/power options nested {"options_m":[48.7],"tower_scope":"Folded bolted tubular steel"}
SD Wind Energy, Ltd. SD12 OEM published configuration; electrical and tower options nested {"conditions":"OEM tower options, not a Cartesian configuration expansion","heights_m":[15,20]}
Bergey Windpower Company Excel 15 PNNL July 2026 listed model; electrical/region options unspecified None
Nordex N155 published type None
Dalian Huarui Special Transmission Equipment CWTG3300/145-110-50 Exact disclosed type; manufacturing sites and turbine applications nested None
Winergy PZFG 2535 Two-stage HybridDrive; historical brochure configuration None
Windey WD156-3600 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Nordex N163/7000 FGW explicitly listed type/revision; hub options nested None
Acciona Windpower AW109/3000 published type None
NGC SPT11A Standardized pitch gearbox type; options retained within model None
Vestas V112-3.45 MW PowerMode FGW explicitly published configuration; hub options nested None
Windey WD185-6250 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Windey WD156-3000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli ACU 401-05 ACU401 400V class; VEC521R6 None
Windey WD147-4800 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
LM Wind Power LM75.7 P2 Gen B Exact disclosed type; manufacturing sites and turbine applications nested None
Bonfiglioli LCVT320AL-690 R04_0 exact component type None
Bonfiglioli ACU 201-22 ACU201 230V class; VEC521R6 None
Vestas V112-3.3 MW FGW explicitly published configuration; hub options nested None
SANY Renewable Energy Co., Ltd. SI-18342 Global English technical table; region/frequency/revision unspecified None
Goldwind GWH170-7.2MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[105]}
WEG Industries India AGW 147/4.2 India ALMM as on2026-08-20; tower/power options nested {"options_m":[120],"tower_scope":"Tubular steel"}
Inox Wind DF/2000/113 India ALMM as on2026-08-20; tower/power options nested {"options_m":[92],"tower_scope":"Tubular steel"}
Nordex AW140/3000 published type None
Bonfiglioli FTV401A R04_0 exact component type None
Windey WD245-15000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
SANY Renewable Energy Co., Ltd. SI-20480 Global English technical table; region/frequency/revision unspecified None
Windey WD156-5200 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Doosan WinDS5500/140 KS WT-2302-00-170714; 2023.03.10 offshore certification scope None
Bonfiglioli ACU 410-43 Frame size 7; R04_0 documented configuration None
Bonfiglioli ACU 401-29 ACU401 400V class; VEC521R6 None
Flender JFWA-500SS-04A Exact disclosed type; manufacturing sites and turbine applications nested None
Unison U120 KS WT-2102-00-170972; 2021.07.21 onshore certification scope None
Envision Energy India EN-182-5.0 - 50 Hz India ALMM as on2026-08-20; tower/power options nested {"options_m":[130,140],"tower_scope":"Tubular steel"}
Senvion Wind Technology 4.2M160 India ALMM as on2026-08-20; tower/power options nested {"options_m":[140],"tower_scope":"Tubular steel"}
Bonfiglioli HLD 110-500/8 R04_0 exact component type None
Nordex S50 FGW explicitly listed type/revision; hub options nested None
Windey WD125-2500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli ACU 201-05 ACU201 230V class; VEC521R6 None
Vestas V136-4.0MW FGW explicitly published configuration; hub options nested None
Bonfiglioli ACU 210-19 Frame size 3; R04_0 documented configuration None
Vestas V39/500 FGW explicitly published configuration; hub options nested None
ABB ACS800-67LC-1375/1125-7 3AUA0000058400 Rev C None
Windey WD140-3000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli ACU 201-11 ACU201 230V class; VEC521R6 None
CRRC Zhuzhou Times New Material Technology 4.XMW-86 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m None
Windey WD164-3000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Windey WD200-6660 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Winergy PZFG 2456 Two-stage HybridDrive; historical brochure configuration None
Windey WD220-10000 OEM case-study model; revision/options unspecified None
HARTING 19200031440 OEM part 19200031440; UK public specification None
Bonfiglioli 714 TW 700TW model; application-specific peak ratings retained together None
HARTING 19340060421 OEM part 19340060421; UK public specification None
Inox Wind SR71-V2 with T-Bolts Exact disclosed type; manufacturing sites and turbine applications nested None
Nexans TSLF-O 36kV 1x400A Norwegian catalogue product 10540622 None
Siemens Gamesa SG 7.0-170 standard documented model {"site_specific":true,"values_m":[110.5,115,135,155,165,181,185]}
Bonfiglioli ACU 201-19 ACU201 230V class; VEC521R6 None
Nordex S77 published type None
Nexans TSLF-O 24kV 1x150A M Norwegian catalogue product ID540453319 None
Windey WD190-4800 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Pioneer Wincon Energy Systems 750/49 HT24 IIIA India ALMM as on2026-08-20; tower/power options nested {"options_m":[61.1,75.3],"tower_scope":"Lattice steel"}
Bonfiglioli LCVT550AL-525 R04_0 exact component type None
Bonfiglioli BR 471/136 R04_0 exact braking resistor type None
Bonfiglioli LCVT135 R04_0 exact line-choke type None
Bonfiglioli ACU 201-07 ACU201 230V class; VEC521R6 None
Mingyang SCB11-8000/35 Exact type named in dated DNV register None
SD Wind Energy, Ltd. SD3 OEM published configuration; electrical and tower options nested {"conditions":"OEM tower options, not a Cartesian configuration expansion","heights_m":[6,9]}
Goldwind GW155-4.5MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[95,110,140]}
Bonfiglioli ACU 410-39 Frame size 6; R04_0 documented configuration None
Bonfiglioli ACU 210-05 Frame size 1; R04_0 documented configuration None
Goldwind GWH182-7.5MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
Hyundai Heavy Industries HQ1650 KS WT-MLWS-2-0008; 2014.12.23 onshore certification scope None
Nordex N60 published type None
Bonfiglioli ACU 410-61 Frame size 8; R04_0 documented configuration None
Bonfiglioli LCVT440AL-525 R04_0 exact component type None
Suzhou Hopewind Electric HWDFM0693150 Exact disclosed type; manufacturing sites and turbine applications nested None
HARTING 19200101440 OEM part 19200101440; UK public specification None
Nordex AW132/3000 published type None
Windey WD185-6660 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
SANY Renewable Energy Co., Ltd. SI-172625 Global English technical table; region/frequency/revision unspecified None
Delijia Transmission Technology (Jiangsu) WE4500S-01 Exact disclosed type; manufacturing sites and turbine applications nested None
Nordex N163/6800 FGW explicitly listed type/revision; hub options nested None
GE Vernova 2.8 MW-127m standard documented model {"60_Hz":[89,114]}
ABB ACS880-87LC-8000A/8268A-7 Rev A 2018; twin cabinet None
Bonfiglioli ACU 401-18 ACU401 400V class; VEC521R6 None
Vestas V42 FGW explicitly published configuration; hub options nested None
Bonfiglioli ACU 410-12 Frame size 1; R04_0 documented configuration None
Siemens Gamesa B81 standard documented model None
HARTING 19200161440 OEM part 19200161440; UK public specification None
Bonfiglioli ACU 401-45 ACU401 400V class; VEC521R6 None
Windey WD225-9000 OEM case-study model; revision/options unspecified None
Vestas V126-3.3 MW mit 3.45 Power Mode FGW explicitly published configuration; hub options nested None
Nexans TSLF-O 24kV 3x1x400A MP Norwegian catalogue product 10557077 None
Adani New Industries MWL78.6 Exact disclosed type; manufacturing sites and turbine applications nested None
Adani New Industries WD147-3000 India ALMM as on2026-08-20; tower/power options nested {"options_m":[100],"tower_scope":"Tubular steel"}
GE Vernova 3.4 MW-140m standard documented model {"60_Hz":[81]}
NGC SPT01A Standardized pitch gearbox type; options retained within model None
Envision Energy EN89 VL Exact disclosed type; manufacturing sites and turbine applications nested None
ABB ACS880-77LC-1686A/1568A-7 Rev A 2018; single cabinet None
Bonfiglioli ACU 410-27 Frame size 5; R04_0 documented configuration None
Nordex N43 published type None
Bonfiglioli HLD 110-500/42 R04_0 exact component type None
Nexans TSLF-O 36kV 1x240A M Norwegian catalogue product ID540453313 None
Bonfiglioli ACU 201-15 ACU201 230V class; VEC521R6 None
Doosan WinDS3300/134 Onshore KS WT-2104-00-180674; 2021.10.15 onshore certification scope None
Bonfiglioli LCVT690AL-400 R04_0 exact component type None
Bonfiglioli ACU 410-51 Frame size 8; R04_0 documented configuration None
ABB ACS880-77LC-5006A/4656A-7 Rev A 2018; twin cabinet None
ABB ACS800-104-1160-7 3AFE68392454 Rev C None
HARTING 09150006203 OEM part 09150006203; UK public specification None
Bonfiglioli ACU 401-19 ACU401 400V class; VEC521R6 None
ABB NEXA-21 extension unit None
Inox Wind WBSR146-3.0 Exact disclosed type; manufacturing sites and turbine applications nested None
Nexans TSLF-O 36kV 1x630A Norwegian catalogue product 10540623 None
Windey WD172-6000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli LCVS015 R04_0 exact line-choke type None
Sinomatech Wind Power Blade SI90.2 Exact disclosed type; manufacturing sites and turbine applications nested None
Bonfiglioli HLD 110-500/75 R04_0 exact component type None
Venwind Refex Power GWH182-5.3 India ALMM as on2026-08-20; tower/power options nested {"options_m":[110,130],"tower_scope":"Conical steel"}
Bonfiglioli ACU 401-31 ACU401 400V class; VEC521R6 None
Nordex S46/600kW FGW explicitly listed type/revision; hub options nested None
Bergey Windpower Company Powersync 25 OEM published configuration; electrical and tower options nested None
Nexans TSLF-O 36kV 1x630A M Norwegian catalogue product ID540453311 None
Bonfiglioli LCVT250AL-690 R04_0 exact component type None
Senvion Wind Technology 2.3M120 India ALMM as on2026-08-20; tower/power options nested {"options_m":[120],"tower_scope":"Tubular steel"}
ABB ACS880-77LC-1720A/1600A-7 Rev A 2018; twin cabinet None
Nexans TSLF-O 24kV 1x630A M Norwegian catalogue product ID540453317 None
Bonfiglioli 711 TW 700TW model; application-specific peak ratings retained together None
Acciona Windpower AW70/1300 published type None
Kodair Wind Designs Ltd. KW20 PNNL July 2026 listed model; electrical/region options unspecified None
Nordex N62 published type None
ABB ACS880-87LC-6604A/6144A-7 Rev A 2018; twin cabinet None
Senvion Wind Technology 3.1M130 India ALMM as on2026-08-20; tower/power options nested {"options_m":[130,140],"tower_scope":"Tubular steel"}
CRRC Zhuzhou Times New Material Technology 4.XMW-80.5 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m None
Bonfiglioli ACU 210-18 Frame size 3; R04_0 documented configuration None
Bonfiglioli LCVT090 R04_0 exact line-choke type None
HARTING 09330006202 OEM part 09330006202; UK public specification None
Windey WD190-5200 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Siva Wind Turbine India SIVA 225/40 India ALMM as on2026-08-20; tower/power options nested {"options_m":[50],"tower_scope":"Four-leg lattice steel"}
LM Wind Power LM76.5P Exact disclosed type; manufacturing sites and turbine applications nested None
Windey WD190-5500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Vestas V15 FGW explicitly published configuration; hub options nested None
CRRC Zhuzhou Times New Material Technology 4.XMW-78 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m None
Bonfiglioli LCVT010 R04_0 exact line-choke type None
CRRC Zhuzhou Times New Material Technology 2.0MW-59.5 Published OEM blade table 2021-07-22; wind class S; root pitch-circle 2.3 m None
Windey WD190-4500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli 706 TW 700TW model; application-specific peak ratings retained together None
HARTING 09451151104 OEM part 09451151104; UK public specification None
Windey WD172-4200 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli ACU 510-61 Frame size 8; R04_0 documented configuration None
NGC CMG425AFF74-0212 Exact disclosed type; manufacturing sites and turbine applications nested None
Goldwind GW 70/1500 Americas English1.5MW brochure; revision unspecified; options not expanded None
Hyundai Heavy Industries HQ2000-DF2000/86/2/60 KS WT-MLWS-2-0006; 2014.11.24 onshore certification scope None
Bonfiglioli FTV630A R04_0 exact component type None
Windey WD195-7000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli LCVS010 R04_0 exact line-choke type None
Windey WD245-13000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
ENERCON E-175 EP5 E2 08/2026 technical sheet; documented power and tower options retained {"height_m_by_iec_design_class":{"IEC IIA":[112],"IEC IIIA":[140],"IEC S":[112,132,140,162,175]},"note":"Design class claim, not independently verified certification"}
Vestas V136-3.6MW FGW explicitly published configuration; hub options nested None
Nexans TSLF-O 24kV 3x1x150A MP Norwegian catalogue product 10548293 None
Bonfiglioli ACU 510-55 Frame size 8; R04_0 documented configuration None
Envision Energy WE7200Y Exact disclosed type; manufacturing sites and turbine applications nested None
Siemens Gamesa SG 3.4-145 India {"site_specific":true,"values_m":[127.5,133.5,146]}
HARTING 09150043113 OEM part 09150043113; UK public specification None
Envision Energy India EN-156/3.3 India ALMM as on2026-08-20; tower/power options nested {"options_m":[120,123,140,143],"tower_scope":"Tubular steel"}
CRRC Zhuzhou Times New Material Technology 5.XMW-91 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 3.2 m None
Sinoma Wind Power Blade YD80.5 Exact disclosed type; manufacturing sites and turbine applications nested None
ABB ACS800-204LC-0575-7+E205 3AUA0000058400 Rev C None
Bonfiglioli ACU 610-53 Frame size 8; R04_0 documented configuration None
ABB ACS800-67LC-1595/0865-7 3AUA0000058400 Rev C None
VENSYS Energy AG VENSYS 115 4.1 MW; July 2025 technical sheet {"options":[{"height_m":67.5,"iec_class":"IEC IIA","tower_type":"steel tube"},{"height_m":72.5,"iec_class":"IEC IIA","tower_type":"steel tube"},{"height_m":92.5,"iec_class":"IEC IIA","tower_type":"steel tube"},{"height_m":119,"iec_class":"IEC IIIA","tower_type":"segmented steel"}]}
Bonfiglioli ACU 410-22 Frame size 3; R04_0 documented configuration None
HARTING 09210153101 OEM part 09210153101; UK public specification None
Bonfiglioli ACU 401-09 ACU401 400V class; VEC521R6 None
Windey WD200-9000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Nordex N133/4.8 published model {"not_all_combinations_available":true,"published_options":"project and site-specific","unit":"m"}
NGC SYW09 Standardized yaw drive type; options retained within model None
Vestas V52-850kW / Mode 104,2dB FGW explicitly published configuration; hub options nested None
LM Wind Power LM78.3P (Gen C) Exact disclosed type; manufacturing sites and turbine applications nested None
Pioneer Wincon Energy Systems HT24 Exact disclosed type; manufacturing sites and turbine applications nested None
HARTING 09200163001 OEM part 09200163001; UK public specification None
Vestas V80-2.0MW / Mode 105.1 dB FGW explicitly published configuration; hub options nested None
Eveready Diversified Products (Pty) Ltd. Kestrel e400nb PNNL July 2026 listed model; electrical/region options unspecified None
Bonfiglioli ACU 210-03 Frame size 1; R04_0 documented configuration None
ABB ALCL-24LC-7 3AUA0000058400 Rev C None
Bonfiglioli ACU 410-01 Frame size 1; R04_0 documented configuration None
Siemens Gamesa SG 11-200 standard documented model None
Bonfiglioli ACU 201-01 ACU201 230V class; VEC521R6 None
Nordex N131/3600 published model {"not_all_combinations_available":true,"published_options":"up to 134 m, project and site-specific","unit":"m"}
CRRC Zhuzhou Times New Material Technology 6.XMW-91 Published OEM blade table 2022-03-03; wind class SB; root pitch-circle 3.2 m None
Envision Energy WE3600Y Exact disclosed type; manufacturing sites and turbine applications nested None
SD Wind Energy, Ltd. SD3EX OEM published configuration; electrical and tower options nested None
Windey WD140-2500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
HARTING 09200103001 OEM part 09200103001; UK public specification None
Windey WD156-4500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Nordex N163/5.X published model {"not_all_combinations_available":true,"published_options":"up to 164 m, project – and site-specific","unit":"m"}
Nexans TSLF-O 24kV 1x50A Norwegian catalogue product 10581270 None
Doosan WinDS3000 TC IA D91/H80 KS WT-MLWS-2-0016; 2015.10.14 onshore certification scope None
Bonfiglioli LCVT470AL-525 R04_0 exact component type None
Vestas V66 VCS 1.75MW - 106.5dB FGW explicitly published configuration; hub options nested None
Unison U50 KS WT-MLWS-2-0022; 2016.09.30 onshore certification scope None
Nordex N117/3600 published model {"not_all_combinations_available":true,"published_options":"up to 134 m, project and site-specific","unit":"m"}
Bonfiglioli 712 TW 700TW model; application-specific peak ratings retained together None
Windey WD200-7000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Siemens Gamesa SG 14-236 standard documented model None
Bonfiglioli ACU 610-51 Frame size 8; R04_0 documented configuration None
SANY Renewable Energy Co., Ltd. SI-19350 Global English technical table; region/frequency/revision unspecified None
Acciona Windpower AW100/3000 published type None
NGC SYW05 Standardized yaw drive type; options retained within model None
Nexans TSLF-O 24kV 3x1x50A MP Norwegian catalogue product 10548290 None
Nordex N54 Mk2 FGW explicitly listed type/revision; hub options nested None
Goldwind GWH182-5.3MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
Vestas V27 FGW explicitly published configuration; hub options nested None
Nexans TSLF-O 24kV 1x400A Norwegian catalogue product 10224391 None
Bonfiglioli 716 TW 700TW model; application-specific peak ratings retained together None
Bonfiglioli FTV040B R04_0 exact component type None
Bonfiglioli ACU 410-53 Frame size 8; R04_0 documented configuration None
Nordex N175/6.X published model {"not_all_combinations_available":true,"published_options":"Up to 179m, project and site-specific","unit":"m"}
Windey WD156-5500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli LCVT060 R04_0 exact line-choke type None
Bonfiglioli ACU 401-01 ACU401 400V class; VEC521R6 None
Bonfiglioli BR 213/300 R04_0 exact braking resistor type None
Acciona Windpower AW70/1500 published type None
Bonfiglioli ACU 410-05 Frame size 1; R04_0 documented configuration None
Siemens Gamesa SG 15-236 standard documented model None
NGC SMG282ADT113-0209 Exact disclosed type; manufacturing sites and turbine applications nested None
Vestas V80-2.0MW GridStreamer FGW explicitly published configuration; hub options nested None
Windey WD107-2500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
ABB ACS800-67LC-1375/0575-7 3AUA0000058400 Rev C None
Bonfiglioli ACU 410-35 Frame size 6; R04_0 documented configuration None
Nordex N82 published type None
ENERCON E-82 E2 OEM named model; optional OM-YO-01 retained within record {"conditions":"08/2019 tower options; no universal tower/wind-class compatibility assertion","values_m":[78,84,85,98,108,138]}
ABB ALCL-25LC-7 3AUA0000058400 Rev C None
Vestas V66/1,65MW RCC FGW explicitly published configuration; hub options nested None
NGC SPT13A Standardized pitch gearbox type; options retained within model None
Bonfiglioli HLD 110-500/250 R04_0 exact component type None
Bonfiglioli LCVT115 R04_0 exact line-choke type None
ABB NETA-21 remote monitoring tool None
Vestas V136-4.5 MW published model {"not_all_combinations_available":true,"published_options":"112 m (IEC IIB)","unit":"m"}
Siemens Gamesa SG 3.4-132 standard documented model {"site_specific":true,"values_m":[84,97,101.5,114,134]}
ELIN Motoren MRM-063 Z06 Exact disclosed type; manufacturing sites and turbine applications nested None
Doosan WinDS3000 TC IIA D100/H80 KS WT-MLWS-2-0018; 2015.12.30 offshore certification scope None
NGC SPT09A Standardized pitch gearbox type; options retained within model None
Nexans TSLF-O 36kV 1x400A M Norwegian catalogue product ID540453312 None
ABB ACS880-87LC-3302A/3072A-7 Rev A 2018; single cabinet None
Bonfiglioli ACU 410-25 Frame size 4; R04_0 documented configuration None
Jiangsu Delijia Drive Technology WE7000G Exact disclosed type; manufacturing sites and turbine applications nested None
Xi’an Chen’an Electric YD3600FDJ-3 Exact disclosed type; manufacturing sites and turbine applications nested None
Vestas V90-2.0MW FGW explicitly published configuration; hub options nested None
Nexans TSLF-O 24kV 3x1x95A MP Norwegian catalogue product 10548292 None
Vestas V150-5.6 MW FGW explicitly published configuration; hub options nested None
CRRC Zhuzhou Times New Material Technology 3.XMW-71.5 Published OEM blade table 2022-03-03; wind class SC; root pitch-circle 2.8 m None
Vestas V155-3.6 MW India ALMM as on2026-08-20; tower/power options nested {"options_m":[102.5,105,118,120,136,137],"tower_scope":"Conical steel"}
Doosan WinDS3000 TC IIA D100/H80 KS WT-MLWS-2-0011; 2015.02.11 onshore certification scope None
NGC SPT03A Standardized pitch gearbox type; options retained within model None
MHI Vestas Offshore Wind V164-9.5 MW documented configuration None
Nexans TSLF-O 36kV 1x240A Norwegian catalogue product 10540621 None
Unison U151 KS WT-2204-00-190357; 2022.12.29 offshore certification scope None
Bonfiglioli ACU 410-37 Frame size 6; R04_0 documented configuration None
HARTING 09150006103 OEM part 09150006103; UK public specification None
Nordex N100 printed 3300 kW version None
Hunan Xiangtan Electric Power YD3600FDJ-A (YJ339B) Exact disclosed type; manufacturing sites and turbine applications nested None
Goldwind GW165-5.6MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
Bonfiglioli ACU 401-11 ACU401 400V class; VEC521R6 None
Nordex N50 published type None
CRRC Zhuzhou Times New Material Technology 3.XMW-78 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m None
Windey WD172-5000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Vestas V44-600kW FGW explicitly published configuration; hub options nested None
Bonfiglioli LCVT004 R04_0 exact line-choke type None
Unison U93 KS WT-MLWS-2-0013; 2015.06.04 onshore certification scope {"conditions":"Certificate listed hub options; not selected installation or paired power modes","heights_m":[80.0,100.0]}
HARTING 09330006105 OEM part 09330006105; UK public specification None
Bonfiglioli LCVT360AL-690 R04_0 exact component type None
Nordex N149/5.X published model {"not_all_combinations_available":true,"published_options":"up to 164 m, project- and sitespecific","unit":"m"}
ABB ACS880-87LC-1686A/1568A-7 Rev A 2018; single cabinet None
Goldwind GW165-6.0MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
Goldwind GW136-4.2MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[100]}
Vestas V47-660 kW documented configuration None
CRRC Zhuzhou Times New Material Technology 3.XMW-80.5 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m None
Bonfiglioli ACU 410-21 Frame size 3; R04_0 documented configuration None
Eocycle Technologies, Inc. EOX S-16 PNNL July 2026 listed model; electrical/region options unspecified None
Vestas V17 FGW explicitly published configuration; hub options nested None
Dalian Huarui Special Transmission Equipment CWTG750P/57-67-50 Exact disclosed type; manufacturing sites and turbine applications nested None
Bonfiglioli HLD 110-500/30 R04_0 exact component type None
Siemens Gamesa SG 3.2-129 USA {"site_specific":true,"values_m":[87,119]}
Envision Energy EN-182 6 MW; 182 m rotor; 120 m hub; Mudarra October 2026 proposal {"options_m":[120.0],"scope":"Explicit Mudarra proposal only"}
CRRC Zhuzhou Times New Material Technology 4.XMW-72.5 Published OEM blade table 2022-03-03; wind class S; root pitch-circle 3.2 m None
Bonfiglioli ACU 401-07 ACU401 400V class; VEC521R6 None
Siemens Gamesa SG 4.3-140 standard documented model {"site_specific":true,"values_m":[105]}
Envision Energy EN-182 7 MW; 182 m rotor; 120 m hub; Mudarra October 2026 proposal {"options_m":[120.0],"scope":"Explicit Mudarra proposal only"}
SANY (Shaoshan) Wind Power Equipment FB82036 Exact disclosed type; manufacturing sites and turbine applications nested None
Bonfiglioli ACU 410-47 Frame size 7; R04_0 documented configuration None
CRRC Zhuzhou Times New Material Technology 2.XMW-64.0 Published OEM blade table 2021-07-22; wind class S; root pitch-circle 2.3 m None
SANY Renewable Energy Co., Ltd. SI-18572 Global English technical table; region/frequency/revision unspecified None
Windey WD107-2000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Goldwind GW 77/1500 Americas English1.5MW brochure; revision unspecified; options not expanded None
Hitachi DTE 3150/72.5 Exact type named in dated DNV register None
Bonfiglioli ACU 201-03 ACU201 230V class; VEC521R6 None
Bonfiglioli ACU 401-49 ACU401 400V class; VEC521R6 None
Windey WD172-5200 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
CRRC Zhuzhou Times New Material Technology 4.XMW-84 Published OEM blade table 2022-03-03; wind class SC; root pitch-circle 2.8 m None
HARTING 09120053101 OEM part 09120053101; UK public specification None
Bonfiglioli ACU 510-57 Frame size 8; R04_0 documented configuration None
Bonfiglioli BR 696/92 R04_0 exact braking resistor type None
Windey WD164-3300 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Nexans TSLF-O 24kV 3x1x400A 16 mm rør MP Norwegian catalogue product 10561867 None
GE Vernova 6.0 MW-164m standard documented model {"50_Hz":[166,167]}
Windey WD164-4000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
ABB ACS800-104LC-2035-7 3AUA0000058400 Rev C None
Vestas V126-3.6 MW HTq (Mode PO1) FGW explicitly published configuration; hub options nested None
Windey WD225-8000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Tianjin CRRC Wind Turbine Blade Engineering TMT71.5E Exact disclosed type; manufacturing sites and turbine applications nested None
Goldwind GWH204-10.5MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[120]}
NGC SMG322BDT177-0181 Exact disclosed type; manufacturing sites and turbine applications nested None
Goldwind GWH182-6.2MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
Bonfiglioli LCVS018 R04_0 exact line-choke type None
VENSYS Energy AG VENSYS 175 7.8 MW; August 2025 technical sheet {"options":[{"height_m":145,"iec_class":"IEC S","tower_type":"segmented steel"},{"height_m":160,"iec_class":"IEC S","tower_type":"hybrid concrete/steel"}]}
Nordex N77 / 1500 FGW explicitly listed type/revision; hub options nested None
ABB ACS800-104-0770-7 3AFE68392454 Rev C None
Bonfiglioli ACU 210-11 Frame size 1; R04_0 documented configuration None
Goldwind GW136-4.8MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[100]}
Vestas V90-2.0MW GridStreamer TM FGW explicitly published configuration; hub options nested None
Bonfiglioli ACU 401-39 ACU401 400V class; VEC521R6 None
Bonfiglioli LCVT075 R04_0 exact line-choke type None
ABB ACS800-67LC-1075/0575-7 3AUA0000058400 Rev C None
Mingyang SCLB11-5500/38.5 Exact type named in dated DNV register None
HARTING 09340062701 OEM part 09340062701; UK public specification None
Nordex S46/750kW FGW explicitly listed type/revision; hub options nested None
NGC SYW01 Standardized yaw drive type; options retained within model None
Nanjing Turbine & Electric Machinery Changfeng New Energy GWH V12-TFY Exact disclosed type; manufacturing sites and turbine applications nested None
Goldwind GW 121/2500 Americas English brochure; printed revision unspecified; options not expanded None
Windey WD103-2000 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli ACU 210-15 Frame size 2; R04_0 documented configuration None
Vestas V126-3.45 MW published model {"not_all_combinations_available":true,"published_options":"87 m (IEC IIA/IIB), 117 m (IEC IIA/DIBt S/IIB), 137 m (IEC IIIA/DIBt S), 147 m (IEC IIIA), 149 m (DIBt S) and 166 m (DIBt S)","unit":"m"}
Pioneer Wincon Energy Systems 750/57 PW28 IIIA India ALMM as on2026-08-20; tower/power options nested {"options_m":[75,90],"tower_scope":"Four-leg lattice steel with tower-top adapter"}
SANY Renewable Energy Co., Ltd. SI-19342 Global English technical table; region/frequency/revision unspecified None
Vestas V182-7.2 MW published model {"not_all_combinations_available":true,"published_options":"109 m (IEC S), 170 m (IEC S), 170 m (DiBt)","unit":"m"}
ABB ACS880-77LC-860A/800A-7 Rev A 2018; single cabinet None
GE Vernova 3.8 MW-154m standard documented model {"50_Hz":[135],"60_Hz":[98,116]}
Esteyco WHEEL PLOCAN 6 MW pilot; environmental design 2025-06-27 None
Goldwind GW 100/2500 Americas English brochure; printed revision unspecified; options not expanded None
Vestas V112-3.0 MW FGW explicitly published configuration; hub options nested None
Windey WD147-2500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli LCVT006 R04_0 exact line-choke type None
Windey WD172-4500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Windey WD156-4800 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli ACU 410-07 Frame size 1; R04_0 documented configuration None
Goldwind GW165-5.2MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
Windey WD88-1500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Bonfiglioli HLD 110-500/55 R04_0 exact component type None
Unison U136 89H/84.3H KS WT-2301-00-222411; 2023.02.28 onshore certification scope {"conditions":"Certificate listed hub options; not selected installation or paired power modes","heights_m":[84.3,89.0]}
CG Power and Industrial Solutions SG055D06 Exact disclosed type; manufacturing sites and turbine applications nested None
Bonfiglioli ACU 510-59 Frame size 8; R04_0 documented configuration None
Unison U113 KS WT-MLWS-1-0015; 2015.09.11 onshore certification scope {"conditions":"Certificate listed hub options; not selected installation or paired power modes","heights_m":[83.5,100.0]}
SD Wind Energy, Ltd. SD6+ OEM published configuration; electrical and tower options nested {"conditions":"OEM tower options, not a Cartesian configuration expansion","heights_m":[9,15,20]}
ABB ACS880-87LC-2503A/2328A-7 Rev A 2018; single cabinet None
NGC SPT07A Standardized pitch gearbox type; options retained within model None
Bonfiglioli ACU 401-21 ACU401 400V class; VEC521R6 None
Nordex N54 published type None
Goldwind GW 109/2500 Americas English brochure; printed revision unspecified; options not expanded None
NGC CMG262ADT159-0035 Exact disclosed type; manufacturing sites and turbine applications nested None
Pioneer Wincon Energy Systems PW28 Exact disclosed type; manufacturing sites and turbine applications nested None
Bonfiglioli ACU 510-51 Frame size 8; R04_0 documented configuration None
Bonfiglioli ACU 410-59 Frame size 8; R04_0 documented configuration None
Windey WD103-2500 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Nordex N54 Mk1 FGW explicitly listed type/revision; hub options nested None
VENSYS Energy AG VENSYS 82 1.85 MW; July 2025 technical sheet {"options":[{"height_m":58.7,"iec_class":"IEC IIA","tower_type":"steel tube"},{"height_m":83.7,"iec_class":"IEC IIA","tower_type":"steel tube"},{"height_m":100,"iec_class":"IEC IIA","tower_type":"steel tube"}]}
ZF Wind Power EF0953A Exact disclosed type; manufacturing sites and turbine applications nested None
SANY Renewable Energy Co., Ltd. SI-19580 Global English technical table; region/frequency/revision unspecified None
Bonfiglioli ACU 610-59 Frame size 8; R04_0 documented configuration None
Inox Wind DF/3000/145 India ALMM as on2026-08-20; tower/power options nested {"options_m":[100,122.5,140],"tower_scope":"Tubular steel"}
Acciona S.A. AW60/1300 published type None
CRRC Zhuzhou Times New Material Technology 2.XMW-71.5 Published OEM blade table 2021-07-22; wind class S; root pitch-circle 2.8 m None
Hyundai Heavy Industries HQ1650-A KS WT-MLWS-1-0020; 2016.02.11 onshore certification scope None
VENSYS Energy AG VENSYS 70 2.1 MW; July 2025 technical sheet {"options":[{"height_m":57.4,"iec_class":"IEC IIA","tower_type":"steel tube"},{"height_m":64.4,"iec_class":"IEC IIA","tower_type":"steel tube"},{"height_m":84.4,"iec_class":"IEC IIA","tower_type":"steel tube"}]}
Nordex N29/250 published type None
HARTING 09330006205 OEM part 09330006205; UK public specification None
NGC SYW11 Standardized yaw drive type; options retained within model None
Bonfiglioli ACU 401-33 ACU401 400V class; VEC521R6 None
Nordex N117 published type None
Bonfiglioli LCVT050 R04_0 exact line-choke type None
Beijing Sany Smart Electrical Machine YSK37-04 Exact disclosed type; manufacturing sites and turbine applications nested None
Vestas V162-7.2 MW published model {"not_all_combinations_available":true,"published_options":"119 m (IEC S/DIBt S), 138 m (IEC S), 166 m (IEC S) and 169 m (DIBt S)","unit":"m"}
Bonfiglioli ACU 410-57 Frame size 8; R04_0 documented configuration None
Windey WD172-4800 2022-6 English brochure; PDF creation metadata2022-06-30; formal revision unspecified None
Goldwind GWH182-8.0MW Explicit published column; site-specific options nested {"conditions":"Listed options or site-specific; no chosen project hub height","heights_m":[110]}
CRRC Zhuzhou Times New Material Technology 3.XMW-82 Published OEM blade table 2022-03-03; wind class ⅢC; root pitch-circle 2.8 m None
CRRC Zhuzhou Times New Material Technology 3.XMW-76 Published OEM blade table 2022-03-03; wind class SB; root pitch-circle 2.5 m None
Bonfiglioli ACU 410-13 Frame size 2; R04_0 documented configuration None
ABB APBU-44 3AFE68392454 Rev C None
ABB ACS800-67-0480/0770-7 3AFE68392454 Rev C None
HARTING 09150033101 OEM part 09150033101; UK public specification None
Offshore foundations and water-depth ranges; unknown remains unknown:
name foundation_type water_depth_min_m water_depth_max_m
Ulladulla Offshore Wind Farm None NaN NaN
Blue Mackerel North Off Shore Wind Farm None NaN NaN
Greater Changhua 2a jacket NaN NaN
Southern Winds Offshore Wind None NaN NaN
Hywind Scotland Pilot Park (Hywind 2) Demonstrator None 95.0 120.0
Kincardine WindFloat T semi-submersible 60.0 80.0
Greater Changhua 1 jacket NaN NaN
WindFloat Atlantic WindFloat T semi-submersible 100.0 100.0
Hywind Tampen None 260.0 300.0
WHEEL PLOCAN prototype WHEEL two-tank floating substructure 90.0 90.0
Star of the South Wind Farm None NaN NaN
Eastern Rise Offshore Wind None NaN NaN
High Sea Wind Farm None NaN NaN
Baltic Eagle Offshore Wind None NaN NaN
Great Eastern Offshore Wind - KCI None NaN NaN
Spinifex Offshore Wind Farm None NaN NaN
Eden Offshore Wind Farm None NaN NaN
Gippsland Dawn Offshore Wind Project None NaN NaN
Illawarra Offshore Wind Farm None NaN NaN
Bass Offshore Wind Energy Project None NaN NaN
South Pacific Offshore Wind Project None NaN NaN
Greater Southern Offshore Wind - KCI None NaN NaN
Novocastrian Offshore Wind Farm None NaN NaN
Hunter Central Coast Offshore Energy (Wind) None NaN NaN
Orsted Gippsland 01 Windfarm None NaN NaN
Published mixed-fleet models (counts can remain unknown):
Windpark Haida [{'count': 3, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'NTK600', 'source_id': 'mastr-wind-20261103-bb'}]
Ryssbol [{'count': 6, 'manufacturer': 'Vestas', 'model': 'V-110', 'source_id': 'vbk-20261103-2135-layer-5'}]
Vindpark Ränsliden [{'count': 7, 'manufacturer': 'Siemens', 'model': 'SWT-3.6-130', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Itterbeck [{'count': 8, 'manufacturer': 'Nordex SE', 'model': 'N163/6.X TCS164', 'source_id': 'mastr-wind-20261103-ni'}]
Ågård [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-2135-layer-5'}]
Brostorp-Snogeröd [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E82/2000', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Venne [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E175 EP5 E2', 'source_id': 'mastr-wind-20261103-ni'}]
Vallerstad Vind [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1535-layer-5'}]
Windpark Wietmarschen [{'count': 5, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'EW 1.5sl', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Zedtwitz [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'Enercon E-101', 'source_id': 'mastr-wind-20261103-by'}]
Granberg [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V90-2,0', 'source_id': 'vbk-20261104-0135-layer-5'}]
Mutkalampi [{'count': None, 'manufacturer': 'Vestas', 'model': 'V150-4.2 MW', 'source_id': 'vestas-enventus-case'}, {'count': None, 'manufacturer': 'Vestas', 'model': 'V162-6.0 MW', 'source_id': 'vestas-enventus-case'}]
Windpark Puschwitz [{'count': 10, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 80-2.0', 'source_id': 'mastr-wind-20261103-sn'}]
Bolstads-Prästgård 1 [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Boxberg [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V-162-6.0 MW', 'source_id': 'mastr-wind-20261103-sn'}]
Windpark Herrenkoog GmbH & Co. KG [{'count': 8, 'manufacturer': 'ENERCON GmbH', 'model': 'E82', 'source_id': 'mastr-wind-20261103-sh'}]
Rodovålen [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E82 - 2MW', 'source_id': 'vbk-20261104-0435-layer-5'}, {'count': 1, 'manufacturer': 'Vestas', 'model': 'V52-850', 'source_id': 'vbk-20261104-0435-layer-5'}, {'count': 1, 'manufacturer': 'Bonus', 'model': '600', 'source_id': 'vbk-20261104-0435-layer-5'}, {'count': 1, 'manufacturer': 'NEG Micon', 'model': '750', 'source_id': 'vbk-20261104-0435-layer-5'}]
Windpark Lübbenau [{'count': 8, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 90', 'source_id': 'mastr-wind-20261103-bb'}]
Fäbodliden II [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V112', 'source_id': 'vbk-20261104-0535-layer-5'}]
Windpark Vierraden [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-66', 'source_id': 'mastr-wind-20261103-bb'}]
Erikstads-Björnebol [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2235-layer-5'}]
Norra Hunna [{'count': 4, 'manufacturer': 'Siemens Gamesa', 'model': 'SWT-DD-142', 'source_id': 'vbk-20261104-0035-layer-5'}]
Windpark Tegelberg-Donzdorf [{'count': 3, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 2.75-120', 'source_id': 'mastr-wind-20261103-bw'}]
Orenda Windpark GmbH & Co. KG [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E70', 'source_id': 'mastr-wind-20261103-sh'}]
He [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2035-layer-5'}]
Mönsterås Bruk [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-1735-layer-5'}]
Utö [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE27', 'source_id': 'vbk-20261103-layer-9'}]
Windpark Schafstedt [{'count': 6, 'manufacturer': 'Nordex SE', 'model': 'N163-5.7MW STE', 'source_id': 'mastr-wind-20261103-sh'}]
Källeberg [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2235-layer-5'}]
Fågelbacka [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2235-layer-5'}]
Björkö [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E52', 'source_id': 'vbk-20261103-layer-5'}]
Gislöv [{'count': 2, 'manufacturer': 'NEG Micon', 'model': 'NM48', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Frielendorf-Dorheim [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V150 – 6.0', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Pamsendorf [{'count': 5, 'manufacturer': 'Nordex SE', 'model': 'N117', 'source_id': 'mastr-wind-20261103-by'}]
Windpark Kittlitz GmbH Co. KG [{'count': 5, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V90', 'source_id': 'mastr-wind-20261103-bb'}]
Windpark Ravenstein [{'count': 4, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 2.5-120', 'source_id': 'mastr-wind-20261103-bw'}]
Silkomhöjden [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E-82', 'source_id': 'vbk-20261104-0135-layer-5'}, {'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261104-0135-layer-5'}]
Windpark Bahren West [{'count': 9, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas Typ V150-5,6 MW', 'source_id': 'mastr-wind-20261103-bb'}]
Windpark Nartum [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N149/5.X', 'source_id': 'mastr-wind-20261103-ni'}]
Greby [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM52', 'source_id': 'vbk-20261103-1735-layer-5'}]
Atteby [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Paljakoberget [{'count': 1, 'manufacturer': 'WinWind', 'model': 'WWD-1', 'source_id': 'vbk-20261104-0135-layer-5'}]
Ramdala [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-1935-layer-5'}]
MellsaVind 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261104-0035-layer-5'}]
Ekekullen Dintestorp [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1535-layer-5'}, {'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1535-layer-5'}]
Långåvålen [{'count': 7, 'manufacturer': 'Enercon', 'model': 'E70/E4-2000', 'source_id': 'vbk-20261104-0435-layer-5'}]
TL Vind 3 [{'count': 1, 'manufacturer': 'Kenersys', 'model': 'K100', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Großenaspe [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V136', 'source_id': 'mastr-wind-20261103-sh'}]
Glötesvålen [{'count': 30, 'manufacturer': 'Vestas', 'model': 'V90-3,0', 'source_id': 'vbk-20261104-0435-layer-5'}]
Vättlösa I [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Biängen [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Slättäng I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Ängalid II, Karlsnäs [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM52/900', 'source_id': 'vbk-20261103-2035-layer-5'}]
Annelöv 1 [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W3700/500', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Zollchow [{'count': 6, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Delta4000 - N175/6.X', 'source_id': 'mastr-wind-20261103-bb'}, {'count': 2, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Delta4000 - N149/5.X', 'source_id': 'mastr-wind-20261103-bb'}]
Windpark Bestwig-Berlar [{'count': 5, 'manufacturer': 'VENSYS Energy AG', 'model': 'VENSYS 77', 'source_id': 'mastr-wind-20261103-nw'}]
Kräklingbo Vidfälle [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-1835-layer-5'}, {'count': 1, 'manufacturer': 'Enercon', 'model': 'E-92', 'source_id': 'vbk-20261103-1835-layer-5'}]
Tängelsbol [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-1', 'source_id': 'vbk-20261103-2235-layer-5'}, {'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Mäsinge [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V42', 'source_id': 'vbk-20261103-2035-layer-5'}]
Långeryd I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Håkantorp 2 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Kampagården 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Mässingberget [{'count': 11, 'manufacturer': 'Vestas', 'model': 'V100-2.0', 'source_id': 'vbk-20261104-0135-layer-5'}]
St Herrestad II [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E40/500', 'source_id': 'vbk-20261103-2035-layer-5'}]
Lagmansberga 21 [{'count': 3, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Stentjärnåsen [{'count': 5, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261104-0435-layer-5'}]
Fröreda [{'count': 7, 'manufacturer': 'Vestas', 'model': 'V126-3.3', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark am Sund [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-138 EP3 E3', 'source_id': 'mastr-wind-20261103-mv'}]
Windpark Matzenhöhe [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175-6.8 MW', 'source_id': 'mastr-wind-20261103-he'}]
Jättadansen I [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Niep [{'count': 2, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N149 5.X', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163 6.X', 'source_id': 'mastr-wind-20261103-nw'}]
Vitberget V1 [{'count': 15, 'manufacturer': 'Nordex', 'model': 'N163/6.X', 'source_id': 'vbk-20261104-0335-layer-5'}]
Tomasliden [{'count': 10, 'manufacturer': 'Nordex', 'model': 'N163', 'source_id': 'vbk-20261104-0535-layer-5'}]
Windpark Dülmen Daldrup [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E1', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5', 'source_id': 'mastr-wind-20261103-nw'}]
Hov [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-2135-layer-5'}]
Vitberget V3 [{'count': 6, 'manufacturer': 'Nordex', 'model': 'N149/5.X', 'source_id': 'vbk-20261104-0335-layer-5'}]
Windpark Magolsheim [{'count': 6, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Burlage [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-82 E2 TES', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Teschendorf [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-138 EP3 E2', 'source_id': 'mastr-wind-20261103-ni'}]
Hedeskoga Vindkraftpark [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V47', 'source_id': 'vbk-20261103-2035-layer-5'}, {'count': 2, 'manufacturer': 'Enercon', 'model': 'E70', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark westliche Wälder [{'count': 10, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-by'}]
Lilla Marieholms Kraft AB [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2035-layer-5'}]
Barsebäck [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V39', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Dürrwangen [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-82 E2 2.3 MW', 'source_id': 'mastr-wind-20261103-by'}]
Kärrets Gård [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE47', 'source_id': 'vbk-20261103-2135-layer-5'}]
Knuts kulle [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1535-layer-5'}]
Windpark Thurnau [{'count': 10, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N117/2400', 'source_id': 'mastr-wind-20261103-by'}]
Windpark Lußhardt [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E175 EP5 E2', 'source_id': 'mastr-wind-20261103-bw'}]
Björkliden [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W4200', 'source_id': 'vbk-20261103-2035-layer-5'}]
Furuby [{'count': 10, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 5.8-170', 'source_id': 'vbk-20261103-1635-layer-5'}]
Storrun [{'count': 12, 'manufacturer': 'Nordex', 'model': 'N90-2,5', 'source_id': 'vbk-20261104-0435-layer-5'}]
Höreryd [{'count': 1, 'manufacturer': 'GE Wind Energy', 'model': 'GE 1.6 - 100 96HH', 'source_id': 'vbk-20261103-1535-layer-5'}]
Windpark Weisendorf [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V172-7.2', 'source_id': 'mastr-wind-20261103-by'}]
Brönneslöv [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E44/600', 'source_id': 'vbk-20261103-2035-layer-5'}]
Grimsås [{'count': 13, 'manufacturer': 'Siemens', 'model': 'SWT 3.6-130', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Pfeffelbach [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N175-6.8 MW', 'source_id': 'mastr-wind-20261103-rp'}]
Vindpark Lursäng [{'count': 3, 'manufacturer': 'Siemens Gamesa', 'model': 'SG-155', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Eurowind Laar [{'count': 4, 'manufacturer': 'Senvion Deutschland GmbH', 'model': 'Repower MM 92 Evolution', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Kramerhof [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-40', 'source_id': 'mastr-wind-20261103-mv'}]
Torseröds Vindkraftpark 5 [{'count': 5, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Gudingen (Sturkö 2) [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261103-1935-layer-5'}]
Lagmansberga [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V44', 'source_id': 'vbk-20261103-1135-layer-5'}]
Dalby [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E-103', 'source_id': 'vbk-20261103-2035-layer-5'}]
Kuślin [{'configuration_scope': 'Project model label; not equated to a different rating/revision in equipment catalogue', 'count': 12, 'locator': 'Main project detail: headline quantities, launch/implementation observation and project description', 'manufacturer': 'Vestas', 'model': 'V126-3.3 MW', 'source_id': 'pne_kuslin_detail'}]
Eolus Vind [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Klämman [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V126-3.3', 'source_id': 'vbk-20261103-1535-layer-5'}]
Windpark Luko GmbH & Co. KG [{'count': 12, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 2.5 120', 'source_id': 'mastr-wind-20261103-st'}]
Vindkraft Stjärnarp [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V100-1.8', 'source_id': 'vbk-20261103-2135-layer-5'}]
Bürgerwindpark Altenrheine [{'count': 5, 'manufacturer': 'GE Wind Energy GmbH', 'model': '3.2-130-134', 'source_id': 'mastr-wind-20261103-nw'}]
Almbacka, Felestad [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM48/750', 'source_id': 'vbk-20261103-2035-layer-5'}]
Björnvinden [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'MI748', 'source_id': 'vbk-20261103-2235-layer-5'}]
Tollarpabjär [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E92-2.35', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Pferdsfeld GmbH & Co. KG [{'count': 6, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V126', 'source_id': 'mastr-wind-20261103-rp'}]
Juktan Vindkraftpark [{'count': 9, 'manufacturer': 'Siemens', 'model': 'SWT-2.3-113', 'source_id': 'vbk-20261104-0535-layer-5'}]
Windpark Freudenberg/M. (MVV) [{'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N 177/2400', 'source_id': 'mastr-wind-20261103-bw'}, {'count': 6, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N117/2400', 'source_id': 'mastr-wind-20261103-bw'}]
Halvås [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Seskarö [{'count': 5, 'manufacturer': 'WinWind', 'model': 'WWD1-64', 'source_id': 'vbk-20261104-0635-layer-5'}]
Börstad 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Ax-El [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW290', 'source_id': 'vbk-20261103-2135-layer-5'}]
Lyrestad II [{'count': 8, 'manufacturer': 'Vestas', 'model': 'V126', 'source_id': 'vbk-20261103-2235-layer-5'}]
MÄRENE 1992 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Bredenbek [{'count': 8, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N149/5.X', 'source_id': 'mastr-wind-20261103-sh'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N149/5.7 STE', 'source_id': 'mastr-wind-20261103-sh'}]
Bromöllan [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE42', 'source_id': 'vbk-20261103-2235-layer-5'}]
Vistena 15-1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Rögle [{'count': 8, 'manufacturer': 'GE Wind Energy', 'model': 'GE Energy 2.85-103', 'source_id': 'vbk-20261103-2035-layer-5'}]
vkv_lin-003 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V44', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Freiensteinau-Radmühl [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 162-6.0', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Elsdorf-Tollhausen [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N149/5.X TCS 164', 'source_id': 'mastr-wind-20261103-nw'}]
Näsby/Överberg [{'count': 7, 'manufacturer': 'GE Wind Energy', 'model': 'GE 2.5-103', 'source_id': 'vbk-20261103-1135-layer-5'}]
Vindpark Svartvallsberget [{'count': 10, 'manufacturer': 'Gamesa', 'model': 'G114', 'source_id': 'vbk-20261104-0235-layer-5'}]
Windpark Lahn-Wieste [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-160 EP5 E3 R1', 'source_id': 'mastr-wind-20261103-ni'}]
Vindpark Kingebol [{'count': 6, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 6.2-170', 'source_id': 'vbk-20261103-2235-layer-5'}]
Lucia, Boholmen [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW375', 'source_id': 'vbk-20261103-2335-layer-5'}]
Runnestad I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Rödstahöjden [{'count': 6, 'manufacturer': 'Vestas', 'model': 'V112', 'source_id': 'vbk-20261104-0335-layer-5'}]
Viscaria 1 [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM52', 'source_id': 'vbk-20261104-0635-layer-5'}]
Windpark Leutersdorf [{'count': 4, 'manufacturer': 'Tacke GmbH & Co. KG', 'model': 'TW600', 'source_id': 'mastr-wind-20261103-sn'}, {'count': 1, 'manufacturer': 'Tacke GmbH & Co. KG', 'model': 'TW600e', 'source_id': 'mastr-wind-20261103-sn'}, {'count': 1, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'M 1800-600', 'source_id': 'mastr-wind-20261103-sn'}]
Windpark Drehnow [{'count': 7, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'NM 82/1500', 'source_id': 'mastr-wind-20261103-bb'}]
Nötåsen [{'count': 4, 'manufacturer': 'Gamesa', 'model': 'Gamesa G114', 'source_id': 'vbk-20261104-0335-layer-5'}]
Högersröd [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2035-layer-5'}]
Stengårdsholma [{'count': 10, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark Dachsenhausen [{'count': 1, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V150-6.0', 'source_id': 'mastr-wind-20261103-rp'}, {'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V172-7.2', 'source_id': 'mastr-wind-20261103-rp'}]
Bure 3 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E44/600', 'source_id': 'vbk-20261104-0535-layer-9'}]
Windpark Hilsberg [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-101', 'source_id': 'mastr-wind-20261103-he'}]
Bürgerwindpark Kirchgellersen [{'count': 7, 'manufacturer': 'Nordex SE', 'model': 'N175-6.8MW', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Heidsiek [{'count': 5, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 162-6.2', 'source_id': 'mastr-wind-20261103-ni'}]
Råborg [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W2700', 'source_id': 'vbk-20261103-2035-layer-5'}]
Simona Vindkraft Leringen [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Glänås Vind [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Lindesnes — 2019 repowering [{'configuration': 'registry label; exact OEM revision unresolved', 'count': 2, 'locator': 'plant66/TurbinID99', 'manufacturer': 'Vestas', 'model': 'V112-3.6', 'source_id': 'nve-wind-api-20261108'}]
Windpark Bönebüttel [{'count': 7, 'manufacturer': 'ENERCON GmbH', 'model': 'E 160', 'source_id': 'mastr-wind-20261103-sh'}]
Andersfält Mitt [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Hohenahr [{'count': 7, 'manufacturer': 'Nordex SE', 'model': 'N117', 'source_id': 'mastr-wind-20261103-he'}]
VIGLUNDA / 4456 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Lieger Wald [{'count': 5, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V126', 'source_id': 'mastr-wind-20261103-rp'}]
Boberg 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Skatofta [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2235-layer-5'}]
Em [{'count': 8, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-1735-layer-5'}]
Skogaby [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V100-1.8', 'source_id': 'vbk-20261103-2135-layer-5'}]
Bondorlunda [{'count': 2, 'manufacturer': 'Gamesa', 'model': 'G58', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Jerxheim [{'count': 2, 'manufacturer': 'Nordex SE', 'model': 'N163/6X', 'source_id': 'mastr-wind-20261103-ni'}, {'count': 1, 'manufacturer': 'Nordex SE', 'model': 'N 163/6X', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Schmohlhöhe [{'count': 6, 'manufacturer': 'ENERCON GmbH', 'model': 'ENERCON E-82', 'source_id': 'mastr-wind-20261103-sn'}]
Skarhult [{'count': 4, 'manufacturer': 'Enercon', 'model': 'E44/600', 'source_id': 'vbk-20261103-2035-layer-5'}, {'count': 4, 'manufacturer': 'Enercon', 'model': 'E82/2000', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Erndtebrück [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N133/4.8MW', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N149/5.X', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163/6.X', 'source_id': 'mastr-wind-20261103-nw'}]
Finnhyttan [{'count': 7, 'manufacturer': 'Vestas', 'model': 'V100/1,8 MW', 'source_id': 'vbk-20261104-0135-layer-5'}]
Greater Changhua 2a [{'count': 36, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 8.0-167 DD', 'source_id': 'changhua-open', 'unit_rating_kw': 8000}]
Storugns vindpark [{'count': 6, 'manufacturer': 'Vestas', 'model': 'V47-660kw', 'source_id': 'vbk-20261103-1835-layer-5'}, {'count': 3, 'manufacturer': 'Vestas', 'model': 'V66-1.75', 'source_id': 'vbk-20261103-1835-layer-5'}, {'count': 2, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1835-layer-5'}]
Windpark Ondrup GmbH & Co. KG [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163/6.8', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Weißkollm [{'count': 5, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'EnVentus V172-7.2', 'source_id': 'mastr-wind-20261103-sn'}]
Bast [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E44/600', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Unglinghausen [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V172 7.2 MW', 'source_id': 'mastr-wind-20261103-nw'}]
Almetorps Säteri [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V27', 'source_id': 'vbk-20261103-2235-layer-5'}]
Middagsberget [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E-101-3,05', 'source_id': 'vbk-20261104-0435-layer-5'}]
Gislöv II [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Masendorf [{'count': 7, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V80-2.0 MW', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Amtenhauser Berg [{'count': 5, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V126', 'source_id': 'mastr-wind-20261103-bw'}]
Hangelösa 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Ävlingeby gård [{'count': 1, 'manufacturer': 'WindEn', 'model': 'WindEn 45', 'source_id': 'vbk-20261103-layer-5'}]
Windpark Lindenberg GmbH & Co. KG [{'count': 5, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N117/2400', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Reinberg [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V39', 'source_id': 'mastr-wind-20261103-mv'}]
STRÖMMESTAD [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V100', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Nieder-Schleidern [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V162 5.6 EnVentus', 'source_id': 'mastr-wind-20261103-he'}]
Lanthamnen Klinte [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W490/37', 'source_id': 'vbk-20261103-1835-layer-5'}]
Dalom [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V44-600', 'source_id': 'vbk-20261104-0335-layer-5'}]
Bränneberg [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Arvidstorp vind [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E53-800', 'source_id': 'vbk-20261103-2235-layer-5'}]
Ventosum 10 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE472', 'source_id': 'vbk-20261103-2135-layer-5'}]
Runnestad2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Larsbo [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-2035-layer-9'}]
Haraholmen [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V47-660', 'source_id': 'vbk-20261104-0635-layer-5'}]
Häjsberget och södra Länsmansberget [{'count': 13, 'manufacturer': 'Siemens Gamesa', 'model': 'DD142', 'source_id': 'vbk-20261103-2335-layer-5'}]
Windpark Hopfenberg [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-160 EP5 E3 R1', 'source_id': 'mastr-wind-20261103-he'}]
Bürgerwindpark Albersdorf [{'count': 6, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V112 - 3,3MW', 'source_id': 'mastr-wind-20261103-sh'}]
Hackegården [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-1135-layer-5'}]
Odarslöv [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E70/2000', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Rorup [{'count': 1, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N149', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 2, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N 175', 'source_id': 'mastr-wind-20261103-nw'}]
Håkantorp 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark GmbH & Co. Conneforde KG [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-40/6.44', 'source_id': 'mastr-wind-20261103-ni'}]
Stora lund I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Fågelås-Torp [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Bahren West II [{'count': 11, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas Typ V150-5,6 MW', 'source_id': 'mastr-wind-20261103-bb'}]
Galtås Syd [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V27', 'source_id': 'vbk-20261103-2135-layer-5'}]
Sävedalen [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Hermannstein [{'count': 6, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 162-6.2 MW', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Bad Harzburg [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-40/05.40', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Vielitz [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N-117', 'source_id': 'mastr-wind-20261103-by'}]
Hakarp [{'count': 8, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1935-layer-5'}]
Freja Olsäng [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC406', 'source_id': 'vbk-20261103-1935-layer-5'}]
Gårdsten [{'count': 1, 'manufacturer': 'Kenersys', 'model': 'K82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Latikberg [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E-48', 'source_id': 'vbk-20261104-0535-layer-5'}]
Rävsjö [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Storugns 10 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1835-layer-5'}]
Kvismaren 3 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261104-0035-layer-5'}]
Ebert Windpark Börry [{'count': 3, 'manufacturer': 'Nordex SE', 'model': 'N163/6.X', 'source_id': 'mastr-wind-20261103-ni'}]
Odensbacken 1 [{'count': 1, 'manufacturer': 'Gamesa', 'model': 'G58', 'source_id': 'vbk-20261104-0035-layer-5'}]
Kvilla 1 [{'count': 4, 'manufacturer': 'Sinovel', 'model': 'SL3000', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark Nidda Harbwald [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V172', 'source_id': 'mastr-wind-20261103-he'}]
Vindpark Kölvallen [{'count': 40, 'manufacturer': 'Siemens', 'model': 'SG-6,6-170', 'source_id': 'vbk-20261104-0235-layer-5'}, {'count': 1, 'manufacturer': 'Siemens', 'model': 'SG-6,6-155', 'source_id': 'vbk-20261104-0235-layer-5'}]
Stavlösa [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Vind Invest [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'MI748', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Regesbostel [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V150', 'source_id': 'mastr-wind-20261103-ni'}]
Slottsbol [{'count': 6, 'manufacturer': 'Gamesa', 'model': 'G97', 'source_id': 'vbk-20261104-0035-layer-5'}]
Vindkraftpark Riberget [{'count': 11, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 170', 'source_id': 'vbk-20261104-0235-layer-5'}, {'count': 1, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 170', 'source_id': 'vbk-20261104-0235-layer-12'}]
Hovgården I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Kvarnbråten [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E 48', 'source_id': 'vbk-20261103-2335-layer-5'}]
Vindpark Högkölen [{'count': 18, 'manufacturer': 'Vestas', 'model': 'V126', 'source_id': 'vbk-20261104-0235-layer-5'}]
Havsvind [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE47', 'source_id': 'vbk-20261103-2135-layer-5'}]
Prästbolet [{'count': 2, 'manufacturer': 'Enercon', 'model': 'EC82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Hovenäset, Ingeborg [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE39', 'source_id': 'vbk-20261103-2235-layer-5'}]
Milletorp [{'count': 11, 'manufacturer': 'Siemens', 'model': 'SWT-2,3-101', 'source_id': 'vbk-20261103-1535-layer-5'}]
Herrgårdsvind [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Lundby Trädet [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E-138 EP3', 'source_id': 'vbk-20261103-2235-layer-5'}]
Borrud 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2000', 'source_id': 'vbk-20261103-2235-layer-12'}]
Sandbacken [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM 52', 'source_id': 'vbk-20261103-2335-layer-5'}]
Wahlby 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Stjernarps Gods [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W4200', 'source_id': 'vbk-20261103-2135-layer-5'}]
ENERCON Windpark GmbH & Co. Padenstedt KG [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-70 E4', 'source_id': 'mastr-wind-20261103-sh'}]
Flottskär [{'count': 1, 'manufacturer': 'Nordex', 'model': 'N117', 'source_id': 'vbk-20261103-layer-7'}]
Windpark Niederkirchen [{'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E 66/20.70', 'source_id': 'mastr-wind-20261103-rp'}, {'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-66/20.70', 'source_id': 'mastr-wind-20261103-rp'}, {'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-70-E4', 'source_id': 'mastr-wind-20261103-rp'}, {'count': 2, 'manufacturer': 'ENERCON GmbH', 'model': 'E70-E4', 'source_id': 'mastr-wind-20261103-rp'}]
Vindpark Mombyåsen [{'count': 10, 'manufacturer': 'Vestas', 'model': 'V126', 'source_id': 'vbk-20261104-0235-layer-5'}]
Skorteby, Storebror [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-1135-layer-5'}]
Värslen [{'count': 2, 'manufacturer': 'Fuhrländer', 'model': 'FL 2500-100-2 500', 'source_id': 'vbk-20261103-2235-layer-5'}]
Säby [{'count': 4, 'manufacturer': 'Enercon', 'model': 'E48/800', 'source_id': 'vbk-20261103-1935-layer-5'}]
Lörby 4 Lörby/Ysane [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1935-layer-5'}]
Erikstads-Mossebol 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Vackerdalberget [{'count': 3, 'manufacturer': 'Gamesa', 'model': 'G90', 'source_id': 'vbk-20261104-0235-layer-5'}]
Fryksdalshöjden [{'count': 7, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 6.2-170', 'source_id': 'vbk-20261103-2335-layer-5'}]
ISTRUMS-LYCKE / 5695 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Langen [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-160 EP5 E3 R1', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Gomadingen [{'count': 5, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V162 - 6.2 MW', 'source_id': 'mastr-wind-20261103-bw'}]
Stor-Skälsjön [{'count': 42, 'manufacturer': 'Siemens Gamesa', 'model': 'SG6.2-170', 'source_id': 'vbk-20261104-0335-layer-5'}]
Planet energy Windpark Soltau GmbH & Co. KG [{'count': 3, 'manufacturer': 'Bonus Energy A/S', 'model': 'AN Bonus 1,3 MW/62', 'source_id': 'mastr-wind-20261103-ni'}]
Blåliden [{'count': 4, 'manufacturer': 'GE Wind Energy', 'model': 'GE 5.8-158', 'source_id': 'vbk-20261104-0635-layer-5'}, {'count': 2, 'manufacturer': 'GE Wind Energy', 'model': 'GE 3.6-137', 'source_id': 'vbk-20261104-0635-layer-5'}]
Windpark Pützhöhe [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N80', 'source_id': 'mastr-wind-20261103-rp'}]
Legeved [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V100', 'source_id': 'vbk-20261103-2035-layer-5'}]
Kronoberget [{'count': 16, 'manufacturer': 'Vestas', 'model': 'V136', 'source_id': 'vbk-20261104-0035-layer-5'}]
Heden [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Önusberget [{'count': 137, 'manufacturer': 'GE Wind Energy', 'model': 'Cypress 5.5-158', 'source_id': 'vbk-20261104-0635-layer-5'}]
Windpark Mühlhausen [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V-112 3.0', 'source_id': 'mastr-wind-20261103-by'}]
FW Karcino [{'configuration_scope': 'V90 label; no exact rating catalogue record inferred', 'count': 17, 'locator': 'Main project description', 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'pne_karcino_detail'}]
Windpark Illmersdorf III [{'count': 10, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163-5.7 MW', 'source_id': 'mastr-wind-20261103-bb'}]
ENTORP / 5690-1 [{'count': 2, 'manufacturer': 'Enercon', 'model': 'EC82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Vistena 18-1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Utzedel [{'count': 6, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163-6.X MW', 'source_id': 'mastr-wind-20261103-mv'}]
Skutskär [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-layer-5'}]
CEE Windpark Aßlar GmbH & Co. KG [{'count': 6, 'manufacturer': 'GE Renewable Germany GmbH', 'model': 'GE 2.75-120', 'source_id': 'mastr-wind-20261103-he'}]
Bliekevare [{'count': 18, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261104-0535-layer-5'}]
Källstorp I [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Tormoseröd Vindpark [{'count': 11, 'manufacturer': 'Siemens Gamesa', 'model': 'SG-6.6-155', 'source_id': 'vbk-20261103-2235-layer-5'}]
Paucali [{'count': 9, 'equipment_record_id': None, 'locator': 'Descripción de las Instalaciones; GREEN CAPITAL DEVELOPMENT XXXVII S.L.U.; PE Paucali and budget paragraphs', 'manufacturer': 'Nordex', 'model': 'N175', 'rated_power_mw': 7.0, 'scope': 'Complete proposed fleet; not installed inventory', 'source_id': 'BOE-B-2026-23315'}]
Susekulla [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC406', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark Merzenich [{'count': 3, 'manufacturer': 'Fuhrländer AG', 'model': 'MD 70', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Lippersdorf [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163/6.X', 'source_id': 'mastr-wind-20261103-sn'}]
Rammeldalsberget [{'count': 6, 'manufacturer': 'Gamesa', 'model': 'G114-2.5', 'source_id': 'vbk-20261104-0335-layer-5'}]
CEE Windpark Hainstadt-Buchen [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V126-3.3/3.45 MW BWC', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Marke [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N149-5.X 5,6 MW', 'source_id': 'mastr-wind-20261103-he'}]
Mullbergs Vindpark [{'count': 26, 'manufacturer': 'Siemens', 'model': 'SWT-3.0-113 DD', 'source_id': 'vbk-20261104-0435-layer-5'}]
Karleby vindkraftverk [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Byråsen [{'count': 2, 'manufacturer': 'Vestas', 'model': 'Vestas V80 2,0 MW', 'source_id': 'vbk-20261104-0135-layer-5'}]
Windpark Kürrenberg [{'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E 101', 'source_id': 'mastr-wind-20261103-rp'}, {'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-101', 'source_id': 'mastr-wind-20261103-rp'}, {'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'e-101', 'source_id': 'mastr-wind-20261103-rp'}]
Sydvind [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-2135-layer-5'}]
Trianel Windpark Creußen [{'count': 5, 'manufacturer': 'Nordex SE', 'model': 'N117/2400', 'source_id': 'mastr-wind-20261103-by'}]
Eke Vind [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Råmmarehemmet [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E-138 EP3', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Nieder-/ Mittelfeld (Münster) [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-160 EP5 E3 R1', 'source_id': 'mastr-wind-20261103-he'}]
Lilla Isie [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W4200', 'source_id': 'vbk-20261103-2035-layer-5'}]
Mörkagården 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
ewz Windpark Kleinbrembach GmbH [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V90-VCS-2.0MW-690V', 'source_id': 'mastr-wind-20261103-th'}, {'count': 1, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V90', 'source_id': 'mastr-wind-20261103-th'}]
Vindmannen [{'count': 1, 'manufacturer': 'Bonus', 'model': '600/44', 'source_id': 'vbk-20261104-0635-layer-5'}]
Hällingarna Vind ek för [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261104-0435-layer-5'}]
Windpark Brand [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163/6.8', 'source_id': 'mastr-wind-20261103-bw'}]
Backa Vind 3 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Verenafohren [{'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N 131/3300 PH 134', 'source_id': 'mastr-wind-20261103-bw'}, {'count': 2, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N 131/3300 PH 134', 'source_id': 'mastr-wind-20261103-bw'}]
Krassaberg [{'count': 1, 'manufacturer': 'GE Wind Energy', 'model': 'GE 1.6 - 100 96HH', 'source_id': 'vbk-20261103-1535-layer-5'}]
Lönneborg [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1935-layer-5'}]
Östra Karaby II [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2035-layer-5'}]
Lehtirova vindkraftpark [{'count': 41, 'manufacturer': 'Vestas', 'model': 'V126-3.6', 'source_id': 'vbk-20261104-0635-layer-5'}]
Windpark Dettelbach-Bibergau [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V172-7.2', 'source_id': 'mastr-wind-20261103-by'}]
vkv_lin-015 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1135-layer-5'}]
Bürgerwindpark Sprüng Repowering GmbH & Co. KG [{'count': 7, 'manufacturer': 'ENERCON GmbH', 'model': 'E138 EP3 E2', 'source_id': 'mastr-wind-20261103-sh'}]
Eveboda [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V47-660', 'source_id': 'vbk-20261103-1135-layer-5'}]
Kvismaren 2 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261104-0035-layer-5'}]
Isberget III [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Göksholm [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC82', 'source_id': 'vbk-20261104-0035-layer-5'}]
Windpark Hagenauer Forst [{'count': 6, 'manufacturer': 'ENERCON GmbH', 'model': 'E175 EP5 E2 HST', 'source_id': 'mastr-wind-20261103-by'}]
Hangvar Kyrkebys 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-1835-layer-5'}]
Brumstorp 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Närefors 1 Norr [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82/2000', 'source_id': 'vbk-20261103-2235-layer-5'}]
Bondegärde [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
3954 Gallegården [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Wenersnes [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Sörlidberget [{'count': 20, 'manufacturer': 'Nordex', 'model': 'N163/6.X', 'source_id': 'vbk-20261104-0335-layer-5'}]
Gärds-Köpinge [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V52-850', 'source_id': 'vbk-20261103-2035-layer-5'}]
Lammevad [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2235-layer-5'}]
GPE Windpark Drackenstein GmbH & Co. KG [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N131/3300', 'source_id': 'mastr-wind-20261103-bw'}]
Céfiro [{'count': 17, 'equipment_record_id': None, 'locator': 'Descripción de las Instalaciones; GREEN CAPITAL DEVELOPMENT XLI S.L.U.; PE Céfiro and budget paragraphs', 'manufacturer': 'Nordex', 'model': 'N175', 'rated_power_mw': 6.525, 'scope': 'Complete proposed fleet; not installed inventory', 'source_id': 'BOE-B-2026-23315'}]
Häckenäs Betty [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE39', 'source_id': 'vbk-20261103-1135-layer-5'}]
Henån [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE20c', 'source_id': 'vbk-20261103-2235-layer-9'}]
Windpark Alt Zachun [{'count': 8, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas 112', 'source_id': 'mastr-wind-20261103-mv'}]
Windpark Remlingen [{'count': 6, 'manufacturer': 'Nordex SE', 'model': 'N117', 'source_id': 'mastr-wind-20261103-by'}]
Ljungås [{'count': 1, 'manufacturer': 'WinWind', 'model': 'WWD-1N', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Schneverdingen [{'count': 6, 'manufacturer': 'Gamesa Corporación Tecnológica S.A.', 'model': 'G97', 'source_id': 'mastr-wind-20261103-ni'}]
Sjisjka Vindkraftspark [{'count': 30, 'manufacturer': 'Vestas', 'model': 'V100-2,6', 'source_id': 'vbk-20261104-0635-layer-5'}]
MSH Bürger-Windpark-Feldatal [{'count': 1, 'manufacturer': 'Sonstige', 'model': 'Vestas V 150 – 6.0 MW', 'source_id': 'mastr-wind-20261103-he'}, {'count': 2, 'manufacturer': 'Sonstige', 'model': 'V 150 – 6.0 MW', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Frettertal [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163/6.X', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163/6.X', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Gadegast GmbH & Co. KG [{'count': 5, 'manufacturer': 'General Electric Deutschland Holding GmbH', 'model': 'GE 2.75-120', 'source_id': 'mastr-wind-20261103-st'}, {'count': 3, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 2.75-120', 'source_id': 'mastr-wind-20261103-st'}]
Bjälbo-Skenaån Vind [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Brunnenkopf [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E 175 EP5 (E2) HST- 175', 'source_id': 'mastr-wind-20261103-by'}]
Sture Nolby HA 046 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC406', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Ohe [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V150-6.0MW EnVentus', 'source_id': 'mastr-wind-20261103-sh'}]
Isberget II [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Harstorp 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1935-layer-5'}]
Windpark Purzien GmbH & Co. KG [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E 48', 'source_id': 'mastr-wind-20261103-st'}]
Windpark Böllenberg GmbH & Co. KG [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175', 'source_id': 'mastr-wind-20261103-ni'}]
669828001 Vallrun [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261104-0435-layer-5'}]
Sölve [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-1935-layer-5'}]
Hästhalla Basebo [{'count': 4, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Barwice [{'configuration_scope': 'Project model label; not equated to a different rating/revision in equipment catalogue', 'count': 14, 'locator': 'Main project detail: headline quantities, launch/implementation observation and project description', 'manufacturer': 'Siemens', 'model': 'SWT-3.0-113', 'source_id': 'pne_barwice_detail'}]
Windpark Kampen [{'count': 6, 'manufacturer': 'ENERCON GmbH', 'model': 'E82', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Ruhlkirchen [{'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N117/2400 Rerferenzertrag: 46828674 kWh/5a', 'source_id': 'mastr-wind-20261103-he'}, {'count': 1, 'manufacturer': 'Nordex SE', 'model': 'N-117', 'source_id': 'mastr-wind-20261103-he'}, {'count': 2, 'manufacturer': 'Nordex SE', 'model': 'N 117', 'source_id': 'mastr-wind-20261103-he'}]
Björkekull Samf.:1 [{'count': 1, 'manufacturer': 'GE Wind Energy', 'model': 'GE 1.6 - 100 96HH', 'source_id': 'vbk-20261103-1535-layer-5'}]
Elvira Vind [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE27', 'source_id': 'vbk-20261103-2135-layer-5'}]
Krzęcin II [{'configuration_scope': 'Project model label; not equated to a different rating/revision in equipment catalogue', 'count': 8, 'locator': 'Main project detail: headline quantities, launch/implementation observation and project description', 'manufacturer': 'Nordex', 'model': 'N117-2.4', 'source_id': 'pne_krzecin_detail'}]
Hansamöllan [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V42', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Dachsberg [{'count': 6, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V150', 'source_id': 'mastr-wind-20261103-bb'}]
Riskebo [{'count': 7, 'manufacturer': 'Vestas', 'model': 'V-162', 'source_id': 'vbk-20261104-0135-layer-5'}]
Windpark Sien II GmbH & Co. KG [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-rp'}]
Egby 2 [{'count': 5, 'manufacturer': 'Enercon', 'model': 'E-82', 'source_id': 'vbk-20261103-1735-layer-5'}]
Örbacken [{'count': 4, 'manufacturer': 'GE Wind Energy', 'model': 'GE 2.5-103', 'source_id': 'vbk-20261103-1135-layer-5'}]
Alma 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Fichtenau [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 126-3.3', 'source_id': 'mastr-wind-20261103-bw'}]
3953 Blad [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Ölseruds prästgård [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2335-layer-5'}]
Ådan (Sturkö 1) [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261103-1935-layer-5'}]
Svarteborgs-Skogen [{'count': 6, 'manufacturer': 'Enercon', 'model': 'E82-2.3', 'source_id': 'vbk-20261103-2235-layer-5'}]
Kincardine [{'count': 5, 'equipment_record_id': 'c63154b2-3163-55f8-9c4e-9d32f95fc6c9', 'manufacturer': 'MHI Vestas Offshore Wind', 'model': 'V164-9.5 MW', 'source_id': 'v164-95', 'unit_rating_kw': 9500}]
Windpark Bassen Ost [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V52 VCS', 'source_id': 'mastr-wind-20261103-ni'}]
Greater Changhua 1 [{'count': 75, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 8.0-167 DD', 'source_id': 'changhua-open', 'unit_rating_kw': 8000}]
CEE Windpark Schwalbach [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-115', 'source_id': 'mastr-wind-20261103-sl'}]
Årjäng NV [{'count': 9, 'manufacturer': 'Vestas', 'model': 'V112', 'source_id': 'vbk-20261103-2335-layer-5'}]
Stora Farsnäs [{'count': 2, 'manufacturer': 'Fuhrländer', 'model': 'FL2500/100', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Lübow [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E40', 'source_id': 'mastr-wind-20261103-mv'}]
Andersfält Norr [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2135-layer-5'}]
Vettebergets Vindpark [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V126', 'source_id': 'vbk-20261103-2235-layer-5'}]
Trianel Windpark Gande [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N 149/ 4.500', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Lager Feld [{'count': 9, 'manufacturer': 'ENERCON GmbH', 'model': 'E - 141', 'source_id': 'mastr-wind-20261103-nw'}]
Balkåkra Vind [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Skagsudde Linda [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261104-0335-layer-5'}]
Waad Al-Shamal [{'count': 67, 'equipment_record_id': None, 'locator': 'PDFpage4 design table; page3 introduction for Al Ghat / page4 introduction for Waad', 'manufacturer': 'Windey Energy Technology Group Co., LTD', 'model': 'WD200-7700', 'rated_power_mw': 7.7, 'scope': 'Complete ESIA design fleet; not installed inventory', 'source_id': 'axia-waad-nts-doc02'}]
Ileberg 1, Tärnmåsen [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2235-layer-5'}]
Slitevind Eriksfält [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Golzwarden [{'count': 6, 'manufacturer': 'ENERCON GmbH', 'model': 'E-101', 'source_id': 'mastr-wind-20261103-ni'}]
Beateberg 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Domsühl [{'count': 5, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163-6.8 MW', 'source_id': 'mastr-wind-20261103-mv'}]
SKALLMEJA / 5680 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Kvismaren 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261104-0035-layer-5'}]
Hultema [{'count': 11, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 5.8-155', 'source_id': 'vbk-20261103-1135-layer-5'}]
Karstorp [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Viscaria 3 [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM52', 'source_id': 'vbk-20261104-0635-layer-5'}]
Tavelberget, etapp 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261104-0135-layer-5'}]
Vindkraftverk Östorp [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'MI748', 'source_id': 'vbk-20261103-2135-layer-5'}]
Bydalen [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM48/750', 'source_id': 'vbk-20261104-0435-layer-5'}]
Tagelberg 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Bårstad [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Stora lund II [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Niederlangen [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-82 E3', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Bunder Interessentenpolder [{'count': 8, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-ni'}]
Varsvik [{'count': 17, 'manufacturer': 'Vestas', 'model': 'V112', 'source_id': 'vbk-20261103-layer-5'}]
Götarsvik [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261104-0035-layer-5'}]
Arlo [{'count': 10, 'equipment_record_id': None, 'locator': 'Descripción de las Instalaciones; GREEN CAPITAL DEVELOPMENT XXXVIII S.L.U.; PE Arlo and budget paragraphs', 'manufacturer': 'Nordex', 'model': 'N175', 'rated_power_mw': 6.525, 'scope': 'Complete proposed fleet; not installed inventory', 'source_id': 'BOE-B-2026-23315'}]
Tegneby [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V44', 'source_id': 'vbk-20261103-1135-layer-9'}]
Windpark Moorgut Ostrhauderfehn [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-66/18.70', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Sonnenborstel [{'count': 9, 'manufacturer': 'ENERCON GmbH', 'model': 'Enercon E-160 EP5 E3 R1', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Herkentrup [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Delta 4000 N149', 'source_id': 'mastr-wind-20261103-nw'}]
Skeby I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Rommerskirchen Butzheim [{'count': 7, 'manufacturer': 'Siemens Gamesa Renewable Energy GmbH & Co. KG', 'model': 'SG6.6-170', 'source_id': 'mastr-wind-20261103-nw'}]
Kornheddinge [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Perl-Borg [{'count': 5, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V112/3.0', 'source_id': 'mastr-wind-20261103-sl'}]
Sophie Hogenäset [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE39', 'source_id': 'vbk-20261103-2235-layer-9'}]
Windpark Friesenhagen [{'count': 6, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N149/4.5', 'source_id': 'mastr-wind-20261103-rp'}, {'count': 1, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N149/4.5', 'source_id': 'mastr-wind-20261103-rp'}]
Glimminge [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W490/37', 'source_id': 'vbk-20261103-2035-layer-5'}, {'count': 1, 'manufacturer': 'WindWorld', 'model': 'W250/29', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Borgentreich-Ost II [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175-6.8 MW', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N175-6.8 MW', 'source_id': 'mastr-wind-20261103-nw'}]
Örja [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-2035-layer-5'}]
Trollenäs [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W3700', 'source_id': 'vbk-20261103-2035-layer-5'}]
Mårtensklack [{'count': 4, 'manufacturer': 'Enercon', 'model': 'E82/2300', 'source_id': 'vbk-20261104-0235-layer-5'}]
Stensåsa [{'count': 7, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1535-layer-5'}]
Tavelberget [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261104-0135-layer-5'}]
Windpark Barnstädt [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E 40', 'source_id': 'mastr-wind-20261103-st'}]
Stora Istad [{'count': 7, 'manufacturer': 'Enercon', 'model': 'E82-2.0', 'source_id': 'vbk-20261103-1735-layer-5'}, {'count': 1, 'manufacturer': 'Enercon', 'model': 'E82-2.0', 'source_id': 'vbk-20261103-1735-layer-6'}]
Hibridación FV-PEol Salinas III [{'base_model_record_id': '3b8f4149-6b7a-5cb3-ae27-3f0b39972010', 'configuration_crosswalk': None, 'count': 8, 'inventory_basis': 'complete proposed eight-unit fleet; no as-built verification', 'locator': 'Description of installations', 'manufacturer': 'Vestas', 'model': 'V163-4.5 MW-118HH', 'source_id': 'BOE-B-2026-29804', 'unit_rating_kw': 4500}]
Sättravallen [{'count': 16, 'manufacturer': 'Vestas', 'model': 'V126', 'source_id': 'vbk-20261103-2335-layer-5'}]
Windpark Östliches Herberger Feld GmbH & Co. KG [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-115', 'source_id': 'mastr-wind-20261103-ni'}]
Elmer 1 - vindkraftverk [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V27', 'source_id': 'vbk-20261104-0035-layer-5'}]
Skeby/Tungelunda vindkraft 4 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Littdorf [{'count': 7, 'manufacturer': 'Tacke GmbH & Co. KG', 'model': 'TW 1.5s', 'source_id': 'mastr-wind-20261103-sn'}, {'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E70 E4', 'source_id': 'mastr-wind-20261103-sn'}]
Medhamra 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1135-layer-5'}]
Hitra [{'boundary': 'Cohort only; exact OEM configuration revision and individual IDs unknown', 'commissioning_date': '2004-08-16', 'count': 23, 'manufacturer': 'Siemens', 'model': 'SWT-2.3-82VS', 'source_id': 'nve-wind-api-20261108', 'unit_rating_kw': 2300}, {'boundary': 'Cohort only; exact OEM configuration revision and individual IDs unknown', 'commissioning_date': '2004-11-05', 'count': 1, 'manufacturer': 'Siemens', 'model': 'SWT-2.3-82VS', 'source_id': 'nve-wind-api-20261108', 'unit_rating_kw': 2300}]
Windpark Brachelen [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E40', 'source_id': 'mastr-wind-20261103-nw'}]
SKALLMEJA / 5694 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Digerberget 1. [{'count': 5, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261104-0435-layer-5'}]
Härjevads Vind [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Månslunda I [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-2035-layer-5'}]
Vindkraftanläggning Norrboda [{'count': 2, 'manufacturer': 'Kenersys', 'model': 'K100 2,5MW', 'source_id': 'vbk-20261104-0035-layer-5'}]
Gunillaberg [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V100 2,2 MW', 'source_id': 'vbk-20261103-1535-layer-5'}]
Windpark Jettebruch [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-66/18.70', 'source_id': 'mastr-wind-20261103-ni'}]
Lörby-Ysane [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-1935-layer-5'}]
Windpark Hauenhorst [{'count': 4, 'manufacturer': 'GE Wind Energy GmbH', 'model': '3.2-130-134', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Spechenwald GmbH & Co. KG [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N131/3000 PH134', 'source_id': 'mastr-wind-20261103-sl'}]
Brasmaviken [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-2235-layer-5'}]
Osvald [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Barbusch [{'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E 40/68NH', 'source_id': 'mastr-wind-20261103-ni'}, {'count': 2, 'manufacturer': 'ENERCON GmbH', 'model': 'E 40/64NH', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Beerwalde [{'count': 5, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'M700', 'source_id': 'mastr-wind-20261103-sn'}]
Trianel Windpark Uckley [{'count': 3, 'manufacturer': 'Nordex SE', 'model': 'N131/3300', 'source_id': 'mastr-wind-20261103-bb'}, {'count': 7, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N131/3300', 'source_id': 'mastr-wind-20261103-bb'}]
Ingel 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V29', 'source_id': 'vbk-20261103-2035-layer-5'}]
Österhultsmåla [{'count': 4, 'manufacturer': 'Nordex', 'model': 'N149', 'source_id': 'vbk-20261103-1735-layer-5'}]
Huggelseke-Bessinge [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-2035-layer-5'}]
Aeolus [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W490/37', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Peterswald-Löffelscheid 2 [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-53', 'source_id': 'mastr-wind-20261103-rp'}]
Windpark Kohlenbek [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E101', 'source_id': 'mastr-wind-20261103-sh'}]
Magnus Ladulås [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Wächtersbach GmbH & Co KG [{'count': 3, 'manufacturer': 'GE Renewable Germany GmbH', 'model': 'GE 2.5-120', 'source_id': 'mastr-wind-20261103-he'}]
Årjäng NV etapp 2 [{'count': 8, 'manufacturer': 'Vestas', 'model': 'V150', 'source_id': 'vbk-20261103-2335-layer-5'}]
SKALLMEJA / 3815 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Straubenhardt [{'count': 11, 'manufacturer': 'Siemens Wind Power GmbH & Co. KG', 'model': 'SWT-3.0-113', 'source_id': 'mastr-wind-20261103-bw'}]
Ås [{'count': 6, 'manufacturer': 'Enercon', 'model': 'E82-2.3', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Olsberg GmbH & Co. KG [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-138 EP3 E3', 'source_id': 'mastr-wind-20261103-nw'}]
Fole Stora Sojdeby - Ryftes Kristina [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-1835-layer-5'}]
Bürgerwindpark Virngrund [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E115', 'source_id': 'mastr-wind-20261103-bw'}, {'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Reinhardswald [{'count': 18, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V150-5.6 MW NH169', 'source_id': 'mastr-wind-20261103-nw'}]
Tumleberg Norr [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2235-layer-5'}]
Skabersjö vindkraftpark [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-2035-layer-5'}]
Nolebo I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Borrby1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Möllenberg [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N62', 'source_id': 'mastr-wind-20261103-nw'}]
Kollbogården I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Tunhem 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Vävinge / Lottstad [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1135-layer-5'}]
Lörby 3 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC406', 'source_id': 'vbk-20261103-1935-layer-5'}]
Lörby 5 Lörby/Ysane [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1935-layer-5'}]
Windpark Vierkirchner Holz [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-by'}]
Skomakerfjellet [{'boundary': 'registry cohort; exact OEM revision unresolved', 'commissioning_date': '2015-12-31', 'count': 3, 'manufacturer': 'Vestas', 'model': 'V112-3.3', 'rated_power_kw': 3300, 'source_id': 'nve-wind-api-20261108'}, {'boundary': 'registry cohort; exact OEM revision unresolved', 'commissioning_date': '2016-01-15', 'count': 1, 'manufacturer': 'Vestas', 'model': 'V112-3.3', 'rated_power_kw': 3300, 'source_id': 'nve-wind-api-20261108'}]
Windpark Polch [{'count': 5, 'manufacturer': 'REpower Systems SE', 'model': 'MM-92', 'source_id': 'mastr-wind-20261103-rp'}]
Windpark Jüterbog [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E 40', 'source_id': 'mastr-wind-20261103-bb'}]
Ebborp Vind, Emma [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-1', 'source_id': 'vbk-20261103-1135-layer-5'}]
CEE Windpark Domsdorf [{'count': 8, 'manufacturer': 'ENERCON GmbH', 'model': 'E-82', 'source_id': 'mastr-wind-20261103-bb'}]
Fjällboheden vindpark [{'count': 10, 'manufacturer': 'Vestas', 'model': 'V150', 'source_id': 'vbk-20261104-0535-layer-5'}]
Lörby 2 Krok [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC406', 'source_id': 'vbk-20261103-1935-layer-5'}]
Windpark Mechern [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V162', 'source_id': 'mastr-wind-20261103-sl'}]
Zepyrus af Hov [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE29', 'source_id': 'vbk-20261103-2235-layer-12'}]
Ersträsk [{'count': 26, 'manufacturer': 'Enercon', 'model': 'E-103', 'source_id': 'vbk-20261104-0635-layer-5'}, {'count': 42, 'manufacturer': 'Enercon', 'model': 'E-126 EP3', 'source_id': 'vbk-20261104-0635-layer-5'}]
Windpark Buchholt [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-nw'}]
Gagnef Rosberget [{'count': 6, 'manufacturer': 'Siemens', 'model': '2,3-113', 'source_id': 'vbk-20261104-0135-layer-12'}]
Elvina [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W2800', 'source_id': 'vbk-20261103-1135-layer-9'}]
TL Vind 2 [{'count': 1, 'manufacturer': 'Kenersys', 'model': 'K100', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Klein Escherde [{'count': 1, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V162-7.2 MW', 'source_id': 'mastr-wind-20261103-ni'}, {'count': 6, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V162-7.2MW', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark 3 Anlagen [{'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E58', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 2, 'manufacturer': 'ENERCON GmbH', 'model': 'E66 / 18.70', 'source_id': 'mastr-wind-20261103-nw'}]
Brännlidens vindkraftspark [{'count': 10, 'manufacturer': 'Vestas', 'model': 'V136', 'source_id': 'vbk-20261104-0535-layer-5'}]
Victoria [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V44', 'source_id': 'vbk-20261103-2235-layer-5'}]
Skorteby, Lillebror [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW27', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Ebneth/Reuth [{'count': 5, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N175/6.X', 'source_id': 'mastr-wind-20261103-by'}, {'count': 1, 'manufacturer': 'Nordex SE', 'model': 'Nordex N175/6.X', 'source_id': 'mastr-wind-20261103-by'}]
Öljersjö [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E-92', 'source_id': 'vbk-20261103-1935-layer-5'}]
Vindkraftverk Forslund [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW27', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Priesberg [{'count': 5, 'manufacturer': 'VENSYS Energy AG', 'model': 'Vensys 112', 'source_id': 'mastr-wind-20261103-sl'}]
Windpark Heidmoor [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E1', 'source_id': 'mastr-wind-20261103-sh'}]
vkv_lin-013 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1135-layer-5'}]
Äsköping [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-layer-5'}]
Lerkaka [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1735-layer-5'}]
Mudarra [{'count': 10, 'equipment_record_id': 'd4fa3e8e-e5f1-5099-8ecc-d73be2e4e87a', 'manufacturer': 'Envision Energy', 'model': 'EN-182', 'scope': 'Proposed October 2026 configuration, not installed inventory', 'source_id': 'BOE-B-2026-32682', 'unit_rating_mw': 7}, {'count': 5, 'equipment_record_id': 'd233ae78-d5ae-53d3-98f3-8c0cf8119866', 'manufacturer': 'Envision Energy', 'model': 'EN-182', 'scope': 'Proposed October 2026 configuration, not installed inventory', 'source_id': 'BOE-B-2026-32682', 'unit_rating_mw': 6}]
Tjustorp [{'count': 1, 'manufacturer': 'WinWind', 'model': 'WWD-1', 'source_id': 'vbk-20261103-2035-layer-9'}]
Fröskog Vindpark [{'count': 6, 'manufacturer': 'Vestas', 'model': 'V162-6.0/6.2', 'source_id': 'vbk-20261103-2235-layer-5'}]
Galtås Nord [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V27', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Schleife BA2 [{'count': 9, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V172 - 7.2', 'source_id': 'mastr-wind-20261103-sn'}]
Windpark Baaler Bruch [{'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E-82 E2', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E92', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Bürgerwald [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N117', 'source_id': 'mastr-wind-20261103-by'}]
Kuddby-Åby [{'count': 1, 'manufacturer': 'WindEn', 'model': '45', 'source_id': 'vbk-20261103-1135-layer-5'}]
Seglaberga 5 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE44', 'source_id': 'vbk-20261103-2135-layer-5'}]
Orrberget/Stensvedberget [{'count': 9, 'manufacturer': 'Nordex', 'model': 'N117', 'source_id': 'vbk-20261104-0135-layer-5'}]
Oberga [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1535-layer-5'}]
Windpark Wedemark Elze [{'count': 15, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E1', 'source_id': 'mastr-wind-20261103-ni'}]
Skärbo [{'count': 6, 'manufacturer': 'Bonus', 'model': 'B44/600', 'source_id': 'vbk-20261103-2235-layer-5'}]
Trianel Windpark Görzig [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N149 4,0-4,5', 'source_id': 'mastr-wind-20261103-bb'}]
Prästkila [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V112', 'source_id': 'vbk-20261103-2235-layer-12'}]
Kövlinge [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-2135-layer-5'}]
CEE Windpark Haunetal [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V150-4.2 MW', 'source_id': 'mastr-wind-20261103-he'}]
Torseröds Vindkraftpark 6 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Reslövsgården [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E40/500', 'source_id': 'vbk-20261103-2035-layer-5'}, {'count': 2, 'manufacturer': 'Enercon', 'model': 'E53/800', 'source_id': 'vbk-20261103-2035-layer-5'}]
Sjömåla [{'count': 5, 'manufacturer': 'Enercon', 'model': 'E-92', 'source_id': 'vbk-20261103-1635-layer-12'}, {'count': 1, 'manufacturer': 'Enercon', 'model': 'E-92', 'source_id': 'vbk-20261103-1635-layer-7'}]
Vitåkra [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Prezelle Nord [{'count': 5, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V162-6.2', 'source_id': 'mastr-wind-20261103-ni'}]
Lyckås [{'count': 13, 'manufacturer': 'Vestas', 'model': 'V150-4.5 MW', 'source_id': 'vbk-20261103-1535-layer-5'}]
Windpark Birstein [{'count': 9, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 162-6.0', 'source_id': 'mastr-wind-20261103-he'}]
Eskilsäters-Boda [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E73', 'source_id': 'vbk-20261103-2335-layer-5'}]
Vänervind [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Lovene [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Mats Eriksson vindkraftverk 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-layer-5'}]
Kroka 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52b', 'source_id': 'vbk-20261103-1735-layer-5'}]
Rödjans vindkraftverk [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W2700', 'source_id': 'vbk-20261103-2235-layer-9'}]
Borringe 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Bure 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E44/600', 'source_id': 'vbk-20261104-0535-layer-9'}]
Byåra [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Franzenheim [{'count': 8, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175', 'source_id': 'mastr-wind-20261103-rp'}]
Vindpark Ekeby [{'count': 3, 'manufacturer': 'Senvion', 'model': 'MM100-2.0', 'source_id': 'vbk-20261104-0035-layer-5'}]
Dållebo [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V150-4.5 MW', 'source_id': 'vbk-20261103-2235-layer-5'}]
Ruuthsbo I [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-2035-layer-5'}]
Rute Furillen Slitevind XI & XII [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-1835-layer-9'}]
Styrshult [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Ingel 3 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V29', 'source_id': 'vbk-20261103-2035-layer-5'}]
Sanden [{'count': 1, 'manufacturer': 'Winworld', 'model': 'W-5200 OSC', 'source_id': 'vbk-20261103-2235-layer-9'}]
Gummaråsen [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Winterberg-Altenfeld [{'count': 3, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 5.5-158 Cypress', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Steinbacher Höhe [{'count': 3, 'manufacturer': 'REpower Systems SE', 'model': 'REpower MM92', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Illmensee - Sturmberg [{'count': 2, 'manufacturer': 'Nordex SE', 'model': 'Nordex N54-Mk1', 'source_id': 'mastr-wind-20261103-bw'}, {'count': 1, 'manufacturer': 'Nordex SE', 'model': 'Nordex N54 - Mk1', 'source_id': 'mastr-wind-20261103-bw'}]
Näsbyholm [{'count': 4, 'manufacturer': 'Enercon', 'model': 'E70/2300', 'source_id': 'vbk-20261103-2035-layer-5'}]
Normlösa Torpa Vind [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Norra vedbo (Jönköping/Aneby) [{'count': 20, 'manufacturer': 'Vestas', 'model': 'V150', 'source_id': 'vbk-20261103-1535-layer-5'}]
Åndberget [{'count': 53, 'manufacturer': 'Nordex', 'model': 'N149', 'source_id': 'vbk-20261104-0435-layer-5'}]
Windpark Großhänchen [{'count': 4, 'manufacturer': 'DeWind GmbH', 'model': 'D8', 'source_id': 'mastr-wind-20261103-sn'}]
Trattberget, Skallberget. [{'count': 30, 'manufacturer': 'Siemens', 'model': 'SWT-2.3-101', 'source_id': 'vbk-20261104-0335-layer-5'}]
Brickan (Svegström) [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2,0', 'source_id': 'vbk-20261104-0435-layer-5'}]
Klockartorp 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2235-layer-5'}]
WindFloat Atlantic [{'count': 3, 'equipment_record_id': '401ece75-5151-51d1-9bb2-76b683e88a6d', 'manufacturer': 'MHI Vestas Offshore Wind', 'model': 'V164-8.4 MW', 'source_id': 'v164-84', 'unit_rating_kw': 8400}]
Södra Bäckebo [{'count': 1, 'manufacturer': 'DVT', 'model': 'DVT Tellus T-1995', 'source_id': 'vbk-20261103-1735-layer-5'}]
Hällemöllan I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V29', 'source_id': 'vbk-20261103-2235-layer-5'}]
Alcocero de Mola [{'count': 13, 'hub_height_m': 115, 'inventory_basis': 'Complete proposed model/count; not as-built inventory', 'manufacturer': 'Goldwind', 'model': 'Goldwind GW-165', 'rotor_diameter_m': 165, 'source_id': 'BOE-A-2026-18635', 'unit_rating_mw': 6}]
Windpark Klein Westerhausen [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163/6.X', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Lehrte-Ahlten [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-ni'}]
Varby [{'count': 2, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1135-layer-5'}]
L+W Windkraft GmbH & Co Solzer Windpark KG []
Valla Vind [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Vitberget V2 [{'count': 3, 'manufacturer': 'Nordex', 'model': 'N163/6.X', 'source_id': 'vbk-20261104-0335-layer-5'}, {'count': 1, 'manufacturer': 'Nordex', 'model': 'N163/6.X', 'source_id': 'vbk-20261104-0335-layer-12'}]
Jung-Åsa [{'count': 6, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Seglaberga 4 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE39', 'source_id': 'vbk-20261103-2135-layer-5'}]
Ängalid III & Torsnäs, Torrlösa [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2035-layer-5'}]
Iglasjön [{'count': 8, 'manufacturer': 'Vestas', 'model': 'V112', 'source_id': 'vbk-20261103-2135-layer-5'}]
Gunnön [{'count': 3, 'manufacturer': 'Vestas', 'model': 'VE47', 'source_id': 'vbk-20261103-1935-layer-5'}]
Windpark Nordwalde [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N149', 'source_id': 'mastr-wind-20261103-nw'}]
Dömestorp I [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-2135-layer-5'}]
Raftsjöhöjden syd [{'count': 4, 'manufacturer': 'Siemens', 'model': 'SWT 101', 'source_id': 'vbk-20261104-0435-layer-5'}]
Hellvi Stengrinde [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1835-layer-5'}]
Lys-Vind [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW37', 'source_id': 'vbk-20261103-2235-layer-5'}]
Lårstad 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Münsterwald GmbH & Co. KG [{'count': 7, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V112', 'source_id': 'mastr-wind-20261103-nw'}]
Adelövs Lantbruk [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W-2920/250', 'source_id': 'vbk-20261103-1535-layer-5'}]
Windpark Möbisburg GmbH & Co. KG [{'count': 8, 'manufacturer': 'ENERCON GmbH', 'model': 'E70 E4', 'source_id': 'mastr-wind-20261103-th'}, {'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'Enercon E-70 E4', 'source_id': 'mastr-wind-20261103-th'}]
Windpark Hohenzellig [{'count': 8, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N117/2400', 'source_id': 'mastr-wind-20261103-by'}]
Håberg 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
LEJDEBERGEN [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Uvereds Vindkraftförening [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V52/850', 'source_id': 'vbk-20261103-2235-layer-5'}]
Brunnstorp I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Illmersdorf [{'count': 2, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163-5.7 MW STE', 'source_id': 'mastr-wind-20261103-bb'}, {'count': 2, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163-5.7 MW', 'source_id': 'mastr-wind-20261103-bb'}, {'count': 1, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163-5.7 MW STE', 'source_id': 'mastr-wind-20261103-bb'}]
Skåramåla [{'count': 8, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 170-6,2', 'source_id': 'vbk-20261103-1635-layer-5'}]
Rågåkra [{'count': 2, 'manufacturer': 'Senvion', 'model': '3,2M114', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Birkholzgrund West [{'count': 5, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175-6.8 MW', 'source_id': 'mastr-wind-20261103-bb'}]
Windpark Halvesbostel [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'Enercon E115', 'source_id': 'mastr-wind-20261103-ni'}]
Mariedal I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Fäbodliden [{'count': 24, 'manufacturer': 'Vestas', 'model': 'V112-3.3', 'source_id': 'vbk-20261104-0535-layer-5'}]
Sundsholm [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC82', 'source_id': 'vbk-20261103-2235-layer-5'}]
RANÅKER / 747 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE472', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Grebenau [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N131/3300', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Platte Bracht [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2-HST-162-FB-C-01', 'source_id': 'mastr-wind-20261103-nw'}]
St Levene [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Dömestorp II [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM52', 'source_id': 'vbk-20261103-2135-layer-5'}]
Storberget [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V90-1.8', 'source_id': 'vbk-20261104-0535-layer-5'}]
Västanby gård [{'count': 2, 'manufacturer': 'NEG Micon', 'model': 'NM48', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Gau-Odernheim []
Brattön [{'count': 6, 'manufacturer': 'Nordex', 'model': 'N90/2500', 'source_id': 'vbk-20261103-2235-layer-5'}]
Medhamra 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1135-layer-5'}]
Assjö 1, Ella [{'count': 2, 'manufacturer': 'Suzlon', 'model': 'S88', 'source_id': 'vbk-20261103-1535-layer-5'}]
Windpark Uhler [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V-90', 'source_id': 'mastr-wind-20261103-rp'}]
Windpark Hohen Niendorf [{'count': 3, 'manufacturer': 'AN Windenergie GmbH', 'model': 'AN Bonus 600kW/41', 'source_id': 'mastr-wind-20261103-mv'}, {'count': 1, 'manufacturer': 'AN Windenergie GmbH', 'model': 'AN Bonus 600', 'source_id': 'mastr-wind-20261103-mv'}, {'count': 1, 'manufacturer': 'AN Windenergie GmbH', 'model': 'AN Bonus 450kW/37', 'source_id': 'mastr-wind-20261103-mv'}]
Windpark Brand-Erbisdorf [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175-6.8 MW', 'source_id': 'mastr-wind-20261103-sn'}, {'count': 1, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163-6.8 MW', 'source_id': 'mastr-wind-20261103-sn'}]
Munkhyttan [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V162', 'source_id': 'vbk-20261104-0035-layer-5'}]
Windpark Rohrberg [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-115', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Vechta-Telbrake [{'count': 6, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163/6.X TCS164', 'source_id': 'mastr-wind-20261103-ni'}]
Grupp Brotorp [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Uddared [{'count': 9, 'manufacturer': 'GE Wind Energy', 'model': 'GE 2.5-103', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark GmbH & Co. Penzlin KG [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-53', 'source_id': 'mastr-wind-20261103-mv'}]
Windpark Uthuisen [{'count': 4, 'manufacturer': 'GE Wind Energy GmbH', 'model': '3.2-130-110', 'source_id': 'mastr-wind-20261103-nw'}]
Energiepark Beckum [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'VESTAS V172-7.2', 'source_id': 'mastr-wind-20261103-nw'}]
Järmunderöd [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Genneved [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Herßum [{'count': 6, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Hohenstein [{'count': 3, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 2.5 120', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Jansen GbR [{'count': 3, 'manufacturer': 'Tacke GmbH & Co. KG', 'model': 'TW 600', 'source_id': 'mastr-wind-20261103-ni'}]
Trosaskogen [{'count': 1, 'manufacturer': 'WindEn', 'model': '45', 'source_id': 'vbk-20261103-layer-5'}]
Hitra 2 [{'boundary': 'Cohort only; exact OEM configuration revision and individual IDs unknown', 'commissioning_date': '2019-09-02', 'count': 25, 'manufacturer': 'Vestas', 'model': 'V117-3.6', 'source_id': 'nve-wind-api-20261108', 'unit_rating_kw': 3600}, {'boundary': 'Cohort only; exact OEM configuration revision and individual IDs unknown', 'commissioning_date': '2019-11-19', 'count': 1, 'manufacturer': 'Vestas', 'model': 'V117-3.6', 'source_id': 'nve-wind-api-20261108', 'unit_rating_kw': 3600}]
Hällevadsholm 2 och 3 [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82-2.3', 'source_id': 'vbk-20261103-2235-layer-5'}]
Krokek [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Bühnerbach [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'Nordex N149/4.0-4.5/TS125', 'source_id': 'mastr-wind-20261103-ni'}]
Mossgård [{'count': 1, 'manufacturer': 'GE Wind Energy', 'model': 'GE 1.6 - 100 96HH', 'source_id': 'vbk-20261103-1535-layer-5'}]
Fasikan [{'count': 15, 'manufacturer': 'Nordex', 'model': 'N163/6.X', 'source_id': 'vbk-20261104-0435-layer-5'}]
Boarp [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V162-6.2', 'source_id': 'vbk-20261103-1535-layer-5'}]
Helan Hovby [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V47/660', 'source_id': 'vbk-20261103-2035-layer-5'}]
Örken [{'count': 6, 'manufacturer': 'Vestas', 'model': 'V112-3.0', 'source_id': 'vbk-20261103-2135-layer-5'}]
Råshön [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261104-0435-layer-5'}, {'count': 7, 'manufacturer': 'Vestas', 'model': 'V82', 'source_id': 'vbk-20261104-0435-layer-5'}]
Gunnarby [{'count': 8, 'manufacturer': 'Siemens', 'model': 'SWT-2.3-113', 'source_id': 'vbk-20261103-2235-layer-5'}]
Hibridación FV-PEol Salinas I [{'base_model_record_id': '3b8f4149-6b7a-5cb3-ae27-3f0b39972010', 'configuration_crosswalk': None, 'count': 8, 'inventory_basis': 'Complete proposed8-unit fleet; no as-built verification', 'locator': 'Description of installations', 'manufacturer': 'Vestas', 'model': 'V163-4.5 MW-118HH', 'source_id': 'BOE-B-2026-29434', 'unit_rating_kw': 4500}]
Lyse Bonus [{'count': 1, 'manufacturer': 'Bonus', 'model': 'AN Bonus 450/35', 'source_id': 'vbk-20261103-2235-layer-5'}]
Skeby Vind [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Boyal I repowering [{'count': 1, 'hub_height_m': 127.5, 'inventory_basis': 'Complete proposed model/count; not as-built inventory', 'manufacturer': 'Siemens Gamesa', 'model': 'Siemens Gamesa SG 5-145', 'rotor_diameter_m': 145, 'source_id': 'BOE-A-2026-18694', 'unit_rating_mw': 5}]
Råbelöv [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-2035-layer-5'}]
Silvia af [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'MI5', 'source_id': 'vbk-20261103-layer-5'}]
Skalleberg och Dunabolet [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V100', 'source_id': 'vbk-20261103-2235-layer-5'}]
Väderstad Vind [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Skog 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Bjälbo Lennart [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC406', 'source_id': 'vbk-20261103-1135-layer-5'}]
Järnäsklubb vindkraftstation [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE47', 'source_id': 'vbk-20261104-0535-layer-5'}]
Uvberget Hanna [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261104-0135-layer-5'}]
Storön [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V52-850', 'source_id': 'vbk-20261104-0635-layer-5'}]
Windpark Wesermündung (Sellstedt) [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'Enercon E-70/20.71', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Freckenfeld [{'count': 6, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N 131-3.3', 'source_id': 'mastr-wind-20261103-rp'}]
Mammarp [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-2135-layer-5'}]
Bardy [{'configuration_scope': 'Project model label; not equated to a different rating/revision in equipment catalogue', 'count': 25, 'locator': 'Main project detail: headline quantities, launch/implementation observation and project description', 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'pne_bardy_detail'}]
Ekelunda [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E52', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark Westoverledingen [{'count': 7, 'manufacturer': 'ENERCON GmbH', 'model': 'E82 E2', 'source_id': 'mastr-wind-20261103-ni'}]
CEE Windpark Klein Lobke [{'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E70 E4', 'source_id': 'mastr-wind-20261103-ni'}, {'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-70 E4', 'source_id': 'mastr-wind-20261103-ni'}]
Mörkagården 4 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Knöstad [{'count': 8, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 6.2-170', 'source_id': 'vbk-20261103-2335-layer-5'}, {'count': 1, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 5.8-170', 'source_id': 'vbk-20261103-2335-layer-12'}]
Vinninge [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2035-layer-5'}]
Askegården [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1135-layer-12'}]
Windpark Neuhof [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V-126 3.3 MW', 'source_id': 'mastr-wind-20261103-by'}]
Överhallen [{'count': 1, 'manufacturer': 'Wincon', 'model': 'W99 XT', 'source_id': 'vbk-20261104-0435-layer-5'}]
Falkenbergsporten 3 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE472', 'source_id': 'vbk-20261103-2135-layer-5'}]
Hällvadsholm [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Erikstads-Mossebol 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Lutzhöft [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N133-4.8', 'source_id': 'mastr-wind-20261103-sh'}]
Ventlinge [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V27/225kw, 50Hz', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark Üchtelhausen [{'count': 6, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V172-7.2MW', 'source_id': 'mastr-wind-20261103-by'}]
Vindön [{'count': 12, 'manufacturer': 'Vestas', 'model': 'V42', 'source_id': 'vbk-20261103-2035-layer-5'}]
Nyland [{'count': 1, 'manufacturer': 'JBA', 'model': 'CellPart', 'source_id': 'vbk-20261104-0335-layer-5'}]
Windpark Nohfelden-Eisen [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V126/3.3', 'source_id': 'mastr-wind-20261103-sl'}]
Bürgerwindpark Kleinenberg [{'count': 7, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E1', 'source_id': 'mastr-wind-20261103-nw'}]
Hangvar Kyrkebys 2 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-1835-layer-5'}]
Högby 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Kloddram [{'count': 9, 'manufacturer': 'Siemens Wind Power GmbH & Co. KG', 'model': 'Siemens SWT-DD-142', 'source_id': 'mastr-wind-20261103-mv'}]
3952 Tomten [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Wippershainer Höhe [{'count': 8, 'manufacturer': 'Nordex Germany GmbH', 'model': 'Nordex N163 / 6.X', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Niederlungwitz [{'count': 8, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas EnVentus V162-6.2 MW', 'source_id': 'mastr-wind-20261103-sn'}]
Skogberget [{'count': 36, 'manufacturer': 'Enercon', 'model': 'E92/2.3', 'source_id': 'vbk-20261104-0635-layer-5'}]
Klinte Strands Isak [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-1835-layer-5'}]
Mungseröd/Gurseröd/Skaveröd [{'count': 8, 'manufacturer': 'Vestas', 'model': 'V100', 'source_id': 'vbk-20261103-2235-layer-5'}]
Lörby 6 Lörby/Ysane [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1935-layer-5'}]
Klackeborg [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1135-layer-5'}]
Ingel 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V29', 'source_id': 'vbk-20261103-2035-layer-5'}]
Havsnäs [{'count': 47, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261104-0435-layer-5'}, {'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261104-0435-layer-9'}]
Windpark Kreuzstein [{'count': 8, 'manufacturer': 'ENERCON GmbH', 'model': 'E-115', 'source_id': 'mastr-wind-20261103-he'}]
Västrabygård [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V80', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Siegen-Kreuzeiche [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-160 EP5 E3 R1', 'source_id': 'mastr-wind-20261103-nw'}]
Tunhem 3 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Billroda [{'count': 5, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175-6.8 MW', 'source_id': 'mastr-wind-20261103-st'}]
Windpark Trier-Wetterborn [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'Nordex N163/6.X', 'source_id': 'mastr-wind-20261103-rp'}]
Windpark Haltern [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V162 - 6,0 MW', 'source_id': 'mastr-wind-20261103-nw'}]
Fingal af Boberg [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1135-layer-5'}]
Vindpark Fallåsberget [{'count': 10, 'manufacturer': 'Siemens', 'model': 'SWT101', 'source_id': 'vbk-20261104-0235-layer-5'}]
Appeltorp [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2035-layer-5'}]
Stöllsäterberget [{'count': 8, 'manufacturer': 'Nordex', 'model': 'N163/5.X', 'source_id': 'vbk-20261103-2335-layer-5'}]
Skepared [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Hünfeldener Wald II [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175', 'source_id': 'mastr-wind-20261103-he'}]
Andersfält Syd [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2135-layer-5'}]
Ruuthsbo-Kärragården [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Rollshausen [{'count': 5, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N149-4.5 MW', 'source_id': 'mastr-wind-20261103-ni'}]
Äspinge-Klemedstorp [{'count': 4, 'manufacturer': 'Enercon', 'model': 'E82/2000', 'source_id': 'vbk-20261103-2035-layer-5'}]
Månstorps Gård [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW375', 'source_id': 'vbk-20261103-2135-layer-5'}]
Aapua Vindpark [{'count': 7, 'manufacturer': 'Vestas', 'model': 'NM82', 'source_id': 'vbk-20261104-0635-layer-5'}]
Windpark Hellenthal Kehr [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-66', 'source_id': 'mastr-wind-20261103-nw'}]
meridian Windpark Thonhausen [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N117-2,4MW', 'source_id': 'mastr-wind-20261103-th'}]
Isiegården [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM48/750', 'source_id': 'vbk-20261103-2035-layer-5'}]
Långmarken [{'count': 8, 'manufacturer': 'Vestas', 'model': 'V126 3,3', 'source_id': 'vbk-20261103-2335-layer-5'}]
Bessakerfjellet [{'boundary': 'registry cohort; exact OEM revision unresolved', 'commissioning_date': '2008-08-30', 'count': 13, 'manufacturer': 'Enercon', 'model': 'E-70', 'rated_power_kw': 2300, 'source_id': 'nve-wind-api-20261108'}, {'boundary': 'registry cohort; exact OEM revision unresolved', 'commissioning_date': '2007-09-10', 'count': 12, 'manufacturer': 'Enercon', 'model': 'E-70', 'rated_power_kw': 2300, 'source_id': 'nve-wind-api-20261108'}]
Uvberget Boel [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V54', 'source_id': 'vbk-20261104-0135-layer-5'}]
Windpark Loxter Ort [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E175 E5 EP2', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Skassa [{'count': 6, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175-6.8 MW', 'source_id': 'mastr-wind-20261103-sn'}]
Idhult [{'count': 8, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark Burgholz [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 126-3.3', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Mengerskirchen [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N-117', 'source_id': 'mastr-wind-20261103-he'}]
Betåsberget [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261104-0435-layer-5'}]
Björkön [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE44', 'source_id': 'vbk-20261104-0335-layer-5'}]
Torkelsrud [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Almudden [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261104-0035-layer-5'}]
Topperyd 1 och 2 [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90 2,0 MW', 'source_id': 'vbk-20261103-1535-layer-5'}]
Köjkeberget [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261104-0135-layer-5'}]
vkv_lin-014 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1135-layer-5'}]
Rosendal 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE27', 'source_id': 'vbk-20261103-2135-layer-5'}]
Torekull Mr trend 9001 [{'count': 2, 'manufacturer': 'Vestas', 'model': 'VE27', 'source_id': 'vbk-20261103-2135-layer-9'}]
Millingstorp I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Roes [{'count': 4, 'manufacturer': 'Tacke GmbH & Co. KG', 'model': 'GEWE K600', 'source_id': 'mastr-wind-20261103-rp'}]
Mörkagården 3 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Olseröd [{'count': 1, 'manufacturer': 'Bonus', 'model': '600/44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Boyal II repowering [{'count': 1, 'hub_height_m': 127.5, 'inventory_basis': 'Complete proposed model/count; not as-built inventory', 'manufacturer': 'Siemens Gamesa', 'model': 'Siemens Gamesa SG 5-145', 'rotor_diameter_m': 145, 'source_id': 'BOE-A-2026-18695', 'unit_rating_mw': 5}]
Kyleberg [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Stureholms Gård [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W2700', 'source_id': 'vbk-20261103-2035-layer-9'}]
Dalaholm I [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Vena [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Kaptensberget [{'count': 4, 'manufacturer': 'Siemens', 'model': 'SWT-2.3-101', 'source_id': 'vbk-20261104-0235-layer-5'}]
Vallsås [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Fanbyn [{'count': 8, 'manufacturer': 'Vestas', 'model': 'V47-660', 'source_id': 'vbk-20261104-0335-layer-5'}]
Hibridación FV-PEol Salinas II [{'base_model_record_id': '3b8f4149-6b7a-5cb3-ae27-3f0b39972010', 'configuration_crosswalk': None, 'count': 8, 'inventory_basis': 'Complete proposed8-unit fleet; no as-built verification', 'locator': 'Description of installations', 'manufacturer': 'Vestas', 'model': 'V163-4.5 MW-118HH', 'source_id': 'BOE-B-2026-29433', 'unit_rating_kw': 4500}]
CEE Windpark Kuhbett [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E 115', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Willerswalde [{'count': 1, 'manufacturer': 'eno energy GmbH', 'model': 'eno 140 - 4.2 MW', 'source_id': 'mastr-wind-20261103-mv'}, {'count': 3, 'manufacturer': 'eno energy GmbH', 'model': 'eno 126', 'source_id': 'mastr-wind-20261103-mv'}]
Brodderud [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2OOO', 'source_id': 'vbk-20261103-2235-layer-12'}]
Långberget 2 [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261104-0235-layer-5'}]
Windpark Ottweiler-Höcherberg [{'count': 5, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V126 3.3 MW', 'source_id': 'mastr-wind-20261103-sl'}]
Vivian [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE27', 'source_id': 'vbk-20261103-1535-layer-9'}, {'count': 1, 'manufacturer': 'Vestas', 'model': 'V44', 'source_id': 'vbk-20261103-1535-layer-5'}]
Energiepark Waldenrath [{'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N117/2400/R91', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N100/2500', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N117/2400R91', 'source_id': 'mastr-wind-20261103-nw'}]
Långeryd II [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Vindpark Vänern [{'count': 10, 'manufacturer': 'WinWind', 'model': 'WWD-3', 'source_id': 'vbk-20261103-2335-layer-5'}]
Bråtaparken [{'count': 1, 'manufacturer': 'WinWind', 'model': 'Sinovel SL3000', 'source_id': 'vbk-20261103-2235-layer-7'}]
Energiepark Bad Lauchstädt [{'count': 8, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V162', 'source_id': 'mastr-wind-20261103-st'}]
Bure 2 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E44/600', 'source_id': 'vbk-20261104-0535-layer-9'}]
Lörby 1 Toke [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC406', 'source_id': 'vbk-20261103-1935-layer-5'}]
Stockebäck I [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Tungelunda - Skeby 3 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Ryda [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Backmöllan [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Viscaria 6 [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM52', 'source_id': 'vbk-20261104-0635-layer-5'}]
Windpark Greifenhain [{'count': 10, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V90 2.0 MW MK1-6', 'source_id': 'mastr-wind-20261103-bb'}]
Väskinde Skäggs 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V47', 'source_id': 'vbk-20261103-1835-layer-5'}]
Windpark Bühlerzell [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-160 EP5 E3', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Etzean [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V162 - 6.2', 'source_id': 'mastr-wind-20261103-he'}]
Häckenäs II [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE44', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Sinz [{'count': 4, 'manufacturer': 'Nordex SE', 'model': 'Nordex N163', 'source_id': 'mastr-wind-20261103-sl'}]
Windpark Wemdinger Buck [{'count': 5, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V172', 'source_id': 'mastr-wind-20261103-by'}]
Windpark Bayerischer Odenwald [{'count': 5, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N117', 'source_id': 'mastr-wind-20261103-by'}]
Dragabol [{'count': 1, 'manufacturer': 'Nordic', 'model': 'NC10c', 'source_id': 'vbk-20261103-2135-layer-5'}]
Stavhälla [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-layer-5'}]
Trelleborgs Hamn [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E-82 E4', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Münsingen [{'count': 3, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'NEG Micon NM 48/750', 'source_id': 'mastr-wind-20261103-bw'}]
Hedagården [{'count': 6, 'manufacturer': 'Enercon', 'model': 'E66', 'source_id': 'vbk-20261103-2035-layer-5'}]
Odarslöv [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E70/2000', 'source_id': 'vbk-20261103-2035-layer-5'}]
Björnsgård [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-2135-layer-5'}]
Hovby [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V47/660', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Simmerath GmbH & Co. KG [{'count': 7, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V-112', 'source_id': 'mastr-wind-20261103-nw'}]
Kåphult Vindkraftpark [{'count': 7, 'manufacturer': 'GE Wind Energy', 'model': '2,5XL', 'source_id': 'vbk-20261103-2135-layer-5'}]
Stenkulla [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Cappeln [{'count': 1, 'manufacturer': 'Nordex SE', 'model': 'N131/3.300', 'source_id': 'mastr-wind-20261103-ni'}, {'count': 2, 'manufacturer': 'Nordex SE', 'model': 'N 131/3.300', 'source_id': 'mastr-wind-20261103-ni'}]
Vinliden [{'count': 11, 'manufacturer': 'Vestas', 'model': 'V162-6.4', 'source_id': 'vbk-20261104-0535-layer-5'}]
Hovgården Stavlösa [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V52- 850', 'source_id': 'vbk-20261103-1135-layer-5'}]
Simris1 [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V27', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Külsheim [{'count': 5, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N117', 'source_id': 'mastr-wind-20261103-bw'}]
Ö. Karaby [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Elvinda, Rocklunda [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Västergården 1 [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V90-1', 'source_id': 'vbk-20261103-2235-layer-5'}]
Slitevind Rynge [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-2035-layer-5'}]
Lårstad 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Kleinlohma [{'count': 8, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163 / 6800', 'source_id': 'mastr-wind-20261103-th'}]
Triton Energi [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Nienhagen [{'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E-70 E-4', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-70', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Polsingen [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E175-7.0', 'source_id': 'mastr-wind-20261103-by'}]
Vånga Hed 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Ängsholm [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Fretzdorfer Heide [{'count': 13, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N 163/6X', 'source_id': 'mastr-wind-20261103-bb'}]
Borrud 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2000', 'source_id': 'vbk-20261103-2235-layer-12'}]
Bäck [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2000', 'source_id': 'vbk-20261103-2235-layer-12'}]
Mjällby Ellen [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-1935-layer-5'}]
Värpinge [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V27', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Neuvrees I [{'count': 7, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-ni'}]
Väskinde Skäggs 3 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V47', 'source_id': 'vbk-20261103-1835-layer-5'}]
Windpark Mönkeloh [{'count': 2, 'manufacturer': 'ENERCON GmbH', 'model': 'E-53', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E-82', 'source_id': 'mastr-wind-20261103-nw'}]
Eifel-Windpark Tondorf [{'count': 7, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Werningshausen I [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175-6.8 MW', 'source_id': 'mastr-wind-20261103-th'}]
Windpark Milte [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V162', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V172', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Göllheim [{'count': 5, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 2.5-120', 'source_id': 'mastr-wind-20261103-rp'}]
Räpplinge [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V-90', 'source_id': 'vbk-20261103-1735-layer-5'}]
Vindpark Ljungbyholm [{'count': 8, 'manufacturer': 'Nordex', 'model': 'N149', 'source_id': 'vbk-20261103-1735-layer-5'}]
Önnestad [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V29', 'source_id': 'vbk-20261103-2035-layer-9'}]
Windpark Bergen [{'count': 1, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'NEG Micon NM 48 / 750', 'source_id': 'mastr-wind-20261103-ni'}, {'count': 4, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'NEG Micon NM 52 / 900', 'source_id': 'mastr-wind-20261103-ni'}]
Vanstad Kommungård [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM48', 'source_id': 'vbk-20261103-2035-layer-5'}]
Årjäng SV [{'count': 13, 'manufacturer': 'Vestas', 'model': 'V112', 'source_id': 'vbk-20261103-2335-layer-5'}, {'count': 1, 'manufacturer': 'Vestas', 'model': 'V112', 'source_id': 'vbk-20261103-2335-layer-12'}]
Qvantenburg 2 [{'count': 3, 'manufacturer': 'Enercon', 'model': 'EC82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Friedberg [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 90-2.0', 'source_id': 'mastr-wind-20261103-he'}]
NYCKELTORP / 7308-2 [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Hulda [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE29', 'source_id': 'vbk-20261103-2235-layer-9'}]
Glysbyn [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Ramsåsa [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E48/800', 'source_id': 'vbk-20261103-2035-layer-5'}, {'count': 1, 'manufacturer': 'Enercon', 'model': 'E44/600', 'source_id': 'vbk-20261103-2035-layer-5'}, {'count': 1, 'manufacturer': 'Enercon', 'model': 'E53/800', 'source_id': 'vbk-20261103-2035-layer-5'}]
Bürgerwindpark Schleiden [{'count': 6, 'manufacturer': 'ENERCON GmbH', 'model': 'E-101', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Rot am See [{'count': 1, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V126', 'source_id': 'mastr-wind-20261103-bw'}, {'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 126-3.3', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Mechernich Voißel [{'count': 4, 'manufacturer': 'Fuhrländer AG', 'model': 'MD 70', 'source_id': 'mastr-wind-20261103-nw'}]
Åsens säteri [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Bernsdorf [{'count': 3, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'NM60-1000', 'source_id': 'mastr-wind-20261103-sn'}]
Skäppentorp [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V112', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark Stocksol [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-160 EP5 E3 R1', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Postlow-Blesewitz [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175-6.8 MW', 'source_id': 'mastr-wind-20261103-mv'}]
TL Vind 1 [{'count': 1, 'manufacturer': 'Kenersys', 'model': 'K100', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Siegfriedeiche [{'count': 6, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 2.75-120', 'source_id': 'mastr-wind-20261103-he'}]
Nolåsen [{'count': 1, 'manufacturer': 'NTK', 'model': '55/15', 'source_id': 'vbk-20261103-2235-layer-5'}]
KARSTORP / 7044-3 [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-2235-layer-5'}]
Viscaria 4 [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM52', 'source_id': 'vbk-20261104-0635-layer-5'}]
Windpark Görgenhof [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-40 / 5.40', 'source_id': 'mastr-wind-20261103-rp'}]
Kedumsvik [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE27', 'source_id': 'vbk-20261103-2235-layer-9'}]
Östest-Kröket [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261104-0435-layer-5'}]
Windpark Nordkamp [{'count': 6, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V172-7.2 NH 164 m', 'source_id': 'mastr-wind-20261103-ni'}]
Hällunda-Timmele [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E-138', 'source_id': 'vbk-20261103-2235-layer-7'}]
Ollebacken etapp 1 [{'count': 6, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261104-0435-layer-5'}]
Rynge III [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Värestorps Vind [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW290', 'source_id': 'vbk-20261103-2135-layer-5'}]
Hjällö [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM52/900', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Harzkopf [{'count': 6, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N-117', 'source_id': 'mastr-wind-20261103-he'}]
Mörkagården 2 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Bonnarp [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW27', 'source_id': 'vbk-20261103-2135-layer-9'}]
Neosho Wind Farm [{'count': 115, 'equipment_record_id': '03fcc667-8240-5154-a982-26803f9560d9', 'manufacturer': 'Vestas', 'model': 'V120-2.2 MW', 'source_id': 'vestas-neosho', 'unit_rating_kw': 2200}, {'count': 24, 'equipment_record_id': '43a08b55-22a3-560c-819d-aa2a7c4a23a7', 'manufacturer': 'Vestas', 'model': 'V110-2.0 MW', 'source_id': 'vestas-neosho', 'unit_rating_kw': 2000}]
Boel [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V80', 'source_id': 'vbk-20261103-2035-layer-9'}]
Råby [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}, {'count': 1, 'manufacturer': 'Vestas', 'model': 'VE47', 'source_id': 'vbk-20261103-1135-layer-5'}]
Naturbruksgymn Strömmaskolan [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E-230', 'source_id': 'vbk-20261103-2235-layer-5'}]
Äng-EL [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW290', 'source_id': 'vbk-20261103-2135-layer-5'}]
Almedal [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2135-layer-5'}]
Vilseberga [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V100', 'source_id': 'vbk-20261103-1135-layer-5'}]
Bränneriet [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE29', 'source_id': 'vbk-20261103-2235-layer-9'}]
St Herrestad I [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E40/500', 'source_id': 'vbk-20261103-2035-layer-5'}]
Risberga Skogslund Vind 1 [{'count': 1, 'manufacturer': 'Wincon', 'model': 'Windon 10kW', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Burglengenfeld [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V172 7,2 MW', 'source_id': 'mastr-wind-20261103-by'}]
Bränna [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Großer Wald Hettingen/Rinschheim [{'count': 5, 'manufacturer': 'REpower Systems SE', 'model': '3.2M114', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Halsberg [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V162', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Winterbach [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N 131-3300', 'source_id': 'mastr-wind-20261103-bw'}]
Elawan Manzanares Híbrido [{'configuration_scope': 'Proposed site configuration; nominal 7.2 MW limited to 6 MW, OEM revision unknown', 'count': 6, 'manufacturer': 'Vestas', 'model': 'V172-7.2', 'source_id': 'BOE-B-2026-10173'}]
Axelsvik 1 [{'count': 2, 'manufacturer': 'Nordex', 'model': 'N90', 'source_id': 'vbk-20261104-0635-layer-5'}]
Windpark Eußenheim [{'count': 5, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175', 'source_id': 'mastr-wind-20261103-by'}]
Gislorp [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1135-layer-5'}]
Målarberget [{'count': 27, 'manufacturer': 'Vestas', 'model': 'V150', 'source_id': 'vbk-20261104-0135-layer-5'}]
Vindpark Mörkåsen [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261104-0235-layer-5'}]
Björka [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1135-layer-5'}]
Viscaria 5 [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM52', 'source_id': 'vbk-20261104-0635-layer-5'}]
Grebban 1 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE44', 'source_id': 'vbk-20261103-2235-layer-5'}]
Sotared [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Pronsfeld [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163/6.X', 'source_id': 'mastr-wind-20261103-rp'}]
Åmliden 2 [{'count': 6, 'manufacturer': 'Vestas', 'model': 'V100-1.8', 'source_id': 'vbk-20261104-0535-layer-5'}]
Värpinge Clara [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V39', 'source_id': 'vbk-20261103-2035-layer-5'}]
NEDERSÅNNA / 7042 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Alt Krenzlin I [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'ENERCON E- 138 EP 3 E2', 'source_id': 'mastr-wind-20261103-mv'}]
Kärragård [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW27', 'source_id': 'vbk-20261103-2135-layer-5'}]
Nuntorpskolans vindkraftverk [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V29', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Kirschroth [{'count': 5, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V162', 'source_id': 'mastr-wind-20261103-rp'}]
Asmundtorp [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Mången [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2335-layer-5'}]
Windpark Betzendorf GmbH & Co. KG [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Frechen [{'count': 3, 'manufacturer': 'Nordex SE', 'model': 'N149/4.0-4.5 STE, TS 125-01', 'source_id': 'mastr-wind-20261103-nw'}]
Maria [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W2700/150kw', 'source_id': 'vbk-20261103-2035-layer-5'}]
Kyrkebo I [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W2700', 'source_id': 'vbk-20261103-2235-layer-9'}]
Munkagård [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Mechernich Lukasheide-Süd [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163/6.X TS118', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163/6.X TCS164', 'source_id': 'mastr-wind-20261103-nw'}]
Stenkil [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Ascheberg-Holthoff [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N 163', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N 149', 'source_id': 'mastr-wind-20261103-nw'}]
Lörby 7 Lörby/Ysane [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-1935-layer-5'}]
Stenbrona-Saleby [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90-1', 'source_id': 'vbk-20261103-2235-layer-5'}]
Hornberget [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261104-0535-layer-5'}]
Windpark Perscheid GmbH & Co. KG [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163', 'source_id': 'mastr-wind-20261103-rp'}]
Orup [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E70', 'source_id': 'vbk-20261103-2035-layer-5'}]
Jenåsen [{'count': 23, 'manufacturer': 'Vestas', 'model': 'V126', 'source_id': 'vbk-20261104-0335-layer-5'}]
Kärrets Gård II [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Gribbohm [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-126 EP3', 'source_id': 'mastr-wind-20261103-sh'}]
Lebro [{'count': 1, 'manufacturer': 'WindEn', 'model': 'WindEn 45', 'source_id': 'vbk-20261103-layer-5'}]
Oxhult [{'count': 12, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2135-layer-5'}]
Gunn-El [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC40', 'source_id': 'vbk-20261103-2135-layer-5'}]
Kulltorp [{'count': 4, 'manufacturer': 'Nordex', 'model': 'N90/2500', 'source_id': 'vbk-20261103-1535-layer-5'}]
Klinte Vindpark [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V80', 'source_id': 'vbk-20261103-1835-layer-5'}]
Rönnerum [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E82/2000', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark RH2-PTG [{'count': 9, 'manufacturer': 'ENERCON GmbH', 'model': 'E-138 EP3 E3', 'source_id': 'mastr-wind-20261103-mv'}]
Kollbogården II [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Månsagården [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V47', 'source_id': 'vbk-20261103-2235-layer-5'}]
Sörbyparken [{'count': 37, 'manufacturer': 'Vestas', 'model': 'V117-3.3', 'source_id': 'vbk-20261104-0235-layer-5'}]
Windpark Müden (Aller) [{'count': 11, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V150 EnVentus', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Walchum [{'count': 4, 'manufacturer': 'Tacke GmbH & Co. KG', 'model': 'TW 1.5s', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Lübbinchen [{'count': 9, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V172-7.2', 'source_id': 'mastr-wind-20261103-bb'}]
Windpark Berghülen [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E 82-2.05', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Rüthen Wald [{'count': 6, 'manufacturer': 'ENERCON GmbH', 'model': 'E 175 EP5', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark GmbH & Co. Neddenaverbergen KG [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-70 E4', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Hesselertal GmbH & Co. KG [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N149', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N133', 'source_id': 'mastr-wind-20261103-nw'}]
Månsunen, Gislöv [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V29', 'source_id': 'vbk-20261103-2035-layer-9'}]
Spjutåsberget [{'count': 2, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 132', 'source_id': 'vbk-20261104-0335-layer-5'}]
Kastlösa södra [{'count': 16, 'manufacturer': 'WindWorld', 'model': 'W4200 - 600kw', 'source_id': 'vbk-20261103-1735-layer-5'}]
Hornbore [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE29', 'source_id': 'vbk-20261103-2235-layer-9'}]
Windpark Salzgitter AG [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V136 4.2MW', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Curslack [{'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N117/3.0', 'source_id': 'mastr-wind-20261103-hh'}, {'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N117/2.4', 'source_id': 'mastr-wind-20261103-hh'}]
Hangvar Kyrkebys, Kyrkebys 3 & 4 [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261103-1835-layer-5'}]
Windpark Möhnesee [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N175/6.X', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Heidhörn []
Windpark Mundersum [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E 175 EP5 E2', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Emskirchen [{'count': 3, 'manufacturer': 'REpower Systems SE', 'model': 'MM92', 'source_id': 'mastr-wind-20261103-by'}]
Dragaliden [{'count': 12, 'manufacturer': 'Enercon', 'model': 'E-82', 'source_id': 'vbk-20261104-0635-layer-5'}]
Rämsberget [{'count': 7, 'manufacturer': 'Vestas', 'model': 'V112-3,0', 'source_id': 'vbk-20261104-0135-layer-5'}]
Falkenbergsporten 4 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE472', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Plauerhagen [{'count': 6, 'manufacturer': 'eno energy GmbH', 'model': 'eno 114', 'source_id': 'mastr-wind-20261103-mv'}]
Brotorp [{'count': 14, 'manufacturer': 'Vestas', 'model': 'V126', 'source_id': 'vbk-20261103-1735-layer-5'}]
Tannam Smeby [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Lilla Tjärby Gård [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-2135-layer-5'}]
Slättäng [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V47', 'source_id': 'vbk-20261103-2035-layer-5'}, {'count': 2, 'manufacturer': 'NEG Micon', 'model': 'NM48', 'source_id': 'vbk-20261103-2035-layer-5'}]
Vallberga Gård Mölla [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W2700', 'source_id': 'vbk-20261103-2135-layer-5'}, {'count': 1, 'manufacturer': 'WindWorld', 'model': 'W4200', 'source_id': 'vbk-20261103-2135-layer-5'}]
Bösjövarden [{'count': 9, 'manufacturer': 'Nordex', 'model': 'N100', 'source_id': 'vbk-20261104-0135-layer-5'}]
Windpark Kluis-Silenz [{'count': 2, 'manufacturer': 'AN-Maschinenbau- und Umweltschutzanlagen GmbH', 'model': 'AN BONUS 600kW 44-3', 'source_id': 'mastr-wind-20261103-mv'}, {'count': 8, 'manufacturer': 'AN Windenergie GmbH', 'model': 'AN BONUS 600kW 44-3', 'source_id': 'mastr-wind-20261103-mv'}]
Frideborg [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE29', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Kanzlei [{'count': 2, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N149/5.X', 'source_id': 'mastr-wind-20261103-sh'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163/6.X', 'source_id': 'mastr-wind-20261103-sh'}]
Kadesjö [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-2035-layer-5'}]
Jordboen [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E70', 'source_id': 'vbk-20261103-2035-layer-5'}]
Slageryd [{'count': 6, 'manufacturer': 'Nordex', 'model': 'N131/3900', 'source_id': 'vbk-20261103-1535-layer-5'}]
Hermansröd [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Valterslund [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Keferloh [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V172', 'source_id': 'mastr-wind-20261103-by'}]
Vindpark Håcksta [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261104-0235-layer-5'}]
Digerberget [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'MI72C', 'source_id': 'vbk-20261104-0435-layer-5'}]
Rödjans Gård [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW27', 'source_id': 'vbk-20261103-2235-layer-5'}]
Jämjö [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W3700', 'source_id': 'vbk-20261103-1735-layer-5'}]
ENERCON Windpark GmbH & Co. Steife Briese KG [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-58/10.58', 'source_id': 'mastr-wind-20261103-st'}]
Windpark Grevenstein [{'count': 7, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163/6.X', 'source_id': 'mastr-wind-20261103-nw'}]
Ullavi [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V100-1.8', 'source_id': 'vbk-20261104-0035-layer-5'}]
Helleberg 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261103-2235-layer-5'}]
Bjäresjö [{'count': 2, 'manufacturer': 'NEG Micon', 'model': 'NM48', 'source_id': 'vbk-20261103-2035-layer-5'}]
Blakliden Vindkraftpark [{'count': 50, 'manufacturer': 'Vestas', 'model': 'V136', 'source_id': 'vbk-20261104-0535-layer-5'}]
Windpark Buchau [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V-112', 'source_id': 'mastr-wind-20261103-by'}]
Söbyn [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC82', 'source_id': 'vbk-20261103-2235-layer-5'}, {'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Muckenberg [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'Enercon E175 EP5', 'source_id': 'mastr-wind-20261103-by'}]
Lärbro Nors Norrvange Nr 1 & 2 [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-1835-layer-5'}]
Windpark Häger/Sandruper See [{'count': 3, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 3.2-130', 'source_id': 'mastr-wind-20261103-nw'}]
Vårdkasberget [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V44', 'source_id': 'vbk-20261104-0335-layer-5'}]
Windpark Hüngheim [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP-5', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Rödder [{'count': 2, 'manufacturer': 'ENERCON GmbH', 'model': 'E-160 EP5 E3', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E-138 EP3 E3', 'source_id': 'mastr-wind-20261103-nw'}]
Ånhammar [{'count': 1, 'manufacturer': 'Siemens', 'model': 'SWT-2,3-113', 'source_id': 'vbk-20261103-layer-7'}]
Häckenäs III [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Brakel West [{'count': 8, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V172-7.2 MW „EnVentus“', 'source_id': 'mastr-wind-20261103-nw'}]
Mellby Kraft I [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW42', 'source_id': 'vbk-20261103-2135-layer-5'}]
Äsperöd [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82-2.0', 'source_id': 'vbk-20261103-2035-layer-5'}]
Hällemöllan II [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V29', 'source_id': 'vbk-20261103-2235-layer-5'}]
Ängalid IV, Norra Skrävlinge [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2035-layer-5'}]
Varnäs Vind [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Hälle vindkraftverk [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W2700/150', 'source_id': 'vbk-20261103-2235-layer-5'}]
Risträsk [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261104-0535-layer-5'}]
Villköl [{'count': 7, 'manufacturer': 'Vestas', 'model': 'V112', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark Großliebringen [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'VESTAS V-172', 'source_id': 'mastr-wind-20261103-th'}, {'count': 1, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'VESTAS V-136', 'source_id': 'mastr-wind-20261103-th'}]
Kroken [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Bondön [{'count': 14, 'manufacturer': 'Nordex', 'model': 'N90/2500', 'source_id': 'vbk-20261104-0635-layer-5'}]
Klågerup [{'count': 3, 'manufacturer': 'Senvion', 'model': 'MM92', 'source_id': 'vbk-20261103-2035-layer-5'}]
Vindkraft Vårdkasen [{'count': 2, 'manufacturer': 'Nordex', 'model': 'N100', 'source_id': 'vbk-20261104-0335-layer-5'}]
Hedbodberget Etapp 1 [{'count': 15, 'manufacturer': 'Vestas', 'model': 'V90-2MW', 'source_id': 'vbk-20261104-0135-layer-5'}]
WP Lutzhöft (Altpark) [{'count': 3, 'manufacturer': 'Tacke GmbH & Co. KG', 'model': 'TW600', 'source_id': 'mastr-wind-20261103-sh'}]
Lövstaviken [{'count': 5, 'manufacturer': 'Enercon', 'model': 'E70/2300', 'source_id': 'vbk-20261103-2135-layer-5'}, {'count': 1, 'manufacturer': 'Vestas', 'model': 'VE42', 'source_id': 'vbk-20261103-2135-layer-5'}]
Rinkaby [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2035-layer-5'}]
Bossgården (Galneryd) [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V100', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Bühren-Großsander GmbH & Co. KG [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'Nordex N163/6.X TS 118', 'source_id': 'mastr-wind-20261103-ni'}]
Granberget 1 [{'count': 6, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261104-0535-layer-5'}]
Windpark Finkenbach-Gersweiler GmbH & Co. KG [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-115', 'source_id': 'mastr-wind-20261103-rp'}]
Sivik III [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'MI748', 'source_id': 'vbk-20261103-2235-layer-5'}]
Kråktorpet [{'count': 43, 'manufacturer': 'Vestas', 'model': 'V136', 'source_id': 'vbk-20261104-0335-layer-5'}]
Tolvmanstegen [{'count': 22, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Nidda-Höllberg [{'count': 7, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V172-7.2', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Embsen [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-66/18.70', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Zitz-Warchau GmbH & Co. KG [{'count': 1, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'NM64 c - 1500', 'source_id': 'mastr-wind-20261103-bb'}, {'count': 19, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'NM64c-1500', 'source_id': 'mastr-wind-20261103-bb'}]
Windpark Kalkar Wissel [{'count': 2, 'manufacturer': 'Fuhrländer AG', 'model': 'FL 1000', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Fuhrländer AG', 'model': 'MD 70', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Braunsbach [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E115', 'source_id': 'mastr-wind-20261103-bw'}, {'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E101', 'source_id': 'mastr-wind-20261103-bw'}]
Bösarp [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V27', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark am Seibertswald [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-160 EP5 E3 R1', 'source_id': 'mastr-wind-20261103-sl'}]
Si-Vind [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'WW375', 'source_id': 'vbk-20261103-2235-layer-5'}]
MUNSTORP 7043 [{'count': 1, 'manufacturer': 'Fuhrländer', 'model': 'FL25A', 'source_id': 'vbk-20261103-2235-layer-5'}]
Sötterfällan [{'count': 10, 'manufacturer': 'Vestas', 'model': 'V136', 'source_id': 'vbk-20261103-1535-layer-5'}]
Windpark Kiesenhof [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175 6.X TCS179B', 'source_id': 'mastr-wind-20261103-by'}]
Åliden - Lidenprojekten [{'count': 12, 'manufacturer': 'Nordex', 'model': 'N131', 'source_id': 'vbk-20261104-0335-layer-5'}]
Sälshög [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Roßtal [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E1', 'source_id': 'mastr-wind-20261103-by'}]
KILAGÅRDEN /7306-1 [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-2235-layer-5'}]
Viscaria 2 [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'NM52', 'source_id': 'vbk-20261104-0635-layer-5'}]
Windpark Böttingen-Buch [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5', 'source_id': 'mastr-wind-20261103-bw'}]
Hannas [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E-82', 'source_id': 'vbk-20261103-2035-layer-5'}]
Vindpark Våsberget [{'count': 8, 'manufacturer': 'Vestas', 'model': 'V117', 'source_id': 'vbk-20261104-0235-layer-5'}]
Bällefors-Kyrketorp [{'count': 1, 'manufacturer': 'NTK', 'model': '150/25', 'source_id': 'vbk-20261103-2235-layer-5'}]
Österåsen [{'count': 19, 'manufacturer': 'Vestas', 'model': 'V136', 'source_id': 'vbk-20261104-0435-layer-5'}]
Lebo [{'count': 5, 'manufacturer': 'Siemens Gamesa', 'model': 'SG-6,6-155', 'source_id': 'vbk-20261103-1735-layer-5'}]
Boberg 2 [{'count': 3, 'manufacturer': 'Siemens', 'model': 'SWT 2.3-101', 'source_id': 'vbk-20261103-1135-layer-5'}]
Munkflohögen [{'count': 23, 'manufacturer': 'Vestas', 'model': 'V110', 'source_id': 'vbk-20261104-0435-layer-5'}]
Erken [{'count': 2, 'manufacturer': 'Kenersys', 'model': 'K110 - 2.4mw', 'source_id': 'vbk-20261103-layer-5'}]
Windpark Eichede GmbH & Co. KG [{'count': 4, 'manufacturer': 'AN Windenergie GmbH', 'model': 'AN 1.3MW/62 h WTC', 'source_id': 'mastr-wind-20261103-sh'}]
Windpark Monschau GmbH & Co. KG [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-115', 'source_id': 'mastr-wind-20261103-nw'}]
Ulvstorp, Djerf [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2235-layer-5'}]
Tängelsås [{'count': 4, 'manufacturer': 'Enercon', 'model': 'E44/600', 'source_id': 'vbk-20261103-2035-layer-5'}]
Ollebacken etapp 2 [{'count': 3, 'manufacturer': 'GE Wind Energy', 'model': '5.5-158', 'source_id': 'vbk-20261104-0435-layer-5'}]
Windpark Elbenrod [{'count': 8, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V126 - 3,45 MW', 'source_id': 'mastr-wind-20261103-he'}]
Utteros [{'count': 3, 'manufacturer': 'Vestas', 'model': 'VE42', 'source_id': 'vbk-20261103-2135-layer-9'}]
Lärbro Liffride [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W-2700', 'source_id': 'vbk-20261103-1835-layer-12'}]
Västra Derome [{'count': 6, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2135-layer-5'}]
Korpfjället [{'count': 9, 'manufacturer': 'Siemens', 'model': 'SWT 2,3-101', 'source_id': 'vbk-20261104-0135-layer-5'}]
Windpark Burkersdorf [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V162-7.2', 'source_id': 'mastr-wind-20261103-sn'}]
Windpark Schlage 3 [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N133 STE', 'source_id': 'mastr-wind-20261103-mv'}]
Anneberg [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V136', 'source_id': 'vbk-20261103-2235-layer-5'}]
Jokkmokksliden [{'count': 10, 'manufacturer': 'Nordex', 'model': 'N100/2500', 'source_id': 'vbk-20261104-0535-layer-5'}]
Windpark Buch [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V112-3.0 MW', 'source_id': 'mastr-wind-20261103-rp'}]
Birger Jarl [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE47', 'source_id': 'vbk-20261103-1135-layer-5'}]
Aldermyrberget [{'count': 17, 'manufacturer': 'Vestas', 'model': 'V150', 'source_id': 'vbk-20261104-0535-layer-5'}]
Windpark Bühlertann [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 126-3.3', 'source_id': 'mastr-wind-20261103-bw'}]
Ingrid Ylva Bjälbo [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Högberget [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-1.8', 'source_id': 'vbk-20261104-0135-layer-5'}]
Windpark Vogelsberg [{'count': 3, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'M1500-600/150', 'source_id': 'mastr-wind-20261103-he'}, {'count': 1, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'M150-600/150', 'source_id': 'mastr-wind-20261103-he'}]
Skeby II [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Genevad [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC406', 'source_id': 'vbk-20261103-2135-layer-5'}]
Tunhem 1 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Vindpark Nyvallsåsen [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261104-0235-layer-5'}]
Källeberg 6 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC406', 'source_id': 'vbk-20261103-2235-layer-5'}]
Dal [{'count': 4, 'manufacturer': 'Gamesa', 'model': 'G90-2.0', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Holzheim [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E175', 'source_id': 'mastr-wind-20261103-by'}]
Windpark Schadehorn [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-138 EP3 E2', 'source_id': 'mastr-wind-20261103-sh'}]
Windpark Salzgitter AG Abschnitt 1 [{'count': 4, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V136 4.2MW', 'source_id': 'mastr-wind-20261103-ni'}]
Skallberget/Utterberget [{'count': 12, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 170', 'source_id': 'vbk-20261104-0135-layer-5'}]
VIGLUNDA / 7307 [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Gråsjön Anja [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V66-1', 'source_id': 'vbk-20261104-0435-layer-5'}]
CEE Windpark Nonnweiler GmbH & Co. KG [{'count': 6, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 2.75-120', 'source_id': 'mastr-wind-20261103-sl'}]
Windpark Blockland [{'count': 1, 'manufacturer': 'REpower Systems SE', 'model': 'REpower MM82 Evolution', 'source_id': 'mastr-wind-20261103-hb'}, {'count': 1, 'manufacturer': 'REpower Systems SE', 'model': 'REpower MM82-Evolution', 'source_id': 'mastr-wind-20261103-hb'}, {'count': 2, 'manufacturer': 'REpower Systems SE', 'model': 'REpower MM92-Evolution', 'source_id': 'mastr-wind-20261103-hb'}]
Fjälkinge [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Obbach [{'count': 1, 'manufacturer': 'GE Renewable Germany GmbH', 'model': 'GE2.5-120', 'source_id': 'mastr-wind-20261103-by'}, {'count': 4, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE2.5-120', 'source_id': 'mastr-wind-20261103-by'}]
Örken-Munkabol [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V136', 'source_id': 'vbk-20261103-2135-layer-5'}]
Topperyd 3 och 4 [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90 2,0 MW', 'source_id': 'vbk-20261103-1535-layer-5'}]
Kommerberget [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261104-0435-layer-5'}]
Kvilla 2 [{'count': 2, 'manufacturer': 'Sinovel', 'model': 'SL3000', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark Waddewarden [{'count': 2, 'manufacturer': 'ENERCON GmbH', 'model': 'E-82', 'source_id': 'mastr-wind-20261103-ni'}, {'count': 2, 'manufacturer': 'ENERCON GmbH', 'model': 'E-101', 'source_id': 'mastr-wind-20261103-ni'}]
Lyby [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2035-layer-5'}]
Karlebytorp vind 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Underbacken [{'count': 3, 'manufacturer': 'Wind world a/s', 'model': 'W3700', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Tauberbischofsheim GmbH & Co. KG [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V-126', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Bergheim-Hüchelhoven [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163/6.X_TCS 164', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163/6.X_TCS 164', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Stuthof [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-40/5.40', 'source_id': 'mastr-wind-20261103-mv'}]
Windpark Werpeloh [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-ni'}]
Gategården, Bengt C [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-1', 'source_id': 'vbk-20261103-2235-layer-5'}]
Lindärva [{'count': 2, 'manufacturer': 'Gamesa', 'model': 'G58', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Könau Offenland [{'count': 6, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E1', 'source_id': 'mastr-wind-20261103-ni'}]
Össjö Skog [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E-92-2,3 MW', 'source_id': 'vbk-20261103-2035-layer-5'}, {'count': 1, 'manufacturer': 'Enercon', 'model': 'E-103', 'source_id': 'vbk-20261103-2035-layer-5'}]
HORSHAGA / 7309 [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Bühren-Spols GmbH & Co. KG [{'count': 5, 'manufacturer': 'Nordex Germany GmbH', 'model': 'Nordex N163/6.X TS 118', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Esperke [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N149/5.X', 'source_id': 'mastr-wind-20261103-ni'}]
Fole Stora Ryftes - Ryftes [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W2800', 'source_id': 'vbk-20261103-1835-layer-5'}]
Laxåskogen [{'count': 7, 'manufacturer': 'Siemens Gamesa', 'model': '3.6-130', 'source_id': 'vbk-20261104-0035-layer-5'}]
Windpark Altheim III [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-160 EP5 E3', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Marienmünster-Altenbergen [{'count': 3, 'manufacturer': 'Nordex SE', 'model': 'Nordex N175/6.x „Delta4000“', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Oberkochen [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N117', 'source_id': 'mastr-wind-20261103-bw'}]
Götala 1 [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-1135-layer-5'}]
Blisterliden [{'count': 14, 'manufacturer': 'Nordex', 'model': 'N163/6.X', 'source_id': 'vbk-20261104-0535-layer-5'}]
Windpark Auernheim [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E175', 'source_id': 'mastr-wind-20261103-by'}]
Windpark_Engelschoff [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'Enercon E-92/2,35 MW', 'source_id': 'mastr-wind-20261103-ni'}]
Björnskallen, Kajsa [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261104-0435-layer-5'}]
Vindparken Lönhult [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V162-6.2', 'source_id': 'vbk-20261103-1535-layer-5'}]
Brunsmo Vindkraftpark [{'count': 5, 'manufacturer': 'GE Wind Energy', 'model': '2,5XL', 'source_id': 'vbk-20261103-1935-layer-5'}]
Hejnum Boters (Fole Stora Sojdeby) [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-1835-layer-5'}]
Skedevi Bonnorp Vind AB [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90-1', 'source_id': 'vbk-20261103-1135-layer-5'}]
Winpark Schirl Frankenbach [{'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E-138', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 2, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175', 'source_id': 'mastr-wind-20261103-nw'}]
Stora Jordberga [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-2035-layer-5'}]
Vannborga [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1735-layer-5'}]
Dagsjön [{'count': 1, 'manufacturer': 'EWT', 'model': 'DW54/900kw', 'source_id': 'vbk-20261103-layer-5'}]
Stora Solberga [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
WKN Windkraft Nord GmbH &. Co. Windpark Roter Berg KG [{'count': 3, 'manufacturer': 'NEG Micon Deutschland GmbH', 'model': 'NM82c', 'source_id': 'mastr-wind-20261103-he'}, {'count': 1, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V82', 'source_id': 'mastr-wind-20261103-he'}]
Zavanna [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E40', 'source_id': 'vbk-20261103-2035-layer-5'}]
Kullen [{'count': 2, 'manufacturer': 'WindWorld', 'model': 'W3700/500', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Hasel [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 126-3.3', 'source_id': 'mastr-wind-20261103-bw'}]
Askers Via [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261104-0035-layer-5'}]
Windpark Staffelstein [{'count': 8, 'manufacturer': 'Nordex Energy GmbH', 'model': 'S70', 'source_id': 'mastr-wind-20261103-rp'}]
Windpark Mautitz Süd GmbH & Co. KG [{'count': 7, 'manufacturer': 'Siemens Wind Power GmbH & Co. KG', 'model': 'SWT-3.6-130', 'source_id': 'mastr-wind-20261103-sn'}]
MIT 9003 [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'MI5', 'source_id': 'vbk-20261103-2135-layer-9'}]
Windpark Gütersloh [{'count': 3, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 2.5-120', 'source_id': 'mastr-wind-20261103-nw'}]
Karlsfält [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E48', 'source_id': 'vbk-20261103-2235-layer-5'}, {'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Galtryggen [{'count': 4, 'manufacturer': 'Fuhrländer', 'model': 'FL2500', 'source_id': 'vbk-20261103-2335-layer-12'}, {'count': 2, 'manufacturer': 'Fuhrländer', 'model': 'FL2500', 'source_id': 'vbk-20261103-2335-layer-7'}]
Windpark Rüthen [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N175/6.X', 'source_id': 'mastr-wind-20261103-nw'}]
Ösarp/Knöbbens vindkraftverk [{'count': 1, 'manufacturer': 'NEG Micon', 'model': 'MI748', 'source_id': 'vbk-20261103-2135-layer-5'}]
Windpark Reken [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163/6.X TCS 164', 'source_id': 'mastr-wind-20261103-nw'}]
Grebban 3, Tanumshede [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Tommared [{'count': 6, 'manufacturer': 'Enercon', 'model': 'E92-2.3', 'source_id': 'vbk-20261103-2135-layer-5'}]
Hellvi Smöjen [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-1835-layer-5'}]
Bränninge [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC48', 'source_id': 'vbk-20261103-1135-layer-5'}]
Västermark [{'count': 3, 'manufacturer': 'Enercon', 'model': 'E82/2000', 'source_id': 'vbk-20261103-2235-layer-5'}]
Margot [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2035-layer-5'}]
Bolerum [{'count': 3, 'manufacturer': 'Nordex', 'model': 'N90/2500 LS-2 500', 'source_id': 'vbk-20261103-1535-layer-12'}]
Windpark Weede [{'count': 1, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 126-3.6 MW', 'source_id': 'mastr-wind-20261103-sh'}, {'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V 162-6.0 MW', 'source_id': 'mastr-wind-20261103-sh'}]
Möllebacken [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Pobzig [{'count': 5, 'manufacturer': 'Enron Wind GmbH', 'model': 'Enron Wind 1.5 s', 'source_id': 'mastr-wind-20261103-st'}]
Windpark Ovelgönne-Culturweg [{'count': 9, 'manufacturer': 'ENERCON GmbH', 'model': 'ENERCON E-160 EP5 E3', 'source_id': 'mastr-wind-20261103-ni'}]
Windpark Mettenheim [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'Enercon E175 EP5', 'source_id': 'mastr-wind-20261103-rp'}]
Tägneby [{'count': 1, 'manufacturer': 'WindWorld', 'model': 'W2700', 'source_id': 'vbk-20261103-1135-layer-9'}]
Windpark Maßbach [{'count': 5, 'manufacturer': 'Nordex Energy GmbH', 'model': 'Nordex N117', 'source_id': 'mastr-wind-20261103-by'}]
Elmer 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE29', 'source_id': 'vbk-20261104-0035-layer-9'}]
Vindpark Brännåsen [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261104-0235-layer-5'}]
Grimskullen [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Nylandsbergen, Getåsen, Rödsjöåsen. [{'count': 18, 'manufacturer': 'Vestas', 'model': 'V136', 'source_id': 'vbk-20261104-0335-layer-5'}]
Vindrosen Skårby [{'count': 1, 'manufacturer': 'GE Wind Energy', 'model': 'GE 2,85-103', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Everswinkel [{'count': 4, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N149-5.7 MW', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163-5.7 MW', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Warburg []
Uljeberg [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Ohne [{'count': 7, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'EW 1.5sl', 'source_id': 'mastr-wind-20261103-ni'}]
NATTORP 7303 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Högaliden [{'count': 25, 'manufacturer': 'Vestas', 'model': 'V150', 'source_id': 'vbk-20261104-0535-layer-5'}]
Windpark Firrel [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-66 / 18.70', 'source_id': 'mastr-wind-20261103-ni'}]
Vettåsen/Finnberget [{'count': 8, 'manufacturer': 'Enercon', 'model': 'E82-2.3', 'source_id': 'vbk-20261104-0235-layer-5'}]
Kollbogården III [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Werl Nord [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-nw'}]
Torkelsröd i Uddevalla [{'count': 1, 'manufacturer': 'WindEn', 'model': 'WindEn45', 'source_id': 'vbk-20261103-2235-layer-9'}]
Windpark Fonds Kötzlin-Barenthin GmbH & Co. KG [{'count': 17, 'manufacturer': 'ENERCON GmbH', 'model': 'E66/18.70', 'source_id': 'mastr-wind-20261103-bb'}]
Hönö Pinan [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V47', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Langwieden (Engen) [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'Enercon E175 EP5 E1', 'source_id': 'mastr-wind-20261103-bw'}]
Windpark Seewald II []
Virke [{'count': 2, 'manufacturer': 'Enercon', 'model': 'E44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Viking Vind [{'count': 1, 'manufacturer': 'Bonus', 'model': '600/44', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Calenberg-Wormeln [{'count': 12, 'manufacturer': 'Nordex SE', 'model': 'N175/6.X', 'source_id': 'mastr-wind-20261103-nw'}]
Hornamossen [{'count': 10, 'manufacturer': 'Siemens Gamesa', 'model': 'SWT-DD-130', 'source_id': 'vbk-20261103-1535-layer-5'}]
Skog 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2235-layer-5'}]
Trianel Windpark Grünberg [{'count': 3, 'manufacturer': 'GE Wind Energy GmbH', 'model': 'GE 2.75-120', 'source_id': 'mastr-wind-20261103-he'}]
Windpark Bokel [{'count': 3, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N149/4.0-4.5', 'source_id': 'mastr-wind-20261103-sh'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N133/4.8', 'source_id': 'mastr-wind-20261103-sh'}]
Ryda 2 [{'count': 1, 'manufacturer': 'WinWind', 'model': 'WWD-1-64', 'source_id': 'vbk-20261103-2235-layer-5'}]
SKALLMEJA / 7304 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-2235-layer-5'}]
Tagelberg 2 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Haarbrück-West [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP5 E2', 'source_id': 'mastr-wind-20261103-nw'}]
Windpark Damme [{'count': 12, 'manufacturer': 'Siemens Wind Power GmbH & Co. KG', 'model': 'SWT-3.6.-130', 'source_id': 'mastr-wind-20261103-ni'}]
Börstad 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Herrberga [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-1135-layer-5'}]
Sönnertorp [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V39', 'source_id': 'vbk-20261103-2035-layer-5'}]
Vindpark Stocka [{'count': 4, 'manufacturer': 'Vestas', 'model': 'V47-660', 'source_id': 'vbk-20261104-0235-layer-5'}]
Windpark Ristedt [{'count': 4, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N27', 'source_id': 'mastr-wind-20261103-ni'}]
Sjöbergs Säteri [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE27', 'source_id': 'vbk-20261103-2235-layer-9'}]
Lyrestad [{'count': 14, 'manufacturer': 'Vestas', 'model': 'V126', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Hottelstedt [{'count': 4, 'manufacturer': 'Sonstige', 'model': 'AN Bonus 1,3 MW/62', 'source_id': 'mastr-wind-20261103-th'}]
Isberget I [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-1135-layer-5'}]
Windpark Warendorf Milte [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP 5', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E-160 EP5', 'source_id': 'mastr-wind-20261103-nw'}]
Rytterås [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Windpark Beinerstadt [{'count': 3, 'manufacturer': 'Nordex SE', 'model': 'N163-6.X', 'source_id': 'mastr-wind-20261103-th'}]
Grebban 2 [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE44', 'source_id': 'vbk-20261103-2235-layer-5'}]
Skarstad [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E82', 'source_id': 'vbk-20261103-2235-layer-5'}]
Harriemöllan [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V47', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Spillhöhe [{'count': 5, 'manufacturer': 'Fuhrländer AG', 'model': 'FL 1000', 'source_id': 'mastr-wind-20261103-st'}]
Windpark Ballenberg [{'count': 5, 'manufacturer': 'ENERCON GmbH', 'model': 'E-175 EP-5', 'source_id': 'mastr-wind-20261103-bw'}]
MUNSTORP 7012 [{'count': 1, 'manufacturer': 'Enercon', 'model': 'EC53', 'source_id': 'vbk-20261103-2235-layer-5'}]
Röbergsfjället [{'count': 8, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261104-0135-layer-5'}]
Lemnhult [{'count': 32, 'manufacturer': 'Vestas', 'model': 'V112-3.0', 'source_id': 'vbk-20261103-1535-layer-5'}]
Norra Länsmansberget [{'count': 3, 'manufacturer': 'Siemens Gamesa', 'model': 'SG 6.2-170', 'source_id': 'vbk-20261103-2335-layer-5'}]
Appunamöllan [{'count': 1, 'manufacturer': 'Vestas', 'model': 'VE27', 'source_id': 'vbk-20261103-1135-layer-12'}]
Windpark Nettlingen [{'count': 2, 'manufacturer': 'ENERCON GmbH', 'model': 'E-66/18.70', 'source_id': 'mastr-wind-20261103-ni'}, {'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E-40/6.44 E1', 'source_id': 'mastr-wind-20261103-ni'}]
Säliträdberget [{'count': 8, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261104-0135-layer-5'}]
Ytterberg [{'count': 22, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261104-0535-layer-5'}]
Getaryggen, Söderryd, Stora Björstorp [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V100', 'source_id': 'vbk-20261103-2235-layer-5'}]
Blekhem [{'count': 6, 'manufacturer': 'Vestas', 'model': 'V100', 'source_id': 'vbk-20261103-1735-layer-5'}, {'count': 1, 'manufacturer': 'Vestas', 'model': 'V100', 'source_id': 'vbk-20261103-1735-layer-12'}]
Erikshester [{'count': 2, 'manufacturer': 'GE Wind Energy', 'model': 'GE 1.6 - 100 96HH', 'source_id': 'vbk-20261103-1535-layer-5'}]
Windpark Stahlem [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'Nordex N175/6.X', 'source_id': 'mastr-wind-20261103-rp'}]
Öringe [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2.0', 'source_id': 'vbk-20261103-2135-layer-5'}]
Markbygden ETT [{'count': 179, 'manufacturer': 'GE Wind Energy', 'model': 'GE 3.6-137', 'source_id': 'vbk-20261104-0635-layer-5'}]
Bürgerwindpark Ehndorf GmbH & Co. KG [{'count': 6, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N163/6.X STE', 'source_id': 'mastr-wind-20261103-sh'}]
Köpingebro [{'count': 1, 'manufacturer': 'Enercon', 'model': 'E53', 'source_id': 'vbk-20261103-2035-layer-9'}]
Windpark Leuthen []
Fjelie-Laxmans Åkarp [{'count': 5, 'manufacturer': 'Vestas', 'model': 'V80', 'source_id': 'vbk-20261103-2035-layer-5'}]
Spargott [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V52', 'source_id': 'vbk-20261103-2035-layer-5'}]
Windpark Schimmendorf GmbH & Co. KG [{'count': 7, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N117/2400', 'source_id': 'mastr-wind-20261103-by'}]
Windpark Homberg GmbH & Co. KG [{'count': 3, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'V126 - 3.45', 'source_id': 'mastr-wind-20261103-he'}]
Neanberg/VIK [{'count': 3, 'manufacturer': 'Vestas', 'model': 'V90-2', 'source_id': 'vbk-20261103-2235-layer-5'}]
Al-Ghat [{'count': 80, 'equipment_record_id': None, 'locator': 'PDFpage4 design table; page3 introduction for Al Ghat / page4 introduction for Waad', 'manufacturer': 'Windey Energy Technology Group Co., LTD', 'model': 'WD200-7700', 'rated_power_mw': 7.7, 'scope': 'Complete ESIA design fleet; not installed inventory', 'source_id': 'axia-alghat-nts-doc03'}]
Windpark Oberthal [{'count': 2, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V112-3.0', 'source_id': 'mastr-wind-20261103-sl'}, {'count': 2, 'manufacturer': 'Vestas Deutschland GmbH', 'model': 'Vestas V 112', 'source_id': 'mastr-wind-20261103-sl'}]
Stormon [{'count': 5, 'manufacturer': 'Siemens', 'model': 'SWT-3.2', 'source_id': 'vbk-20261104-0335-layer-5'}]
Windpark Mönkeberg [{'count': 2, 'manufacturer': 'ENERCON GmbH', 'model': 'E-115', 'source_id': 'mastr-wind-20261103-nw'}, {'count': 1, 'manufacturer': 'ENERCON GmbH', 'model': 'E-82', 'source_id': 'mastr-wind-20261103-nw'}]
Gårebo [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90-1,8 MW & 2,0 MW', 'source_id': 'vbk-20261103-1535-layer-12'}]
Windpark Westerbüttel [{'count': 3, 'manufacturer': 'ENERCON GmbH', 'model': 'E115', 'source_id': 'mastr-wind-20261103-sh'}, {'count': 2, 'manufacturer': 'ENERCON GmbH', 'model': 'E101', 'source_id': 'mastr-wind-20261103-sh'}]
Somaloma-Las Quemadas [{'count': 9, 'inventory_basis': 'Proposed fleet; exact OEM revision unknown', 'manufacturer': 'Nordex', 'model': 'N133', 'source_id': 'BOE-B-2026-27717', 'unit_rating_mw': 4.8}]
Windpark Saarwellingen [{'count': 3, 'manufacturer': 'Nordex Germany GmbH', 'model': 'N163 5.X', 'source_id': 'mastr-wind-20261103-sl'}]
Storliden [{'count': 8, 'manufacturer': 'Nordex', 'model': 'N100/2500', 'source_id': 'vbk-20261104-0535-layer-5'}]
Gettnabo 1 [{'count': 6, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1735-layer-5'}]
Windpark Bentwisch [{'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N52', 'source_id': 'mastr-wind-20261103-mv'}, {'count': 2, 'manufacturer': 'Nordex Energy GmbH', 'model': 'N54', 'source_id': 'mastr-wind-20261103-mv'}, {'count': 1, 'manufacturer': 'Nordex Energy GmbH', 'model': 'S77', 'source_id': 'mastr-wind-20261103-mv'}]
Jung [{'count': 1, 'manufacturer': 'Nordex', 'model': 'N43', 'source_id': 'vbk-20261103-2235-layer-5'}]
Århammar [{'count': 1, 'manufacturer': 'Vestas', 'model': 'RRB PS47', 'source_id': 'vbk-20261103-layer-5'}]
Windpark GmbH & Co. Hemeringen KG [{'count': 4, 'manufacturer': 'ENERCON GmbH', 'model': 'E-53', 'source_id': 'mastr-wind-20261103-ni'}]
Nottebäck [{'count': 1, 'manufacturer': 'Vestas', 'model': 'V90', 'source_id': 'vbk-20261103-1635-layer-5'}]
Högberget [{'count': 2, 'manufacturer': 'Vestas', 'model': 'V90-1.8', 'source_id': 'vbk-20261104-0135-layer-5'}]
Reported Canadian inventory composition is separate from OEM specifications and from a current operating census. Unknown manufacturers remain explicit.
inventory_counts = {}
for row in rows:
inventory = json.loads(row.get("extensions_json") or "{}").get("nrcan_inventory")
if inventory:
for group in inventory["fleet_groups"]:
manufacturer = group.get("Manufacturer") or "Unknown"
inventory_counts[manufacturer] = (
inventory_counts.get(manufacturer, 0) + group["inventory_count"]
)
if inventory_counts:
fig, ax = plt.subplots(figsize=(10, 5), layout="constrained")
pd.Series(inventory_counts).sort_values().plot.barh(ax=ax, color="#198c92")
ax.set(
xlabel="Reported inventory turbine rows in reconciled project groups",
ylabel="Reported manufacturer",
title="Canadian inventory composition · snapshot, not current operating fleet",
)

Swedish registry turbine states include proposals and historical equipment. “Uppfört” means physically erected, not independently verified operation.
swedish = [r for r in rows if r["entity_type"] == "turbines" and r.get("country_code") == "SWE"]
if swedish:
inventory = pd.DataFrame(
{
"Registry state": json.loads(r["extensions_json"])["source_fields"]["STATUS"],
"Reported manufacturer": r.get("manufacturer") or "Unknown",
}
for r in swedish
)
fig, axes = plt.subplots(1, 2, figsize=(14, 5), layout="constrained")
for ax, field in zip(axes, inventory.columns, strict=True):
inventory[field].value_counts().sort_values().plot.barh(ax=ax, color="#198c92")
ax.set(title=field, xlabel="Registry turbine records; all lifecycle states")
print("Swedish project coverage by reported county:")
print(projects.loc[projects.country_code.eq("SWE"), "region"].fillna("Unknown").value_counts())
print("Swedish linked project identities:", len({r["project_record_id"] for r in swedish}))
print("Inventory maximum ratings are not summed into installed project MW.")

Swedish project coverage by reported county:
region
Västra Götalands län 611
Skåne län 268
Östergötlands län 192
Kalmar län 134
Jönköpings län 108
Hallands län 100
Västerbottens län 71
Jämtlands län 68
Gävleborgs län 61
Örebro län 60
Kronobergs län 56
Västernorrland län 55
Värmlands län 54
Sveriges ekonomiska zon 53
Gotlands län 48
Dalarnas län 45
Norrbottens län 39
Blekinge län 33
Södermanlands län 32
Uppsala län 24
Stockholms län 21
Unknown 10
Västmanlands län 6
Name: count, dtype: int64
Swedish linked project identities: 2070
Inventory maximum ratings are not summed into installed project MW.
The two original numerical tables share density, pitch mode, turbulence, averaging period and manufacturer-calculated basis. Digitized curves are rejected.
curves = [r for r in rows if r["entity_type"] == "curves"]
assert compatible_curves(curves), "Curve conditions differ; separate comparisons required"
fig, ax = plt.subplots(figsize=(10, 5), layout="constrained")
for curve in curves:
points = pd.DataFrame(json.loads(curve["curve_points_json"]))
ax.plot(points.wind_speed_m_s, points.value, marker=".", label=curve["name"])
ax.set(
xlabel="Hub-height rotor-normal wind speed (m/s)",
ylabel="Calculated power (kW)",
title="Original V47 numerical tables · 1.225 kg/m³ · standard pitch · TI 10%",
)
ax.legend()
print("Curve conditions:", curves[0]["curve_conditions"])
plt.show()

Curve conditions: {"air_density_kg_m3":1.225,"frequency_hz":[50,60],"operating_mode":"standard pitch-regulated","performance_kind":"manufacturer_calculated","source_interval":"19-25 m/s: 660 kW; represented by endpoints, no interpolated samples","turbulence_intensity_pct":10,"wind_speed_averaging_minutes":10,"wind_speed_reference":"hub height, rotor-normal","wind_speed_unit":"m/s"}
German registry gross/net ratings and lifecycle observations stay at unit scope.
german = [r for r in rows if r["entity_type"] == "turbines" and r.get("country_code") == "DEU"]
if german:
states = pd.Series(
[json.loads(r["extensions_json"]).get("decoded_lifecycle") or "Unknown" for r in german]
)
fig, ax = plt.subplots(figsize=(10, 5), layout="constrained")
states.value_counts().sort_values().plot.barh(ax=ax, color="#198c92")
ax.set(
title="German registered units by reported lifecycle",
xlabel="Selected named-park inventory records; not a current operating census",
)
print("German linked parks:", len({r["project_record_id"] for r in german}))
print("Gross/net kW remain separate source fields; no farm MW is inferred.")

German linked parks: 385
Gross/net kW remain separate source fields; no farm MW is inferred.
Registry geography and integrated component ratings retain their own boundaries.
print("German project coverage by state; includes unresolved/historical scopes:")
print(projects.loc[projects.country_code.eq("DEU"), "region"].fillna("Unknown").value_counts())
print("Integrated gearbox-generator specifications; not turbine performance:")
print(
equipment.loc[
equipment.manufacturer.eq("Winergy"),
["model", "rated_power_kw", "rated_power_conditions", "mass_kg"],
]
)
German project coverage by state; includes unresolved/historical scopes:
region
Niedersachsen 73
Nordrhein-Westfalen 67
Hessen 38
Bayern 35
Baden-Württemberg 35
Rheinland-Pfalz 27
Unknown 26
Brandenburg 22
Schleswig-Holstein 22
Mecklenburg-Vorpommern 19
Sachsen 16
Saarland 12
Sachsen-Anhalt 9
Thüringen 8
Hamburg 1
Bremen 1
Name: count, dtype: int64
Integrated gearbox-generator specifications; not turbine performance:
model ... mass_kg
271 PZFG 2535 ... 31000.0
314 PZFG 2456 ... 25000.0
[2 rows x 4 columns]
Exact yaw/pitch gearboxes are component types, not installed turbine fleets.
ngc = equipment.loc[equipment.manufacturer.eq("NGC")]
if not ngc.empty:
print("NGC gearbox envelopes; rated torque and peak torque remain distinct:")
for _, component in ngc.iterrows():
spec = json.loads(component.extensions_json)
if "rated_torque_range_kNm" not in spec:
print(component.model, "Torque and speed-ratio specifications unknown")
continue
print(
component.model,
spec["function"],
spec["rated_torque_range_kNm"],
spec["peak_torque_kNm"],
"kNm",
spec["speed_ratio_range"],
)
NGC gearbox envelopes; rated torque and peak torque remain distinct:
SYW03 yaw drive [20, 30] 72 kNm [800, 3000]
SPT05A pitch gearbox [7, 12] 38 kNm [100, 250]
SYW07 yaw drive [38, 50] 138 kNm [1000, 3000]
SYW13 yaw drive [75, 100] 270 kNm [1000, 3000]
SMG282CDT175-0136 Torque and speed-ratio specifications unknown
SPT11A pitch gearbox [16, 20] 95 kNm [100, 300]
SPT01A pitch gearbox [3, 5] 18 kNm [100, 200]
CMG425AFF74-0212 Torque and speed-ratio specifications unknown
SYW09 yaw drive [45, 60] 165 kNm [1000, 3000]
SYW05 yaw drive [30, 40] 108 kNm [1000, 3000]
SMG282ADT113-0209 Torque and speed-ratio specifications unknown
SPT13A pitch gearbox [20, 30] 120 kNm [100, 350]
SPT09A pitch gearbox [14, 18] 66 kNm [100, 300]
SPT03A pitch gearbox [4, 8] 26 kNm [100, 200]
SMG322BDT177-0181 Torque and speed-ratio specifications unknown
SYW01 yaw drive [15, 20] 52 kNm [800, 3000]
SPT07A pitch gearbox [10, 14] 48 kNm [100, 250]
CMG262ADT159-0035 Torque and speed-ratio specifications unknown
SYW11 yaw drive [60, 85] 235 kNm [1000, 3000]
print("Bonfiglioli peak torque by application; reference values, not nominal ratings:")
for _, component in equipment.loc[equipment.manufacturer.eq("Bonfiglioli")].iterrows():
specs = json.loads(component.extensions_json)
if "peak_torque_Nm_by_application" in specs:
print(component.model, specs["peak_torque_Nm_by_application"], "Nm")
Bonfiglioli peak torque by application; reference values, not nominal ratings:
707 TW {'pitch': 28000} Nm
710 TW {'yaw': 70000} Nm
709 TW {'pitch': 60000, 'yaw': 60000} Nm
713 TW {'pitch': 140000, 'yaw': 150000} Nm
714 TW {'yaw': 180000} Nm
711 TW {'pitch': 80000, 'yaw': 90000} Nm
706 TW {'pitch': 16000} Nm
712 TW {'pitch': 110000, 'yaw': 120000} Nm
716 TW {'yaw': 225000} Nm
print("ABB historical converter ratings: typical generator kW; generator/grid kVA")
for _, component in equipment.loc[equipment.manufacturer.eq("ABB")].iterrows():
specs = json.loads(component.extensions_json or "{}")
if "typical_generator_rating_kw" in specs:
print(
component.model,
specs["typical_generator_rating_kw"],
specs["generator_apparent_power_kva"],
specs["grid_apparent_power_kva"],
)
ABB historical converter ratings: typical generator kW; generator/grid kVA
ACS880-77LC-2503A/2328A-7 2300 2991 2782
ACS880-87LC-4000A/3800A-7 3800 4780 4541
ACS880-87LC-8000A/7600A-7 7600 9561 9083
ACS880-87LC-5006A/4656A-7 4600 5982 5564
ACS880-87LC-4000A/4134A-7 4000 4780 4941
ACS880-77LC-3372A/3136A-7 3000 4029 3748
ACS880-87LC-8000A/8268A-7 8000 9561 9881
ACS880-77LC-1686A/1568A-7 1500 2014 1874
ACS880-77LC-5006A/4656A-7 4600 5982 5564
ACS880-77LC-1720A/1600A-7 1600 2056 1912
ACS880-87LC-6604A/6144A-7 6000 7893 7343
ACS880-87LC-3302A/3072A-7 3000 3947 3671
ACS880-87LC-1686A/1568A-7 1500 2014 1874
ACS880-77LC-860A/800A-7 800 1028 956
ACS880-87LC-2503A/2328A-7 2300 2991 2782
print("ABB coolant inlet limits; standard and optional limits remain separate:")
for _, component in equipment.loc[equipment.manufacturer.eq("ABB")].iterrows():
conditions = json.loads(component.extensions_json or "{}").get("series_technical_conditions")
if conditions:
print(
component.model,
conditions["coolant_inlet_temperature_c"],
conditions["optional_limits"],
)
ABB coolant inlet limits; standard and optional limits remain separate:
ACS880-77LC-2503A/2328A-7 [5, 50] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-87LC-4000A/3800A-7 [5, 45] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-87LC-8000A/7600A-7 [5, 45] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-87LC-5006A/4656A-7 [5, 45] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-87LC-4000A/4134A-7 [5, 45] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-77LC-3372A/3136A-7 [5, 50] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-87LC-8000A/8268A-7 [5, 45] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-77LC-1686A/1568A-7 [5, 50] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-77LC-5006A/4656A-7 [5, 50] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-77LC-1720A/1600A-7 [5, 50] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-87LC-6604A/6144A-7 [5, 45] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-87LC-3302A/3072A-7 [5, 45] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-87LC-1686A/1568A-7 [5, 45] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-77LC-860A/800A-7 [5, 50] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
ACS880-87LC-2503A/2328A-7 [5, 45] {'high_altitude_m': 4000, 'high_coolant_inlet_c': 55}
print("ACU motor-side current; 60s and 1s overload limits, not turbine output:")
for _, component in equipment.loc[
equipment.model.fillna("").str.startswith(("ACU 201-", "ACU 401-"))
].iterrows():
specs = json.loads(component.extensions_json)
print(component.model, specs["output_current_table_a"], specs["overload_current_a"])
ACU motor-side current; 60s and 1s overload limits, not turbine output:
ACU 201-21 32 {'1s': 64, '60s': 44.5}
ACU 401-13 5.8 {'1s': 11.6, '60s': 8.7}
ACU 401-47 210 {'1s': 375, '60s': 315}
ACU 201-09 5.4 {'1s': 8, '60s': 7.3}
ACU 401-22 22 {'1s': 33, '60s': 30.3}
ACU 401-12 4.2 {'1s': 8.4, '60s': 6.3}
ACU 201-18 18 {'1s': 33, '60s': 26.3}
ACU 201-13 9.5 {'1s': 19, '60s': 14.3}
ACU 401-23 25 {'1s': 50, '60s': 37.5}
ACU 401-03 1.6 {'1s': 3.2, '60s': 3.2}
ACU 401-25 32 {'1s': 64, '60s': 44.5}
ACU 401-15 7.8 {'1s': 15.6, '60s': 11.7}
ACU 401-37 110 {'1s': 220, '60s': 165}
ACU 401-43 150 {'1s': 270, '60s': 225}
ACU 401-27 40 {'1s': 80, '60s': 60}
ACU 401-35 90 {'1s': 180, '60s': 135}
ACU 401-05 1.8 {'1s': 3.6, '60s': 2.7}
ACU 201-22 35 {'1s': 64, '60s': 51.5}
ACU 401-29 45 {'1s': 90, '60s': 67.5}
ACU 201-05 3 {'1s': 6, '60s': 4.5}
ACU 201-11 7 {'1s': 14, '60s': 10.5}
ACU 201-19 22 {'1s': 33, '60s': 30.3}
ACU 201-07 4 {'1s': 8, '60s': 6}
ACU 401-18 9 {'1s': 18, '60s': 13.5}
ACU 401-45 180 {'1s': 325, '60s': 270}
ACU 201-15 12.5 {'1s': 19, '60s': 16.2}
ACU 401-19 14 {'1s': 28, '60s': 21}
ACU 401-31 60 {'1s': 120, '60s': 90}
ACU 401-09 3.2 {'1s': 6.4, '60s': 4.8}
ACU 201-01 1.6 {'1s': 3.2, '60s': 3.2}
ACU 401-01 1 {'1s': 2, '60s': 2}
ACU 401-11 3.8 {'1s': 7.6, '60s': 5.7}
ACU 401-07 2.4 {'1s': 4.8, '60s': 3.6}
ACU 201-03 2.5 {'1s': 5, '60s': 5}
ACU 401-49 250 {'1s': 375, '60s': 332}
ACU 401-39 125 {'1s': 250, '60s': 187.5}
ACU 401-21 18 {'1s': 33, '60s': 26.3}
ACU 401-33 75 {'1s': 150, '60s': 112.5}
print("ACU input-phase limits and switching-frequency observations:")
for _, component in equipment.loc[equipment.model.fillna("").str.startswith("ACU 201-")].iterrows():
specs = json.loads(component.extensions_json)
print(component.model, specs["switching_frequency_current_a"])
if "single_two_phase_max_output_current_a" in specs:
print("Single/two-phase maximum A:", specs["single_two_phase_max_output_current_a"])
ACU input-phase limits and switching-frequency observations:
ACU 201-21 {'12kHz': 26.9, '16kHz': 21.8, '2kHz': 32, '4kHz': 32, '8kHz': 32}
ACU 201-09 {'12kHz': 4.5, '16kHz': 3.7, '2kHz': 5.4, '4kHz': 5.4, '8kHz': 5.4}
ACU 201-18 {'12kHz': 15.1, '16kHz': 12.2, '2kHz': 18, '4kHz': 18, '8kHz': 18}
ACU 201-13 {'12kHz': 8, '16kHz': 6.5, '2kHz': 9.5, '4kHz': 9.5, '8kHz': 9.5}
ACU 201-22 {'12kHz': 29.4, '16kHz': 23.8, '2kHz': 40, '4kHz': 38.3, '8kHz': 35}
ACU 201-05 {'12kHz': 2.5, '16kHz': 2, '2kHz': 3, '4kHz': 3, '8kHz': 3}
ACU 201-11 {'12kHz': 5.9, '16kHz': 4.8, '2kHz': 7, '4kHz': 7, '8kHz': 7}
ACU 201-19 {'12kHz': 18.5, '16kHz': 15, '2kHz': 23, '4kHz': 22.7, '8kHz': 22}
ACU 201-07 {'12kHz': 3.4, '16kHz': 2.7, '2kHz': 4, '4kHz': 4, '8kHz': 4}
ACU 201-15 {'12kHz': 10.5, '16kHz': 8.5, '2kHz': 12.5, '4kHz': 12.5, '8kHz': 12.5}
Single/two-phase maximum A: 9.5
ACU 201-01 {'12kHz': 1.3, '16kHz': 1.1, '2kHz': 1.6, '4kHz': 1.6, '8kHz': 1.6}
ACU 201-03 {'12kHz': 2.1, '16kHz': 1.7, '2kHz': 2.5, '4kHz': 2.5, '8kHz': 2.5}
print("ACUx10 frame-specific catalogue ratings; no turbine performance inference:")
for _, component in equipment.loc[
equipment.model.fillna("").str.startswith(("ACU 210-", "ACU 410-", "ACU 510-", "ACU 610-"))
].iterrows():
specs = json.loads(component.extensions_json)
print(
component.model,
"frame",
specs["size"],
"mains V",
specs["rated_mains_voltage_v"],
"motor A",
specs["output_current_table_a"],
"overload A",
specs["overload_current_a"],
"cooling options",
specs["mechanical_options"],
)
ACUx10 frame-specific catalogue ratings; no turbine performance inference:
ACU 410-29 frame 5 mains V 400 motor A 45 overload A {'1s': 90, '60s': 67.5} cooling options ['A', 'C', 'L']
ACU 410-53 frame 7 mains V 400 motor A 380 overload A {'1s': 680, '60s': 570} cooling options ['L']
ACU 610-61 frame 8 mains V 690 motor A 450 overload A {'1s': 810, '60s': 675} cooling options ['A', 'L', 'M', 'N']
ACU 410-15 frame 2 mains V 400 motor A 7.8 overload A {'1s': 15.6, '60s': 11.7} cooling options ['A', 'C']
ACU 410-19 frame 3 mains V 400 motor A 14 overload A {'1s': 28, '60s': 21} cooling options ['A', 'C']
ACU 410-33 frame 6 mains V 400 motor A 75 overload A {'1s': 150, '60s': 112.5} cooling options ['A', 'L']
ACU 210-01 frame 1 mains V 230 motor A 1.6 overload A {'1s': 3.2, '60s': 3.2} cooling options ['A', 'C']
ACU 410-03 frame 1 mains V 400 motor A 1.6 overload A {'1s': 3.2, '60s': 3.2} cooling options ['A', 'C']
ACU 410-31 frame 5 mains V 400 motor A 60 overload A {'1s': 120, '60s': 90} cooling options ['A', 'C', 'L']
ACU 210-13 frame 2 mains V 230 motor A 9.5 overload A {'1s': 19, '60s': 14.3} cooling options ['A', 'C']
ACU 510-53 frame 8 mains V 525 motor A 290 overload A {'1s': 520, '60s': 435} cooling options ['A', 'L', 'M', 'N']
ACU 610-55 frame 8 mains V 690 motor A 280 overload A {'1s': 510, '60s': 420} cooling options ['A', 'L', 'M', 'N']
ACU 210-21 frame 4 mains V 230 motor A 32 overload A {'1s': 64, '60s': 44.5} cooling options ['A', 'C']
ACU 410-09 frame 1 mains V 400 motor A 3.2 overload A {'1s': 6.4, '60s': 4.8} cooling options ['A', 'C']
ACU 210-09 frame 1 mains V 230 motor A 5.4 overload A {'1s': 8, '60s': 7.3} cooling options ['A', 'C']
ACU 410-49 frame 7 mains V 400 motor A 250 overload A {'1s': 375, '60s': 332} cooling options ['A', 'L']
ACU 410-23 frame 4 mains V 400 motor A 25 overload A {'1s': 50, '60s': 37.5} cooling options ['A', 'C']
ACU 210-22 frame 4 mains V 230 motor A 35 overload A {'1s': 64, '60s': 51.5} cooling options ['A', 'C']
ACU 410-51 frame 7 mains V 400 motor A 305 overload A {'1s': 550, '60s': 460} cooling options ['A', 'L']
ACU 610-57 frame 8 mains V 690 motor A 350 overload A {'1s': 630, '60s': 530} cooling options ['A', 'L', 'M', 'N']
ACU 410-18 frame 2 mains V 400 motor A 9 overload A {'1s': 18, '60s': 13.5} cooling options ['A', 'C']
ACU 410-55 frame 8 mains V 400 motor A 475 overload A {'1s': 855, '60s': 715} cooling options ['A', 'L', 'M', 'N']
ACU 210-07 frame 1 mains V 230 motor A 4 overload A {'1s': 8, '60s': 6} cooling options ['A', 'C']
ACU 410-11 frame 1 mains V 400 motor A 3.8 overload A {'1s': 7.6, '60s': 5.7} cooling options ['A', 'C']
ACU 410-45 frame 7 mains V 400 motor A 180 overload A {'1s': 325, '60s': 270} cooling options ['A', 'L']
ACU 410-43 frame 7 mains V 400 motor A 150 overload A {'1s': 270, '60s': 225} cooling options ['A', 'L']
ACU 210-19 frame 3 mains V 230 motor A 22 overload A {'1s': 33, '60s': 30.3} cooling options ['A', 'C']
ACU 410-39 frame 6 mains V 400 motor A 125 overload A {'1s': 250, '60s': 187.5} cooling options ['A', 'L']
ACU 210-05 frame 1 mains V 230 motor A 3 overload A {'1s': 6, '60s': 5.4} cooling options ['A', 'C']
ACU 410-61 frame 8 mains V 400 motor A 735 overload A {'1s': 1330, '60s': 1100} cooling options ['A', 'L', 'M', 'N']
ACU 410-12 frame 1 mains V 400 motor A 4.2 overload A {'1s': 8.4, '60s': 6.3} cooling options ['A', 'C']
ACU 410-27 frame 5 mains V 400 motor A 40 overload A {'1s': 80, '60s': 60} cooling options ['A', 'C', 'L']
ACU 410-51 frame 8 mains V 400 motor A 305 overload A {'1s': 550, '60s': 460} cooling options ['A', 'L', 'M', 'N']
ACU 210-18 frame 3 mains V 230 motor A 18 overload A {'1s': 33, '60s': 26.3} cooling options ['A', 'C']
ACU 510-61 frame 8 mains V 525 motor A 560 overload A {'1s': 1000, '60s': 840} cooling options ['A', 'L', 'M', 'N']
ACU 510-55 frame 8 mains V 525 motor A 360 overload A {'1s': 650, '60s': 540} cooling options ['A', 'L', 'M', 'N']
ACU 610-53 frame 8 mains V 690 motor A 230 overload A {'1s': 420, '60s': 350} cooling options ['A', 'L', 'M', 'N']
ACU 410-22 frame 3 mains V 400 motor A 22 overload A {'1s': 33, '60s': 30.3} cooling options ['A', 'C']
ACU 210-03 frame 1 mains V 230 motor A 2.5 overload A {'1s': 5, '60s': 5} cooling options ['A', 'C']
ACU 410-01 frame 1 mains V 400 motor A 1 overload A {'1s': 2, '60s': 2} cooling options ['A', 'C']
ACU 610-51 frame 8 mains V 690 motor A 180 overload A {'1s': 330, '60s': 270} cooling options ['A', 'L', 'M', 'N']
ACU 410-53 frame 8 mains V 400 motor A 380 overload A {'1s': 685, '60s': 570} cooling options ['A', 'L', 'M', 'N']
ACU 410-05 frame 1 mains V 400 motor A 1.8 overload A {'1s': 3.6, '60s': 2.7} cooling options ['A', 'C']
ACU 410-35 frame 6 mains V 400 motor A 90 overload A {'1s': 180, '60s': 135} cooling options ['A', 'L']
ACU 410-25 frame 4 mains V 400 motor A 32 overload A {'1s': 64, '60s': 44.5} cooling options ['A', 'C']
ACU 410-37 frame 6 mains V 400 motor A 110 overload A {'1s': 220, '60s': 165} cooling options ['A', 'L']
ACU 410-21 frame 3 mains V 400 motor A 18 overload A {'1s': 33, '60s': 26.3} cooling options ['A', 'C']
ACU 410-47 frame 7 mains V 400 motor A 210 overload A {'1s': 375, '60s': 315} cooling options ['A', 'L']
ACU 510-57 frame 8 mains V 525 motor A 450 overload A {'1s': 810, '60s': 675} cooling options ['A', 'L', 'M', 'N']
ACU 210-11 frame 1 mains V 230 motor A 7 overload A {'1s': 14, '60s': 10.5} cooling options ['A', 'C']
ACU 210-15 frame 2 mains V 230 motor A 12.5 overload A {'1s': 19, '60s': 16.2} cooling options ['A', 'C']
ACU 410-07 frame 1 mains V 400 motor A 2.4 overload A {'1s': 4.8, '60s': 3.6} cooling options ['A', 'C']
ACU 510-59 frame 8 mains V 525 motor A 490 overload A {'1s': 880, '60s': 735} cooling options ['A', 'L', 'M', 'N']
ACU 510-51 frame 8 mains V 525 motor A 230 overload A {'1s': 420, '60s': 345} cooling options ['A', 'L', 'M', 'N']
ACU 410-59 frame 8 mains V 400 motor A 645 overload A {'1s': 1160, '60s': 970} cooling options ['A', 'L', 'M', 'N']
ACU 610-59 frame 8 mains V 690 motor A 400 overload A {'1s': 720, '60s': 600} cooling options ['A', 'L', 'M', 'N']
ACU 410-57 frame 8 mains V 400 motor A 595 overload A {'1s': 1070, '60s': 895} cooling options ['A', 'L', 'M', 'N']
ACU 410-13 frame 2 mains V 400 motor A 5.8 overload A {'1s': 11.6, '60s': 8.7} cooling options ['A', 'C']
Exact line-choke pairings are component compatibility, not turbine performance.
for component in rows:
if component.get("equipment_category") == "line_choke":
specs = json.loads(component["extensions_json"])
print(
component["model"],
"nominal A",
specs["nominal_current_a"],
"inductance mH",
specs["inductance_mh"],
"dissipation W",
specs["power_dissipation_w"],
"documented inverter pairings",
len(json.loads(component["compatibility_json"])),
)
LCVT008 nominal A 8 inductance mH 3.66 dissipation W 30 documented inverter pairings 2
LCVS006 nominal A 6 inductance mH None dissipation W 8 documented inverter pairings 3
LCVT350AL-525 nominal A None inductance mH 0.084 dissipation W None documented inverter pairings 1
LCVS008 nominal A 8 inductance mH None dissipation W 8 documented inverter pairings 1
LCVT200AL-690 nominal A 200.0 inductance mH 0.27 dissipation W 420.0 documented inverter pairings 1
LCVT160 nominal A 160 inductance mH 0.18 dissipation W 180 documented inverter pairings 1
LCVT250 nominal A 250 inductance mH 0.12 dissipation W 210 documented inverter pairings 1
LCVT210 nominal A 210 inductance mH 0.14 dissipation W 200 documented inverter pairings 1
LCVT215AL-525 nominal A 215.0 inductance mH 0.13 dissipation W 370.0 documented inverter pairings 1
LCVT280AL-525 nominal A None inductance mH 0.105 dissipation W None documented inverter pairings 1
LCVT015 nominal A 15 inductance mH 1.95 dissipation W 45 documented inverter pairings 2
LCVT018 nominal A 18 inductance mH 1.63 dissipation W 70 documented inverter pairings 2
LCVT034 nominal A 34 inductance mH 0.86 dissipation W 85 documented inverter pairings 3
LCVT160AL-690 nominal A 160.0 inductance mH 0.33 dissipation W 350.0 documented inverter pairings 1
LCVT025 nominal A 25 inductance mH None dissipation W None documented inverter pairings 2
LCVT180 nominal A 180 inductance mH 0.16 dissipation W 185 documented inverter pairings 1
LCVT410AL-690 nominal A 410.0 inductance mH 0.13 dissipation W 660.0 documented inverter pairings 1
LCVT320AL-690 nominal A 320.0 inductance mH 0.18 dissipation W 570.0 documented inverter pairings 1
LCVT550AL-525 nominal A None inductance mH 0.052 dissipation W None documented inverter pairings 2
LCVT135 nominal A 135 inductance mH 0.22 dissipation W 180 documented inverter pairings 1
LCVT440AL-525 nominal A None inductance mH 0.068 dissipation W None documented inverter pairings 2
LCVT690AL-400 nominal A None inductance mH 0.046 dissipation W None documented inverter pairings 2
LCVS015 nominal A 15 inductance mH None dissipation W 12 documented inverter pairings 1
LCVT250AL-690 nominal A 250.0 inductance mH 0.21 dissipation W 480.0 documented inverter pairings 1
LCVT090 nominal A 90 inductance mH 0.33 dissipation W 120 documented inverter pairings 1
LCVT010 nominal A 10 inductance mH 2.93 dissipation W 30 documented inverter pairings 2
LCVS010 nominal A 10 inductance mH None dissipation W 10 documented inverter pairings 1
LCVT470AL-525 nominal A 470.0 inductance mH 0.06 dissipation W 610.0 documented inverter pairings 1
LCVT060 nominal A 60 inductance mH 0.49 dissipation W 100 documented inverter pairings 2
LCVT115 nominal A 115 inductance mH 0.25 dissipation W 140 documented inverter pairings 1
LCVT004 nominal A 4 inductance mH 7.32 dissipation W 20 documented inverter pairings 11
LCVT360AL-690 nominal A 360.0 inductance mH 0.15 dissipation W 630.0 documented inverter pairings 1
LCVS018 nominal A 18 inductance mH None dissipation W 15 documented inverter pairings 1
LCVT075 nominal A 75 inductance mH 0.37 dissipation W 110 documented inverter pairings 1
LCVT006 nominal A 6 inductance mH 4.88 dissipation W 25 documented inverter pairings 2
LCVT050 nominal A 50 inductance mH 0.59 dissipation W 100 documented inverter pairings 1
Application-specific choke ratings and qualified filter ratings stay separate.
for component in rows:
if component.get("equipment_category") not in {"line_choke", "emc_filter"}:
continue
specs = json.loads(component["extensions_json"])
if "application_observations" in specs:
print(component["model"], "application ratings", specs["application_observations"])
if component["equipment_category"] == "emc_filter":
print(
component["model"],
"rated A",
specs["rated_current_a"],
"leakage mA",
specs["leakage_current_ma"],
"catalogue dissipation W",
specs["power_dissipation_w"],
"conditions",
specs["technical_conditions"],
)
FTV400A-690 rated A 400 leakage mA 17 catalogue dissipation W 55 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
LCVT350AL-525 application ratings [{'inductance_mh': 0.084, 'inverter_model': 'ACU 410-53', 'locator': 'p55 explicit application row', 'nominal_current_a': 350.0, 'power_dissipation_w': 500.0, 'source_id': 'bonfiglioli-acu-r04-0'}, {'inductance_mh': 0.084, 'inverter_model': 'ACU 510-55', 'locator': 'p55 explicit application row', 'nominal_current_a': 335.0, 'power_dissipation_w': 460.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
LCVT200AL-690 application ratings [{'inductance_mh': 0.27, 'inverter_model': 'ACU 610-53', 'locator': 'p55 explicit application row', 'nominal_current_a': 200.0, 'power_dissipation_w': 420.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
HLD 110-500/130 rated A 130 leakage mA 22 catalogue dissipation W 90 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
LCVT215AL-525 application ratings [{'inductance_mh': 0.13, 'inverter_model': 'ACU 510-51', 'locator': 'p55 explicit application row', 'nominal_current_a': 215.0, 'power_dissipation_w': 370.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
LCVT280AL-525 application ratings [{'inductance_mh': 0.105, 'inverter_model': 'ACU 410-51', 'locator': 'p55 explicit application row', 'nominal_current_a': 280.0, 'power_dissipation_w': 460.0, 'source_id': 'bonfiglioli-acu-r04-0'}, {'inductance_mh': 0.105, 'inverter_model': 'ACU 510-53', 'locator': 'p55 explicit application row', 'nominal_current_a': 270.0, 'power_dissipation_w': 430.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
LCVT160AL-690 application ratings [{'inductance_mh': 0.33, 'inverter_model': 'ACU 610-51', 'locator': 'p55 explicit application row', 'nominal_current_a': 160.0, 'power_dissipation_w': 350.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
HLD 110-500/180 rated A 180 leakage mA 31 catalogue dissipation W 150 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
HLD 110-500/100 rated A 100 leakage mA 30 catalogue dissipation W 60 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
HLD 110-500/16 rated A 16 leakage mA 21 catalogue dissipation W 12 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
FTV018B rated A 18 leakage mA 1.5 catalogue dissipation W 20 conditions {'frequency_hz': [50, 60], 'locator': 'p58', 'maximum_ambient_temperature_c': 40, 'maximum_voltage_v': 480, 'operating_and_storage_temperature_c': [-25, 100], 'overload': '1.5 times rated current, one minute every 30 minutes', 'phases': 3, 'protection': 'IP00', 'source_id': 'bonfiglioli-acu-r04-0', 'voltage_tolerance_plus_pct': 10}
LCVT410AL-690 application ratings [{'inductance_mh': 0.13, 'inverter_model': 'ACU 610-61', 'locator': 'p55 explicit application row', 'nominal_current_a': 410.0, 'power_dissipation_w': 660.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
LCVT320AL-690 application ratings [{'inductance_mh': 0.18, 'inverter_model': 'ACU 610-57', 'locator': 'p55 explicit application row', 'nominal_current_a': 320.0, 'power_dissipation_w': 570.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
FTV401A rated A 400 leakage mA 42 catalogue dissipation W 55 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
HLD 110-500/8 rated A 8 leakage mA 20 catalogue dissipation W 6 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
LCVT550AL-525 application ratings [{'inductance_mh': 0.052, 'inverter_model': 'ACU 410-57', 'locator': 'p55 explicit application row', 'nominal_current_a': 550.0, 'power_dissipation_w': 680.0, 'source_id': 'bonfiglioli-acu-r04-0'}, {'inductance_mh': 0.052, 'inverter_model': 'ACU 510-61', 'locator': 'p55 explicit application row', 'nominal_current_a': 525.0, 'power_dissipation_w': 620.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
LCVT440AL-525 application ratings [{'inductance_mh': 0.068, 'inverter_model': 'ACU 410-55', 'locator': 'p55 explicit application row', 'nominal_current_a': 440.0, 'power_dissipation_w': 630.0, 'source_id': 'bonfiglioli-acu-r04-0'}, {'inductance_mh': 0.068, 'inverter_model': 'ACU 510-57', 'locator': 'p55 explicit application row', 'nominal_current_a': 420.0, 'power_dissipation_w': 575.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
HLD 110-500/42 rated A 42 leakage mA 30 catalogue dissipation W 22 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
LCVT690AL-400 application ratings [{'inductance_mh': 0.046, 'inverter_model': 'ACU 410-59', 'locator': 'p55 explicit application row', 'nominal_current_a': 620.0, 'power_dissipation_w': 640.0, 'source_id': 'bonfiglioli-acu-r04-0'}, {'inductance_mh': 0.046, 'inverter_model': 'ACU 410-61', 'locator': 'p55 explicit application row', 'nominal_current_a': 690.0, 'power_dissipation_w': 790.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
HLD 110-500/75 rated A 75 leakage mA 22 catalogue dissipation W 35 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
LCVT250AL-690 application ratings [{'inductance_mh': 0.21, 'inverter_model': 'ACU 610-55', 'locator': 'p55 explicit application row', 'nominal_current_a': 250.0, 'power_dissipation_w': 480.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
FTV630A rated A 630 leakage mA 42 catalogue dissipation W 65 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
LCVT470AL-525 application ratings [{'inductance_mh': 0.06, 'inverter_model': 'ACU 510-59', 'locator': 'p55 explicit application row', 'nominal_current_a': 470.0, 'power_dissipation_w': 610.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
FTV040B rated A 40 leakage mA 1.2 catalogue dissipation W 35 conditions {'frequency_hz': [50, 60], 'locator': 'p58', 'maximum_ambient_temperature_c': 40, 'maximum_voltage_v': 480, 'operating_and_storage_temperature_c': [-25, 100], 'overload': '1.5 times rated current, one minute every 30 minutes', 'phases': 3, 'protection': 'IP00', 'source_id': 'bonfiglioli-acu-r04-0', 'voltage_tolerance_plus_pct': 10}
HLD 110-500/250 rated A 250 leakage mA 37 catalogue dissipation W 180 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
LCVT360AL-690 application ratings [{'inductance_mh': 0.15, 'inverter_model': 'ACU 610-59', 'locator': 'p55 explicit application row', 'nominal_current_a': 360.0, 'power_dissipation_w': 630.0, 'source_id': 'bonfiglioli-acu-r04-0'}]
HLD 110-500/30 rated A 30 leakage mA 29 catalogue dissipation W 15 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
HLD 110-500/55 rated A 55 leakage mA 30 catalogue dissipation W 30 conditions {'frequency_hz': {'maximum': 60}, 'locator': 'p60 book-type section', 'operating_and_storage_temperature_c': [-25, 80], 'overload': '4 times rated current at switch-on; 1.5 times for one minute once per hour', 'protection': 'IP20', 'source_id': 'bonfiglioli-acu-r04-0'}
Braking duty is conditional on drive rating, not wind-turbine generation.
for component in rows:
if component.get("equipment_category") == "braking_resistor":
specs = json.loads(component["extensions_json"])
print(
component["model"],
specs["resistance_ohm"],
"ohm",
specs["continuous_rated_power_w"],
"W",
specs["application_observations"],
)
BR 4000/16 16.0 ohm 4000.0 W [{'combination_continuous_power_w': 4000.0, 'combination_resistance_ohm': 16.0, 'drive_rated_power_kw': 18.5, 'duty_cycle_pct_at_drive_rated_power': 22, 'inverter_model': 'ACU 410-27', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 4000.0, 'combination_resistance_ohm': 16.0, 'drive_rated_power_kw': 22.0, 'duty_cycle_pct_at_drive_rated_power': 18, 'inverter_model': 'ACU 410-29', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 4000.0, 'combination_resistance_ohm': 16.0, 'drive_rated_power_kw': 30.0, 'duty_cycle_pct_at_drive_rated_power': 13, 'inverter_model': 'ACU 410-31', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}]
BR 432/37 37.0 ohm 432.0 W [{'combination_continuous_power_w': 432.0, 'combination_resistance_ohm': 37.0, 'drive_rated_power_kw': 1.5, 'duty_cycle_pct_at_drive_rated_power': 29, 'inverter_model': 'ACU 210-11', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 432.0, 'combination_resistance_ohm': 37.0, 'drive_rated_power_kw': 2.2, 'duty_cycle_pct_at_drive_rated_power': 20, 'inverter_model': 'ACU 210-13', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 432.0, 'combination_resistance_ohm': 37.0, 'drive_rated_power_kw': 3.0, 'duty_cycle_pct_at_drive_rated_power': 14, 'inverter_model': 'ACU 210-15', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}]
BR 1333/12 12.0 ohm 1333.0 W [{'combination_continuous_power_w': 1333.0, 'combination_resistance_ohm': 12.0, 'drive_rated_power_kw': 7.5, 'duty_cycle_pct_at_drive_rated_power': 18, 'inverter_model': 'ACU 210-21', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 1333.0, 'combination_resistance_ohm': 12.0, 'drive_rated_power_kw': 9.2, 'duty_cycle_pct_at_drive_rated_power': 14, 'inverter_model': 'ACU 210-22', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}]
BR 2000/32 32.0 ohm 2000.0 W [{'combination_continuous_power_w': 2000.0, 'combination_resistance_ohm': 32.0, 'drive_rated_power_kw': 11.0, 'duty_cycle_pct_at_drive_rated_power': 18, 'inverter_model': 'ACU 410-23', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 2000.0, 'combination_resistance_ohm': 32.0, 'drive_rated_power_kw': 15.0, 'duty_cycle_pct_at_drive_rated_power': 13, 'inverter_model': 'ACU 410-25', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}]
BR 667/24 24.0 ohm 667.0 W [{'combination_continuous_power_w': 667.0, 'combination_resistance_ohm': 24.0, 'drive_rated_power_kw': 4.0, 'duty_cycle_pct_at_drive_rated_power': 17, 'inverter_model': 'ACU 210-18', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 667.0, 'combination_resistance_ohm': 24.0, 'drive_rated_power_kw': 5.5, 'duty_cycle_pct_at_drive_rated_power': 12, 'inverter_model': 'ACU 210-19', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}]
BR 8000/7 7.5 ohm 8000.0 W [{'combination_continuous_power_w': 8000.0, 'combination_resistance_ohm': 7.5, 'drive_rated_power_kw': 37.0, 'duty_cycle_pct_at_drive_rated_power': 22, 'inverter_model': 'ACU 410-33', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 8000.0, 'combination_resistance_ohm': 7.5, 'drive_rated_power_kw': 45.0, 'duty_cycle_pct_at_drive_rated_power': 18, 'inverter_model': 'ACU 410-35', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 8000.0, 'combination_resistance_ohm': 7.5, 'drive_rated_power_kw': 55.0, 'duty_cycle_pct_at_drive_rated_power': 15, 'inverter_model': 'ACU 410-37', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 8000.0, 'combination_resistance_ohm': 7.5, 'drive_rated_power_kw': 65.0, 'duty_cycle_pct_at_drive_rated_power': 12, 'inverter_model': 'ACU 410-39', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 8000.0, 'combination_resistance_ohm': 7.5, 'drive_rated_power_kw': 75.0, 'duty_cycle_pct_at_drive_rated_power': 11, 'inverter_model': 'ACU 410-43', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 8000.0, 'combination_resistance_ohm': 7.5, 'drive_rated_power_kw': 90.0, 'duty_cycle_pct_at_drive_rated_power': 9, 'inverter_model': 'ACU 410-45', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 16000.0, 'combination_resistance_ohm': 3.75, 'drive_rated_power_kw': 110.0, 'duty_cycle_pct_at_drive_rated_power': 15, 'inverter_model': 'ACU 410-47', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 2, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 16000.0, 'combination_resistance_ohm': 3.75, 'drive_rated_power_kw': 132.0, 'duty_cycle_pct_at_drive_rated_power': 12, 'inverter_model': 'ACU 410-49', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 2, 'source_id': 'bonfiglioli-acu-r04-0'}]
BR 160/100 100.0 ohm 160.0 W [{'combination_continuous_power_w': 160.0, 'combination_resistance_ohm': 100.0, 'drive_rated_power_kw': 0.25, 'duty_cycle_pct_at_drive_rated_power': 64, 'inverter_model': 'ACU 210-01', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 160.0, 'combination_resistance_ohm': 100.0, 'drive_rated_power_kw': 0.37, 'duty_cycle_pct_at_drive_rated_power': 43, 'inverter_model': 'ACU 210-03', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 160.0, 'combination_resistance_ohm': 100.0, 'drive_rated_power_kw': 0.55, 'duty_cycle_pct_at_drive_rated_power': 29, 'inverter_model': 'ACU 210-05', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 160.0, 'combination_resistance_ohm': 100.0, 'drive_rated_power_kw': 0.75, 'duty_cycle_pct_at_drive_rated_power': 21, 'inverter_model': 'ACU 210-07', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 160.0, 'combination_resistance_ohm': 100.0, 'drive_rated_power_kw': 1.1, 'duty_cycle_pct_at_drive_rated_power': 15, 'inverter_model': 'ACU 210-09', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}]
BR 1330/48 48.0 ohm 1330.0 W [{'combination_continuous_power_w': 1330.0, 'combination_resistance_ohm': 48.0, 'drive_rated_power_kw': 5.5, 'duty_cycle_pct_at_drive_rated_power': 24, 'inverter_model': 'ACU 410-19', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 1330.0, 'combination_resistance_ohm': 48.0, 'drive_rated_power_kw': 7.5, 'duty_cycle_pct_at_drive_rated_power': 18, 'inverter_model': 'ACU 410-21', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 1330.0, 'combination_resistance_ohm': 48.0, 'drive_rated_power_kw': 9.2, 'duty_cycle_pct_at_drive_rated_power': 14, 'inverter_model': 'ACU 410-22', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}]
BR 471/136 136.0 ohm 471.0 W [{'combination_continuous_power_w': 471.0, 'combination_resistance_ohm': 136.0, 'drive_rated_power_kw': 1.85, 'duty_cycle_pct_at_drive_rated_power': 25, 'inverter_model': 'ACU 410-12', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 471.0, 'combination_resistance_ohm': 136.0, 'drive_rated_power_kw': 2.2, 'duty_cycle_pct_at_drive_rated_power': 21, 'inverter_model': 'ACU 410-13', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 471.0, 'combination_resistance_ohm': 136.0, 'drive_rated_power_kw': 3.0, 'duty_cycle_pct_at_drive_rated_power': 16, 'inverter_model': 'ACU 410-15', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}]
BR 213/300 300.0 ohm 213.0 W [{'combination_continuous_power_w': 213.0, 'combination_resistance_ohm': 300.0, 'drive_rated_power_kw': 0.25, 'duty_cycle_pct_at_drive_rated_power': 85, 'inverter_model': 'ACU 410-01', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 213.0, 'combination_resistance_ohm': 300.0, 'drive_rated_power_kw': 0.37, 'duty_cycle_pct_at_drive_rated_power': 57, 'inverter_model': 'ACU 410-03', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 213.0, 'combination_resistance_ohm': 300.0, 'drive_rated_power_kw': 0.55, 'duty_cycle_pct_at_drive_rated_power': 39, 'inverter_model': 'ACU 410-05', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 213.0, 'combination_resistance_ohm': 300.0, 'drive_rated_power_kw': 0.75, 'duty_cycle_pct_at_drive_rated_power': 28, 'inverter_model': 'ACU 410-07', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 213.0, 'combination_resistance_ohm': 300.0, 'drive_rated_power_kw': 1.1, 'duty_cycle_pct_at_drive_rated_power': 19, 'inverter_model': 'ACU 410-09', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}, {'combination_continuous_power_w': 213.0, 'combination_resistance_ohm': 300.0, 'drive_rated_power_kw': 1.5, 'duty_cycle_pct_at_drive_rated_power': 14, 'inverter_model': 'ACU 410-11', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}]
BR 696/92 92.0 ohm 696.0 W [{'combination_continuous_power_w': 696.0, 'combination_resistance_ohm': 92.0, 'drive_rated_power_kw': 4.0, 'duty_cycle_pct_at_drive_rated_power': 17, 'inverter_model': 'ACU 410-18', 'locator': 'R04_0 p65 explicit combination row', 'quantity': 1, 'source_id': 'bonfiglioli-acu-r04-0'}]
Legacy resistor revisions are displayed separately from current specifications.
for component in rows:
specs = json.loads(component.get("extensions_json") or "{}")
if "legacy_vec501_r0_observations" in specs:
print(component["model"], "legacy VEC501R0 only", specs["legacy_vec501_r0_observations"])
BR 4000/16 legacy VEC501R0 only {'cable_section_original': 'Terminal Box', 'continuous_power_w': 4000, 'dimension_boundary': 'Original letters retained; unit not printed in table, no inferred mm normalization', 'dimension_unit': None, 'dimensions_original': {'B1': 410.0, 'B2': 380.0, 'D': 8.5, 'H': 95.0, 'L1': 690.0, 'L2': 500.0}, 'duty_cycle_pct': 10, 'intermittent_power_kw': 40.0, 'locator': 'physical PDF pp2,4', 'mass_kg': 16.5, 'maximum_supply_voltage_v': 900, 'resistance_ohm': 16.0, 'revision_boundary': 'Legacy VEC501R0 observations for exact printed type. Not asserted unchanged in R04_0 configuration; current scalar thermal switch remains unknown.', 'size': 7, 'source_id': 'bonfiglioli-br-vec501-r0', 'thermal_protection': True}
BR 432/37 legacy VEC501R0 only {'cable_section_original': '2xAWG 14, UL 1659', 'continuous_power_w': 432, 'dimension_boundary': 'Original letters retained; unit not printed in table, no inferred mm normalization', 'dimension_unit': None, 'dimensions_original': {'B1': 103.0, 'B2': 70.0, 'D': 4.5, 'H': 50.0, 'L1': 230.0, 'L2': 215.0}, 'duty_cycle_pct': 10, 'intermittent_power_kw': 4.3, 'locator': 'physical PDF pp2,4', 'mass_kg': 1.4, 'maximum_supply_voltage_v': 500, 'resistance_ohm': 37.0, 'revision_boundary': 'Legacy VEC501R0 observations for exact printed type. Not asserted unchanged in R04_0 configuration; current scalar thermal switch remains unknown.', 'size': 3, 'source_id': 'bonfiglioli-br-vec501-r0', 'thermal_protection': False}
BR 1333/12 legacy VEC501R0 only {'cable_section_original': '2xAWG 14, UL 1659', 'continuous_power_w': 1333, 'dimension_boundary': 'Original letters retained; unit not printed in table, no inferred mm normalization', 'dimension_unit': None, 'dimensions_original': {'B1': 175.0, 'B2': 165.0, 'D': 6.5, 'H': 75.0, 'L1': 330.0, 'L2': 280.0}, 'duty_cycle_pct': 10, 'intermittent_power_kw': 13.3, 'locator': 'physical PDF pp2,4', 'mass_kg': 4.5, 'maximum_supply_voltage_v': 500, 'resistance_ohm': 12.0, 'revision_boundary': 'Legacy VEC501R0 observations for exact printed type. Not asserted unchanged in R04_0 configuration; current scalar thermal switch remains unknown.', 'size': 5, 'source_id': 'bonfiglioli-br-vec501-r0', 'thermal_protection': True}
BR 2000/32 legacy VEC501R0 only {'cable_section_original': '2xAWG 14, UL 1659', 'continuous_power_w': 2000, 'dimension_boundary': 'Original letters retained; unit not printed in table, no inferred mm normalization', 'dimension_unit': None, 'dimensions_original': {'B1': 175.0, 'B2': 165.0, 'D': 6.5, 'H': 75.0, 'L1': 530.0, 'L2': 500.0}, 'duty_cycle_pct': 10, 'intermittent_power_kw': 20.0, 'locator': 'physical PDF pp2,4', 'mass_kg': 6.9, 'maximum_supply_voltage_v': 900, 'resistance_ohm': 32.0, 'revision_boundary': 'Legacy VEC501R0 observations for exact printed type. Not asserted unchanged in R04_0 configuration; current scalar thermal switch remains unknown.', 'size': 6, 'source_id': 'bonfiglioli-br-vec501-r0', 'thermal_protection': True}
BR 667/24 legacy VEC501R0 only {'cable_section_original': '2xAWG 14, UL 1659', 'continuous_power_w': 667, 'dimension_boundary': 'Original letters retained; unit not printed in table, no inferred mm normalization', 'dimension_unit': None, 'dimensions_original': {'B1': 103.0, 'B2': 70.0, 'D': 4.5, 'H': 50.0, 'L1': 300.0, 'L2': 285.0}, 'duty_cycle_pct': 10, 'intermittent_power_kw': 6.7, 'locator': 'physical PDF pp2,4', 'mass_kg': 1.8, 'maximum_supply_voltage_v': 500, 'resistance_ohm': 24.0, 'revision_boundary': 'Legacy VEC501R0 observations for exact printed type. Not asserted unchanged in R04_0 configuration; current scalar thermal switch remains unknown.', 'size': 4, 'source_id': 'bonfiglioli-br-vec501-r0', 'thermal_protection': True}
BR 8000/7 legacy VEC501R0 only {'cable_section_original': 'Terminal Box', 'continuous_power_w': 8000, 'dimension_boundary': 'Original letters retained; unit not printed in table, no inferred mm normalization', 'dimension_unit': None, 'dimensions_original': {'B1': 770.0, 'B2': 740.0, 'D': 8.5, 'H': 95.0, 'L1': 750.0, 'L2': 500.0}, 'duty_cycle_pct': 10, 'intermittent_power_kw': 80.0, 'locator': 'physical PDF pp2,4', 'mass_kg': 31.5, 'maximum_supply_voltage_v': 900, 'resistance_ohm': 7.5, 'revision_boundary': 'Legacy VEC501R0 observations for exact printed type. Not asserted unchanged in R04_0 configuration; current scalar thermal switch remains unknown.', 'size': 8, 'source_id': 'bonfiglioli-br-vec501-r0', 'thermal_protection': True}
BR 160/100 legacy VEC501R0 only {'cable_section_original': '2xAWG 14, UL 1659', 'continuous_power_w': 160, 'dimension_boundary': 'Original letters retained; unit not printed in table, no inferred mm normalization', 'dimension_unit': None, 'dimensions_original': {'B1': 40.0, 'B2': None, 'D': 5.5, 'H': 21.0, 'L1': 210.0, 'L2': 195.0}, 'duty_cycle_pct': 10, 'intermittent_power_kw': 1.6, 'locator': 'physical PDF pp2,4', 'mass_kg': 0.35, 'maximum_supply_voltage_v': 500, 'resistance_ohm': 100.0, 'revision_boundary': 'Legacy VEC501R0 observations for exact printed type. Not asserted unchanged in R04_0 configuration; current scalar thermal switch remains unknown.', 'size': 1, 'source_id': 'bonfiglioli-br-vec501-r0', 'thermal_protection': False}
BR 1330/48 legacy VEC501R0 only {'cable_section_original': '2xAWG 14, UL 1659', 'continuous_power_w': 1330, 'dimension_boundary': 'Original letters retained; unit not printed in table, no inferred mm normalization', 'dimension_unit': None, 'dimensions_original': {'B1': 175.0, 'B2': 165.0, 'D': 6.5, 'H': 75.0, 'L1': 330.0, 'L2': 280.0}, 'duty_cycle_pct': 10, 'intermittent_power_kw': 13.3, 'locator': 'physical PDF pp2,4', 'mass_kg': 4.5, 'maximum_supply_voltage_v': 900, 'resistance_ohm': 48.0, 'revision_boundary': 'Legacy VEC501R0 observations for exact printed type. Not asserted unchanged in R04_0 configuration; current scalar thermal switch remains unknown.', 'size': 5, 'source_id': 'bonfiglioli-br-vec501-r0', 'thermal_protection': True}
BR 471/136 legacy VEC501R0 only {'cable_section_original': '2xAWG 14, UL 1659', 'continuous_power_w': 471, 'dimension_boundary': 'Original letters retained; unit not printed in table, no inferred mm normalization', 'dimension_unit': None, 'dimensions_original': {'B1': 103.0, 'B2': 70.0, 'D': 4.5, 'H': 50.0, 'L1': 230.0, 'L2': 215.0}, 'duty_cycle_pct': 10, 'intermittent_power_kw': 4.7, 'locator': 'physical PDF pp2,4', 'mass_kg': 1.35, 'maximum_supply_voltage_v': 900, 'resistance_ohm': 136.0, 'revision_boundary': 'Legacy VEC501R0 observations for exact printed type. Not asserted unchanged in R04_0 configuration; current scalar thermal switch remains unknown.', 'size': 3, 'source_id': 'bonfiglioli-br-vec501-r0', 'thermal_protection': False}
BR 213/300 legacy VEC501R0 only {'cable_section_original': '2xAWG 14, UL 1659', 'continuous_power_w': 213, 'dimension_boundary': 'Original letters retained; unit not printed in table, no inferred mm normalization', 'dimension_unit': None, 'dimensions_original': {'B1': 40.0, 'B2': None, 'D': 5.5, 'H': 21.0, 'L1': 250.0, 'L2': 235.0}, 'duty_cycle_pct': 10, 'intermittent_power_kw': 2.1, 'locator': 'physical PDF pp2,4', 'mass_kg': 0.45, 'maximum_supply_voltage_v': 900, 'resistance_ohm': 300.0, 'revision_boundary': 'Legacy VEC501R0 observations for exact printed type. Not asserted unchanged in R04_0 configuration; current scalar thermal switch remains unknown.', 'size': 2, 'source_id': 'bonfiglioli-br-vec501-r0', 'thermal_protection': False}
BR 696/92 legacy VEC501R0 only {'cable_section_original': '2xAWG 14, UL 1659', 'continuous_power_w': 696, 'dimension_boundary': 'Original letters retained; unit not printed in table, no inferred mm normalization', 'dimension_unit': None, 'dimensions_original': {'B1': 103.0, 'B2': 70.0, 'D': 4.5, 'H': 50.0, 'L1': 300.0, 'L2': 285.0}, 'duty_cycle_pct': 10, 'intermittent_power_kw': 6.9, 'locator': 'physical PDF pp2,4', 'mass_kg': 1.8, 'maximum_supply_voltage_v': 900, 'resistance_ohm': 92.0, 'revision_boundary': 'Legacy VEC501R0 observations for exact printed type. Not asserted unchanged in R04_0 configuration; current scalar thermal switch remains unknown.', 'size': 4, 'source_id': 'bonfiglioli-br-vec501-r0', 'thermal_protection': True}
Optional monitoring links retain the OEM’s series and revision boundary. A documented interface does not establish that an accessory is installed.
by_id = {row["record_id"]: row for row in rows}
for component in rows:
for link in json.loads(component.get("compatibility_json") or "[]"):
target = by_id[link["equipment_record_id"]]
if target.get("equipment_category") == "control":
print(
component["model"],
"optional monitor",
target["model"],
link["conditions"],
"evidence",
link["source_id"],
link["locator"],
)
# ONS rows may represent turbine groups. Count evidence, never infer farm totals.
ons_snapshots = [
snapshot
for row in rows
if row["entity_type"] == "projects"
for snapshot in json.loads(row.get("extensions_json") or "{}").get(
"ons_wind_unit_snapshots", []
)
]
ons_units = [unit for snapshot in ons_snapshots for unit in snapshot["units"]]
print(
"ONS daily evidence; unit rows are not individual turbines or farm capacity totals",
{
"snapshots": len(ons_snapshots),
"unit_observations": len(ons_units),
"unknown_nominal_mw": sum(u["reported_nominal_mw"] is None for u in ons_units),
"reported_zero_nominal_mw": sum(u["reported_nominal_mw"] == 0 for u in ons_units),
},
)
# Count reported ONS state labels per snapshot; these are not capacity totals.
ons_state_evidence = {}
for snapshot in ons_snapshots:
states = {u["original"].get("id_estado") for u in snapshot["units"]}
for state in sorted(states, key=lambda v: v or ""):
label = state or "Unknown state"
ons_state_evidence[label] = ons_state_evidence.get(label, 0) + 1
print(
"ONS state coverage: snapshot counts, not installed MW",
dict(sorted(ons_state_evidence.items())),
)
# Deduplicate project/state pairs across unit rows and daily snapshots.
ons_project_states = set()
for row in rows:
if row["entity_type"] != "projects":
continue
for snapshot in json.loads(row.get("extensions_json") or "{}").get(
"ons_wind_unit_snapshots", []
):
for unit in snapshot["units"]:
ons_project_states.add(
(row["record_id"], unit["original"].get("id_estado") or "Unknown")
)
if ons_project_states:
state_counts = pd.Series([state for _, state in sorted(ons_project_states)]).value_counts()
fig, ax = plt.subplots(figsize=(8, 4))
state_counts.sort_index().plot.bar(ax=ax, color="#3d718e")
ax.set(
title="ONS project evidence by reported state",
ylabel="Projects with evidence",
xlabel="Reported state",
)
ax.text(
0,
-0.28,
"One project/state pair; no current fleet or capacity total inferred.",
transform=ax.transAxes,
fontsize=9,
)
fig.tight_layout()
# Separate dated registry categories, with unknowns visible and no MW aggregation.
siga_observations = [
observation
for row in rows
if row["entity_type"] == "projects"
for observation in json.loads(row.get("extensions_json") or "{}").get("epe_siga_snapshots", [])
]
if siga_observations:
categories = ["authorized_mw", "inspected_mw", "physical_guarantee_mw"]
counts = pd.DataFrame(
{
label: {
"Positive reported": sum(
o["normalized_power"][label] is not None and o["normalized_power"][label] > 0
for o in siga_observations
),
"Reported zero": sum(o["normalized_power"][label] == 0 for o in siga_observations),
"Unknown": sum(o["normalized_power"][label] is None for o in siga_observations),
}
for label in categories
}
).T
fig, ax = plt.subplots(figsize=(9, 4))
counts.plot.barh(stacked=True, ax=ax, color=["#3d718e", "#e7ab54", "#9a9a9a"])
dates = sorted({o["observation_date"] for o in siga_observations})
ax.set(
title="SIGA reported category completeness — " + ", ".join(dates),
xlabel="Registry observations; not summed MW",
ylabel="",
)
ax.text(
0,
-0.3,
"Physical guarantee is not installed capacity; unresolved scope exclusions remain.",
transform=ax.transAxes,
fontsize=9,
)
fig.tight_layout()
# Counts of linked projects by dated state partition, not a national inventory.
if siga_observations:
state_projects: dict[tuple[str, str], set[str]] = {}
for row in rows:
if row["entity_type"] != "projects":
continue
for observation in json.loads(row.get("extensions_json") or "{}").get(
"epe_siga_snapshots", []
):
key = (observation["original"]["sigufprincipal"], observation["observation_date"])
state_projects.setdefault(key, set()).add(row["record_id"])
keys = sorted(state_projects)
fig, ax = plt.subplots(figsize=(9, 3.5))
ax.barh(
[f"{state} · {date}" for state, date in keys],
[len(state_projects[k]) for k in keys],
color="#3d718e",
)
ax.set(
title="SIGA evidence linked to existing projects",
xlabel="Distinct linked projects per state and date",
)
ax.text(
0,
-0.32,
"Selected state partitions only; unmatched identities held. "
"No capacity eligibility change.",
transform=ax.transAxes,
fontsize=9,
)
fig.tight_layout()
# Exact table columns, with ranges plotted as options rather than installations.
oem_columns = [
observation
for row in rows
if row["entity_type"] == "equipment"
for observation in json.loads(row.get("extensions_json") or "{}").get(
"oem_table_observations", []
)
if observation["source_id"] in row["sources"]
]
if oem_columns:
fig, ax = plt.subplots(figsize=(9, 4))
for observation in oem_columns:
values = observation["values"]
diameter = values["rotor_diameter_m"]
low, high = values["hub_height_range_m"]
ax.plot([diameter, diameter], [low, high], color="#3d718e", alpha=0.5)
ax.scatter([diameter, diameter], [low, high], s=12, color="#3d718e")
ax.set(
title="Windey 2022 exact-model tables: published hub options",
xlabel="Explicit rotor diameter (m)",
ylabel="Published hub-height option range (m)",
)
ax.text(
0,
-0.3,
f"{len(oem_columns)} reviewed model columns; overlapping options are not installations. "
"Density and operating mode unknown; no performance comparison.",
transform=ax.transAxes,
fontsize=8,
)
fig.tight_layout()
# Review completeness is separate from the number of successfully linked farms.
epe_reviews = []
for ledger in sorted((ROOT / "catalogues/wind/research").glob("*-epe-review.json")):
report = json.loads(ledger.read_text())
if report.get("complete_selected_partition") and report.get("all_reviewed_candidates"):
state = report["all_reviewed_candidates"][0]["original"]["sigufprincipal"]
epe_reviews.append(
{"State": state, "Linked": report["enriched"], "Identity held": report["deferred"]}
)
if epe_reviews:
review_counts = pd.DataFrame(epe_reviews).set_index("State").sort_index()
fig, ax = plt.subplots(figsize=(9, 6))
review_counts.plot.barh(stacked=True, ax=ax, color=["#3d718e", "#9a9a9a"])
ax.set(
title="Complete selected SIGA partitions: identity review outcomes",
xlabel="Registry entries; not MW",
)
fig.tight_layout()
# A complete empty ID query is distinct from an unqueried state or missing data.
coverage_audits = sorted((ROOT / "catalogues/wind/research").glob("*-epe-coverage.json"))
if epe_reviews and coverage_audits:
audit = json.loads(coverage_audits[-1].read_text())
empty_states = ", ".join(audit["result"]["empty_states"])
fig.text(
0.02,
0.01,
f"Explicit empty layer partitions: {empty_states}.\n"
"Empty registry query is not zero wind capacity. Held identities remain excluded.",
fontsize=8,
)
fig.tight_layout(rect=(0, 0.08, 1, 1))
# Lender design envelopes stay out of scalar geometry and fleet distributions.
print("Source/revision-qualified design envelopes; not selected or installed turbines:")
for row in rows:
envelopes = json.loads(row.get("extensions_json") or "{}").get("design_envelopes", [])
for envelope in envelopes:
print(row["name"], envelope["revision"], envelope["locator"])
print(
"Proposed rotor/hub ranges (m):",
envelope["rotor_diameter_range_m"],
envelope["hub_height_range_m"],
)
print("Scalar rotor/hub remain:", row.get("rotor_diameter_m"), row.get("hub_height_m"))
print(envelope["conditions"])
ACS880-77LC-2503A/2328A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-87LC-4000A/3800A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-87LC-8000A/7600A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-87LC-5006A/4656A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-87LC-4000A/4134A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-77LC-3372A/3136A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-87LC-8000A/8268A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-77LC-1686A/1568A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-77LC-5006A/4656A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
NEXA-21 optional monitor NETA-21 Optional extension for NETA-21 only; no direct turbine or converter compatibility inferred. Wind context is the documented NETA-21 monitoring application. evidence abb-neta21-revq-20260918 Rev Q pp21–24 layout and Installing NEXA-21 to NETA-21
ACS880-77LC-1720A/1600A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-87LC-6604A/6144A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-87LC-3302A/3072A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-87LC-1686A/1568A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-77LC-860A/800A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ACS880-87LC-2503A/2328A-7 optional monitor NETA-21 Optional accessory for explicitly named ACS880-77LC/-87LC series; 2020 system-document claim, not evidence of installation or retrofit approval for each historical 2018 configuration. evidence abb-acs880-system-revc-20200427 Rev C pp24–25
ONS daily evidence; unit rows are not individual turbines or farm capacity totals {'snapshots': 340, 'unit_observations': 687, 'unknown_nominal_mw': 0, 'reported_zero_nominal_mw': 0}
ONS state coverage: snapshot counts, not installed MW {'BA': 66, 'CE': 45, 'PE': 25, 'PI': 29, 'RN': 101, 'RS': 64, 'SC': 10}
Source/revision-qualified design envelopes; not selected or installed turbines:
Aysha I Wind IPP Version03 dated2026-06-04; approved2026-06-05 Table2-2 printed pp4–5, PDFpp42–43
Proposed rotor/hub ranges (m): [182, 210] [120, 130]
Scalar rotor/hub remain: None None
Worst-case assessment envelope; supplier selection ongoing. Ranges are not Cartesian OEM configurations or installed inventory.
Dated OEM supply awards do not select regional equipment configurations.
print("OEM supply announcements; not installed fleet distributions:")
for row in projects.to_dict("records"):
for award in json.loads(row.get("extensions_json") or "{}").get("supply_awards", []):
print(row["name"], award["published_at"], award["manufacturer"], award["model_mentioned"])
print(award["identity_basis"], award["configuration_status"])
print("Installed turbine count remains:", row.get("turbine_count"))
OEM supply announcements; not installed fleet distributions:
Aysha I Wind IPP 2026-08-19 Windey WD200-7700
Explicit Aysha I name, Ethiopia and AMEA Power developer match IFC49251; separate AyshaII grid connection not assigned unresolved
Installed turbine count remains: nan
A common administrative procedure does not establish a common physical farm.
print("Former joint administrative procedures; capacity additivity not established:")
for row in rows:
relation = json.loads(row.get("extensions_json") or "{}").get("relationships", {})
if relation.get("relationship_type") == "former_joint_administrative_procedure":
print(row["name"], relation["related_project_name"], relation["former_procedure"])
print("Separated:", relation["separated_date"], "aggregation:", row["aggregation_role"])
# Numeric consistency is a review screen, not independent performance validation.
print("OEM exact tables: reported cells, withheld scalars and unknown revisions")
for row in rows:
table = json.loads(row.get("extensions_json") or "{}").get("oem_numeric_table")
if table:
print(
row["model"],
"revision",
table["revision"],
"original bytes",
table["original_bytes_available"],
"area m2",
row.get("swept_area_m2"),
"cut-out m/s",
row.get("cut_out_m_s"),
"held",
sorted(json.loads(row.get("conflicts_json") or "{}")),
)
print("Floating prototype depth: floater and anchors are different boundaries")
for row in rows:
design = json.loads(row.get("extensions_json") or "{}").get("environmental_design")
if design and "floater_seabed_elevation_m" in design:
print(
row["name"],
"floater seabed elevation m",
design["floater_seabed_elevation_m"],
"datum",
design["vertical_reference"],
"anchor approximate depth m",
design["anchor_approx_depth_m"],
"capacity role",
row["aggregation_role"],
)
# Operator MW boundaries and date precision stay separate from installed capacity.
print("Dated operator observations: contracted/gross MW, not additive installed capacity")
for row in rows:
for observation in json.loads(row.get("extensions_json") or "{}").get(
"operator_portfolio_observations", []
):
facts = observation["facts"]
print(
row["name"],
observation["as_of"],
facts.get("status", "unknown"),
facts["capacity_basis"],
facts["capacity_mw"],
facts["cod"],
facts["cod_precision"],
facts["count_times_rating_check"],
row["aggregation_role"],
)
print("Unknown exact models remain unknown; dated ownership does not overwrite earlier shares.")
Former joint administrative procedures; capacity additivity not established:
Cerro de Magaña Pasama PEol-897 AC
Separated: 2026-04-20 aggregation: unresolved
OEM exact tables: reported cells, withheld scalars and unknown revisions
SI-16050 revision None original bytes False area m2 20106.0 cut-out m/s 25.0 held []
SI-16850 revision None original bytes False area m2 22167.0 cut-out m/s None held ['cut_out_m_s']
SI-230100 revision None original bytes False area m2 None cut-out m/s 25.0 held []
SI-18342 revision None original bytes False area m2 26302.0 cut-out m/s 20.0 held []
SI-20480 revision None original bytes False area m2 32685.0 cut-out m/s 22.0 held []
SI-172625 revision None original bytes False area m2 23235.0 cut-out m/s 25.0 held []
SI-19350 revision None original bytes False area m2 None cut-out m/s 22.0 held []
SI-18572 revision None original bytes False area m2 None cut-out m/s 25.0 held ['swept_area_m2']
SI-19342 revision None original bytes False area m2 29255.0 cut-out m/s 20.0 held []
SI-19580 revision None original bytes False area m2 None cut-out m/s 25.0 held ['swept_area_m2']
Floating prototype depth: floater and anchors are different boundaries
WHEEL PLOCAN prototype floater seabed elevation m -90 datum Port of Las Palmas reference anchor approximate depth m 100 capacity role unresolved
Dated operator observations: contracted/gross MW, not additive installed capacity
Mława Wind 2024-03-31 operational contracted 37 2022-04-01 day {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 36.125} unresolved
Hywind Scotland Pilot Park (Hywind 2) Demonstrator 2024-03-31 operational contracted 30 None None {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 30} independent
Grajewo Wind 2024-03-31 operational contracted 14 2022-04-01 day {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 14.875} unresolved
London Array 2024-03-31 operational contracted 630 None None {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 630.0} unresolved
Taiba N'Daiye Wind 2024-03-31 operational gross_reported 159 2021-07 month {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 158.7} unresolved
Baltic Eagle Offshore Wind 2024-03-31 under_construction gross_reported 476 None None {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 475.0} unresolved
Krnovo Wind 2024-03-31 operational contracted 72 2017-11-02 day {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 71.5} unresolved
West Bakr Wind 2024-03-31 operational gross_reported 252 2021-11 month {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 252.0} unresolved
Tafila Wind 2024-03-31 operational contracted 117 2015-09-16 day {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 114} unresolved
Dumat Al Jandal 2024-03-31 operational contracted 400 2022-07-01 day {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 415.8} independent
Zarafshan Wind 2024-03-31 under_construction gross_reported 500 None None {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 499.5} unresolved
Perdekraal East Wind 2024-03-31 operational gross_reported 113 2020-10 month {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 112.608} unresolved
Cibuk Wind 2024-03-31 operational contracted 158 2019-10-15 day {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 156.75} unresolved
Kangnas Wind 2024-03-31 operational gross_reported 143 2020-11 month {'kind': 'arithmetic_check_only', 'supplies_installed_capacity': False, 'unit': 'MW', 'value': 143.106} unresolved
Unknown exact models remain unknown; dated ownership does not overwrite earlier shares.
Synchronization is not commercial operation or a measured capacity total.
print("Grid connection milestones; reliability trials and COD remain separate")
for row in rows:
for milestone in json.loads(row.get("extensions_json") or "{}").get(
"grid_connection_observations", []
):
print(
row["name"],
milestone["event_date"],
milestone["scope"],
"connected turbines",
milestone["connected_turbines"],
"published",
milestone["published_at"],
milestone["remaining_milestones"],
"commissioned MW",
row.get("commissioned_capacity_mw"),
)
# Complete offshore application layers remain separate from operating capacity.
offshore_registry = [
json.loads(row.get("extensions_json") or "{}")["vindbrukskollen_offshore"]
for row in rows
if "vindbrukskollen_offshore" in json.loads(row.get("extensions_json") or "{}")
]
print("Swedish offshore registry applications; unclassified MW are not summed")
print(pd.Series([r["source_fields"]["ArendeStatus"] for r in offshore_registry]).value_counts())
print(
"Unknown capacity observations:",
sum(r["reported_capacity_mw"] is None for r in offshore_registry),
"Reported zeros:",
sum(r["reported_capacity_mw"] == 0 for r in offshore_registry),
"All selected areas excluded pending physical-scope reconciliation; foundations unknown",
)
Grid connection milestones; reliability trials and COD remain separate
Al-Ghat 2026-06-10 all_turbines connected turbines 80 published 2026-07-03 168-hour full-site reliability trial subsequent; commercial operation date not reported commissioned MW None
Swedish offshore registry applications; unclassified MW are not summed
Tillståndsansökan avslagen 27
Inte aktuell eller återkallad 17
Samråd inför tillståndsansökan 10
Inledande undersökningar 7
Tillståndsansökan beviljad 6
Tillståndsansökan inlämnad 2
Name: count, dtype: int64
Unknown capacity observations: 59 Reported zeros: 0 All selected areas excluded pending physical-scope reconciliation; foundations unknown
Electrical circuit roles and original units must survive equipment comparison.
print("Dated OEM electrical tables; active/apparent power and AC/DC remain separate")
for row in rows:
electrical = json.loads(row.get("extensions_json") or "{}").get("electrical_table")
if electrical is None:
continue
print(row["model"], electrical["role"], "scalar turbine kW:", row.get("rated_power_kw"))
for observation in electrical["observations"]:
print(observation["role"], observation["locator"], observation["conditions"])
print(pd.DataFrame(observation["quantities"]).to_string(index=False))
Dated OEM electrical tables; active/apparent power and AC/DC remain separate
ACS800-104LC-1075-7 rotor-side converter scalar turbine kW: None
rotor-side p122 1075 {'Imax': '10 seconds at start, otherwise converter-temperature limited', 'derating': 'Coolant inlet45–50 C:2% current/C. Ambient50–55 C:1%/C. Altitude1000–4000 m:1%/100 m; above2000 m contact ABB.', 'frequency_hz': 50, 'heavy_duty': '50 percent overload for1 minute in every5 minutes', 'light_duty': '10 percent overload for1 minute in every5 minutes', 'locator': 'pp121–122 ratings and definitions', 'no_overload_temperature_c': 45, 'rating_supply_v_ac': 690}
quantity unit value
Icont.max A AC 898
Scont.max kVA 1074
Imax A AC 1344
IN A 863
Ihd A 672
ACS800-67LC-2035/1125-7 whole liquid-cooled wind converter assembly scalar turbine kW: None
ACS800-204LC-0865-7+E205 grid-side converter scalar turbine kW: None
grid-side p121 0865 {'Imax': '10 seconds at start, otherwise converter-temperature limited', 'derating': 'Coolant inlet45–50 C:2% current/C. Ambient50–55 C:1%/C. Altitude1000–4000 m:1%/100 m; above2000 m contact ABB.', 'frequency_hz': 50, 'heavy_duty': '50 percent overload for1 minute in every5 minutes', 'light_duty': '10 percent overload for1 minute in every5 minutes', 'locator': 'pp121–122 ratings and definitions', 'no_overload_temperature_c': 45, 'rating_supply_v_ac': 690}
quantity unit value
Icont.max A AC 720
Scont.max kVA 860
Qcont.max kVAr 706
Imax A AC 1077
ACS800-104LC-1595-7 rotor-side converter scalar turbine kW: None
rotor-side p122 1595 {'Imax': '10 seconds at start, otherwise converter-temperature limited', 'derating': 'Coolant inlet45–50 C:2% current/C. Ambient50–55 C:1%/C. Altitude1000–4000 m:1%/100 m; above2000 m contact ABB.', 'frequency_hz': 50, 'heavy_duty': '50 percent overload for1 minute in every5 minutes', 'light_duty': '10 percent overload for1 minute in every5 minutes', 'locator': 'pp121–122 ratings and definitions', 'no_overload_temperature_c': 45, 'rating_supply_v_ac': 690}
quantity unit value
Icont.max A AC 1334
Scont.max kVA 1594
Imax A AC 1996
IN A 1281
Ihd A 998
W2E143-AA09-01 Auxiliary enclosure cooling scalar turbine kW: None
Fan motor electrical input; not turbine output p5 section3.2 frequency column 230 VAC single phase 50 Hz; free-air method fa; CE nominal OEM values
quantity unit value
frequency Hz 50.00
speed rpm 2800.00
input_power W 24.00
current A 0.12
starting_current A 0.26
capacitor uF 0.75
capacitor_voltage VDB 400.00
Fan motor electrical input; not turbine output p5 section3.2 frequency column 230 VAC single phase 60 Hz; free-air method fa; CE nominal OEM values
quantity unit value
frequency Hz 60.00
speed rpm 3300.00
input_power W 26.00
current A 0.11
starting_current A 0.26
capacitor uF 0.75
capacitor_voltage VDB 400.00
ACS800-67-0480/0580-7 whole wind converter assembly scalar turbine kW: None
NPBU-42 auxiliary control board scalar turbine kW: None
board power supply p91 Boards; NPBU-42 Nominal auxiliary board supply; maximum current unknown where table has dash
quantity unit value
nominal_voltage V DC 24.000
nominal_current A 0.200
maximum_current A 0.235
ACS800-67-0480/1160-7 whole wind converter assembly scalar turbine kW: None
ACS800-204LC-1125-7+E205 grid-side converter scalar turbine kW: None
grid-side p121 1125 {'Imax': '10 seconds at start, otherwise converter-temperature limited', 'derating': 'Coolant inlet45–50 C:2% current/C. Ambient50–55 C:1%/C. Altitude1000–4000 m:1%/100 m; above2000 m contact ABB.', 'frequency_hz': 50, 'heavy_duty': '50 percent overload for1 minute in every5 minutes', 'light_duty': '10 percent overload for1 minute in every5 minutes', 'locator': 'pp121–122 ratings and definitions', 'no_overload_temperature_c': 45, 'rating_supply_v_ac': 690}
quantity unit value
Icont.max A AC 941
Scont.max kVA 1124
Qcont.max kVAr 922
Imax A AC 1407
ACS800-104-0580-7 module type; grid-side and rotor-side scalar turbine kW: None
rotor-side p89 Rotor-side converter IEC ratings; 0580 {'Imax': '10 seconds at start, otherwise converter-temperature limited', 'derating': 'Ambient >40 to50 C: current reduced1%/C; Icont.max not allowed above40 C. Altitude1000–4000 m:1%/100 m; above2000 m contact ABB.', 'frequency_hz': [50, 60], 'heavy_duty': '50 percent overload for 1 minute in every 5 minutes', 'light_duty': '10 percent overload for 1 minute in every 5 minutes', 'locator': 'pp89–90 IEC ratings and definitions', 'no_overload_ambient_c': 40, 'rating_supply_v_ac': 690}
quantity unit value
Icont.max A AC 486.0
Imax A AC 727.0
Pcont.max kW AC 450.0
I2N A AC 467.0
PN kW AC 450.0
I2hd A AC 364.0
Phd kW AC 315.0
heat_dissipation kW 7.4
grid-side p89 Grid-side converter IEC ratings; -0580-7 {'Imax': '10 seconds at start, otherwise converter-temperature limited', 'derating': 'Ambient >40 to50 C: current reduced1%/C; Icont.max not allowed above40 C. Altitude1000–4000 m:1%/100 m; above2000 m contact ABB.', 'frequency_hz': [50, 60], 'heavy_duty': '50 percent overload for 1 minute in every 5 minutes', 'light_duty': '10 percent overload for 1 minute in every 5 minutes', 'locator': 'pp89–90 IEC ratings and definitions', 'no_overload_ambient_c': 40, 'rating_supply_v_ac': 690}
quantity unit value
Icont.max AC A AC 400.0
Icont.max DC A DC 485.0
Imax A DC 726.0
SN kVA 478.0
Pcont.max kW DC 473.0
I2N A DC 466.0
PN kW DC 454.0
I2hd A DC 363.0
Phd kW DC 354.0
heat_dissipation_including_ALCL-15-7 kW 14.6
ACS800-104LC-0555-7+E205 physical module listed in grid-side and rotor-side assembly columns scalar turbine kW: None
ACS800-104LC-1375-7 rotor-side converter scalar turbine kW: None
rotor-side p122 1375 {'Imax': '10 seconds at start, otherwise converter-temperature limited', 'derating': 'Coolant inlet45–50 C:2% current/C. Ambient50–55 C:1%/C. Altitude1000–4000 m:1%/100 m; above2000 m contact ABB.', 'frequency_hz': 50, 'heavy_duty': '50 percent overload for1 minute in every5 minutes', 'light_duty': '10 percent overload for1 minute in every5 minutes', 'locator': 'pp121–122 ratings and definitions', 'no_overload_temperature_c': 45, 'rating_supply_v_ac': 690}
quantity unit value
Icont.max A AC 1143
Scont.max kVA 1366
Imax A AC 1710
IN A 1097
Ihd A 855
ACS800-104LC-0705-7+E205 physical module listed in grid-side and rotor-side assembly columns scalar turbine kW: None
ALCL-15LC-7 Liquid-cooled grid-side LCL filter scalar turbine kW: None
LCL components p125 LCL filter component values Values for exact filter type; no tolerance, frequency or independent performance validation supplied
quantity unit value
L1 µH 106
L2 µH 190
C µF 64
ACS800-67LC-1375/1125-7 whole liquid-cooled wind converter assembly scalar turbine kW: None
ACS800-104-1160-7 module type; rotor-side scalar turbine kW: None
rotor-side p89 Rotor-side converter IEC ratings; 1160 {'Imax': '10 seconds at start, otherwise converter-temperature limited', 'derating': 'Ambient >40 to50 C: current reduced1%/C; Icont.max not allowed above40 C. Altitude1000–4000 m:1%/100 m; above2000 m contact ABB.', 'frequency_hz': [50, 60], 'heavy_duty': '50 percent overload for 1 minute in every 5 minutes', 'light_duty': '10 percent overload for 1 minute in every 5 minutes', 'locator': 'pp89–90 IEC ratings and definitions', 'no_overload_ambient_c': 40, 'rating_supply_v_ac': 690}
quantity unit value
Icont.max A AC 953.0
Imax A AC 1425.0
Pcont.max kW AC 900.0
I2N A AC 914.0
PN kW AC 900.0
I2hd A AC 713.0
Phd kW AC 630.0
heat_dissipation kW 14.4
ACS800-204LC-0575-7+E205 grid-side converter scalar turbine kW: None
grid-side p121 0575 {'Imax': '10 seconds at start, otherwise converter-temperature limited', 'derating': 'Coolant inlet45–50 C:2% current/C. Ambient50–55 C:1%/C. Altitude1000–4000 m:1%/100 m; above2000 m contact ABB.', 'frequency_hz': 50, 'heavy_duty': '50 percent overload for1 minute in every5 minutes', 'light_duty': '10 percent overload for1 minute in every5 minutes', 'locator': 'pp121–122 ratings and definitions', 'no_overload_temperature_c': 45, 'rating_supply_v_ac': 690}
quantity unit value
Icont.max A AC 480
Scont.max kVA 574
Qcont.max kVAr 470
Imax A AC 718
ACS800-67LC-1595/0865-7 whole liquid-cooled wind converter assembly scalar turbine kW: None
ALCL-24LC-7 Liquid-cooled grid-side LCL filter scalar turbine kW: None
LCL components p125 LCL filter component values Values for exact filter type; no tolerance, frequency or independent performance validation supplied
quantity unit value
L1 µH 70
L2 µH 127
C µF 96
ACS800-67LC-1375/0575-7 whole liquid-cooled wind converter assembly scalar turbine kW: None
ALCL-25LC-7 Liquid-cooled grid-side LCL filter scalar turbine kW: None
LCL components p125 LCL filter component values Values for exact filter type; no tolerance, frequency or independent performance validation supplied
quantity unit value
L1 µH 54
L2 µH 97
C µF 125
ACS800-104LC-2035-7 rotor-side converter scalar turbine kW: None
rotor-side p122 2035 {'Imax': '10 seconds at start, otherwise converter-temperature limited', 'derating': 'Coolant inlet45–50 C:2% current/C. Ambient50–55 C:1%/C. Altitude1000–4000 m:1%/100 m; above2000 m contact ABB.', 'frequency_hz': 50, 'heavy_duty': '50 percent overload for1 minute in every5 minutes', 'light_duty': '10 percent overload for1 minute in every5 minutes', 'locator': 'pp121–122 ratings and definitions', 'no_overload_temperature_c': 45, 'rating_supply_v_ac': 690}
quantity unit value
Icont.max A AC 1697
Scont.max kVA 2028
Imax A AC 2539
IN A 1629
Ihd A 1269
ACS800-104-0770-7 module type; rotor-side scalar turbine kW: None
rotor-side p89 Rotor-side converter IEC ratings; 0770 {'Imax': '10 seconds at start, otherwise converter-temperature limited', 'derating': 'Ambient >40 to50 C: current reduced1%/C; Icont.max not allowed above40 C. Altitude1000–4000 m:1%/100 m; above2000 m contact ABB.', 'frequency_hz': [50, 60], 'heavy_duty': '50 percent overload for 1 minute in every 5 minutes', 'light_duty': '10 percent overload for 1 minute in every 5 minutes', 'locator': 'pp89–90 IEC ratings and definitions', 'no_overload_ambient_c': 40, 'rating_supply_v_ac': 690}
quantity unit value
Icont.max A AC 645
Imax A AC 965
Pcont.max kW AC 605
I2N A AC 620
PN kW AC 605
I2hd A AC 482
Phd kW AC 384
heat_dissipation kW 10
ACS800-67LC-1075/0575-7 whole liquid-cooled wind converter assembly scalar turbine kW: None
APBU-44 auxiliary control board scalar turbine kW: None
board power supply p91 Boards; APBU-44 Nominal auxiliary board supply; maximum current unknown where table has dash
quantity unit value
nominal_voltage V DC 24.0
nominal_current A 0.2
maximum_current A NaN
ACS800-67-0480/0770-7 whole wind converter assembly scalar turbine kW: None
Cohort inventories retain project boundaries and unknown geography.
nve = [
(row, json.loads(row.get("extensions_json") or "{}")["nve_registry"])
for row in rows
if "nve_registry" in json.loads(row.get("extensions_json") or "{}")
]
print("NVE cohort inventory: normal-year production is modeled; no capacity factor")
print(
"Projects:",
len(nve),
"Mixed active model labels:",
sum(item["mixed_active_model_labels"] for _, item in nve),
"Unknown coordinates:",
sum(row.get("latitude") is None for row, _ in nve),
"Excluded scopes:",
sum(row["aggregation_role"] == "unresolved" for row, _ in nve),
)
print("First-stage dates and plant mean hub/rotor geometry remain qualified source fields")
# Dated warranty alternatives must not collapse into a single duration.
for row in rows:
spec = json.loads(row.get("extensions_json") or "{}").get("qualified_specifications", {})
warranty = spec.get("specifications", {}).get("warranty")
if warranty:
print(
row["model"],
"dated conditional warranty:",
warranty,
"scalar years:",
row.get("warranty_years"),
)
# Auxiliary electricity requirements retain each OEM frequency/method condition.
# They are never included in turbine output or rotor-specific-power summaries.
for item in rows:
if item.get("equipment_category") == "cooling_fan":
table = json.loads(item["extensions_json"])["electrical_table"]
print("Auxiliary fan:", item["model"], table["observations"])
# Connector counterpart rows are references, not an installed turbine inventory.
connectors = [
json.loads(row.get("extensions_json") or "{}")["connector_specifications"]
for row in rows
if row.get("equipment_category") == "connector"
]
print(
"Exact OEM connector parts:",
len(connectors),
"Unverified installed revisions:",
sum(not item["installed_revision_verified"] for item in connectors),
"Counterpart rows:",
sum(len(item["assembly_references"]) for item in connectors),
)
print("Current OEM electrical conditions are not ABB2018 installed revisions or turbine power")
# A complete proposed layout is not an as-built or commissioned inventory.
print("Published individual layout positions: original CRS; geographic transform unresolved")
for unit in rows:
layout = json.loads(unit.get("extensions_json") or "{}").get("published_layout")
if layout:
print(
unit["name"],
unit["status"],
layout["crs"],
layout["easting"],
layout["northing"],
layout["altitude"],
"m; not installed MW",
"published resolution (m):",
layout.get("published_resolution_m"),
"positional accuracy (m):",
layout.get("position_accuracy_m"),
)
print("Repowering generations preserve predecessor links and exclude unresolved scopes")
for project in rows:
if project.get("replaces_record_id"):
print(
project["name"],
project["replaces_record_id"],
project["aggregation_role"],
project.get("commissioning_date"),
project.get("retirement_date"),
)
# Compare cable geometry only within explicit OEM configurations. Linear mass
# remains kg/m; installed length and installed product revision are not inferred.
cable_points = []
for item in rows:
if item.get("equipment_category") == "power_cable":
specs = json.loads(item["extensions_json"])["cable_specifications"]
cable_points.append(
(
item["model"],
specs["conductor_cross_section"]["value"],
specs["approximate_linear_mass"]["value"],
)
)
if cable_points:
fig, ax = plt.subplots(figsize=(8, 4))
for name, section, mass in cable_points:
if section is not None and mass is not None:
ax.scatter(
section,
mass,
marker="^" if "3x1x" in name else "o",
color="tab:blue" if "24kV" in name else "tab:orange",
)
ax.set(
xlabel="Conductor cross-section [mm²]",
ylabel="Approximate linear mass [kg/m]",
title="Nexans listed cable configurations: specifications, not installed inventory",
)
ax.text(
0.02,
0.98,
"Blue: 24 kV; orange: 36 kV\nTriangle: 3x1-core; circle: 1-core",
va="top",
transform=ax.transAxes,
)
fig.tight_layout()
print("Cable configurations:", len(cable_points), "; installed length and total mass unknown")
# Complete operator fact cards preserve tower height without calling it hub height.
operator_cards = []
for row in rows:
card = json.loads(row.get("extensions_json") or "{}").get("operator_fact_cards")
if card:
facts = card["facts"]
operator_cards.append(
{
"name": row["name"],
"Rotor diameter [m]": facts["rotor_m"]["value"],
"Reported tower height [m]": facts["tower_height_m"]["value"],
}
)
if operator_cards:
fig, ax = plt.subplots(figsize=(9, 4))
pd.DataFrame(operator_cards).set_index("name").sort_index().plot.barh(ax=ax)
ax.set(title="Fosen operator geometry · tower height is not inferred hub height", xlabel="m")
fig.tight_layout()
print(
"Operator annual output lacks period and gross/net boundary; "
"no capacity factors calculated."
)
NVE cohort inventory: normal-year production is modeled; no capacity factor
Projects: 49 Mixed active model labels: 2 Unknown coordinates: 49 Excluded scopes: 49
First-stage dates and plant mean hub/rotor geometry remain qualified source fields
ACS800-67-0480/0580-7 dated conditional warranty: {'installation_months': 12, 'local_contract_override': True, 'manufacture_months': 24, 'qualification': 'Dated2010manual terms, not a current commercial warranty offer', 'selection': 'whichever occurs first'} scalar years: None
ACS800-67-0480/1160-7 dated conditional warranty: {'installation_months': 12, 'local_contract_override': True, 'manufacture_months': 24, 'qualification': 'Dated2010manual terms, not a current commercial warranty offer', 'selection': 'whichever occurs first'} scalar years: None
ACS800-67-0480/0770-7 dated conditional warranty: {'installation_months': 12, 'local_contract_override': True, 'manufacture_months': 24, 'qualification': 'Dated2010manual terms, not a current commercial warranty offer', 'selection': 'whichever occurs first'} scalar years: None
Auxiliary fan: W2E143-AA09-01 [{'conditions': '230 VAC single phase 50 Hz; free-air method fa; CE nominal OEM values', 'locator': 'p5 section3.2 frequency column', 'quantities': [{'quantity': 'frequency', 'unit': 'Hz', 'value': 50}, {'quantity': 'speed', 'unit': 'rpm', 'value': 2800}, {'quantity': 'input_power', 'unit': 'W', 'value': 24}, {'quantity': 'current', 'unit': 'A', 'value': 0.12}, {'quantity': 'starting_current', 'unit': 'A', 'value': 0.26}, {'quantity': 'capacitor', 'unit': 'uF', 'value': 0.75}, {'quantity': 'capacitor_voltage', 'unit': 'VDB', 'value': 400}], 'role': 'Fan motor electrical input; not turbine output'}, {'conditions': '230 VAC single phase 60 Hz; free-air method fa; CE nominal OEM values', 'locator': 'p5 section3.2 frequency column', 'quantities': [{'quantity': 'frequency', 'unit': 'Hz', 'value': 60}, {'quantity': 'speed', 'unit': 'rpm', 'value': 3300}, {'quantity': 'input_power', 'unit': 'W', 'value': 26}, {'quantity': 'current', 'unit': 'A', 'value': 0.11}, {'quantity': 'starting_current', 'unit': 'A', 'value': 0.26}, {'quantity': 'capacitor', 'unit': 'uF', 'value': 0.75}, {'quantity': 'capacitor_voltage', 'unit': 'VDB', 'value': 400}], 'role': 'Fan motor electrical input; not turbine output'}]
Exact OEM connector parts: 22 Unverified installed revisions: 22 Counterpart rows: 41
Current OEM electrical conditions are not ABB2018 installed revisions or turbine power
Published individual layout positions: original CRS; geographic transform unresolved
Armus / AR_05 announced EPSG:25830 385413.0 4658977.0 882.0 m; not installed MW published resolution (m): 1 positional accuracy (m): None
Anjana / ANJ-09 announced EPSG:25830 417879.0 4749520.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Armus / AR_02 announced EPSG:25830 385899.0 4656051.0 870.0 m; not installed MW published resolution (m): 1 positional accuracy (m): None
Anjana / ANJ-07 announced EPSG:25830 410357.0 4750107.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Ado / AD-10 announced EPSG:25829 514714.0 4748611.0 None m; not installed MW published resolution (m): 1 positional accuracy (m): None
Ado / AD-09 announced EPSG:25829 513949.0 4748482.0 None m; not installed MW published resolution (m): 1 positional accuracy (m): None
Ado / AD-06 announced EPSG:25829 512705.0 4748989.0 None m; not installed MW published resolution (m): 1 positional accuracy (m): None
Anjana / ANJ-11 announced EPSG:25830 418962.0 4749771.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Anjana / ANJ-10 announced EPSG:25830 418224.0 4749540.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Anjana / ANJ-04 announced EPSG:25830 409434.0 4751126.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Anjana / ANJ-12 announced EPSG:25830 419331.0 4749963.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Anjana / ANJ-13 announced EPSG:25830 419694.0 4750289.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Ado / AD-01 announced EPSG:25829 513121.0 4750151.0 None m; not installed MW published resolution (m): 1 positional accuracy (m): None
Ado / AD-07 announced EPSG:25829 512946.0 4748589.0 None m; not installed MW published resolution (m): 1 positional accuracy (m): None
Anjana / ANJ-05 announced EPSG:25830 409714.0 4750616.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Anjana / ANJ-08 announced EPSG:25830 417480.0 4749504.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Armus / AR_01 announced EPSG:25830 385430.0 4655314.0 869.0 m; not installed MW published resolution (m): 1 positional accuracy (m): None
Anjana / ANJ-01 announced EPSG:25830 407282.0 4753425.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Anjana / ANJ-02 announced EPSG:25830 407269.0 4752607.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Anjana / ANJ-17 announced EPSG:25830 419620.0 4751016.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Ado / AD-02 announced EPSG:25829 513513.0 4750002.0 None m; not installed MW published resolution (m): 1 positional accuracy (m): None
Ado / AD-05 announced EPSG:25829 514871.0 4749264.0 None m; not installed MW published resolution (m): 1 positional accuracy (m): None
Ado / AD-04 announced EPSG:25829 514166.0 4749521.0 None m; not installed MW published resolution (m): 1 positional accuracy (m): None
Ado / AD-03 announced EPSG:25829 513812.0 4749720.0 None m; not installed MW published resolution (m): 1 positional accuracy (m): None
Anjana / ANJ-15 announced EPSG:25830 420352.0 4750710.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Armus / AR_03 announced EPSG:25830 385698.0 4657557.0 870.0 m; not installed MW published resolution (m): 1 positional accuracy (m): None
Anjana / ANJ-03 announced EPSG:25830 407905.0 4751645.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Anjana / ANJ-16 announced EPSG:25830 419947.0 4751142.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Anjana / ANJ-14 announced EPSG:25830 420049.0 4750243.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Anjana / ANJ-06 announced EPSG:25830 409922.0 4750315.0 None m; not installed MW published resolution (m): 0.01 positional accuracy (m): None
Armus / AR_04 announced EPSG:25830 385320.0 4658242.0 879.0 m; not installed MW published resolution (m): 1 positional accuracy (m): None
Ado / AD-08 announced EPSG:25829 513452.0 4748415.0 None m; not installed MW published resolution (m): 1 positional accuracy (m): None
Repowering generations preserve predecessor links and exclude unresolved scopes
Lindesnes — 2019 repowering 9d2c471c-41f5-57f2-98cc-80a90b778989 unresolved 2019-07-03 None
Nye Hitra 1 5a749774-e036-52ad-8984-5e21a53a72ca unresolved None None
Cable configurations: 24 ; installed length and total mass unknown
Operator annual output lacks period and gross/net boundary; no capacity factors calculated.
Total running time of the script: (0 minutes 16.800 seconds)






